• Title/Summary/Keyword: Conducted Noise

Search Result 1,598, Processing Time 0.053 seconds

The Flow Analysis for Vibration and Noise Diagnostic of Vacuum Cleaner Fan Motor (진공청소기 팬 모터의 진동 및 소음원인 분석을 위한 유동해석)

  • 김재열;곽이구;안재신;양동조;송경석;박기형
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.4
    • /
    • pp.56-63
    • /
    • 2004
  • Recently technology resulted in highly efficient and multiple-functional electric appliances considering environmental problems. One of the environmental problems is noise of a product in respect to its function. A vacuum cleaner is an essential electric appliance in our daily lives. However, severe noise resulted from high motor speed for improving the function of the appliance is a nuisance for the user. This noise is caused by vibration from various parts of the appliance and fluid noise during a series of intake and exhaust processes while rotating the impeller connected to the axle at a high speed of the fan motor inside the vacuum cleaner rotating around 30,000-35,000rpm. Despite the fact that many researchers conducted studies on reducing the noise level of the fan motor in a vacuum cleaner, only few studies have been conducted considering both the theoretical and experimental aspects using fluid analysis by measuring vibration and noise. Moreover, there has not been a study that accurately compared major noise data obtained considering both of the aspects. In this study, both aspects were considered by considering the following experimental and theoretical methods to verify the major causes of noise from the fan motor in a vacuum cleaner.

Study on Health Impact Assessment Plan of Traffic Noise (교통소음의 건강영향 평가방안에 관한 연구)

  • Sun, Hyo-Sung;Park, Young-Min
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.774-776
    • /
    • 2007
  • Because many people suffer physical and mental damage from the noise of the traffic facilities including road, rail, airport, the advanced countries have conducted the researches of predicting and solving the impact of the human health exposed to traffic noise. Therefore, this study suggests the fundamental plans which can assess the health impact of traffic noise on the basis of the prediction results about the health impact of traffic noise.

  • PDF

The Analysis of Vibration characteristics for Vacuum Cleaner Fan Motor Using 3-D Laser Vibrator (3차원 레이저 진동 측정기를 이용한 초고속 진공청소기 모터의 진동특성분석)

  • 김재열;김우진;심재기;김영석
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.399-405
    • /
    • 2004
  • Recently technology resulted in highly efficient and multiple-functional electric appliances considering environmental problems. One of the environmental problems is noise of a product in respect to its function. A vacuum cleaner is an essential electric appliance in our daily lives. However, severe noise resulted from high motor speed for improving the function of the appliance is a nuisance for the user. This noise is caused by vibration from various parts of the appliance and fluid noise during a series of intake and exhaust processes while rotating the impeller connected to the axle at a high speed of the fan motor inside the vacuum cleaner rotating around 30,000-35,000 rpm. Despite the fact that many researchers conducted studies on reducing the noise level of the fan motor in a vacuum cleaner, only few studies have been conducted considering both the theoretical and experimental aspects using fluid analysis by measuring vibration and noise. Moreover, there has not been a study that accurately compared major noise data obtained considering both of the aspects. In this study, both aspects were considered by considering the following experimental and theoretical methods to verify the major causes of noise from the fan motor in a vacuum cleaner.

  • PDF

Interior Noise Reduction for Subway Railroad Vehicles (통근형 지하철의 실내소음저감)

  • 김종년;유동호;박경환
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.265-272
    • /
    • 1998
  • In this paper, the intoner noise reduction for subway railroad vehicles was studied by improving transmission loss of carbody panels and side doors, and on-line tests were conducted to examine the exterior noise levels at various running conditions. Also the transmission loss for design candidates of the carbody specimen was measured in two reverberation rooms. From the results of the tests, side door gap is the most dominant factor affecting the Interior noise level of subway railroad cars with a sliding typed side door. The next one is revealed to transmission loss of a floor panel. To improve the transmission loss of the carbody, many activities were conducted such as, treatment of resilient and sound-absorbing materials and reducing the gap of the side door by adopting a brush and rubber, etc. The estimated interior noise level for modified car which is designed with improved carbody panels is lower than original car by about 5㏈.

  • PDF

Criteria for multiple noises in residential buildings uslng combined rating system (공동주택 생활소음의 통합 평가등급 설정)

  • Ryu, Jong-Kwan;Lee, Pyoung-Jik;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.367-371
    • /
    • 2005
  • Social noise survey on multiple residential noises such as nut impact, air-borne, bathroom, drainage and traffic noises was conducted to investigate major variables affecting the overall satisfaction for noise environment The effect of individual noise perception on the evaluation of the overall noise environment was investigated through a questionnaire survey on annoyance, disturbance and noise sensitivity. Auditory experiments was also undertaken to determine noise level according to the percent of satisfaction for individual noise source. As a result of survey, it was found that satisfaction for floor impact noise most greatly affects the overall satisfaction for noise environment and annoyance most greatly affects the satisfaction for individual noise sources. Result of auditory experiment showed that the noise level of floor impact noise by bang machine, airborne, drainage and traffic noise corresponding to 50% satisfaction is 44dB($L_{i,Fmax,AW}$) and 40dBA, respectively.

  • PDF

Radiated Noise Analysis of Marine Diesel Engine from Structural Vibration (선박용 디젤 엔진의 구조진동에 의한 방사소음 해석)

  • Kim, Dae-Hwan;Hong, Chin-Suk;Jeong, Weui-Bong;Park, Jeong-Geun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1060-1065
    • /
    • 2007
  • This paper summarizes a design procedure of radiated noise from engine blocks of marine engines. This air-borne noise is one of the significant noise contributors including the aeroacoustic noise due to intake and exhaust and the re-radiation due to structure-borne noise. Excitation forces by engine operations are evaluated taking into account the power generation mechanism from the burning process to the subsequence motion of internal parts; piston, connecting rod, and crank shaft. The acoustic transfer vector method is incorporated to effectively simulate the radiated noise field under the various operation conditions. A contribution analysis for the various excitations to the radiated noise is conducted. It is found that the firing pressure is the main source of the radiated noise, and so the structure of the cylinder can be modified to significantly reduce the radiated noise from the engine block.

  • PDF

Investigation of the noise sources for the centrifugal fan and aeroacoustic noise prediction (진공청소기 원심 홴의 소음원 분석 및 공력 소음 예측)

  • Jeong, Ye-Eun;Bae, Young-Min;Moon, Young-J.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.645-645
    • /
    • 2009
  • In many practical applications of the centrifugal fan, the impeller-diffuser interaction noise is considered as a main source of fan noise. The housing for an electric motor is also expected to play an important role on noise propagation because of its complicated configuration. This study investigates the impeller-diffuser interaction noise and its sources by computing three-dimensional, incompressible flow field of the centrifugal fan in motor housing. The effect of motor case on fan noise characteristic is then investigated using the Brinkman penalization method, while the noise source associated with impeller-diffuser interaction is mathematically modeled. It is found that the present methodology combined with mathematical description of noise source provides a fairly good agreement with the experimental results, indicating that the motor housing has significant effect on noise characteristics. Finally, aeroacoustic noise prediction for various impeller-diffuser blade count ratios is conducted for noise reduction.

  • PDF

Effect of Type and S/N Ratio of Combined Noise Sources on Sleep Disturbance (수면방해에 대한 복합소음의 종류와 S/N비의 영향)

  • Lee, Pyoung-Jik;Shim, Myoung-Hee;Jeon, Jin-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.9
    • /
    • pp.960-966
    • /
    • 2009
  • The World Health Organization(WHO) has reported the sleep disturbance as one of the adverse effects of noise. And the effect of combined noise sources on human have been investigated because community noises are seldom heard and are concurrent. Therefore, the effects of combined noise source and its S/N ratio on sleep disturbance were investigated; as a single noise source, road traffic noise was selected, and construction and movie noise were combined with road traffic noise. Tests for sleep disturbance were conducted in bedrooms and the effect on each subjects' sleep was evaluated by questionnaire. The results showed that the rate of awakening increased slightly only when the SPL of construction noise was 10 dB higher than that of road traffic noise. It was also found that the sleep disturbance was affected by the type of combined noise sources and its S/N ratio.

Dose-response relationship for annoyance caused by combined noise sources in urban spaces (외부 공간에서 복합소음에 대한 불쾌감 연구)

  • Lee, Pyoung-Jik;You, Jin;Jeong, Choong-Il;Yeon, Jun-Oh;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.264-267
    • /
    • 2008
  • Relationship between exposure to combined noise sources and community annoyance have been investigated. Social surveys were conducted in urban spaces near the construction site with road traffics. The question relating to noise annoyance was answered on an 11-point numerical scale and 5-point verbal scale according to ISO 15666. The questionnaire also contained demographic factors, interference with daily activities, health-related symptoms, and noise sensitivity. Noise levels were measured in terms of A-weighted equivalent level ($L_{Aeq}$), and noise mapping technique was applied to predict the noise levels of urban spaces. Synthesis curves for the relationship between noise levels and percentage highly annoyed for combined noise sources were derived, and compared to the curves from a single noise source.

  • PDF

Classification of Noise Insulation Performance in Apartment Buildings through Noise survey and Auditory Experiment (설문조사와 청감실험을 통한 공동주택 차음성능의 평가등급 설정)

  • Ryu, Jong-Kwan;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.666-669
    • /
    • 2005
  • Social noise survey and auditory experiment on residential noises such as floor impact, air-borne, bathroom, drainage and traffic noises were conducted to classily a noise insulation Performance in apartment building. The survey results showed that annoyance among subjective responses to residential noises was most greatly affecting to satisfaction with noises. In the survey, boundary limit between satisfaction and dissatisfaction was also determined. Auditory experiments was also undertaken to determine noise insulation performance according to the percent of satisfaction for individual noise source. Result of auditory experiment showed that the noise insulation performance for floor impact, airborne, drainage and traffic noise corresponding to 40 % satisfaction is 49 dB (L$_{i,Fmax,AW}$), 48 dB (R'w), N-41, and N-40, respectively. Finally, classes of noise insulation performance in apartment building were proposed according to satisfaction with noises

  • PDF