• 제목/요약/키워드: Cone Test

검색결과 803건 처리시간 0.035초

현장시험법을 통한 인천지역 해성퇴적토의 전단파 속도 특성 고찰 (Investigation on S-wave Velocity for The Marine Deposits in Incheon Coastal Area.)

  • 최원일;정남훈;김학문
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1340-1352
    • /
    • 2008
  • In this study, S-wave velocity range is gauged in every field test method at the total 5 locations in the marine deposits in Incheon area. field test method is accomplished the SPT(Standard Penetration Test), CPT(Cone Penetration Test), SPS(Suspension PS Logger), SCPT (Seismic Cone Penetration Test) and so on. The S-wave velocity of SCPT in the downhole test method is measured lower than SPS logger at the N value > 15 range. But at the N value < 15 range, SPS logger and SCPT result is measured same. In this result, although the soil strength of the downhole test method increased, the rate of S-wave velocity is tend to be slowed. This result shows that the downhole test is difficult to apply at the place that the intensity of soil is more extreme and harder soil. And it shows that the existing Imai(1982) type that is mostly used within the country is not suitable for the marine deposits. Thus, the empirical formula that can show the range of S-wave velocity in each N value for domestic soil is needed.

  • PDF

원위치 관입실험기를 활용한 철도 노반 평가 (Railbed Evaluation by using In-situ Penetration Test)

  • 김주한;박정희;윤형구;고태훈;이종섭
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.261-267
    • /
    • 2011
  • The test fit has commonly used for the evaluation of the railbed condition, and indirect methods by using the compressional wave are also studied. the direct evaluation method by penetration test has not been studied. For the measurement of in-situ cone tip resistance of the railbed with minimizing the disturbance of the upper railbed. the cone penetrometer with the helical type outer rod(CPH) was developed. The outer rod, which has helical screw, is penetrated through the gravel layer and provides the reaction force for cone penetration testing. the cone tip resistances are measured by the mini cone penetrometer, where diameter is 15mm. For the developing the mini cone, strain gauge installation, circuit configuration, penetration rates and calibration process are considered. For the easy penetration of the screw rod in the field, the reaction force stepping plate and guide column are arranged. The screw rod are penetrated through the gravel layer. And the mini cone was pushed into the subgrade railbed at the penetration rate of 1mm/sec. The penetration test shows that the cone tip resistance increases along the depth. In addition, the subgrade condition is evaluated. This study demonstrates that the CPH may be effectively used for the evaluation of subgrade method any damage of the gravel layer.

  • PDF

비탈면 취약도 평가를 위한 동적콘관입시험기 모듈개발과 표준관입시험값과의 상관관계 연구 (Development of Dynamic Cone Penetration Tester Module for Slope Vulnerability Assessment and Correlation of Its Results with Standard Penetration Test Values)

  • 채휘영;권순달
    • 지질공학
    • /
    • 제31권4호
    • /
    • pp.541-547
    • /
    • 2021
  • 비탈면의 유실, 붕락사고 등 비탈면에 대한 안정성을 파악하기 위해서 지층의 구성상태, 역학적 특성 등의 지반정보 파악이 필요하다. 이러한 지반정보를 파악하기 위해서 일반적으로 표준관입시험(SPT) 및 콘 관입시험 등이 널리 이용되고 있다. 대부분이 급경사로 이루어지고 진입로가 없는 비탈면에 대한 접근성 문제로 표준관입시험이 널리 활용되지 못하고 있다. 이러한 단점을 보완할 수 있는 있는 휴대용 장비인 Drop Cone Penetrometer(DCP)를 이용한 조사도 여러 가지 문제로 제한적으로 사용되고 있다. 따라서 본 연구에서는 비탈면 현장접근이 용이한 휴대용 시추기와 동적콘관입시험 모듈을 개발하고, 개발된 동적콘관입시험기를 이용한 결과와 동일 현장에서 수행한 표준관입시험값과 상관성을 분석하였다. 에너지전단율로 보정된 동적콘관입시험과 표준관입시험간의 상관식은 Nd' = 3.13 N'으로 나타났다.

농경지 오염탐사를 위한 비저항콘의 적용성에 관한 연구 (A Study on the Applicability of Resistivity Cone for Contaminant Investigation in Farm Land)

  • 유찬;윤춘경
    • 농촌계획
    • /
    • 제5권1호
    • /
    • pp.45-55
    • /
    • 1999
  • The applicability of resistivity cone for contaminant investigation in farm land was examined in laboratory and in-situ. To verify the resistivity variations in sand with contaminants, laboratory experiment used soil resistivity test box was performed. Heavy metal and others ions were appeared steep variations in low concentration. Pilot test results were the same as laboratory test results. In the in-situ test used resistivity cone, resistivities of waste landfill layer were low than the common soil layers and resistivities had been difference with concentration of contaminant components. Therefore contaminant investigation in farm land using resistivity cone was expected very effective.

  • PDF

Cone-Calorimeter와 연기밀도챔버를 이용한 고무발포단열재의 연기밀도 비교 (Smoke Density Comparison of Rubber Foam Insulator by the test between Cone-Calorimeter and Smoke Density-Chamber)

  • 조희기;이덕희;이철규;이동우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.941-946
    • /
    • 2005
  • Kinds of Sound & Thermal Insulator are being used for materials of railroad vehicles as a barrier of beat and noise. Glass Wool, PE foam, PP foam are such kinds of materials. In case of fire, it shows various combustion properties. In this study, we compared the Smoke Density of the Rubber Foam Insulator by test between Cone-Calorimeter and Smoke Density-Chamber. The results showed that the Rubber Foam Insulator had an important role in the insulator thickness and the test method, We forecast the smoke density by test between Cone-Calorimeter and Smoke Density-Chamber.

  • PDF

폐비닐 골재 혼합 아스콘의 성질 (Characteristics of Asphalt Concrete Mixed with Polyethylene Aggregate)

  • 김영진
    • 한국지반환경공학회 논문집
    • /
    • 제18권12호
    • /
    • pp.5-11
    • /
    • 2017
  • 농촌 비닐하우스에서 배출되는 폐비닐을 녹여 19mm 크기의 골재를 만들었다. 이것을 아스콘에 몇몇 중량비로 혼합한 후 단열효과시험, 동결융해 후 인장강도시험, 빙착인장강도시험 그리고 현장 밀도시험을 각각 실시하였다. 그 결과 폐비닐골재는 내부에 공극을 다수 포함하고 있는 관계로 폐비닐골재 혼합율이 증가할수록 단열효과가 증가하였다. 아스콘의 동결융해 후 인장강도는 폐비닐골재 혼합율 0%일 때보다 혼합율 2.5%일 경우 크게 증가하였지만, 혼합율 5%, 10%에서는 혼합율 2.5%일 때보다 다소 감소하는 경향을 보였다. 빙착인장강도는 일반아스콘에 비해 폐비닐골재를 2.5% 추가한 아스콘에서 더 작게 나타났다. 현장 채취시료에 대한 공극률시험 결과 폐비닐골재를 추가한 아스콘의 공극률이 일반 아스콘의 그것보다 작았다.

Cone Pressuremeter를 이용한 점성토의 전단 강도 산정 (Determination of Undrained Shear Strength In Clay from Cone Pressuremeter Test)

  • 이장덕
    • 한국지반공학회논문집
    • /
    • 제20권8호
    • /
    • pp.49-58
    • /
    • 2004
  • 콘프레셔미터는 피에조콘 시험과 프레셔미터 시험을 동시에 수행할 수 있는 현장시험기로서 본 연구에서는 국내 점토지반에서 수행한 시험결과를 해석적으로 분석하였다. 콘프레셔미터 결과에 대한 이론적인 해는 흙이 비선형 거동을 하는 경우와 전단변형 중 체적변화가 발생하지 않는 경우에 대하여 해석적인 해가 존재한다. 이러한 해석적인 해로부터 콘프레셔미터의 결과중 하중 재하구간과 제하구간에 대해 Curve Fitting 방법을 사용한 콘프레셔미터 결과의 해석 방법을 제안하였다. 20개소의 현장에서 수행한 콘프레셔미터 결과 중 지반교란의 영향을 적게 받는 제하구간에 대하여 Curve Fitting 방법을 적용하여 점성토의 비배수 전단특성을 구하였다. 이렇게 구한 지반의 비배수 전단강도와 현장 Vane, 일축압축, 삼축압축 시험결과로부터 구한 지반의 비배수 전단강도를 서로 비교하여 콘프레셔미터 시험 결과로부터 Curve Fitting 방법을 통한 점성토 지반의 전단강도 특성파악의 적정성에 대해 평가하였다.

개량식 동적 콘 관입시험기의 개발 및 적용성 평가 (Development of Advanced Dynamic Cone Penetration Test Apparatus and Its Application Performance Evaluation)

  • 김욱기;;이광우
    • 한국지반신소재학회논문집
    • /
    • 제13권4호
    • /
    • pp.119-131
    • /
    • 2014
  • 본 연구에서는 광역 부지나 현장 접근성이 용이하지 않은 현장의 지반조사를 신속 정확하게 수행하기 위한 목적으로 해외에서 널리 사용되고 있는 동적 콘 관입시험기를 개선한 개량형 동적 콘 관입시험기를 개발하였다. 기존의 동적 콘 관입시험기의 장점인 휴대성, 간단한 시험방법 등은 그대로 반영하는 한편, 하부 로트의 결합 연장을 통하여 기존 시험기의 지반 관입심도 1m에서 6m까지 관입되도록 고안하였다. 또한, 해머(2+3+3kg), 콘(3type) 등의 조합으로 독일식/일본식 간이 동적 콘 관입시험기(Tsukuba, PWRI, SH type)와 동일한 제원으로 시험이 가능하며, 심도가 깊어짐에 따라 시험 결과에 영향을 미치는 수직도를 확보할 수 있도록 보조 장치를 적용시켰다. 이렇게 개발 제작한 개량형 동적 콘 관입시험기의 적용성을 평가하기 위하여 국내/외 현장의 다양한 지반에 대하여 시험을 수행하여 그 신뢰성을 확보하였다.

제체 상태 평가를 위한 동적 콘 관입시험과 평판재하시험 결과의 상관관계 분석 (The Correlation Analysis between Dynamic Cone Penetration Test and Plate Loading Test Results for Evaluation of Dam Conditions)

  • 정영훈;김성민;임정열
    • 한국지반환경공학회 논문집
    • /
    • 제19권4호
    • /
    • pp.33-38
    • /
    • 2018
  • 제체 재료의 다짐 불량에 의한 내부 침식은 국내 제방의 주요 붕괴 원인으로, 제방의 안전진단에 있어서 제체의 다짐 상태 평가는 매우 중요한 점검 사항이다. 본 연구에서는 제체의 다짐상태 평가 시 동적 콘 관입시험의 현장 적용성을 검증하기 위해 대표적인 다짐평가 기법인 평판재하시험에 대해 상관관계를 분석하였다. 시험 부지의 지반 특성 및 토층 심도를 파악하기 위해 표준관입시험을 6회 수행하였다. 평판재하시험 15회, 동적 콘 관입시험 47회 수행 후 크리깅(Kriging) 기법으로 공간분포를 얻었다. 평판재하시험의 공간분포와 일정 관입깊이에서의 동적 콘 관입시험 공간분포 간의 피어슨 상관 계수를 계산하였다. 평판재하시험의 지지력과 관입 깊이 5cm, 10cm, 15cm에서의 동적 콘 관입시험의 타격횟수는 약한 양의 상관관계를 갖는 것으로 나타났다.

텍사스 콘 관입시험을 이용한 IGM에 근입된 현장타설말뚝의 설계 (Design of IGM Socketed Drilled Shafts Using Texas Cone Penetrometer Tests)

  • 남문석
    • 한국지반공학회논문집
    • /
    • 제22권10호
    • /
    • pp.55-67
    • /
    • 2006
  • IGM(Intermediate Geomaterial)에 근입된 현장타설말뚝의 설계를 수행하기 위해서는 대상 지반의 강도특성을 알아야 하고, 이를 위해 IGM에 대한 일축이나 삼축 등의 압축강도시험을 수행한다. 그러나, 설계 대상의 IGM지반이 풍화가 된 경우에는 압축강도시험을 통한 강도특성 파악이 힘들다. 이러한 경우에는 압축강도시험을 대체하여 IGM지반의 강도 특성을 파악할 수 있는 방법들이 필요로 한다. 본 연구에서는 현재 텍사스주 도로국(Texas Department of Transportation)에서 말뚝기초의 설계인자로서 사용 중인 텍사스 콘 관입시험(Texas Cone Penetrometer Test)을 이용하여 IGM지반의 역학특성을 파악하였다. 그리고 미국의 텍사스주 지역에 분포하는 IGM지반인 셰일(Clay Shale)과 석회암(Limestone)을 대상으로 시험현장을 선택하였고 말뚝재하시험과 텍사스 콘 관입시험을 수행하였다. 본 연구결과를 바탕으로 텍사스 콘 관입시험과 IGM 근입 현장타설말뚝의 주면마찰력과 선단지지력과의 상관관계를 제시하였다.