• Title/Summary/Keyword: Conductance meter

Search Result 13, Processing Time 0.029 seconds

Real-time measurement of void fraction and its propagation speed of slug flow with two Conductance meters (두 개의 컨덕턴스미터를 이용한 슬러그류의 기공률 및 기공률 전달속력 실시간 측정)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kang, Deok-Hong;Kim, Moo-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1569-1573
    • /
    • 2004
  • Two ring-type conductance meters were manufactured to measure void fraction and its propagation speed in slug flow. The signal of conductance meter with two rings depends on liquid temperature. Therefore a conductance meter with separated probe designed by Coney (1973), which is independent of liquid temperature, was used and experimentally proved. The manufactured conductance meters showed a good repeatability and agreement with the analytical solution by Coney (1973). From time lag between two conductance meter, we could calculate the propagation speed of void fraction.

  • PDF

Development of a Real-Time Soil Moisture Meter using Oscillation Frequency Shift Method

  • Kim, Ki-Bok;Lee, Nam-Ho;Lee, Jong-Whan;Lee, Seoung-Seok;Noh, Sang-Ha
    • Agricultural and Biosystems Engineering
    • /
    • v.2 no.2
    • /
    • pp.63-68
    • /
    • 2001
  • The objective of this study was to develop a real-time soil moisture meter using RF impedance. The impedance suchas capacitance and resistance (or conductance) was analyzed using parallel cylinder type capacitance probe(C-probe) and Q-meter (HP4342). The capacitance and conductance of soil increased as volumetric water content increased. The 5 MHz of modified Colpitts type crystal oscillator was designed to detect the capacitance change of the C-probe with moist soil. A third order polynomial regression model was proposed to describe the relationship between RF impedance and volumetric water content. The prototype real time moisture meter consisted of the C-probe, sample container, oscillator, frequency counter and related signal processing units. The calibration equation for measurement of volumetric moisture content of soil was developed and validated. The correlation coefficient and root mean square error between measured volumetric water content by oven method and predicted values by prototype moisture meter for unknown soil samples were 0.984 and 0.032$cm^3$$cm\^3$, respectively.

  • PDF

Double Layer (Wet/CVD $SiO_2$)의 Interface Trap Density에 대한 연구

  • Lee, Gyeong-Su;Choe, Seong-Ho;Choe, Byeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.340-340
    • /
    • 2012
  • 최근 MOS 소자들이 게이트 산화막을 Mono-layer가 아닌 Multi-Layer을 사용하는 추세이다. Bulk와 High-k물질간의 Dangling Bond를 줄이기 위해 Passivation 층을 만드는 것을 예로 들 수 있다. 이러한 Double Layer의 쓰임이 많아지면서 계면에서의 Interface State Density의 영향도 커지게 되면서 이를 측정하는 방법에 대한 연구가 활발히 진행되고 있다. 본 연구에서는 $SiO_2$ Double Layer의 Interface State Density를 Conductance Method를 사용하여 구하는 연구를 진행하였다. Wet Oxidation과 Chemical Vapor Deposition (CVD) 공정을 이용하여 $SiO_2$ Double-layer로 증착한 후 Aluminium을 전극으로 하는 MOS-Cap 구조를 만들었다. 마지막 공정은 $450^{\circ}C$에서 30분 동안 Forming-Gas Annealing (FGA) 공정을 진행하였다. LCR meter를 이용하여 high frequency C-V를 측정한 후 North Carolina State University California Virtual Campus (NCSU CVC) 프로그램을 이용하여 Flatband Voltage를 구한 후에 Conductance Method를 측정하여 Dit를 측정하였다. 본 연구 결과 Double layer (Wet/CVD $SiO_2$)에 대해서 Conductance Method를 방법을 이용하여 Dit를 측정하는 것이 유효하다는 것을 확인 할 수 있었다. 본 실험은 앞으로 많이 쓰이고 측정될 Double layer (Wet/CVD $SiO_2$)에 대한 Interface State Density의 측정과 분석에 대한 방향을 제시하는데 도움이 될 것이라 판단된다.

  • PDF

Design and Building of Flow-rate Measurement Apparatus for Compressible Fluid (압축성유체 유량계측장치 설계 및 제작)

  • Ji, S.W.;Jang, J.S.
    • Journal of Drive and Control
    • /
    • v.10 no.4
    • /
    • pp.29-33
    • /
    • 2013
  • Pneumatic system is widely applied in various industry because it have a many advantage(low cost, high safety, etc..). For design of pneumatic system, accurate flow measurement is required. In this study, compressible fluid flow measurement apparatus was designed and built. It uses an isothermal chamber that can approximate isothermal condition. Therefore, it can be measured for flow-rate using pressure response of isothermal chamber. As a result, this apparatus can be measured for sonic conductance and critical pressure ratio of pneumatic components and it required less time and energy than conventional flow meter. The effectiveness of the designed apparatus is proved by experimental result.

Experimental Approach to Equalizing the Orifice Method with the Throughput One for the Measurement of TMP Pumping Speed

  • Lim, J.Y.;Kang, S.B.;Shin, J.H.;Koh, D.Y.;Cheung, W.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.18-18
    • /
    • 2010
  • Methods of the characteristics evaluation of turbo-molecular pumps (TMP) are well-defined in the international measurement standards such as ISO, PNEUROP, DIN, JIS, and AVS. The Vacuum Center in the Korea Research Institute of Standards and Science has recently designed, constructed, and established the integrated characteristics evaluation system of TMPs based on the international documents by continuously pursuing and acquiring the reliable international credibility through measurement perfection. The measurement of TMP pumping speed is normally performed with the throughput and orifice methods dependent on the mass flow regions. However, in the UHV range of the molecular flow region, the high uncertainties of the gauges, mass flow rates, and conductance are too critical to precisely accumulate reliable data. With UHV gauges of uncertainties less than 15% and a calculated conductance of the orifice, about 35% of pumping speed uncertainties are experimentally derived in the pressure range of less than $10^{-6}$ mbar. In order to solve the uncertainty problems of pumping speeds in the UHV range, we introduced an SRG with 1% accuracy and a constant volume flow meter (CVFM) to measure the finite mass flow rates down to $10^{-3}$ mbar-L/s with 3% uncertainty for the throughput method. In this way we have performed the measurement of pumping speed down to less than $10^{-6}$ mbar with an uncertainty of 6% for a 1000 L/s TMP. In this article we suggest that the CVFM has an ability to measure the conductance of the orifice experimentally with flowing the known mass through the orifice chambers, so that we may overcome the discontinuity problem encountering during introducing two measurement methods in one pumping speed evaluation sequence.

  • PDF

Comparison of NERICA and Asian rice among traits relevant to drought resistance in the field and the effects of compost

  • Fujii, Michihiko
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.335-335
    • /
    • 2017
  • Recently NERICA (New Rice for Africa) was developed by a crossing of African rice (Oryza glaberrima Steud.) and Asian rice (Oryza sativa L.) in West Africa, and is considered to be drought resistant, but drought resistance of NERICA and differences between Asian rice are not clarified enough. In this research, NERICA (four cultivars and two lines), Asian rice (three cultivars and sativa parent of NERICA) and African rice (glaberrima parent of NERICA) were cultivated in the field in Shizuoka University under drought and traits of each cultivar and line relevant to drought resistance, stomatal conductance by porometer, soil water content of individual depths by TDR method, SPAD values by SPAD meter and leaf thickness by micrometer, were measured and compared with dry matter production and yield. Effects of compost were also compared among sativa parent, one NERICA cultivar and two NERICA lines. Glaberrima parent showed highest top dry weight. One NERICA line, one drought resistant Asian rice cultivar and sativa parent, showed higher top dry weight and yield (ear weight) than other Asian rice cultivars and NERICA cultivars and line tested. Compost tended to increase top dry weight and yield in one of NERICA line and sativa parent. But in one NERICA cultivar and line, top dry weight and yield were not increased. In one of Asian rice, one of NERICA line and sativa parent that showed high top dry weight and yield, stomatal conductance was high. On the contrary the glaberrima parent and in other NERICA cultivars and line it was low. In sativa parent compost increased stomatal conductance but in NERICA cultivar and lines it was not. Among cultivars and lines that showed high top dry weight and yield sativa parent and one of NERICA line SPAD value and leaf thickness were high but in one of Asian rice and glaberrima parent they were low. Cultivar and line differences in yield and top dry weight among Asian rice and NERICA were significantly correlated with those in stomatal conductance ($r=0.778^{**}$ and $r=0.654^*$, respectively) and those in leaf thickness ($r=0.600^*$ and $r=0.640^*$, respectively). In Asian rice cultivars average soil water content was significantly correlated with yield ($r=0.886^*$) but in NERICA cultivars and lines it was not significant correlated (r= -0.256). Cultivar and line differences in leaf thickness were significantly correlated with SPAD value ($r=0.773^{**}$). In Asian rice cultivars it was significantly correlated ($r=0.962^{**}$), but in NERICA cultivars and lines it was not significantly correlated (r=0.559). Asian rice cultivars tended to consume soil water to increase yield but in NERICA cultivars and lines the tendency was not clear. Correlation between SPAD value and leaf thickness was different between Asian rice and NERICA cultivars and lines, and in Asian rice cultivars it was significantly correlated but in NERICA cultivars and lines it was not significant. Importance of maintaining high stomatal conductance by high leaf thickness was clarified.

  • PDF

Study on the Measurement of TMP Pumping Speed (터보분자펌프(TMP) 배기속도 측정에 관한 고찰)

  • Kang, S.B.;Shin, J.H.;Cha, D.J.;Koh, D.Y.;Cheung, W.S.;Lim, J.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.4
    • /
    • pp.249-255
    • /
    • 2010
  • Methods of the characteristics evaluation of turbo-molecular pumps (TMP) are well-defined in the international measurement standards such as ISO, PNEUROP, DIN, JIS, and AVS. The Vacuum Center in the Korea Research Institute of Standards and Science (KRISS) has recently designed, constructed, and established the integrated characteristics evaluation system of TMPs based on the international documents by continuously pursuing and acquiring the reliable international credibility through measurement perfection. The measurement of TMP pumping speed is normally performed with the throughput and orifice methods dependent on the mass flow regions. However, in the UHV range of the molecular flow region, the high uncertainties of the gauges, mass flow rates, and conductance are too critical to precisely accumulate reliable data. In order to solve the uncertainty problems of pumping speeds in the UHV range, we introduced a SRG with 1% accuracy and a constant volume flow meter (CVFM) to measure the finite mass flow rates down to $10^{-1}$ Pa-L/s with 3% uncertainty for the throughput method. In this way we have performed the measurement of pumping speed down to $10^{-4}$ Pa with an uncertainty of less than 6% for a 1000 L/s TMP. In this article we suggest that the CVFM has an ability to measure the conductance of the orifice experimentally with flowing the known mass through the orifice chambers, so that we may overcome the discontinuity problem encountering during introducing two measurement methods in one pumping speed evaluation sequence.

A Study on the Characteristics of $TiO_2$ Thin Films by Sol-Gel Process (졸-겔법에 의한 $TiO_2$ 박막의 특성에 관한 연구)

  • 황규석;김병훈
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.3
    • /
    • pp.281-288
    • /
    • 1995
  • to prepare the TiO2 thin films, acetyl-acetone(2.4-pentanedione)(1 : 1 molar ratio) was dissolved in the propanol solution of titanium(IV)isopropoxide(Ti[OCH(CH3)2]4). Al, Cr and Sb in the form of soluble salt and niobium ethoxide were added s dopants, respectively. Thin films were coated by the dip-coating method and characteristics were investigated by XRD, SEM and conductance meter. As a result, viscosity of sol was maintained below 4 centi Poise more than 20 days, and crystal growth and diminution of resistivity occurred as the heat treatment temperature increased. The grains grew over 1${\mu}{\textrm}{m}$ and the lowest resistivity was obtained when Nb was added at 130$0^{\circ}C$.

  • PDF

Measurement of Soil Moisture Content Using RF Impedance in the Range of 1 to 30MHz (고주파 임피던스를 이용한 토양수분함량 측정에 관한 연구)

  • Kim, Ki-Bok;Lee, Nam-Ho;Noh, Sang-Ha
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.40 no.6
    • /
    • pp.79-88
    • /
    • 1998
  • This study was conducted to measure the moisture content of soil using RF impedance in the range of 1 to 30MHz. Considering the water potential flow in the soils, two types of sensor such as parallel cylinder and perpendicular plate type were fabricated and tested. The capacitance and resistance of sonsors for soil samples having moisture content range of 2 to 27% were measured by Q-meter (HP4342). The higher soil moisture content was and the larger soil bulk density was, the more the capacitance of sensors increased. To eliminate the effect of bulk density on measuring soil moisture content using RF impedance, two kinds of model having the density independent functions such as the ratio of capacitance change to conductance change and weight of water and dry soils respectively were developed and estimated by regression analysis.

  • PDF

Measurements of Streambed Hydraulic Conductivity Using Drive-point Piezometers and Seepage Meters in the Upper Reaches of Anseong Stream (관입형 피조미터와 시피지미터를 이용한 안성천 상류구간 하상 수리전도도 측정)

  • Lee, Jeongwoo;Chun, Seon Geum;Yi, Myeong Jae;Kim, Nam Won;Chung, Il-Moon;Lee, Min Ho
    • The Journal of Engineering Geology
    • /
    • v.25 no.3
    • /
    • pp.413-420
    • /
    • 2015
  • Streambed hydraulic conductivity along the upper reaches of the Gongdo stage of Anseong Stream was estimated through measurements of stream-aquifer exchange rates (using a seepage meter) and vertical hydraulic gradients (using a manually driven piezometer). From the measured data, it was found out that the stream-aquifer exchange rates varied from -1.55 × 10-6 to 1.77 × 10-5 m/s, the corresponding vertical hydraulic gradient varied from -0.122 to 0.030, and the values of the streambed vertical hydraulic conductivity were estimated from 1.77 × 10-5 to 1.97 × 10-3 m/s, with variations representing local differences. The results are within the general range of streambed hydraulic conductivity values suggested by Calver (2001) and are slightly higher than values previously measured at other stream sites in Korea. The combined use of a drive-point piezometer and seepage meter (both constructed of high-strength stainless steel) is expected to be of practical use in the estimation of streambed hydraulic conductance, given the durability and portability of the instruments.