On the effect of void ratio and particle breakage on saturated hydraulic conductivity of tailing materials

  • Ma, Changkun;Zhang, Chao;Chen, Qinglin;Pan, Zhenkai;Ma, Lei
    • Geomechanics and Engineering
    • /
    • 제25권2호
    • /
    • pp.159-170
    • /
    • 2021
  • Particle size of tailings in different areas of dams varies due to sedimentation and separation. Saturated hydraulic conductivity of high-stacked talings materials are seriously affected by void ratio and particle breakage. Conjoined consolidation permeability tests were carried out using a self-developed high-stress permeability and consolidation apparatus. The hydraulic conductivity decreases nonlinearly with the increase of consolidation pressure. The seepage pattern of coarse-particle tailings is channel flow, and the seepage pattern of fine-particle tailings is scattered flow. The change rate of hydraulic conductivity of tailings with different particle sizes under high consolidation pressure tends to be identical. A hydraulic conductivity hysteresis is found in coarse-particle tailings. The hydraulic conductivity hysteresis is more obvious when the water head is lower. A new hydraulic conductivity-void ratio equation was derived by introducing the concept of effective void ratio and breakage index. The equation integrated the hydraulic conductivity equation with different particle sizes over a wide range of consolidation pressures.

수두손실률, 투수계수 및 공극비의 상호관계를 통한 제체의 다짐상태 평가 (The Estimation of Compacted State on Sea Dike Embankment with the Interrelationships Between the Hydraulic Head Loss Rate, the Hydraulic Conductivity and the Void Ratio)

  • 임성훈
    • 한국농공학회논문집
    • /
    • 제57권1호
    • /
    • pp.11-23
    • /
    • 2015
  • In this study the laboratory test for hydraulic conductivity and the seepage analysis with finite element method on measurement section of sea dike embankment were performed for the purpose of estimating the relative density of embankment from the measured pore water pressures, and both results of the test and the analysis were coupled with the method of estimating seepage blocking state with the hydraulic head loss rate in sea dike embankment. The relationship of void ratio vs hydraulic head loss rate was obtained by setting hydraulic conductivity as common ordinate on the relationships between the void ratio and the hydraulic conductivity and between the hydraulic conductivity and the hydraulic head loss rate. The void ratio on the segment between measuring points was calculated from the coupled relationship of the void ratio vs the hydraulic conductivity. The allowable upper and lower limits of hydraulic head loss rate and those of void ratio on the safety were generated from the coupled relationship between the laboratory compaction test and the sedimentation test. Current hydraulic head loss rate and void ratio were evaluated in the allowable range between upper and lower limits.

펄라이트 치환율에 따른 경량복합패널 심재의 밀도 및 열전도율 특성 (Density and Thermal Conductivity Property of the Lightweight Composite Panel Core According to Pearlite Replacement ratio)

  • 김헌태;정병열;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.175-176
    • /
    • 2014
  • Recently, in the apartment house of our country, office building, apartment, and etc, the lightweight composite panel is much used as the partition wall body. This is due to be very convenient when the execution and dismantling is convenient and it forms the space which the consumer in the space desires. Therefore, in this research, the thermal conductivity property of the lightweight composite panel core according to the replacement ratio variation of the pearlite tries to be analyze. As the density test result and replacement ratio of the pearlite increased, the density showed the tendency to rise. the replacement ratio of the pearlite increased, the absorption rate showed the tendency to fall. And this is determined that absorption rate is degraded due to the increase in the density. the thermal conductivity test result and pearlite replacement ratio increased, the tendency that the thermal conductivity increases was represented.

  • PDF

A Study on the Effective Hydraulic Conductivity of an Anisotropic Porous Medium

  • Seong, Kwanjae
    • Journal of Mechanical Science and Technology
    • /
    • 제16권7호
    • /
    • pp.959-965
    • /
    • 2002
  • Effective hydraulic conductivity of a statistically anisotropic heterogeneous medium is obtained for steady two-dimensional flows employing stochastic analysis. Flow equations are solved up to second order and the effective conductivity is obtained in a semi-analytic form depending only on the spatial correlation function and the anisotropy ratio of the hydraulic conductivity field, hence becoming a true intrinsic property independent of the flow field. Results are obtained using a statistically anisotropic Gaussian correlation function where the anisotropy is defined as the ratio of integral scales normal and parallel to the mean flow direction. Second order results indicate that the effective conductivity of an anisotropic medium is greater than that of an isotropic one when the anisotropy ratio is less than one and vice versa. It is also found that the effective conductivity has upper and lower bounds of the arithmetic and the harmonic mean conductivities.

Carbon 화이버-폴리머 복합체의 전기적 특성 (Electrical Conductivity of Carbon Fiber-Polymer Composite)

  • 이재연;최경만
    • 한국세라믹학회지
    • /
    • 제35권6호
    • /
    • pp.603-609
    • /
    • 1998
  • The composites of insulating polymer filled with conducting carbon-fiber were fabricated by molding press method. To understand the fiber aspect-ratio dependence of electrical conductivity the aspect ratio was varied from 4 to 10 The percolation thresholds of transition from the insulator to the conductor de-creased as the fiber aspect ratio increased. The percolation threshold of fiber-segregated composite in this study was smaller than that of fiber-random composite shown in other study. When the electrical con-ductivity curves were fitted by general effective medium equation morphological variable(t) decreased as the fiber aspect-ratio increased.

  • PDF

벽에서 열원이 있는 수직채널안의 자연대류열전달 (Free Convective Heat Transfer in a Vertical Channel with Heat Source at the Wall)

  • 박희용;두민수
    • 대한설비공학회지:설비저널
    • /
    • 제14권2호
    • /
    • pp.108-117
    • /
    • 1985
  • In this study, a numerical analysis was performed for the natural convection heat transfer in a vertical channel which was consisted of two finite-thickness vertical walls with heat source. The ratio of the thermal conductivity of wall to air played an important role in the analysis. The case for which one side wall has protrusion resistances was also examined. The governing equations for the system was discretized by control volume formulation and solved by SIMPLE method. As the result of this study, it was found that the uniform heat flux boundary condition could be applied when the conductivity ratio was below approximately 50 and the uniform temperature boundary condition could be used when the conductivity rat io was over approximately 15,000. However, when the conductivity ratio was between 50 and 15,000, the thermal conductivity ratio value should be considered for the analysis. It was also found that the existence of protrusion resistance influenced the thermal field up to the distance of 3-4 times of the protrusion length.

  • PDF

Effect of SiO2/B2O3 ratio on Li ion conductivity of a Li2O-B2O3-SiO2 glass electrolyte

  • Kim, Young Han;Yoon, Mi Young;Lee, Eun Jung;Hwang, Hae Jin
    • Journal of Ceramic Processing Research
    • /
    • 제13권spc1호
    • /
    • pp.37-41
    • /
    • 2012
  • A lithium ion conducting borosilicate glass was fabricated by a conventional melt quenching technique from a mixture of Li2CO3, B2O3 and SiO2 powders. The Li ion conductivity of the lithium borosilicate glasses was evaluated in terms of the SiO2/B2O3 ratio. In the Li2O-B2O3-SiO2 ternary glass, the glass forming region decreases with an increasing Li2O content. At the same Li2O, the crystallization tendency of the glass samples increases with the SiO2/B2O3 ratio, resulting in a reduced glass forming region in the Li2O-B2O3-SiO2 ternary glass. The electrical conductivity moderately depends on the SiO2/B2O3 ratio in the Li2O-B2O3-SiO2 ternary glass. The conductivity of the glasses slightly increases with the SiO2/B2O3 ratio. The observed phenomenon can be explained by the modification of the glass structure as a function of the SiO2 content.

雨水採取機가 雨水成分에 미치는 影響 (Effects of Rain Water Sampler on the Results of Analysis)

  • 李敏熙;韓義正;辛燦基;韓振錫
    • 한국대기환경학회지
    • /
    • 제3권2호
    • /
    • pp.53-61
    • /
    • 1987
  • Automatic and manual rain smaplers wre installed at the roof of National Institute of Environmental Research (NIER), and the rain sampling and measurement were conducted during the period April to August 31, 1987. The rain sampling and measurement were carried out in the following manners: The 1st : Acidity and conductivity were measured entirely by automatic rain sampler (continuous measurement) The 2nd : Acidity and conductivity wrer measured in the laboratory with the sample that was taken out of automatic rain sampler. The 3rd : Acidity and conductivity were measured in the laboratory with the sample that was taken out of manual rain sampler. Afterwards, those different measurement values were compared each other and the following conclusions were obtained: 1) The pH of the continous measurement by the automatic sampler was lower than that of the laboratory measurement, and it was reversed in case of the conductivity. 2) The significance was recognized at 5% risk ratio for the population mean of difference of the measurement values of the pH and conductivity from both samples. 3) The significance was not recognized at 5% risk ratio by the analysis of variance by one way layout for the pH and conductivity. 4) The significance was recognized at 5% risk ratio by the analysis of variance by two way layouts for the pH conductivity. 5) The significance was recognized at 5% rrisk ratio for the differences of the pH values obtained by oboth samplers, and no significance was recognized for conductivity. 6) In comparison of the measurement values from the two samplers were shown a good correlation for pH; correlation coefficient (r) = 0.63, and regression equation Y = 0.53X + 2.78. For conductivity, the correlation was also excellent; correlation coefficient (r) = 0.53 and regression equation Y = 0.63X + 5.65.

  • PDF

경량골재를 사용한 콘크리트 복합체의 단열성능에 관한 연구 (A Study on the Thermal Insulation Property of Concrete Composites using Light-weight Aggregate)

  • 소승영
    • 한국건축시공학회지
    • /
    • 제4권3호
    • /
    • pp.93-100
    • /
    • 2004
  • In recent years, it has widely been studied on the light-weight composites for the purpose of the large space and thermal insulation of building structures. The purpose of this study is to evaluate the properties of light-weight composites made by binders as cement, resin and polymer cement slurry. The concrete composites are prepared with various conditions such as polymer-cement ratio, void-filling ratio, type of resin, filler content and light-weight aggregate content, tested for thermal conductivity. From the test results, the thermal conductivity of concrete composites with the binder of cement tends to decrease with increasing polymer-cement ratio, and to increase with increasing void-filling ratio. The thermal conductivity of concrete composites with the binder of resin are markedly affected by the light-weight aggregate content, type of resin and filler content. The composites made by polymer-modified concrete and polymer cement slurry have a good thermal insulation property. From the this study, we can recommend the proper mix proportions for thermal insulation Panel or concrete. Expecially. the thermal conductivity of concrete composites made by polyurethane resin is almost the same as that of the conventional expanded polystyrene resin.

EPS Bead 혼입비율에 따른 CLC의 단열특성 (Insulation Properties of CLC according to Mixing Ratio of EPS Bead)

  • 이정택;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.45-46
    • /
    • 2023
  • CLC is used as a filling material for many buildings, and according to energy saving design standards, CLC also requires insulation performance. However, it shows lower insulation performance compared to organic insulation, so additional research is needed. Therefore, in this study, the insulation properties of CLC were analyzed by incorporating EPS beads with high insulation performance into CLC. In this experiment, EPS beads and blast furnace slag were replaced, and W/B was fixed at 33%. The EPS Bead mixing ratio was divided into 5 levels: 0, 0.5, 1.0, 1.5, 2.0 (%), and the experimental items were measured for apparent density and thermal conductivity. As a result of the experiment, the apparent density and thermal conductivity tended to decrease as the mixing ratio of EPS beads increased. It is judged that the density decreased due to the low density and the micropores inside, and the thermal conductivity also decreased.

  • PDF