• Title/Summary/Keyword: Cone-beam CT

Search Result 229, Processing Time 0.024 seconds

Cone Beam Computed Tomography in Endodontics (근관치료 영역에서 Cone Beam CT의 활용)

  • Jo, Hyoung-Hoon
    • The Journal of the Korean dental association
    • /
    • v.57 no.7
    • /
    • pp.392-402
    • /
    • 2019
  • The most important part of everyday root canal treatment is diagnosis about the morphology of tooth, root and root canal. Usually this procedure is performed by visual examination and radiographic (panoramic/periapical) examination. However, 2-dimentional radiography has several limitations such as imposition of anatomic structures including buccal/lingual root canals and distortion of images. Recently, owing to the increased interest in dental implant and affordable cost of CBCT equipment, CBCT has been introduced widely in local dental clinics. CBCT is characterized by their lower radiation dose and shorter exposure time than conventional CT scan, and ability of 3-dimentional reconstruction of the dento-alveolar structure. Also in endodontic field, the data from CBCT could be very helpful in diagnosing complex root canal anatomy, apical periodontitis, cause of failure and in determining treatment plan. However, there are some limitations such as radiation dose and artifact. Therefore, clinicians should know about indication, advantages and limitations of CBCT, and properly use it for successful root canal treatment to save the natural teeth.

  • PDF

Noise Reduction of medical X-ray Image using Wavelet Threshold in Cone-beam CT (Cone-beam CT에서 웨이브렛 역치값을 이용한 x-ray 영상에서의 노이즈 제거)

  • Park, Jong-Duk;Huh, Young;Jin, Seung-Oh;Jeon, Sung-Chae
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.6
    • /
    • pp.42-48
    • /
    • 2007
  • In x-ray imaging system, two kinds of noises are involved. First, the charge generated from the radiation interaction with the detector during exposure. Second, the signal is then added by readout electronics noise. But, x-ray images are not modeled by Gaussian noise but as the realization of a Poisson process. In this paper, we apply a new approach to remove Poisson noise from medical X-ray image in the wavelet domain, the applied methods shows more excellent results in cone-beam CT.

SURGICAL STENT FABRICATION AND CLINICAL APPLICATION FOR ORTHOGNATHIC SURGERY USING Cone-Beam CT (Cone-Beam CT를 이용한 악교정 수술용 스텐트 제작과 임상 적용)

  • Kim, Yong-Il;Kim, Jong-Ryoul;Kim, Seong-Sik;Son, Woo-Sung;Park, Soo-Byung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.2
    • /
    • pp.158-166
    • /
    • 2009
  • The application of CT with basis on 3 dimensional-reconstruction is getting more widely practiced. With the data obtained from cone-beam computed tomography(CBCT), not only the diagnosis of the patient with skeletal abnormality but also the virtual simulation of the orthognathic surgery were performed and its application would be popular in orthodontic field. We reported a case, a 19-year old man who was diagnosed mandibular prognathism and required orthognatic surgery. In this case, the virtual orthognathic surgery was simulated and surgical wafer was fabricated by using CBCT data. That wafer was applied the actual orthognathic surgery. After preoperative orthodontic treatment, we prepared surgery as follows. : (l)Acquisition of 3D image data, (2)Reconstruction of 3-dimensional virtual model, (3)Virtual model surgery, (4)Extraction of stere-olithographic image, (5)Check-up for occlusal interference, (6)Fabrication of surgical stent by stereolithography. Bilateral sagittal split ramus osteotomy was operated and used stereolithographic surgical stent. 1 month later, we superimposed CBCT datas of virtual surgery and that of actual surgery, and then compared the result. CT data's application for othognathic surgery yielded satisfactory outcomes.

Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

  • Oliveira, Matheus L.;Tosoni, Guilherme M.;Lindsey, David H.;Mendoza, Kristopher;Tetradis, Sotirios;Mallya, Sanjay M.
    • Imaging Science in Dentistry
    • /
    • v.44 no.4
    • /
    • pp.279-285
    • /
    • 2014
  • Purpose: To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Materials and Methods: Tubes containing solutions with different concentrations of $K_2HPO_4$ were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the $K_2HPO_4$ solutions were measured. The relationship between CT number and $K_2HPO_4$ concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. Results: The relationship between $K_2HPO_4$ concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. Conclusion: There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.

ERUPTION PATTERN OF THE MANDIBULAR FIRST MOLAR USING THE CONE BEAM CT (Cone Beam CT를 이용한 하악 제 1대구치 맹출 양상에 관한 연구)

  • Shin, Jeong-Keun;Kim, Jae-Gon;Baik, Byeong-Ju;Yang, Yeon-Mi;Jeong, Jin-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.3
    • /
    • pp.325-336
    • /
    • 2009
  • The purpose of this study was to investigate the eruption pattern of the mandibular first molar in sagittal, frontal and horizontal views using the cone beam CT scanning. CT images were obtained from healthy 83 children (42 boys, 41 girls) between 3 to 10 years of age with a normal dentition according to Nolla stage. 1. In the frontal and horizontal view, the intermolar width decreased continuously with stage and slightly increased at the last stage. 2. In the sagittal and frontal view, eruption distances from occlusal plane were observed the largest change between stage 5 and 7. 3. In the horizontal and sagittal view, mandibular first molar from distal surface of primary second molar moved distally between stage 4 and 6. 4. In the sagittal view, angle from occlusal plane to mesio-distal axis increased between stage 4 and 8. 5. In the frontal view, angle from occlusal plane to bucco-lingual axis increased continuously during all stage. 6. In the horizontal view, angle from midsagittal plane to long axis increased between stage 5 and 8.

  • PDF

Three-Dimensional Evaluation of Impacted Mesiodens Using Dental Cone-Beam Computed Tomography in Korean Children and Adolescents (치과용 cone beam CT를 이용한 한국인 소아 및 청소년의 매복 정중과잉치에 대한 3차원적 분석)

  • Kim, Sang-Duk;Lee, Sang-Ho;Lee, Nan-Young;Jeon, Sang-Yun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.3
    • /
    • pp.149-158
    • /
    • 2013
  • The purpose of this study was to evaluate the shape and impacted pattern of mesiodens and associated complications using three dimensional images produced by dental CBCT. This study was based on the CBCT (CB Mercury, Hitachi, Tokyo, Japan) radiographic view of 280 pediatric patients who visited the Department of Pediatric Dentistry at the Chosun University Dental Hospital with the chief complain of mesiodens during between 2007 and 2012. Impacted mesiodens occurs more frequently in boys than in girls, the ratio being approximately 3.3:1 and most cases were observed between 6 and 8 years of age. The number of mesiodens per patient was 1.38. Majority of the mesiodens were conical (79.5%) in shape and inverted (48.6%) in direction. The mesio-distal position of mesiodens were the most common in middle sector (81.8%), vertical level were the most common near cervical (60.3%), and labio-palatal position were the most common at palatal side of the dental arch (73.8%). 47.5% of mesiodens had complications and common complications associated with mesiodens were displaced tooth and delayed eruptions. The shape, vertical level, and labio-palatal position of mesiodens had correlations with complications. CBCT appears to be an excellent diagnostic tool, providing three dimensional information and accurate images, for diagnosis of impacted mesiodens.

Utility of the computed tomography indices on cone beam computed tomography images in the diagnosis of osteoporosis in women

  • Koh, Kwang-Joon;Kim, Kyoung-A
    • Imaging Science in Dentistry
    • /
    • v.41 no.3
    • /
    • pp.101-106
    • /
    • 2011
  • Purpose : This study evaluated the potential use of the computed tomography indices (CTI) on cone beam CT (CBCT) images for an assessment of the bone mineral density (BMD) in postmenopausal osteoporotic women. Materials and Methods : Twenty-one postmenopausal osteoporotic women and 21 postmenopausal healthy women were enrolled as the subjects. The BMD of the lumbar vertebrae and femur were calculated by dual energy X-ray absorptiometry (DXA) using a DXA scanner. The CBCT images were obtained from the unilateral mental foramen region using a PSR-$9000N^{TM}$ Dental CT system. The axial, sagittal, and coronal images were reconstructed from the block images using $OnDemend3D^{TM}$. The new term "CTI" on CBCT images was proposed. The relationship between the CT measurements and BMDs were assessed and the intra-observer agreement was determined. Results : There were significant differences between the normal and osteoporotic groups in the computed tomography mandibular index superior (CTI(S)), computed tomography mandibular index inferior (CTI(I)), and computed tomography cortical index (CTCI). On the other hand, there was no difference between the groups in the computed tomography mental index (CTMI: inferior cortical width). Conclusion : CTI(S), CTI(I), and CTCI on the CBCT images can be used to assess the osteoporotic women.

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF

Image characteristics of cone beam computed tomography using a CT performance phantom (CT performance phantom을 이용한 cone beam형 전산화단층영상의 특성)

  • Han, Choong-Wan;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.157-163
    • /
    • 2007
  • Purpose: To evaluate the characteristics of (widely used) cone beam computed tomography (CBCT) images. Materials and Methods: Images were obtained with CT performance phantoms (The American Association of Physicists in Medicine; AAPM). CT phantom as the destination by using PSR $9000N^{TM}$ dental CT system (Asahi Roentgen Ind. Co., Ltd., Japan) and i-CAT CBCT (Imaging Science International Inc., USA) that have different kinds of detectors and field of view, and compared these images with the CT number for linear attenuation, contrast resolution, and spatial resolution. Results: CT number of both PSR $9000N^{TM}$ dental CT system and i-CAT CBCT did not conform to the base value of CT performance phantom. The contrast of i-CAT CBCT is higher than that of PSR $9000N^{TM}$ dental CT system. Both contrasts were increased according to thickness of cross section. Spatial resolution and shapes of reappearance was possible up to 0.6 mm in PSR $9000N^{TM}$ dental CT system and up to 1.0 mm in i-CAT CBCT. Low contrast resolution in region of low contrast sensitivity revealed low level at PSR $9000N^{TM}$ dental CT system and i-CAT CBCT. Conclusion: CBCT images revealed higher spatial resolution, however, contrast resolution in region of low contrast sensitivity was the inferiority of image characteristics.

  • PDF