• Title/Summary/Keyword: Cone cassette

Search Result 3, Processing Time 0.021 seconds

Contemplation on Usefulness of Plane Cone for Taking Image of Intercondyloid Fossa (무릎 과간와(Intercondyloid fossa) 촬영용 평면 Cone의 유용성에 대한 고찰)

  • Shin, WoonJae
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.501-508
    • /
    • 2015
  • There are various Intercondyloid fossa X-ray taking methods. The methods carried out in clinics are Holmblad method, Camp-Conventry method, and Beclere method. Taking image of Intercondyloid fossa is carried a lot as basic examination for diagnosis related to simple fracture and cruciate ligament. Considering the condition and pains of patients, safe method is chosen but because Holmblad method can cause pains to knee part adhering to cassette, it is not easily used. In this study self-produced plane circular cone was attached to a cassette and in the posture for Holmblad method questionnaires of 100 applicants were analyzed to understand cognition on alleviation of pains, and the concentration of imge quality by scattering rays was measured with densitometer by taking human body phantom with X-ray. As a result, in the posture for Holmblad method, cognition on pains was alleviated by average 99%, and the change of concentration of X-ray film taken using phantom by scattering rays decreased statistically significantly compared to the cassette which did not use self-produced plane cone, therefor it is thought that the method can be valuably used in clinics.

Fabrication and Dosimetry Characteristics of Intracavitary Cones for Radiotherapy (방사선 강내치료를 위한 소조사면 전자선cone의 선량분포 특성)

  • 나수경;권수일
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.95-102
    • /
    • 2001
  • The intracavitary cones were designed which were made of stainless steel and have scratched inside cone to be generated electron scatter and designed to be attached easily to the LINAC collimator and controlled cones length to be contacted smoothly between the patient and the cone tip. Two types of intracavitary cones were designed. One is the straight end cones with circular opening on the distal end and the other is 30 degree beveled end cones with elliptical opening on the distal end. Each type of intracavitary cone ranged in daimeter from 2.5 cm to 3.5 cm and required a separate set of lower trimmer annulias cone diameter. The film phantom was designed with an internal cassette that accurately aligned the film edge with the film phantom surface. Film optical density data were measured by photodensitometer(Wellhofer 700i) Dosimetry measurements were made to commission the LINAC for 6 - 20 MeV electron using the intracavitary cones. Isodose curves were measured for all energy and cones combinations. Output is defined as the maximum dose per MU along the clinical central axis in water at 113 cm SSD. Calibration output, defined to be the output for the 15cm$\times$15cm diameter straight cone, was adjusted to 1.00 cGy/MU at each energy according to the TG-21 protocol.

  • PDF

Work Related Musculoskeletal Symptoms and their Related Factors in Radiological Tehnologist. (치료방사선사의 직무에 의한 신체손상(근골격계 증상)에 관한 연구)

  • Lee, Byung-Chul;Cho, Jung-Hee;Shin, Dong-Bong;Woo, Jung-Yeol;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.16 no.1
    • /
    • pp.39-50
    • /
    • 2004
  • This study was carried out to evaluate the effect of general and occupational characteristics musculoskeletal symptoms in Radiological Technologist who working in present department more than 1 year. Standardized questionnaire of NIOSH and organized questionnaire for 재rk-related musculoskeletal was to 72Radiological Technologist, employed in 6general hospital in Seoul in September, 2003. The symptom prevalence rate of musculoskeletal symptoms were neck ($33.3\%$), shoulder ($33.3\%$), arm($12.5\%$), hand($13.9\%$), spine($34.7\%$)leg/knee/foot ($31.9\%$), arm/wrist/hand ($16.5\%$).

  • PDF