외기온도와 환수온도를 이용한 보일러의 공급수온도설정 (Boiler Supply Water Temperature Setting by Outside Air Temperature and Return Water Temperature)

  • 한도영;유병강
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.161-166
    • /
    • 2009
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a boiler unit, the effective operation is necessary. In this study, the supply water temperature algorithm of a condensing gas boiler was developed. This includes the setpoint algorithm and the control algorithm of the supply water temperature. The setpoint algorithm was developed by the fuzzy logic and the control algorithm was developed by the proportional integral algorithm. In order to analyse the performance of the supply water temperature algorithm, the dynamic model of a condensing gas boiler system was used. Simulation results showed that the supply water temperature algorithm developed for this study may be practically applied for the control of the condensing gas boiler.

  • PDF

탄화수소 냉매의 수평 원관내 응축열전달 특성 (Condensing heat transfer characteristics of hydrocarbon refrigerants in a horizontal tube)

  • 장영수;김민수;노승탁
    • 대한기계학회논문집B
    • /
    • 제21권12호
    • /
    • pp.1656-1667
    • /
    • 1997
  • Condensing heat transfer characteristics of hydrocarbon refrigerants are experimentally investigated. Single component hydrocarbon refrigerants (propane, isobutane, butane and propylene) and binary mixtures of propane/isobutane and propane/butane are considered as test fluids. Local condensing heat transfer coefficients of selected refrigerants are obtained from overall conductance measurement. Average heat transfer coefficients at different mass fluxes and heat transfer rates are shown and compared with those of R22. Pure hydrocarbon refrigerants have higher values of heat transfer coefficient than R22. It is also found that there is a heat transfer degradation for hydrocarbon mixtures due to composition variation during condensation. Measured condensing heat transfer coefficients are compared with predicted values by available correlations. An empirical correlation for pure and mixed hydrocarbon is developed, and it shows good agreement with experimental data.

콘덴싱 가스보일러시스템의 제어 알고리즘 개발을 위한 효과적인 동적모델 (Effective Dynamic Models for the Development of Control Algorithms of a Condensing Gas Boiler System)

  • 한도영;김성학
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.34-39
    • /
    • 2007
  • Condensing gas boiler units may make a big role for the reduction of energy consumption in heating industries. In order to decrease the energy consumption of a condensing gas boiler unit, the effective operations and controls of the system are necessary. In this study, mathematical models of a condensing gas boiler system were developed and programmed in order to predict dynamic behaviors of the system. These include dynamic models for a blower, a gas valve, a pump, a burner, a boiler heat exchanger, and a hot water heat exchanger. Control algorithms for the control of a gas valve, a blower, and a pump were also assumed. Simulation results showed good predictions of the dynamic phenomena of a boiler system. Therefore, the simulation program developed for this study may be effectively used for the development of control algorithms of the boiler system.

  • PDF

응축수 순환이 폐열회수 응축형 보일러 성능에 미치는 영향 (Effect of Waste Heat Recovery Condensing Boiler with Condensed Water Recirculation Function)

  • 금국빈;김수익;유병훈;이창언
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.201-204
    • /
    • 2015
  • Recently, energy excessive consumption and environmental pollution are the social issued. The most efficient way to solve both energy excessive consumption and environmental pollution is existing combustion system improved. This study was part of the assume and commercial used existing waste heat recovery condensing boiler to low emission performance for exhaust gas recirculation(EGR) and thermal efficiency rise by applying the condensed water recirculation(CWR) conducted. The researchers applied the EGR and CWR develop a new concept for the condensed water recirculation waste heat recovery condensing boiler. Waste heat recovery condensing boiler applied to the condensed water recirculation thermal efficiency of the same conditions was increased by about 4.8~5.5% and pollution emission also decreased.

  • PDF

콘덴싱가스보일러 제어를 위한 공급수알고리즘 (The Supply Water Algorithm for a Condensing Gas Boiler Control)

  • 한도영;유병강
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.441-448
    • /
    • 2011
  • The energy consumption of a condensing gas boiler may be greatly reduced by the effective operation of the unit. In this study, the supply water algorithm for a condensing gas boiler control was developed by using the fuzzy logic. This includes the supply water set temperature algorithm, and the control algorithms of a gas valve, a blower and a pump. For the set temperature algorithm, the outside air temperature and the return water temperature were used as input variables. The supply water temperature difference and its slope were used as input variables of the gas valve and blower control algorithm. And the supply water temperature and the return water temperature were used as input variables of the pump control algorithm. In order to analyse performances of these algorithms, the dynamic model of a condensing gas boiler was used. The initial start-up test, the supply water set temperature change test, the outside air temperature change test, and the return water temperature change test were performed. Simulation results showed that algorithms developed in this study may be practically applied for the effective control of a condensing gas boiler.

수평 평활관 및 전열촉진관내 대체 냉매 R-407C의 응축 열전달 특성에 관한 연구 (Heat Transfer Characteristics of R-407C During Condensing Inside Horizontal Smooth and Micro-Fin Tubes)

  • 노건상;오후규
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.210-217
    • /
    • 1999
  • This paper reports the experimental results on heat transfer characteristics of R-22 and R-407C(HFC-32/125/134a 23/25/52 wt%) condensing inside horizontal smooth and finned tubes. The test condensers used In the study are double pipe heat exchangers of 7.5 mm ID, 9.5 mm OD smooth tube, and 60 finned micro-fin tube with 8.53 mm ID, 9.53 mm OD. Each of these tubes was 4 000 mm long tubes connected with an U-bend. These U type two-path test tubes are divided In 8 local test sections for the identification of the local condensing heat transfer characterisitcs and pressure drop, U-bend effects on condensing flows. Inlet quality is maintained 1.0, and refrigerant mass velocity is varied from 102.0 to $301.0kg/m^2{\cdot}s$. From the results, it was found that the pressure drop of the R-407C Increased, and heat transfer coefficient decreased compared to those of R-22. In comparison condensing heat transfer characteristics of micro-fm tube with those of smooth tube, increasing of condensing heat transfer coefficient was found outstanding compared to the increasing ratio of pressure drop. Furthermore, pressure drop In U-bend showed at most a 30 % compared to the total pressure drop in the test section.

풀비등에서 소형 사각기둥핀 배열형상에 따른 FC-72의 응축특성 (Condensing Characteristics of Pin-finned Surfaces on Pool Boiling in FC-72)

  • 강상우;김서영
    • 설비공학논문집
    • /
    • 제23권7호
    • /
    • pp.498-504
    • /
    • 2011
  • As the electronic industry rapidly develops, the heat flux from state-of-the-art electronics increases up to $10^6\;W/m^2$. For this reason, the development of a new cooling technology for high heat flux applications is strongly required. Recently, some cooling technologies using boiling and condensation of working fluid are being adopted to overcome such a technical barrier. In the present study, a smooth boiling surface ($14{\times}14\;mm^2$) was immersed in FC-72 and its vapor was condensed by four different types of condensation surfaces ($30{\times}30\;mm^2$ base). The condensing surfaces were composed of a smooth surface and $1{\times}1\;mm^2$ pin-finned surfaces of 2 mm height with 0.3, 0.5 and 1 mm array spacing. Boiling and condensing characteristics were investigated in detail on their combinations of boiling and condensing surfaces. For a smooth boiling surface the results obtained showed that the pin-finned condensing surface with 1 mm array spacing yielded the best performance and the smooth condensation surface did the worst. Furthermore hysteresis phenomena could be reduced by using enhanced condensing surfaces.

액체상흡착제(HMDS) 주입조건에 따른 응축성 가스상 물질의 거동특성 비교 (Behaviour of Condensing Gaseous Species by Injection of Liquid Adsorbents (HMDS) in Combustion Facility)

  • 김용구;이상열;봉춘근;김현상
    • 대한환경공학회지
    • /
    • 제37권5호
    • /
    • pp.285-292
    • /
    • 2015
  • 본 연구에서는 바이오매스의 탄화공정 시 발생되는 목초액을 응축성 가스물질의 전구물질로 이용하여 발생되는 응축성 가스상 오염물질을 제거하기 위하여 액체상 흡착제중 실리카 전구물질인 HMDS의 주입조건에 따른 응축성물질의 입경분포 변화특성을 명확히 파악하고자 하였다. 응축성 가스상 물질을 입자화시켜 제거하기 위하여 액체상 흡착제인 HMDS를 이용할 경우, 흡착제의 주입량, 체류시간 및 가열온도, MFC 유량 등의 적절한 조절로써 입자화 크기를 조절할 수 있었다. 특히 실리카 전구물질을 도입시 끓는점, 밀도(비중), 분자량 등의 물리화학적 특성을 고려하면, 발생되는 응축성 물질을 효과적으로 입자화시켜 제어 가능할 것으로 판단된다.

Digital Subtraction Radiography를 이용한 근관치료 후 골회복의 정량적평가에 관한 연구 (A QUANTITATIVE STUDY OF BONE REPAIR AFTER ENDODONTIC THRAPY ON DIGITAL SUBTRACTION RADIOGRAPHY)

  • 김재덕
    • 치과방사선
    • /
    • 제27권2호
    • /
    • pp.15-25
    • /
    • 1997
  • This study was performed to prepare the quantitative method of judging the sensitive prognosis of chronic apical periodontitis as early as possible. The subjects were 25 cases with periapical radiolucencies of which were treated with endodontic treatment. Serial radiographs were taken by standardized method longitudinally. The density slice function of digital radiographic system were employed for quantitative and longitudinal assessment of the radiolucent area and the condensing osteitis simultaneously. Obtained results were as follows: 1. The amount of bone repair after endodontic treatment could be detected quantitatively by the density slice function of digital radiographic system. 2. Within the 6-week period after root canal filling, the prognosis could be evaluated by assessment both radiolucent area and condensing osteitis on digital radiographic system. 3. The pattern of bone repair showed peripheral type in most cases from the 6th week after root canal filling. 4. In longitudinal change, bone repair showed two patterns; the succeeding reduction of radiolucent area showing the increase of condensing osteitis in size till 6th week and following by static state or reduction tendency and the reduction following the initial increase of both areas. 5. Cases with pulpitis by trauma showed initial increase of condensing osteitis at 2nd week, marked reduction of radiolucent area and condensing osteitis at 6th week, and approximately normal bone state at 8th week after root canal filling.

  • PDF

비공비혼합냉매를 사용하는 열펌프의 응축열전달 특성 (Condensing Heat Transfer Characteristics on a Heat Pump System Using Non-Azeotropic Refrigerant Mixtures)

  • 박기원;오후규;김욱중
    • 대한기계학회논문집
    • /
    • 제19권4호
    • /
    • pp.1125-1133
    • /
    • 1995
  • Experiments were performed to investigate the condensing heat transfer characteristics of non-azeotropic mixtures of R-22 and R-114 in a heat pump system with a horizontal smooth tube as a condenser. The ranges of parameters, such as heating capacity, mass flow rate of refrigerant and quality were 780-3,480W, 24-71kg/h, and 0-1, respectively. The overall compositions of R-22 in a R-22/114 mixture were 25, 50, 75 and 100 per cent by wight. The results show that the overall condensing heat transfer coefficients for the mixtures were lower than the pure R-22 values. Local heat transfer coefficient of the pure R-22 was hghest at the top of the test tube. The local heat transfer coefficient of R-22/114 (50/50 wt%) at side and bottom of the test tube was higher than that at the top. From the obtained data, a prediction for the condensing heat transfer coefficients of the mixture was done based on the method of Fujii.