Usefulness of Mobile Computed Tomography in Patients with Coronavirus Disease 2019 Pneumonia: A Case Series

  • Ji Young Rho;Kwon-Ha Yoon;Sooyeon Jeong;Jae-Hoon Lee;Chul Park;Hye-Won Kim
    • Korean Journal of Radiology
    • /
    • 제21권8호
    • /
    • pp.1018-1023
    • /
    • 2020
  • The coronavirus disease (COVID-19) outbreak has reached global pandemic status as announced by the World Health Organization, which currently recommends reverse transcription polymerase chain reaction (RT-PCR) as the standard diagnostic tool. However, although the RT-PCR test results may be found negative, there are cases that are found positive for COVID-19 pneumonia on computed tomography (CT) scan. CT is also useful in assessing the severity of COVID-19 pneumonia. When clinicians desire a CT scan of a patient with COVID-19 to monitor treatment response, a safe method for patient transport is necessary. To address the engagement of medical resources necessary to transport a patient with COVID-19, our institution has implemented the use of mobile CT. Therefore, we report two cases of COVID-19 pneumonia evaluated by using mobile cone-beam CT. Although mobile cone-beam CT had some limitations regarding its image quality such as scatter noise, motion and streak artifacts, and limited field of view compared with conventional multi-detector CT, both cases had acceptable image quality to establish the diagnosis of COVID-19 pneumonia. We report the usefulness of mobile cone-beam CT in patients with COVID-19 pneumonia.

Characteristic features of fungus ball in the maxillary sinus and the location of intralesional calcifications on computed tomographic images: A report of 2 cases

  • Lee, Jae-Hoon;Lee, Byung-Do
    • Imaging Science in Dentistry
    • /
    • 제50권4호
    • /
    • pp.377-384
    • /
    • 2020
  • This report presents 2 cases of sinus fungus ball and describes the characteristic radiographic features of fungus ball in the maxillary sinus. Two female patients, aged 62 and 40 years, sought consultations at a dental hospital for the treatment of dental implants and tooth pain, respectively. Panoramic radiography and small field-of-view(FOV) cone-beam computed tomography (CBCT) did not provide detailed information for the radiographic diagnosis of fungus ball due to the limited images of the maxillary sinus. Additional paranasal sinus computed tomographic images showed the characteristic features of fungus ball, such as heterogeneous opacification and intralesional calcification of the maxillary sinus. The calcified materials of the fungus balls were located in the middle and superior regions of the maxillary sinus. It is necessary to use large-FOV CBCT for the detection of calcified materials in the upper maxillary sinus to confirm the diagnosis of fungus ball.

kV Cone-beam CT를 사용한 치료준비에서 재구성 영상의 품질이 표적 위치 결정에 미치는 영향 (How Image Quality Affects Determination of Target Displacement When Using kV Cone-beam Computed Tomography (CBCT))

  • 오승종;김시용;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.207-211
    • /
    • 2006
  • kV cone-beam CT (CBCT)가 결합된 선형가속기의 등장으로 더욱 정확한 영상유도 방사선치료(Image-guided radiation therapy, IGRT)가 가능해졌다. IGRT는 영상장비를 이용해 표적의 이동을 보정할 수 있는 방사선치료기술로, CBCT를 이용한 IGRT의 경우 내부 장기의 정보를 바탕으로 병변의 이동을 정확히 알 수 있다. 내부 장기의 정보를 얻기 위해서는 방사선이 조사되기 바로 전에 환자의 CBCT 영상을 획득하여 치료계획 시 사용한 모의치료 CT영상과 정합을 수행하게 된다. 본 연구에서는 CBCT 영상의 재구성 품질에 따른 정합결과를 비교해 보았다. 6명의 환자로부터 총 56개의 CBCT 투과 정보를 획득하여 분석한 결과, 평행이동벡터의 차가 1 mm를 초과하는 경우는 단 3개에 불과하였다. 회전이동의 경우, x, y, z, 세 축을 모두 고려하였으며, 그 결과 총 168 ($56{\times}3$)개에서 단 3개만이 $1^{\circ}$ 이상의 차이를 나타냈다.

  • PDF

몬테칼로 기법을 이용한 CBCT의 광자선 특성 및 선량 분석 (Analysis of Photon Characteristics and Absorbed Dose with Cone Beam Computed Tomography (CBCT) using Monte Carlo Method)

  • 김종보;김정훈;박은태
    • 한국방사선학회논문지
    • /
    • 제11권3호
    • /
    • pp.161-169
    • /
    • 2017
  • 방사선 치료 시 자세 확인 촬영을 목적으로 3차원 영상 획득이 가능한 콘빔씨티 촬영이 많이 이용되고 있다. 본 연구에서는 몬테칼로 기법을 이용한 모의실험을 통해 콘빔씨티 촬영 시 피폭선량을 정략적으로 분석하고 표준화된 데이터를 제시하고자 한다. 실험은 MCNPX(ver. 2.5.0)를 이용하였으며, 먼저 콘빔씨티를 모사한 후 광자선 스펙트럼을 분석하였다. 그리고 물 팬텀을 모사하여 깊이별 심부선량 백분율과 흡수선량을 측정하였다. 광자선 스펙트럼을 분석한 결과, 관전압 80 ~ 120 kVp 에서 평균 에너지는 조건에 따라 25.7 ~ 52.6 keV로 나타났으며 특성X선 에너지는 9, 60, 68, 70 keV로 나타났다. 물 팬텀을 사용하여 심부선량 백분율을 측정한 결과 표면에서 최대선량이 나타났으며 깊이가 깊어질수록 감소하는 것으로 나타났다. 흡수선량 또한 깊이가 증가할수록 감소하였으며 팬텀 전체가 받는 흡수선량은 9.7 ~ 18.7 mGy로 나타났다. 이는 일반적으로 방사선 치료에 사용되는 주당 처방선량인 약 10Gy의 0.2%를 차지하는 선량이며 이는 치료효과에는 큰 영향을 미치지 않을 것으로 판단된다. 그러나 처방선량에 비해 미미한 수준일지라도 이를 간과해서는 안 될 것이다.

Cone-beam computed tomography를 이용한 미맹출 영구치의 계측 (ACCURACY OF CONE-BEAM COMPUTED TOMOGRAPHY IN PREDICTING THE DIAMETER OF UNERUPTED TEETH)

  • 김성희;김영종;김신;정태성
    • 대한소아치과학회지
    • /
    • 제39권2호
    • /
    • pp.139-144
    • /
    • 2012
  • 본 연구는 CBCT(Cone-beam computed tomography)영상에서 미맹출 치아 크기 측정의 재현성과 정확성을 평가하기 위해 시행되었다. 매복치를 주소로 부산대학교 치과병원 소아치과에 내원한 혼합치열기 환자 중 진단 목적으로 CBCT 채득에 동의한 환자의 미맹출 견치 및 소구치 69개를 대상으로 하였다. CBCT 영상에서 측정한 미맹출 치아의 최대 근원심 폭경 계측치와 동일한 치아가 구강 내로 완전히 맹출한 후 채득한 석고 모형에서 대상 치아를 digital caliper로 측정한 최대 근원심 폭경 계측치를 비교하여 다음과 같은 결론을 얻었다. 1. CBCT 영상에서 미맹출 치아를 계측하는 방법은 재현성이 높다(ICC=0.91). 2. CBCT 영상에서 측정한 미맹출 치아의 최대 근원심 폭경 계측치와 석고 모형에서 측정한 대상 치아의 최대 근원심 폭경 계측치는 높은 상관 관계가 있었다(r=0.91). 3. CBCT 영상에서 측정한 미맹출 치아 최대 근원심 폭경 계측치와 석고 모형에서 측정한 대상 치아의 최대 근원심 폭경 계측치는 통계적으로 유의한 차이가 있었다($p$ <0.05). CBCT 영상에서 측정한 미맹출 치아 최대 근원심 폭경의 계측치가 석고 모형에서 측정한 대상 치아의 최대 근원심 폭경 계측치보다 평균 0.2 mm 작게 측정되었다. 그러나 이러한 차이는 임상적으로 수용 가능한 수준이라 생각된다.

Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans

  • Shokri, Abbas;Ramezani, Leila;Bidgoli, Mohsen;Akbarzadeh, Mahdi;Ghazikhanlu-Sani, Karim;Fallahi-Sichani, Hamed
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.31-39
    • /
    • 2018
  • Purpose: This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from cone-beam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. Materials and Methods: A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values(MGVs) of each cylinder were calculated in each imaging protocol. Results: In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes(P<.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. Conclusion: The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography

  • Shokri, Abbas;Eskandarloo, Amir;Noruzi-Gangachin, Maruf;Khajeh, Samira
    • Restorative Dentistry and Endodontics
    • /
    • 제40권1호
    • /
    • pp.58-67
    • /
    • 2015
  • Objectives: This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. Materials and Methods: Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. Results: The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. Conclusions: If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.

Detection of different foreign bodies in the maxillofacial region with spiral computed tomography and cone-beam computed tomography: An in vitro study

  • Abolvardi, Masoud;Akhlaghian, Marzieh;Shishvan, Hadi Hamidi;Dastan, Farivar
    • Imaging Science in Dentistry
    • /
    • 제50권4호
    • /
    • pp.291-298
    • /
    • 2020
  • Purpose: The detection and exact localization of penetrating foreign bodies are crucial for the appropriate management of patients with dentoalveolar trauma. This study compared the efficacy of cone-beam computed tomography (CBCT) and spiral computed tomography (CT) scans for the detection of different foreign bodies composed of 5 frequently encountered materials in 2 sizes. The effect of the location of the foreign bodies on their visibility was also analyzed. Materials and Methods: In this in vitro study, metal, tooth, stone, glass, and plastic particles measuring 1×1×1 mm and 2×2×2 mm were prepared. They were implanted in a sheep's head in the tongue muscle, nasal cavity, and at the interface of the mandibular cortex and soft tissue. CBCT and spiral CT scans were taken and the visibility of foreign bodies was scored by 4 skilled maxillofacial radiologists who were blinded to the location and number of foreign bodies. Results: CT and CBCT were equally accurate in visualizing metal, stone, and tooth particles of both sizes. However, CBCT was better for detecting glass particles in the periosteum. Although both imaging modalities visualized plastic particles poorly, CT was slightly better for detecting plastic particles, especially the smaller ones. Conclusion: Considering the lower patient radiation dose and cost, CBCT can be used with almost equal accuracy as CT for detecting foreign bodies of different compositions and sizes in multiple maxillofacial regions. However, CT performed better for detecting plastic particles.

Correlation between gray values of cone-beam computed tomograms and Hounsfield units of computed tomograms: A systematic review and meta-analysis

  • Selvaraj, Abirami;Jain, Ravindra Kumar;Nagi, Ravleen;Balasubramaniam, Arthi
    • Imaging Science in Dentistry
    • /
    • 제52권2호
    • /
    • pp.133-140
    • /
    • 2022
  • Purpose: The aim of this review was to systematically analyze the available literature on the correlation between the gray values (GVs) of cone-beam computed tomography (CBCT) and the Hounsfield units (HUs) of computed tomography (CT) for assessing bone mineral density. Materials and Methods: A literature search was carried out in PubMed, Cochrane Library, Google Scholar, Scopus, and LILACS for studies published through September 2021. In vitro, in vivo, and animal studies that analyzed the correlations GVs of CBCT and HUs of CT were included in this review. The review was prepared according to the PRISMA checklist for systematic reviews, and the risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool. A quantitative analysis was performed using a fixed-effects model. Results: The literature search identified a total of 5,955 studies, of which 14 studies were included for the qualitative analysis and 2 studies for the quantitative analysis. A positive correlation was observed between the GVs of CBCT and HUs of CT. Out of the 14 studies, 100% had low risks of bias for the domains of patient selection, index test, and reference standards, while 95% of studies had a low risk of bias for the domain of flow and timing. The fixed-effects meta-analysis performed for Pearson correlation coefficients between CBCT and CT showed a moderate positive correlation (r=0.669; 95% CI, 0.388 to 0.836; P<0.05). Conclusion: The available evidence showed a positive correlation between the GVs of CBCT and HUs of CT.

Validation and comparison of volume measurements using 1 multidetector computed tomography and 5 cone-beam computed tomography protocols: An in vitro study

  • Juliana Andrea Correa, Travessas;Alessandra Mendonca, dos Santos;Rodrigo Pagliarini, Buligon;Nadia Assein, Arus;Priscila Fernanda Tiecher, da Silveira;Heraldo Luis Dias, da Silveira;Mariana Boessio, Vizzotto
    • Imaging Science in Dentistry
    • /
    • 제52권4호
    • /
    • pp.399-408
    • /
    • 2022
  • Purpose: The purpose of this study was to compare volume measurements obtained using 2 image software packages on Digital Imaging and Communications in Medicine (DICOM) images acquired from 1 multidetector computed tomography and 5 cone-beam computed tomography devices, using different protocols for physical volume measurements. Materials and Methods: Four pieces of bovine leg were prepared. Marrow was removed from 3 pieces, leaving cortical bone exposed. The resulting space of 1 piece was filled with water, another was filled with propylene glycol, and the third was left unfilled. The marrow in the fourth sample was left fully intact. Volume measurements were obtained after importing DICOM images into the Dolphin Imaging 11.95 and ITK-SNAP software programs. Data were analyzed using 3-way analysis of variance with a generalized linear model to determine the effects of voxel size, software, and content on percentage mean volume differences between tomographic protocols. A significance level of 0.05 was used. Results: The intraclass correlation coefficients for intraobserver and interobserver reliability were, respectively, 0.915 and 0.764 for the Dolphin software and 0.894 and 0.766 for the ITK-SNAP software. Three sources of statistically significant variation were identified: the interaction between software and content (P=0.001), the main effect of content (P=0.014), and the main effect of software (P=0.001). Voxel size was not associated with statistically significant differences in volume measurements. Conclusion: Both content and software influenced the accuracy of volume measurements, especially when the content had gray values similar to those of the adjacent tissues.