• Title/Summary/Keyword: Conditions for Recovery

Search Result 1,302, Processing Time 0.036 seconds

The Effect of Foot Cooling on Body Temperature (발바닥 부위 쿨링이 심부 체온에 미치는 효과)

  • Park, Yujin;Kim, Junghun;Park, Jieun;Kim, Jiin;Lee, Jongmin
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.232-236
    • /
    • 2017
  • In this study, We investigated the effect of foot cooling on the reduction of body temperature after hard exercise at the high temperature of $40^{\circ}C$. We performed a total of 30 subjects, and the subjects performed treadmill exercise for 30 minutes. We produced the cooling device to cool the foot using Peltier module. After the end of the exercise, We performed normal recovery method and cooling recovery method(one foot, both feet) for 1 hour on the same indoor environmental conditions and confirmed the change of body temperature of subjects. The results of deep body temperature measurement showed average $38.78{\pm}0.22^{\circ}C$ to $38.54{\pm}0.15^{\circ}C$ when the normal recovery method was performed. Cooling recovery method on one foot showed average $38.69{\pm}0.14^{\circ}C$ to average $38.06{\pm}0.17^{\circ}C$ and Cooling recovery method on both feet showed average $38.69{\pm}0.15^{\circ}C$ to average $37.84{\pm}0.21^{\circ}C$. There was a significant difference between the normal recovery method and the one foot cooling recovery method(p < .05), there was a significant difference between the normal recovery method and the both feet cooling recovery method(p < .05) and there was a significant difference between the one foot cooling recovery method and the both feet cooling recovery method(p < .05). Body temperature showed the lowest decrease rate when the normal recovery method was performed, and body temperature showed the highest decrease rate when the both feet cooling recovery method was performed. Therefore, recovery of cooling on the foot after hard exercise have decreased body temperature, delay fatigue in the body, and will be contributed to improvement of athlete performance.

The Performance of a Simultaneous Heat and Cooling Heat Pump at Various Charging Conditions (동시냉난방 히트펌프의 냉매 충전량과 운전모드 변화에 따른 성능특성에 관한 연구)

  • Song, In-Sik;Choi, Jong-Min;Joo, Young-Ju;Chung, Hyun-Joon;Kang, Hoon;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.7
    • /
    • pp.492-499
    • /
    • 2008
  • The cooling load in winter is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the performance of a multi-heat pump with 3-piping system was investigated as a function of refrigerant charge and its performance was analyzed in cooling mode, heating mode, and heat recovery mode. COP in the heating or cooling mode showed little dependence on refrigerant charge at overcharge conditions, while those were strongly dependent on refrigerant charge at undercharge conditions and outdoor inlet temperature. In the heat recovery mode, the performance of the system was very sensitive to charge amount at all conditions. Optimum charge amount in the heat recovery mode was 14% lower than that in the cooling mode at the standard condition because the refrigerant only passed the indoor units. It is required to store the excessive refrigerant charge in a storage tank to optimize the system performance at operating modes.

Optimization of Extraction of Fpase from the Fermented Bran of Aspergillus niger in Solid State Fermentation

  • Chandra, M. Subhosh;Reddy, B. Rajasekhar;Choi, Yong-Lark
    • Journal of Applied Biological Chemistry
    • /
    • v.51 no.4
    • /
    • pp.155-159
    • /
    • 2008
  • A local isolate of Aspergillus niger was cultivated under optimal growth conditions on wheat bran in solid state fermentation. Filter paperase from fermented bran was separately extracted with different solvents to test the recovery of the enzyme. Among solvents tested, distilled water served as the best leachate, thus the conditions were further optimized with distilled water. After two washes of fermented bran with distilled water for 1.5 h each under stationary conditions at 1 g wheat bran: 5 mL distilled water, the maximum recovery of 13.5 $Ug^{-1}$ of wheat bran was obtained.

A Study on the Performance of Paper Heat Exchanger for Exhaust Heat Recovery (배기열 회수용 종이 열교환기의 성능에 관한 연구)

  • Yoo, Seong-Yeon;Chung, Min-Ho;Choi, Jae-Ho;Kwon, Hwa-Kil;Lee, Chun-Woo;Lee, Ki-Seong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.245-250
    • /
    • 2003
  • In order to control indoor air quality and save energy, it is needed to install a suitable ventilation system equipped with heat exchanger for heat recovery. The purpose of this research is to find the performance of paper heat exchanger for exhaust heat recovery, which exchanges latent heat as well as sensible heat. Experimental apparatus comprises heat exchanger model, constant temperature and humidity chamber, fan and measurement systems for temperature, pressure and flow rate. Thermal performance and pressure loss of the paper heat exchanger are measured and compared at various air velocities and outdoor conditions. Experimental results show that paper heat exchanger can recover $50{\sim}70%$ of the enthalpy difference between supply and exhaust air.

  • PDF

Studies on the Recovery of Useful Materials from Disposable Diaper Waste using Pilot Stock Preparation Units (파일럿 지료 조성설비를 이용한 폐 일회용 기저귀의 유용성분 회수에 관한 연구)

  • Lee, Tai Ju;Nam, Yoon Seok;Park, Jeong Eun;Jo, Jun Hyung;Ryu, Jeong Yong;Lee, Ho Sun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.47 no.4
    • /
    • pp.66-75
    • /
    • 2015
  • Disposable diaper waste is consisted of plastic, fiber, and SAP (Super Absorbent Polymer). They are valuable to be used as raw materials of other products including plastic blocks and pulp mold. Nevertheless, disposable diaper waste have been disposed by landfill and incineration without recycling. Due to strict environmental regulations it is necessary to develop fractionation technique to recycle the disposable diaper waste. In this study the fractionation technique using pilot-scale stock preparation units was investigated. Process for separation of plastic and fibers from disposable diaper waste was composed by the combination of pilot-scale pulper, drum screen, screen and cleaner. Recovery rate of plastics and fiber was checked according to the various operating conditions. In drum screen, recovery rate of plastic was high when the cut size of disposable diaper waste was $5cm{\times}5cm$. The highest recovery rate of fiber was achieved with 0.3 mm slot screen. It is important to control the neutral state of SAP for improvement of recovery rate of fiber since SAP can be swelled easily in water. Therefore SAP can be controlled efficiently by the addition of calcium chloride into the pulper. Consequently recovery rates of plastics and fibers were over 90 and 80% under the optimum pilot operating conditions.

Early Phase Contingency Trajectory Design for the Failure of the First Lunar Orbit Insertion Maneuver: Direct Recovery Options

  • Song, Young-Joo;Bae, Jonghee;Kim, Young-Rok;Kim, Bang-Yeop
    • Journal of Astronomy and Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.331-342
    • /
    • 2017
  • To ensure the successful launch of the Korea pathfinder lunar orbiter (KPLO) mission, the Korea Aerospace Research Institute (KARI) is now performing extensive trajectory design and analysis studies. From the trajectory design perspective, it is crucial to prepare contingency trajectory options for the failure of the first lunar brake or the failure of the first lunar orbit insertion (LOI) maneuver. As part of the early phase trajectory design and analysis activities, the required time of flight (TOF) and associated delta-V magnitudes for each recovery maneuver (RM) to recover the KPLO mission trajectory are analyzed. There are two typical trajectory recovery options, direct recovery and low energy recovery. The current work is focused on the direct recovery option. Results indicate that a quicker execution of the first RM after the failure of the first LOI plays a significant role in saving the magnitudes of the RMs. Under the conditions of the extremely tight delta-V budget that is currently allocated for the KPLO mission, it is found that the recovery of the KPLO without altering the originally planned mission orbit (a 100 km circular orbit) cannot be achieved via direct recovery options. However, feasible recovery options are suggested within the boundaries of the currently planned delta-V budget. By changing the shape and orientation of the recovered final mission orbit, it is expected that the KPLO mission may partially pursue its scientific mission after successful recovery, though it will be limited.

Study on the Apply Characteristics to the Gasoline Engine of Exhaust Heat Recovery Device Counterflow (대향류식 배기열 회수장치의 가솔린기관 적용 특성에 관한 연구)

  • Shin, Suk-Jae;Kim, Jong-Il;Jung, Young-Chul;Choi, Doo Seuk
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.4
    • /
    • pp.153-158
    • /
    • 2013
  • The purpose of this study is to investigate the performance characteristics of the counterflow exhaust heat recovery device for the applied gasoline engines. The EHRS device is installed behind the catalyst. This study investigates the engine warm-up characteristic, the exhaust noise characteristic, the back-pressure characteristic. The engine warm-up characteristics is (load 0%, load 10%, load 20%) in (idle, 1000rpm, 1500rpm, 2000rpm, 2500rpm) conditions by measuring the time it warmed up, coolant temperature ($25^{\circ}C{\sim}80^{\circ}C$) until the performance evaluation is performed. The wide open throttle and the coast down the exhaust noise and the back-pressure characteristic experiment repeated twice. The test conditions is 950rpm~6,050rpm proceed experiment repeated 3-5 times. Load 0% idle conditions except the results improved engine warm-up characteristics. The exhaust noise obtain similar results the BASE+EHRS W/O_FRT_MUFF with BASE and back-pressure to obtain similar results BASE+EHRS W/O_FRT_ MUFF with BASE+EHRS.

Effect of the Presence of Corpus Luteum on Oocyte Recovery and Subsequent in vitro Maturation and Fertilization in Buffaloes

  • Singh, Sajjan;Dhanda, O.P.;Malik, R.K.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.12
    • /
    • pp.1675-1677
    • /
    • 2001
  • The effect of the presence or absence of corpus luteum in the ovaries of slaughtered buffaloes was studied for the oocytes recovery and their subsequent maturation and fertilization in vitro. On an average, 0.41 and 0.67 oocytes per ovary were recovered from ovaries with and without corpus luteum, respectively. Immature oocytes were matured in TCM-199 medium. Significant difference was observed in maturation rate between good (74%) and fair (37%) oocytes. However, there was no significant difference in cleavage rate between the two types. The results of this study show that although the presence of corpus luteum in the ovary at the time of recovery significantly affected availability of total oocytes and in-vitro maturation, but fertilization and cleavage remained unaffected under in vitro conditions.

Test of Heat Recovery Performance of a Microturbine (마이크로터빈의 열회수 성능시험)

  • Jeon, Mu-Sung;Lee, Jong-Jun;Kim, Tong-Seop;Chang, Se-Dong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.8
    • /
    • pp.629-635
    • /
    • 2008
  • Recently, microturbines have received attention as a small-scale distributed power generator. Since the exhaust gas carries all of the heat release, the microturbine CHP (combined heat and power) system is relatively compact and easy to maintain. Generating hot water or steam is usual method of heat recovery from the microturbine. In this work, a heat recovery unit producing hot water was installed at the exhaust side of a 30 kW class microturbine and its performance characteristics following microturbine power variation was investigated. Heat recovery performance has been compared for different operating conditions such as constant hot water temperature and constant water flow rate. In particular, the influence of water flow rate and hot water temperature on the recovered heat was analyzed.

A Study on the Change in the Film Thickness of Ball Bearing in Starved EHL (윤활유 부족 상태에서의 볼 베어링 유막 두께 변화에 대한 연구)

  • Jung, SoonBi;Lee, Bora;Yu, YongHun;Cho, YongJoo
    • Tribology and Lubricants
    • /
    • v.33 no.3
    • /
    • pp.119-125
    • /
    • 2017
  • In this study, we perform a numerical analysis to predict the film thickness and lubrication regions for a thrust ball bearing under different operating conditions. Film thinning and replenishment affect the film thickness in starved lubrication. As the inlet meniscus position is brought to the edge of the Hertz contact, the thin film thickness is calculated as starved equation. We use a film replenishment model to determine the recovery film thickness between rolling elements. We use a hydrodynamic model to describe film recovery, that results from the effects of surface tension. In this model, we consider the surface tension gradient in fluid depression as the driving force for fluid recovery. We use Fourier transform method to determine the time-dependent depth of depressed oil. We calculate the change in the central film thickness graphically by using the recovery equation in starved elastohydrodynamic lubrication(EHL) under operating conditions that include numbers of balls, sliding velocity, applied force, and ambient film thickness. We evaluate the degree of starvation by using the distance from the center of the contact area to the meniscus position. Parched lubrication, a phenomenon where the film thickness decreases consistently, occurs at the severe condition. We determine optimal values with respect to the numbers of balls, and sliding velocity. The investigation can contribute to the design operating conditions for proper lubrication.