• Title/Summary/Keyword: Cone Beam

Search Result 978, Processing Time 0.031 seconds

Characterization of Cone-beam Computed Tomography System for Small Animal (콘빔형 소동물용 전산화단층촬영(CT) 장치의 성능평가)

  • Kang, Hyeong-Geun;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.1
    • /
    • pp.19-24
    • /
    • 2010
  • A cone-beam computed tomography (CT) system for a small animal has been widely used in the bio-medical application. This paper introduced simple methods for evaluating a cone-beam CT system using a simple tungsten wire phantom of 10{$\mu}m$ diameter and a water phantom. Slice images and three-dimensional tomography images were obtained through 360 projection views per one sample rotation under stable X-ray tube conditions for a long running time. The cone-beam CT system at a position of a 1.07 magnification showed a spatial frequency of 13.78 lp/mm ($36.2{\mu}m$ spatial resolution) and gave a CNR of 10.33 and a S/N of 5.87 under a tube voltage of 80kV.

Reliability of panoramic radiography in predicting proximity of third molars to the mandibular canal: A comparison using cone-beam computed tomography

  • Nunes, Willy James Porto;Vieira, Aline Lisboa;de Abreu Guimaraes, Leticia Drumond;de Alcantara, Carlos Eduardo Pinto;Verner, Francielle Silvestre;de Carvalho, Matheus Furtado
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.9-16
    • /
    • 2021
  • Purpose: The purpose of this study was to analyze the reliability of 7 panoramic radiographic signs for predicting proximity of the root apices of mandibular third molars to the mandibular canal using cone-beam computed tomography and to correlate these findings with the Pell and Gregory and the Winter classification systems. Materials and Methods: An observational, cross-sectional, descriptive study was conducted on 74 patients with bilateral impacted mandibular third molars. Four panoramic radiographic signs were observed in the tooth root (darkening, deflection, and narrowing of the root apices, and bifid apices), and another 3 in the mandibular canal (diversion, narrowing, and interruption of the mandibular canal). Cone-beam computed tomography images were analyzed to identify disruption and diversion of the mandibular canal and root deflection. Results: Binary logistic regression showed that only 4 of the 7 panoramic radiographic signs were able to predict proximity of the root apices of the mandibular third molars to the mandibular canal: darkening of the root, deflection of the root, narrowing of the root, and interruption of the mandibular canal(P<0.05). Conclusion: Darkening, deflection, and narrowing of the root, in tandem with the interruption of the mandibular canal on panoramic radiographs, indicate that cone-beam computed tomography should be performed when planning the extraction of impacted mandibular third molars. Proximity between mandibular third molars and the mandibular canal is correlated with the Winter classification.

A cone-beam computed tomography study of the prevalence and location of the second mesiobuccal root canal in maxillary molars

  • Seong-Ju Lee ;Eun-Hye Lee ;Se-Hee Park ;Kyung-Mo Cho ;Jin-Woo Kim
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.4
    • /
    • pp.46.1-46.8
    • /
    • 2020
  • Objectives: This study aimed to investigate the incidence and location of the second mesiobuccal root (MB2) canal in maxillary molars with the aid of various measuring points and lines using cone-beam computed tomography (CT). Materials and Methods: A total of 205 images of patients who underwent cone-beam CT examinations between 2011 and 2015 as part of their dental diagnosis and treatment were included. There were 76 images of the maxillary first molar and 135 images of the maxillary second molar. Canal orifices were detected at -1 mm from the top of the pulpal floor on cone-beam CT images. Image assessment was performed by 2 observers in reformatted image planes using software. Assessments included measurement of the distance between the MB1 and MB2 canals, and the angles between the lines connecting the MB1-MB2 and distobuccal (DB)-palatal (P) canals. The data were analyzed using the student's t-test. Results: The prevalence of the MB2 canal was 86.8% in the first molar and 28.9% in the second molar. The angle between the lines connecting the MB1-MB2 and DB-P canals was 2.3° ± 5.7° in the first molar and -3.95° ± 7.73° in the second molar. The distance between the MB1 and MB2 canals was 2.1 ± 0.44 mm in the first molar and 1.98 ± 0.42 mm in the second molar. Conclusions: The angles between the lines connecting the MB1-MB2 and DB-P canals was almost parallel. These findings may aid in the prediction of the location of the MB2 canal orifice.

Cone-Beam CT-Guided Percutaneous Transthoracic Needle Lung Biopsy of Juxtaphrenic Lesions: Diagnostic Accuracy and Complications

  • Wonju Hong;Soon Ho Yoon;Jin Mo Goo;Chang Min Park
    • Korean Journal of Radiology
    • /
    • v.22 no.7
    • /
    • pp.1203-1212
    • /
    • 2021
  • Objective: To investigate the diagnostic accuracy and complications of cone-beam CT-guided percutaneous transthoracic needle biopsy (PTNB) of juxtaphrenic lesions and identify the risk factors for diagnostic failure and complications. Materials and Methods: In total, 336 PTNB procedures for lung lesions (mean size ± standard deviation [SD], 4.3 ± 2.3 cm) abutting the diaphragm in 326 patients (189 male and 137 female; mean age ± SD, 65.2 ± 11.4 years) performed between January 2010 and December 2014 were included. The accuracy, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PTNB procedures for the diagnosis of malignancy were measured based on the intention-to-diagnose principle. The risk factors for diagnostic failures and complications were evaluated using logistic regression analysis. Results: The accuracy, sensitivity, specificity, PPV, and NPV were 92.7% (293/316), 91.3% (219/240), 91.4% (74/81), 96.9% (219/226), and 77.9% (74/95), respectively. There were 23 diagnostic failures (7.3%), and lesion sizes ≤ 2 cm (p = 0.045) were the only significant risk factors for diagnostic failure. Complications occurred in 98 cases (29.2%), including 89 cases of pneumothorax (26.5%) and 7 cases of hemoptysis (2.1%). The multivariable analysis showed that old age (> 65 years) (p = 0.002), lesion size of ≤ 2 cm (p = 0.003), emphysema (p = 0.006), and distance from the pleura to the target lesion (> 2 cm) (p = 0.010) were significant risk factors for complications. Conclusion: The diagnostic accuracy of cone-beam CT-guided PTNB of juxtaphrenic lesions for malignancy was fairly high, and the target lesion size was the only significant predictor of diagnostic failure. Complications of cone-beam CT-guided PTNB of juxtaphrenic lesions occurred at a reasonable rate.

Correlation between cone-beam computed tomographic findings and the apnea-hypopnea index in obstructive sleep apnea patients: A cross-sectional study

  • Marco Isaac;Dina Mohamed ElBeshlawy;Ahmed Elsobki;Dina Fahim Ahmed;Sarah Mohammed Kenawy
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.147-157
    • /
    • 2024
  • Purpose: The aim of this study was to explore the correlations of cone-beam computed tomographic findings with the apnea-hypopnea index in patients with obstructive sleep apnea. Materials and Methods: Forty patients with obstructive sleep apnea were selected from the ear-nose-throat (ENT) outpatient clinic, Faculty of Medicine, Mansoura University. Cone-beam computed tomography was performed for each patient at the end of both inspiration and expiration. Polysomnography was carried out, and the apnea-hypopnea index was obtained. Linear measurements, including cross-sectional area and the SNA and SNB angles, were obtained. Four oral and maxillofacial radiologists categorized pharyngeal and retropalatal airway morphology and calculated the airway length and volume. Continuous data were tested for normality using the Kolmogorov-Smirnov test and reported as the mean and standard deviation or as the median and range. Categorical data were presented as numbers and percentages, and the significance level was set at P<0.05. Results: The minimal value of the cross-sectional area, SNB angle, and airway morphology at the end of inspiration demonstrated a statistically significant association (P<0.05) with the apnea-hypopnea index, with excellent agreement. No statistically significant difference was found in the airway volume, other linear measurements, or retropalatal airway morphology. Conclusion: Cone-beam computed tomographic measurements in obstructive sleep apnea patients may be used as a supplement to a novel radiographic classification corresponding to the established clinical apnea-hypopnea index classification.

Analysis of Beam Hardening of Modulation Layers for Dual Energy Cone-beam CT (에너지 변조 필터로 구현한 이중 에너지 콘빔 CT의 에너지 스펙트럼 평가 연구)

  • Ahn, Sohyun;Cho, Sam Ju;Keum, Ki Chang;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Dual energy cone-beam CT can distinguish two materials with different atomic compositions. The principle of dual energy cone-beam CT based on modulation layer is that higher energy spectrum can be acquired at blocked x-ray window. To evaluate the possibility of modulation layer based dual energy cone-beam CT, we analyzed x-ray spectrum for various thicknesses of modulation layers by Monte Carlo simulation. To compare with the results of simulation, the experiment was performed on prototype cone-beam CT for 50~100 kVp with CdTe XR-100T detector. As the result of comparing, the mean energy of energy spectrum for 80 kVp are well matched with that of simulation. The mean energy of energy spectrum for 80 and 120 kVp were increased as 1.67 and 1.52 times by 2.0 mm modulation layer, respectively. We realized that the virtual dual energy x-ray source can be generated by modulation layer.

Consideration of the Effect according to Variation of Material and Respiration in Cone-Beam CT (Cone-Beam CT에서 물질 및 호흡 변화가 영상에 미치는 영향에 대한 고찰)

  • Na, Jun-Young;Kim, Jung-Mi;Kim, Dae-Sup;Kang, Tae-Young;Baek, Geum-Mun;Kwon, Gyeong-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.1
    • /
    • pp.15-21
    • /
    • 2012
  • Purpose: Image Guided Radiation Therapy (IGRT) has been carried out using On-Board Imager system (OBI) in Asan Medical Center. For this reason, This study was to analyze and evaluate the impact on Cone-Beam CT according to variation of material and respiration. Materials and Methods: This study was to acquire and analyze Cone-Beam CT three times for two material: Cylider acryl (lung equvalent material, diameter 3 cm), Fiducial Marker (using clinic) under Motion Phantom able to adjust respiration pattern randomly was varying period, amplitude and baseline vis-a-vis reference respiration pattern. Results: First, According to a kind of material, when being showed 100% in the acryl and 120% in the Fiducial Marker under the condition of same movement of the motion phantom. Second, According to the respiratory alteration, when being showed 1.13 in the baseline shift 1.8 mm and 1.27 in the baseline shift 3.3 mm for acryl. when being showed 1.01 in 1 sec of period and 1.045 in 2.5 sec of period for acryl. When being showed 0.86 in 0.7 times the standard of amplitude and 1.43 in 1.7 times the standard of amplitude for acryl. when being showed 1.18 in the baseline shift 1.8 mm and 1.34 in the baseline shift 3.3 mm for Fiducial Marker. when being showed 1.0 in 1 sec of period and 1.0 in 2.5 sec of period for Fiducial Marker. When being showed 0.99 in 0.7 times the standard of amplitude and 1.66 in 1.7 times the standard of amplitude for Fiducial Marker. Conclusion: The effect of image size of CBCT was 20% in the case of Fiducial marker. The impact of changes in breathing pattern was minimum 13% - maximum 43% for Arcyl, min. 18% - max. 66% for Fiducial marker. This difference makes serious uncertainty. So, Must be stabilized breathing of patient before acquiring CBCT. also must be monitored breathing of patient in the middle of acquire. If you observe considerable change of breathing when acquiring CBCT. After Image Guided, must be need to check treatment site using fluoroscopy. If a change is too big, re-acquiring CBCT.

  • PDF

Comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars (하악 제3대구치와 하악관과의 위치관계에 대한 파노라마 방사선사진과 cone beam형 전산화단층촬영상의 비교)

  • Choi, Hyung-Soo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.38 no.3
    • /
    • pp.169-176
    • /
    • 2008
  • Purpose : To assess the diagnostic accuracy and value in an imaging technique field through the comparison of cone beam computed tomography and conventional panoramic radiography in assessing the topographic relationship between the mandibular canal and impacted third molars. Materials and Methods : Participants consisted of 100 patients offered the images through cone beam computed tomography and panoramic radiography. PSR-$9000^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Japan) was used as the unit of cone beam computed tomography. CE-II (Asahi Roentgen Ind. Co., Ltd, Japan) and Pro Max (Planmeca Oy, Finland) were used as the unit of panoramic radiography. The images obtained through panoramic radiography were classified into 3 types according to the distance between mandibular canal and root of mandibular third molar. And they were classified into 4 types according to the proximity of radiographic feature. The images obtained through cone beam computed tomography based on the classification above were classified into 4 types according to the location between the mandibular canal and the root and were analyzed. And they were classified into buccal, inferior, lingual, and between roots, according to the location between mandibular canal and root. The data were statistically analyzed and estimated by $X^2$-test. Results : 1. There was no statistical significance according to 3 types (type I, type II, type III) through CBCT. 2. The results of 4 types (type A, type B, type C, type D) through CBCT were as high prevalence of CBCT 1 in type A, CBCT 2 in type B, CBCT 3 in type C, and CBCT1 in type D and those of which showed statistical significance (P value=0.03). 3. The results according to location between mandibular canal and root through CBCT recorded each 49, 25, 17, 9 as buccal, inferior, lingual, between roots. Conclusion : When estimating the mandibular canal and the roots through the panoramic radiography, it could be difficult to drive the views of which this estimation was considerable. Thus it is required to have an accurate diagnostic approaching through CBCT that could estimate the location between mandibular canal and roots.

  • PDF

Three-dimensional imaging modalities in endodontics

  • Mao, Teresa;Neelakantan, Prasanna
    • Imaging Science in Dentistry
    • /
    • v.44 no.3
    • /
    • pp.177-183
    • /
    • 2014
  • Recent research in endodontics has highlighted the need for three-dimensional imaging in the clinical arena as well as in research. Three-dimensional imaging using computed tomography (CT) has been used in endodontics over the past decade. Three types of CT scans have been studied in endodontics, namely cone-beam CT, spiral CT, and peripheral quantitative CT. Contemporary endodontics places an emphasis on the use of cone-beam CT for an accurate diagnosis of parameters that cannot be visualized on a two-dimensional image. This review discusses the role of CT in endodontics, pertaining to its importance in the diagnosis of root canal anatomy, detection of periradicular lesions, diagnosis of trauma and resorption, presurgical assessment, and evaluation of the treatment outcome.

Patient radiation dose and protection from cone-beam computed tomography

  • Li, Gang
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.63-69
    • /
    • 2013
  • After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from $19{\mu}Sv$ to $1073{\mu}Sv$ and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply understand the potential risk from CBCT, this report also reviewed the effective doses from literatures on intra-oral radiograph, panoramic radiograph, lateral and posteroanterior cephalometric radiograph, multi-slice CT, and so on. The protection effect of thyroid collar and leaded glasses were also reviewed.