• 제목/요약/키워드: Conduction cooling

검색결과 217건 처리시간 0.029초

Development and Characterization of a 400-W Slab-type Nd:YAG Gain Module

  • Cha, Yong-Ho;Lee, Sungman;Lim, Gwon;Baik, Sung-Hoon;Kwon, Sung-Ok;Cha, Byung-Heon;Lee, Jung-Hwan;Kang, Eung-Cheol
    • Journal of the Optical Society of Korea
    • /
    • 제16권1호
    • /
    • pp.53-56
    • /
    • 2012
  • We have developed a slab-type Nd:YAG gain module based on the techniques of conduction cooling and end pumping. The Nd:YAG slab is end-capped on both ends by undoped pure YAG and is pumped through the end-caps by stacked arrays of laser diode bars. The slab's surfaces of total internal reflection are in contact on both sides with microchannel cooling blocks which are cooled by water circulation. The power oscillator based on the gain module generates more than 400 W at 1-kW pumping with a slope efficiency of 55%. The small-signal gain of the gain module is 10 in a single zig-zag pass, and the amplified beam shows a near diffraction-limited beam quality.

Nickel/Metal Hydride 전지의 열관리기술 개발 (Thermal Management of a Nickel/Metal Hydride Battery)

  • 김준범
    • 공업화학
    • /
    • 제8권4호
    • /
    • pp.667-672
    • /
    • 1997
  • 고용량 Nickel/Metal hybride 전지의 온도 거동을 3차원 유한요소법 software인 NISA를 사용하여 해석하였다. 전지 내부의 열전도에는 미분형 에너지 수지식을, 외부 대기와의 접촉면은 대류 열전달 방식을 사용하였다. 전지 온도에 영향을 미치는 요소인 열발생량과 대류 열전달계수에 대한 실험을 행하였고, 이 결과로부터 일반식을 도출하였다. 금속 재질의 cooling fin을 사용하므로써 급속한 충전이나 방전시 야기될 수 있는 온도 상승을 상당 부분 방지할 수 있었다. 전지 외벽에 열전도도가 낮고 얇은 절연물질을 부착하여도 최고온도의 상승에 미치는 영향은 미미하였다.

  • PDF

3차원 CFD해석을 이용한 환형 역류형 연소기설계 (DESIGN OF ANNULAR REVERSIBLE COMBUSTOR WITH 3 DIMENSIONAL CFD ANALYSIS)

  • 나상권;심재경;박희호;이성준;전승배
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.247-251
    • /
    • 2010
  • It is very difficult to understand and estimate the heat transfer and flow characteristics in the combustor, which is one of main components in the Auxiliary Power Unit (APU), because its flow filed has very complex structure. In this paper, specified is characteristics of injection and flow through different air goles in the liner, which consist of large circular holes film cooling holes, and tangential air swirl holes. The durability of the liner depends on whether the surface of the liner is exposed to the hot gas over 1000 $^{\circ}C$ of a temperature or net. It is proved that the locations of hot spots estimated from the calculation using CFD are matched well with that from the test. In this study, CFD simulations were performed to examine the heat transfer and temperature distributions in and about a liner wall with film cooling on the wall. This computational study is based on the ensemble average continuity, compressible Navier-Stokes, energy, and PDF combustion equations closed by the standard $k-{\varepsilon}$ turbulence model with standard wall functions for the gas phase and the Fourier equations for conduction in the solid phase.

  • PDF

Temperature dependency of magnetic field drifts of HTS pancake coils for NMR/MRI applications

  • Choi, Kyeongdal;Lee, Seyeon;Kim, Woo-Seok;Lee, Sang Min
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.44-47
    • /
    • 2013
  • We had proposed a winding method so called "Wind-and-Flip", which enables a persistent current operation of an HTS pancake coil without any electrical joint. In order to improve the magnetic field drift characteristics, a prototype HTS coil with the technique was fabricated, and tested under various temperatures. Because the coil doesn't have any electric terminals for current leads, an HTS background magnet was used to induce the persistent current in the coil by field cooling process. A conduction cooling system with a GM cryocooler was prepared to keep the operating temperatures of the prototype coil much below the 77 K. We investigated the magnetic field drift characteristics under the various operating temperatures by measuring the center magnetic field with a cryogenic Hall sensor. The persistent current mode operation at 20 ~ 50K showed a strong possibility of the winding technique for the application such as MRI or NMR.

자동신경 냉각장치를 이용한 흡식반사와 호식반사의 온도특성 측정 (Measurements of Temperature Characteristics of The Lung Inflation and Deflation Reflexes Using Automated Vagal Cooling System in Anesthetized Dogs)

  • 송영진;차은종
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권3호
    • /
    • pp.177-184
    • /
    • 1991
  • Characteristics of the lung inflation and deflation reflexes were measured at various temperatrues on the cervical vagi in five anesthetized mongrel dogs. Nerve temperature was maintained at the body temperature, and $2-14^{\circ}C$ with $2^{\circ}C$ apart using a specially designed automated vagal cooling apparatus with an accuracy to within ${\pm}0.1^{\circ}C$ at each temperature. The inflation reflex was blocked abruptly at $8-10^{\circ}C$. The deflation reflex started weakened at $14^{\circ}C$, thereafter showed a gradual blockade with the temperature decreased with a substantial variance among the animals. It was approximately 75% blocked at $2-6^{\circ}C$. These differences in temperature characteristics made it hard to differentiate the deflation reflex from the inflation reflex. In one animal, however, the inflation reflex was completely blocked with the deflation reflex almost alive at $6-8^{\circ}C$. This suegests that differential cold blockade of the vagal reflexes can be done only in selected subjects. Fur- thermore, the fact that these two reflexes were blocked at different temperatures may be due to the differences in the nerve fiber size and the changes in the conduction velocity with temperature.

  • PDF

CFD전산모사를 이용한 Al 6063 Heat Sink 최적화 설계와 열전도성 Polycarbonate와의 방열성능 비교 분석 (Optimization of Al 6063 Heat Sink using CFD Simulation and Comparative Analysis of Thermal Dissipation Properties with Thermal Conductive Polycarbonate)

  • 허인성;이세일;이아람;유영문
    • 조명전기설비학회논문지
    • /
    • 제28권7호
    • /
    • pp.19-25
    • /
    • 2014
  • In the LED lighting applications, because LED packages are the origin of heat generation, there are thermal design problem on heat sinks. In the thermal design, it is important to consider the total volume and the total weight of heat sink simultaneously. In this study, an Al 6063 heat sink was optimized using Computational Fluid Dynamics(CFD) simulation tool for the cooling of 30W LED module, and then the cooling performance and the total weight of heat sinks with Al 6063 and Thermal Conductive Polycarbonate(TCP) were compared under the same conditions. As the result of simulation, an Al 6063 heat sink was optimized with 22 ea. of fins and 1.6 mm of fin thickness. LED Junction Temperature of the TCP Heat Sink was $5.6^{\circ}C$ higher, but total weight of it was 47 % less than the Al 6063.

최적화 기법과 분산 컴퓨팅을 이용한 재료 성형공정의 역문제에 관한 연구 (A Study on Inverse Problem of Materials Forming Process using Optimization Technique and Distributed Computing)

  • 최주호;오동길;하덕식;김준범
    • 대한기계학회논문집A
    • /
    • 제28권5호
    • /
    • pp.632-639
    • /
    • 2004
  • In this paper, an inverse problem of glass forming process is studied to determine a number of unknown heat transfer coefficients which are imposed as boundary conditions. An analysis program for transient heat conduction of axi-symmetric dimension is developed to simulate the forming and cooling process. The analysis is repeated until it attains periodic state, which requires at least 30 cycles of iteration. Measurements are made for the temperatures at several available time and positions of glass and moulds in operation. Heat removal by the cooling water from the plunger is also recorded. An optimization problem is formulated to determine heat transfer coefficients which minimize the difference between the measured data and analysis results. Significant time savings are achieved in finite difference based sensitivity computation during the optimization by employing distributed computing technique. The analysis results by the optimum heat transfer coefficients are found to agree well with the measured data.

The latest trend in magnetocardiogram measurement system technology

  • Lee, Y.H.;Kwon, H.;Kim, J.M.;Yu, K.K.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제22권4호
    • /
    • pp.1-5
    • /
    • 2020
  • Heart consists of myocardium cells and the electrophysiological activity of the cells generate magnetic fields. By measuring this magnetic field, magnetocardiogram (MCG), functional diagnosis of the heart diseases is possible. Since the strength of the MCG signals is weak, typically in the range of 1-10 pT, we need sensitive magnetic sensors. Conventionally, superconducting quantum interference devices (SQUID)s were used for the detection of MCG signals due to its superior sensitivity to other magnetic sensors. However, drawback of the SQUID is the need for regular refill of a cryogenic liquid, typically liquid helium for cooling low-temperature SQUIDs. Efforts to eliminate the need for the refill in the SQUID system have been done by using cryocooler-based conduction cooling or use of non-cryogenic sensors, or room-temperature sensors. Each sensor has advantage and disadvantage, in terms of magnetic field sensitivity and complexity of the system, and we review the recent trend of MCG technology.

$CO_{2}$이용 열펌프의 실외열교환기 성능에 관한 실험적 연구 (An Experimental Study on the Performance of Outdoor Heat Exchanger for Heat Pump Using $CO_{2}$)

  • 장영수;이민규;안영산;김영일
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.101-109
    • /
    • 2005
  • The purpose of this study is to investigate the performance of outdoor heat exchanger for heat pump using carbon dioxide. Two types of fin and tube heat exchangers (2 rows for type A and 3 rows for B) are tested. Both heat exchangers have counter-cross flow and 1-circuit arrangement. Test results such as heat transfer rate, pressure drop characteristics and temperature distribution in the heat exchanger are shown with respect to mass flow rate of refrigerant and frontal air velocity For cooling mode, the minimum temperature difference between air and refrigerant of type B is smaller than that of type A by $1^{circ}C$, but the pressure loss of air side is much higher for type B by $29\%$. It is found that a large temperature gradient of carbon dioxide during gas cooling Process Promotes thermal conduction through tube wall and fins which results in degradation of heat transfer performance. For heating mode operation, type B heat exchanger shows higher heat transfer performance compared to type A. However, because pressure loss of refrigerant side of type B is much greater than that of type A, the refrigerant outlet pressure of type B becomes lower than that of type A.

유한요소법을 이용한 탄소강의 경화능 해석(I) (Analysis of Hardenability for Carbon Steel using Finite Element Method (I))

  • 김옥삼;구본권
    • 열처리공학회지
    • /
    • 제11권2호
    • /
    • pp.131-139
    • /
    • 1998
  • The object of this research is to estimate the hardenability of quenched carbon steels AISI 1050. The equation of transient heat conduction was analyzed to derive cooling curve by finite element method. The effects of temperature on physical properties, metallic structures and the latent heat by phase transformation were considered. A good agreement was found between analytical and experimental results to show that the proposed numerical procedure was reliable. This procedure could be used as the detabase for optimal condition of heat treatment cycle.

  • PDF