• 제목/요약/키워드: Conduction loss

검색결과 446건 처리시간 0.033초

Effect of Chromium Chloride on the Mechanical and Dielectric Properties of EPDM Rubber

  • Salem, M.A.;Khaled, M.A.;Hussein, A.M.;Elway, E.
    • Macromolecular Research
    • /
    • 제11권4호
    • /
    • pp.256-259
    • /
    • 2003
  • Measurements of Young's modulus, dielectric loss and a.c. conductivity have been carried out on EPDM rubber samples loaded with different concentrations of $CrCl_3$ (0,2,4 and 6 phr). The values of Young's modulus was found to be linearly dependent on the $CrCl_3$ content. Variation of the dielectric loss with temperature showed that $CrCl_3$ may act as plasticizer. However, at higher frequencies the dielectric loss was found to be independent of frequency and the rubber samples may behave as non-polar dielectric. Investigations of the a.c conductivity suggested that the conduction in these rubber samples can be described by small polaron tunneling. In addition, conductivity was found to increase with $CrCl_3$ content.

전자장비에서 벽면의 대류열방출 및 통기구의 효과를 고려한 3차원 자연대류 냉각 (Three-dimensional natural convection cooling of the electronic device with the effects of convective heat dissipation and vents)

  • 이관수;백창인;임광옥
    • 대한기계학회논문집
    • /
    • 제19권11호
    • /
    • pp.3072-3083
    • /
    • 1995
  • The numerical simulation on the three-dimensional natural convection heat transfer in the enclosure with heat generating chip is performed, and the effects of convective heat loss and vents are also examined. The effects of the Rayleigh number and outer Nusselt number (Nu$_{0}$) on the maximum chip temperature and the fractions of heat loss from the hot surfaces are investigated. The results show that conduction through the substrate is dominant in heat dissipation. With the increase of Rayleigh number, heat dissipation through the chip surfaces increases and heat loss through the substrate decreases. Maximum dimensionless temperature with vents is found to decrease about 40% compared to the one without vents at Nu$_{0}$=0.l. It is also shown that effects of size and location of the vents are negligible.ble.

스위칭 소자의 전도손실과 스트레스를 저감하기 위한 디지털 위상천이 공진형 컨버터에 관한 연구 (A Study of the Digital Phase-shift Resonant Converter to Reduce the conduction Loss and Stress of the Switching Device)

  • 신동률;황영민;김동완;우정인
    • 전기학회논문지P
    • /
    • 제51권1호
    • /
    • pp.10-17
    • /
    • 2002
  • Due to the development of information communication field, the interest of the SMPS(Switched Mode Power Supply) is increased. The size and weight of SMPS are decided by inductor, capacitor and transformer. Thus, the low loss converter which is operated in high speed switching is required. The resonant FB DC-DC converter is able to operate in high speed switching and apply to high power field because the switching loss is low. In this thesis, it is proposed to control strategy for constant output power of resonant FB DC-DC converter in variable input voltage. The proposed control system is a digital I-PD type control and apply to phase-shift resonant type controller. The output voltage tracks reference without steady state error in variable input voltage. The validity of proposed control strategy is verified from results of simulation and experiment.

SOI 및 TRENCH 구조를 이용한 저소비 전력형 미세발열체의 설계 (Design of Low Consume Power Ty7e Micro-heaters Using SOl and Trench Structures)

  • 장수;홍석우;이종춘;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.350-353
    • /
    • 1999
  • This Paper Presents the optimized design of micro-heaters using 501(Si-on-insulator) substrate and oxide-filled trench structure In order to justify a lumped model approximation and thermal boundary assumptions, two-dimensional FDM(finite difference among which conduction is the dominant heat dissipation path. Compared with no-trenchs on the SOI structure, the micro-heaters with trench structures has properties of low heater loss and good thermal isolation. The simulation results show that the heater loss decreases as the number. width and distance of trenchs increases.

  • PDF

CoolSiCTM SiC MOSFET Technology, Device and Application

  • Ma, Kwokwai
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.577-595
    • /
    • 2017
  • ${\bullet}$ Silicon Carbide (SiC) had excellent material properties as the base material for next generation of power semiconductor. In developing SiC MOSFET, gate oxide reliability issues had to be first overcome before commercial application. Besides, a high and stable gate-source voltage threshold $V_{GS(th)}$ is also an important parameter for operation robustness. SiC MOSFET with such characteristics can directly use existing high-speed IGBT gate driver IC's. ${\bullet}$ The linear voltage drop characteristics of SiC MOSFET will bring lower conduction loss averaged over full AC cycle compared to similarly rate IGBT. Lower switching loss enable higher switching frequency. Using package with auxiliary source terminal for gate driving will further reduce switching losses. Dynamic characteristics can fully controlled by simple gate resistors. ${\bullet}$ The low switching losses characteristics of SiC MOSFET can substantially reduce power losses in high switching frequency operation. Significant power loss reduction is also possible even at low switching frequency and low switching speed. in T-type 3-level topology, SiC MOSFET solution enable three times higher switching freqeuncy at same efficiency.

  • PDF

식스 스텝 운전을 이용한 선박용 DC 전력 시스템의 직류단 전압 제어 (DC Bus Voltage Regulation With Six-Step Operation in Maritime DC Power System)

  • 윤종훈;손영광;설승기
    • 전력전자학회논문지
    • /
    • 제26권4호
    • /
    • pp.263-270
    • /
    • 2021
  • Active AC/DC converters with PWM operation are utilized to regulate rectified DC bus voltage of a permanent magnet synchronous generator in the maritime DC power system. A DC bus voltage regulation strategy that exploits the six-step operation is proposed in this study. Compared with that of the PWM operation, switching loss of the converter can be significantly reduced under the six-step operation. Moreover, conduction loss can also be reduced due to the high modulation index and reduced flux-weakening current of the six-step operation. A controller is used for the proposed DC bus voltage regulation strategy to verify its validity with the simulation and experimental setup. The simulation and the experimental test results showed that the converter loss reduces to a maximum of 70% and 19%, respectively.

전음성 청각장애인용 골도 전화기 개발 및 성능 평가 (Development of a Bone Conduction Telephone for Conductive Hearing Impaired Persons and its Performance Test)

  • 강경옥;강성훈
    • 한국음향학회지
    • /
    • 제14권2호
    • /
    • pp.113-122
    • /
    • 1995
  • 본 논문에서는 전음성 난청 등의 청각장애인이 외부의 보조기기를 사용하지 않고도 전화통화를 할 수 있도록 개발한 골도 전화기의 특징과 성능 평가결과에 대해 기술한다. 골도청각 뿐만 아니라 기도청각을 이용하여 음성선호를 청취할 수 있도록 설계된 골도 진동자를 개발하여, 청각장애인과 정상인이 골도 전화기를 함께 사용할 수 있다. 또, 청각장애인의 청력특성에 따른 손실을 보상해 줄 수 있는 음색조절 기능이 있으며, 이 기능과 수화음량조절기능을 이용하여 20dB범위의 수화음량정격을 가변할 수 있어 수화음량 증폭기능을 가진 고출력 전화기의 효과도 겸비하고 있다. 19명의 청각장애인을 대상으로 한 명료도 평가 및 요해도 실험 결과에 의하면, 약61dB이내의 골도 청력손실의 청각장애인은 단어나 문장을 이해하여 골도 전화기를 유용하게 사용할 수 있음을 알 수 있었다.

  • PDF

가스히터 보수주기 결정을 위한 히터내부 열전달 매체액 결빙현상 가시화에 관한 연구 (A Study on the Visualization of Ice-formation Phenomena of Bath Water to Decide Maintenance Period of Gas Heater)

  • 이정환;하종만;성원모
    • 한국가스학회지
    • /
    • 제5권3호
    • /
    • pp.1-8
    • /
    • 2001
  • 본 연구는 한국가스공사에서 운영중인 천연가스 공급관리소의 가스히터를 대상으로 겨울철 히터 가동 중단시, 가스히터 내부의 열전달 매체액 (Bath Water)이 빙점에 도달하는 시간을 계산하여 보수주기에 대한 결정 및 동파 취약 부위에 대한 영향을 판단하기 위해 가스히터의 체적을 고려한 비선형 3차원 전산모사를 수행하였다. 이용된 시뮬레이터는 미국 FLUENT사의 FLUENT V 5.0으로서 열유체 유동해석 범용 Code이다. 본 문제는 열전도에 관한 문제로 에너지 방정식을 푸는 방식으로 진행되지만 가스히터의 체적을 고려한 3차원 계산을 수행하기 위해 현장의 가스히터 형상 및 축적을 거의 유사하게 모델링하였고 표면에서 공기에 의한 대류 (Convection)문제와 단열재 사이의 전달 (Conduction)문제, 히터내부 액체의 자연대류 (Natural Convection) 그리고 배관을 통한 열손실의 문제를 고려한 복합적인 열전달 현상을 분석하였다.

  • PDF

진공 증착법으로 제작한 PVDF 박막의 유전 특성과 전기전도도에 대한 연구 (A Study on the Dielectric Properties and Electrical Conduction of PVDF Thin Films by Physical Vapor Deposition)

  • 강성준;이원재;장동훈;윤영섭
    • 대한전자공학회논문지SD
    • /
    • 제37권5호
    • /
    • pp.9-15
    • /
    • 2000
  • 본 논문에서는 진공 증착법 (Physical Vapor Deposition) 과 전계인가를 통해 두께 3㎛ 의 PVDF (polyvinylidene fluoride) 박막을 제작하여 적외선 흡수분석과 유전특성 및 전기전도 현상을 조사하였다. 진공 증착법으로 제작한 PVDF 박막을 적외선 흡수 분광기 (FT-IR) 로 분석한 결과, 509.45 [cm/sup -1/] 와 1273.6 [cm/sup -1/]의 특성피크가 검출되는 것으로 보아 제작된 PVDF 박막이 β형임을 확인할 수 있었다. β형 PVDF 박막의 유전특성을 측정한 결과, 비유전률은 주파수가 증가함에 따라 지속적으로 감소하는 이상분산을 나타내었고 유전손실은 온도의 증가에 따라 200㎐ 에서 7000㎐ 로 유전 흡수점이 이동함을 관찰할수 있었는데, 이는 디바이 이론과 일치하는 것이었다. 유전손실의 온도 의존성으로부터 구한 활성화 에너지(ΔH) 는 21.64㎉/mo1e 로 조사되었다. β형 PVDF 박막의 누설전류밀도에 대한 온도의존성과 전계의존성을 조사하여 PVDF 박막의 전기전도기구가 이온전도임을 확인할 수 있었다.

  • PDF

지능형 헬스케어 욕조시스템 개발을 위한 온수 온도변화 (Change of the Warm Water Temperature for the Development of Smart Healthecare Bathing System)

  • 김기범
    • Korean Chemical Engineering Research
    • /
    • 제44권3호
    • /
    • pp.270-276
    • /
    • 2006
  • 본 연구에서는 전도열손실과 증발에 의한 열손실을 바탕으로 욕조의 자유표면에서 일어나는 온수의 열손실을 해석하고자 한다. 연구결과 욕조의 성능을 평가할 수 있는 식을 열전달 기본식으로 부터 관계식을 도출하였으며 이 식은 매우 시성적이며 정량적이었다. 특히 욕조 내 온수의 냉각은 증발에 의한 열손실이 지배적이었다. 또한, 온수의 온도 냉각 속도는 온수의 온도에는 크게 영향을 받지 않으나 욕실의 습도에 따라 크게 영향을 받는 것으로 확인되었다. 그러므로 욕조의 온도는 $41{\sim}45^{\circ}C$를 유지하며 욕실의 습도가 95%를 유지하는 것이 가장 효과적이라 판단된다.