Ji Young Rho;Kwon-Ha Yoon;Sooyeon Jeong;Jae-Hoon Lee;Chul Park;Hye-Won Kim
Korean Journal of Radiology
/
v.21
no.8
/
pp.1018-1023
/
2020
The coronavirus disease (COVID-19) outbreak has reached global pandemic status as announced by the World Health Organization, which currently recommends reverse transcription polymerase chain reaction (RT-PCR) as the standard diagnostic tool. However, although the RT-PCR test results may be found negative, there are cases that are found positive for COVID-19 pneumonia on computed tomography (CT) scan. CT is also useful in assessing the severity of COVID-19 pneumonia. When clinicians desire a CT scan of a patient with COVID-19 to monitor treatment response, a safe method for patient transport is necessary. To address the engagement of medical resources necessary to transport a patient with COVID-19, our institution has implemented the use of mobile CT. Therefore, we report two cases of COVID-19 pneumonia evaluated by using mobile cone-beam CT. Although mobile cone-beam CT had some limitations regarding its image quality such as scatter noise, motion and streak artifacts, and limited field of view compared with conventional multi-detector CT, both cases had acceptable image quality to establish the diagnosis of COVID-19 pneumonia. We report the usefulness of mobile cone-beam CT in patients with COVID-19 pneumonia.
Journal of Dental Rehabilitation and Applied Science
/
v.26
no.2
/
pp.111-120
/
2010
Purpose: This investigation was designed to evaluate the condyle position and the symmetry of the both condyle heads at the maximum intercuspal position on the sagittal CT image of the temporomandibular joint. Materials and Methods: Cone-beam CT was used to assess 400 joints in 100 symptom and 100 symtom-free subject(100 male, 100 female). Three independent observers(dentists) determined the positions classified with Anterior Position(AP), Middle Position(MP), and Posterior Position(PP), and the symmetry of the both condyle. Results: According to gender, the mean percentages of AP, MP, and PP were 48.5, 28.5, and 23 in male group, and 34, 38, and 28 in female group. The symmetry of condylar heads was more common than asymmetry in the both of groups. In the respect of symptom or symptom-free, the mean percentages of AP, MP, and PP were 44.5, 34, and 21.5 in the symptom-free group, and 37, 33.5, and 29.5 in the symptom group. The symmetry of condylar heads was more common in the symptom-free group, but the asymmetry of condylar heads was more common in the symptom group. Conclusions: These data might serve as useful criteria for the clinical assessment of condyle position at the maximum intercuspal position optained by Cone-beam CT.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
v.35
no.1
/
pp.21-25
/
2009
Objective: The purpose of this study is to determine the prevalence of sinus disease and abnormalities in patients scheduled for dental implant in maxillary posterior area using cone beam CT. Patients and Method: One hundred five maxillary sinuses in eighty-seven patients who underwent cone beam CT for dental implant in maxillary posterior area were included. Any patients who had previous history of sinus operations were not included. The sinus abnormalities were classified as follows ; normal (membrane thickness <2 mm), mucosal thickening (membrane thickness ${\geq}$ 2 mm and < 6 mm), partial opacification (membrane thickness > 6 mm but not full), full opacification and mucous retention cyst. The relationship between the remaining bone height, sinus symptoms and maxillary sinus abnormality was statistically surveyed. Results: Of 105 maxillary sinuses in 87 patients, 80 (76%) maxillary sinuses showed abnormalities ; 4 of 4 symptomatic patients and 76 of 101 asymptomatic patients. Mucosal thickening was the most common sinus abnormality. Only 3 (4%) of 80 maxillary sinus abnormalities were caused by the odontogenic origin. The prevalence of maxillary sinus abnormalities was higher in the symptomatic group than asymptomatic one (p<0.05). Conclusion: Maxillary sinus abnormalities were very common in the patients who were planning implantation in maxillary posterior areas. This result supports that thorough evaluation for maxillary sinus is recommended when implant treatment is planned for those areas.
The Journal of Korean Society for Radiation Therapy
/
v.24
no.1
/
pp.15-21
/
2012
Purpose: Image Guided Radiation Therapy (IGRT) has been carried out using On-Board Imager system (OBI) in Asan Medical Center. For this reason, This study was to analyze and evaluate the impact on Cone-Beam CT according to variation of material and respiration. Materials and Methods: This study was to acquire and analyze Cone-Beam CT three times for two material: Cylider acryl (lung equvalent material, diameter 3 cm), Fiducial Marker (using clinic) under Motion Phantom able to adjust respiration pattern randomly was varying period, amplitude and baseline vis-a-vis reference respiration pattern. Results: First, According to a kind of material, when being showed 100% in the acryl and 120% in the Fiducial Marker under the condition of same movement of the motion phantom. Second, According to the respiratory alteration, when being showed 1.13 in the baseline shift 1.8 mm and 1.27 in the baseline shift 3.3 mm for acryl. when being showed 1.01 in 1 sec of period and 1.045 in 2.5 sec of period for acryl. When being showed 0.86 in 0.7 times the standard of amplitude and 1.43 in 1.7 times the standard of amplitude for acryl. when being showed 1.18 in the baseline shift 1.8 mm and 1.34 in the baseline shift 3.3 mm for Fiducial Marker. when being showed 1.0 in 1 sec of period and 1.0 in 2.5 sec of period for Fiducial Marker. When being showed 0.99 in 0.7 times the standard of amplitude and 1.66 in 1.7 times the standard of amplitude for Fiducial Marker. Conclusion: The effect of image size of CBCT was 20% in the case of Fiducial marker. The impact of changes in breathing pattern was minimum 13% - maximum 43% for Arcyl, min. 18% - max. 66% for Fiducial marker. This difference makes serious uncertainty. So, Must be stabilized breathing of patient before acquiring CBCT. also must be monitored breathing of patient in the middle of acquire. If you observe considerable change of breathing when acquiring CBCT. After Image Guided, must be need to check treatment site using fluoroscopy. If a change is too big, re-acquiring CBCT.
This paper presents a new fast algorithm, rotation-based method (RBM), for the reconstruction of 3 dimensional image for cone beam computerized tomography (CB CT) system. The system used cone beam has less exposure time of radioactivity than fan beam. The Three-Pass Shear Matrices (TPSM) is applied, that has less transcendental functions than the one-pass shear method to decrease a time of calculations in the computer. To evaluate the quality of the 3-D images and the time for the reconstruction of the 3-D images, another 3-D images were reconstructed by the radon transform under the same condition. For the quality of the 3-D images, the images by radon transform was shown little good quality than REM. But for the time for the reconstruction of the 3-D images REM algorithm was 35 times faster than radon transform. This algorithm offered $4{\sim}5$ frames a second. It meant that it will be possible to reconstruct the 3-D dynamic images in real time.
Objective: To investigate the diagnostic accuracy and complications of cone-beam CT-guided percutaneous transthoracic needle biopsy (PTNB) of juxtaphrenic lesions and identify the risk factors for diagnostic failure and complications. Materials and Methods: In total, 336 PTNB procedures for lung lesions (mean size ± standard deviation [SD], 4.3 ± 2.3 cm) abutting the diaphragm in 326 patients (189 male and 137 female; mean age ± SD, 65.2 ± 11.4 years) performed between January 2010 and December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PTNB procedures for the diagnosis of malignancy were measured based on the intention-to-diagnose principle. The risk factors for diagnostic failures and complications were evaluated using logistic regression analysis. Results: The accuracy, sensitivity, specificity, PPV, and NPV were 92.7% (293/316), 91.3% (219/240), 91.4% (74/81), 96.9% (219/226), and 77.9% (74/95), respectively. There were 23 diagnostic failures (7.3%), and lesion sizes ≤ 2 cm (p = 0.045) were the only significant risk factors for diagnostic failure. Complications occurred in 98 cases (29.2%), including 89 cases of pneumothorax (26.5%) and 7 cases of hemoptysis (2.1%). The multivariable analysis showed that old age (> 65 years) (p = 0.002), lesion size of ≤ 2 cm (p = 0.003), emphysema (p = 0.006), and distance from the pleura to the target lesion (> 2 cm) (p = 0.010) were significant risk factors for complications. Conclusion: The diagnostic accuracy of cone-beam CT-guided PTNB of juxtaphrenic lesions for malignancy was fairly high, and the target lesion size was the only significant predictor of diagnostic failure. Complications of cone-beam CT-guided PTNB of juxtaphrenic lesions occurred at a reasonable rate.
Ahn, Beom Seok;Wu, Hong-Gyun;Yoo, Sook Hyun;Park, Jong Min
Journal of Radiation Protection and Research
/
v.40
no.1
/
pp.17-24
/
2015
To improve accuracy of dose calculation on kilovoltage cone beam computed tomography (kV CBCT) images, a custom-made phantom was fabricated to acquire an accurate CT number to electron density curve by full scatter of cone beam x-ray. To evaluate the dosimetric accuracy, 9 volumetric modulated arc therapy (VMAT) plans for head and neck (HN) cancer and 9 VMAT plans for lung cancer were generated with an anthropomorphic phantom. Both CT and CBCT images of the anthropomorphic phantom were acquired and dose-volumetric parameters on the CT images with CT density curve (CTCT), CBCT images with CT density curve ($CBCT_{CT}$) and CBCT images with CBCT density curve ($CBCT_{CBCT}$) were calculated for each VMAT plan. The differences between $CT_{CT}$ vs. $CBCT_{CT}$ were similar to those between $CT_{CT}$ vs. $CBCT_{CBCT}$ for HN VMAT plans. However, the differences between $CT_{CT}$ vs. $CBCT_{CT}$ were larger than those between $CT_{CT}$ vs. $CBCT_{CBCT}$ for lung VMAT plans. Especially, the differences in $D_{98%}$ and $D_{95%}$ of lung target volume were statistically significant (4.7% vs. 0.8% with p = 0.033 for $D_{98%}$ and 4.8% vs. 0.5% with p = 0.030 for $D_{95%}$). In order to calculate dose distributions accurately on the CBCT images, CBCT density curve generated with full scatter condition should be used especially for dose calculations in the region of large inhomogeneity.
Purpose: This study was performed to investigate the characteristics of mandibular incisive canal (MIC) in Korean population. Materials and methods: A total of 97 subjects (60 males and 37 females) who underwent cone-beam computed tomography were included in the study. The anatomic features of MIC was assessed according to gender. Length, diameter and distance to inferior, lingual and buccal border were measured at the origin and the terminal. Also the distribution of MIC at each tooth position was evaluated. Results: Of 97 patients included, 75(77.3%) presented bilateral MIC and 13(13.4%) presented unilateral MIC. Of 194 hamimandibles, MIC was detected in 102(85%) sites in male and 61(82.4%) sites in female. Gender and side showed no statistically significant differences in detectability. The length, diameter and distance to adjacent structures were bigger in male than in female except the distance to lingual border. MIC travelled anteriorly in a slightly downward and lingual direction and usually terminated between the first premolar and the canine. On cross-sectional view, MIC showed individually scattered distribution both buccolingually and superoinferiorly. Conclusion: MIC is well detected with cone-beam computed tomography. Considered that the length and the location of MIC has large variations between individuals, its localization using cone-beam CT is highly recommended before performing surgical procedures such as implant placement and bone harvesting.
Wang, Zhi-Jun;Wang, Mao-Qiang;Duan, Feng;Song, Peng;Liu, Feng-Yong;Wang, Yan;Yan, Jie-Yu;Li, Kai;Yuan, Kai
Asian Pacific Journal of Cancer Prevention
/
v.14
no.3
/
pp.1649-1654
/
2013
Objective: This work aimed to evaluate the safety and clinical efficacy of transcatheter arterial chemoembolization (TACE) combined with c-arm cone-beam CT guided synchronous radiofrequency ablation (RFA) in treatment of large hepatocellular carcinoma (HCC). Methods: 21 patients with large HCC were studied from January 2010 to March 2012. TACE combined with synchronous C-arm cone-beam CT guided RFA were performed on a total of 25 lesions. Conventional imaging examination (CEUS, enhanced CT or MRI) and AFP detection were regularly conducted to evaluate the technical success rate of combined treatment, complications, treatment response, time without disease recurrence and survival rate. Results: The technical success rate of combined treatment was 100%, without any significant complication. After 1 month, there were 19 cases with complete response and 2 cases with partial response, with an complete response rate of 90.4% (19/21) and a clinical effective rate of 100% (21/21). The complete response rates of single nodular lesions (100%, 17/17) was significantly higher than that of multiple nodular lesions (50%, 2/4) (P<0. 05). During 2 to 28 months of follow-up, in 19 cases with complete response, the average time without disease recurrence was $10.8{\pm}6$ months. The total survival rates of 6, 12 and 18 months in 21 patients were 100%, respectively. Conclusion: TACE combined with synchronous C-arm CT guided RFA is safe and effective for treatment of large HCC. The treatment efficacy for single nodular lesion is better than that for multiple nodular lesions.
To evaluate the radiation exposure level based on radiation workers' locations in dental radiography, the radiation dose rate in the radiographic room, lead glass, and operation system was measured. To that end, various devices were used, such as a Standard(Max-GLS, Shinhung), a panorama (PCH-2500, Vatech), a cephalometric radiography (PCH-2500), and a cone beam CT (PHT-30LFO, Vatech), as well as a PM1405 equipment as a radiation meter. Radiography conditions were set the same as the factors used in the clinical setting. As the result, the cone beam CT turned out the highest with 98 uSv and the standard showed the lowest level with 0.4 uSv/h. The panorama was measured to be higher than the Cephalo due to its different focus mode. On the lead glass surface and in the operation stand, the oral radiography device, panoramic, and Cephalo all were measured below the recording level. However, the cone beam CT was measured to have the leakage dose. Thus, radiation involved workers should be equipped with appropriate protection tools and reduce radiography time as much as possible. In addition, the structure of the radiation chamber should be also designed efficiently. Dental radiography has continued to grow in recent years, so it is necessary take appropriate protection measures for patients and radiation workers.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.