• Title/Summary/Keyword: Condensed Water

Search Result 169, Processing Time 0.029 seconds

Use of condensed molasses fermentation solubles as an alternative source of concentrates in dairy cows

  • Ma, Jian;Ma, Chen;Fan, Xue;Shah, Ali Mujtaba;Mao, Jiang
    • Animal Bioscience
    • /
    • v.34 no.2
    • /
    • pp.205-212
    • /
    • 2021
  • Objective: The purpose of present study was to investigate the effects of condensed molasses fermentation solubles (CMS) on lactation performance, rumen fermentation, nutrient digestibility, and serum parameters of dairy cows. Methods: A total of 75 healthy Holstein cows with the same parity (milk production = 35±2.5 kg, body weight = 570±28 kg) were randomly selected and divided into 5 groups. One group served as control group (CON; no CMS), whereas the other 4 groups were CMS1 (accounted for 1% of the diet), CMS2 (2%), CMS3 (3%), and CMS4 (4%). All cows were fed regularly three times each day at 0800, 1600, and 2400 h. Cows received diet and water ad libitum. The experiment lasted for 60 days. Results: Results showed that the dry matter intake, milk yield, and protein of CMS2 were maximum and higher (p<0.05) than CMS4. The ruminal pH was observed less than 6 in CMS3 and CMS4 groups. No noticeable difference of microbial protein was found between CON and CMS2 groups, while the microbial protein in these groups was higher (p<0.05) than CMS3 and CMS4 groups. The apparent digestibility of dry matter, organic matter, and crude protein in CMS2 group was higher (p<0.05) than CMS3 and CMS4 groups. Compared to CMS3 and CMS4 groups, the CMS2 group increased (p<0.05) the serum concentrations of immunoglobulin G and immunoglobulin M on d 60. Conclusion: Therefore, it is practicable that CMS substitutes for a part of concentrates in lactating cows' diets, but higher addition of CMS (more than 3% of the diet) could decrease production performance of dairy cows as seen in the present study.

Use of Chemical Treatments to Reduce Tannins and Trypsin Inhibitor Contents in Salseed (Shorea robusta) Meal

  • Mahmood, S.;Khan, Ajmal M.;Sarwar, M.;Nisa, M.;Lee, W.S.;Kim, S.B.;Hur, T.Y.;Lee, H.J.;Kim, H.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.20 no.9
    • /
    • pp.1462-1467
    • /
    • 2007
  • This study investigated the effect of chemical treatments on tannins (condensed and hydrolysable) and on the trypsin inhibitor (TI) activity in salseed meal. Triplicate samples of ground salseed meal (1 kg) were mixed with 820 ml of either distilled water (pH 5.3), 0.67 M acetic acid (pH 2.4), 0.67 M sodium bicarbonate (pH 8.2) or 2% polyvinyl-pyrrolidone (PVP) solution. The material was placed in airtight plastic containers and incubated at $37^{\circ}C$ for 0, 3, 6, 12, 24, 48 and 72 h. Samples of untreated salseed meal which had not been subjected to soaking or incubation were run through the analysis to serve as control. Addition of water, acetic acid, sodium bicarbonate and PVP solutions to salseed meal and subsequent anaerobic incubation at $37^{\circ}C$ significantly reduced chemically detectable tannins. At each incubation time, alkali solution was more effective than its counterparts. The effect of acidic solution on hydrolysable tannin was least among the treatments. All the treatments reduced TI activity of salseed meal. The reduction in TI activity by these treatments was similar and ranged between 80-84%. Treatment time effected a decrease in the contents of antinutritional substances. However, the effect of the treatment with the reagents, even for zero incubation time, was quite pronounced. It may be concluded from the present results that the treatment of salseed meal with sodium bicarbonate (0.67 M) is more effective in reducing hydrolysable and condensed tannin contents than PVP, water and acid solutions. Treatment with sodium bicarbonate solution is more economical and easier to handle than acid and PVP treatments. Incubation of the treated material for 12 h is reasonably effective, economical and safe from any mould growth.

Extraction of organic carbon from the condensate of food waste dry feed process (음식물류폐기물의 건식사료화 공정에서 발생되는 응축수로부터 유기탄소 추출)

  • Kim, Min-Kyung;Kwon, Ki-Wook;Mo, Kyung;Cui, Feng-Hao;Park, Se-Yong;Kim, Moon-Il
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.28 no.2
    • /
    • pp.41-48
    • /
    • 2020
  • In this study, organic carbon was extracted from the condensed water of food waste drying process to estimate the applicability as external organic carbon sources. The COD, TN, TP and TS of condensed water were 21,374 mg/L, 148 mg/L, 4.19 mg/L, and 455.7 mg/L, respectively. In addition, the content of biodegradable organics in condensed water was 47%. The fractional distillation and the vacuum evaporation were employed for extracting organic carbon. There were 8 extraction conditions, but 4 conditions were available for extraction. They were 1) 0mmHg, 110℃ 2) -600mmHg, 70℃ 3) -500mmHg, 80℃ 4) -600mmHg, 80℃. All 4 conditions showed the highest organic concentration and the highest quantity of organics when extracted 10% of initial volume. It was estimated that optimum conditions were 80℃, -600mmHg and 10% extraction. Then, extraction concentration, extraction quantity, extraction efficiency, extraction time, BOD/TCOD ratio, TVFAs/TCOD ratio and NH3-N were 174,200 mg/L, 8,710 mg, 46%, 10 min, 0.97, 0.74 and 75.5 mg/L respectively. Therefore, the extracted organic carbon can be utilized as external organic carbon sources.

Processing Characteristics of the Condensed Wastewater Resulting from Food Waste Disposal using a Submerged Polyethylene Hollow Fiber Membrane (음식물 소멸기에서 발생하는 응축폐수의 Polyethylene 침지형 중공사막을 이용한 처리 특성)

  • Ryu, Jae-Sang;Jeon, Tae-Bong;Kim, Jin-Ho;Chung, Kun-Yong
    • Membrane Journal
    • /
    • v.20 no.2
    • /
    • pp.127-134
    • /
    • 2010
  • This study is conducted about the system that reduces organism after fermenting food waste from a food waste disposal equipment, divides gas made when food waste is fermented into gas and water, and then sends gas to a reactor again, condenses water, and apply it to the MBR system with submerged MF hollow fiber membranes. A submerged MF hollow fiber membrane module was installed to a food waste disposal equipment and a water treatment system made by Bio Hitech Co,. Ltd. to process food waste generated from a staff cafeteria in a H institute for 90 days. For initial seeding of a food waste disposal equipment, 305 kg of rice bran, chaff, and sawdust as well as 1,648 kg of food were input during the operation, and 1,600 L of condensed wastewater occurred. Fermented by-product after finishing running a food waste disposal equipment was 386 kg and its reduction was shown to be 80%. The organism was processed by applying submerged MF hollow fiber membrane module to the MBR system of condensed wastewater, and the result shows reduction rates were BOD 99.9%, COD 97.5%, SS 98.6%, T-N 54.6% and T-P 34.7% and the total colon bacillus was perfectly eliminated.

A Study on the Effects of System Pressure on Heat and Mass Transfer Rates of an Air Cooler

  • Jung, Hyung-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.696-702
    • /
    • 2002
  • In the present paper, the effects of inlet pressure on the heat and mass transfer rates of an air cooler are numerically predicted by a local analysis method. The pressures of the moist air vary from 2 to 4 bars. The psychrometric properties such as dew point temperature, relative humidity and humidity ratio are employed to treat the condensing water vapor in the moist air when the surface temperatures are dropped below the dew point. The effects of the inlet pressures on the heat transfer rate, the dew point temperature, the rate of condensed water, the outlet temperature of air and cooling water are calculated. The condensation process of water vapor is discussed in detail. The results of present calculations are compared with the test data and shows good agreements.

Angular Dispersion-type Nonscanning Fabry-Perot Interferometer Applied to Ethanol-water Mixture

  • Ko, Jae-Hyeon;Kojima, Seiji
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.2
    • /
    • pp.261-266
    • /
    • 2009
  • The angular dispersion-type non-scanning Fabry-Perot was applied to an ethanol-water mixture in order to investigate its acoustic properties such as the sound velocity and the absorption coefficient. The scattered light from the mixture was analyzed by using the charge-coupled-device area detector, which made the measurement time much shorter than that obtained by using the conventional scanning tandem multi-pass Fabry-Perot interferometer. The sound velocity showed a deviation from ultrasonic sound velocities at low temperatures accompanied by the increase in the absorption coefficient, indicating acoustic dispersion due to the coupling between the acoustic waves and some relaxation process. Based on a simplified viscoelastic theory, the temperature dependence of the relaxation time was obtained. The addition of water molecules to ethanol reduced the relaxation time, consistent with dielectric measurements. The present study showed that the angular dispersion-type Fabry-Perot interferometer combined with an area detector could be a very powerful tool in the real-time monitoring of the acoustic properties of condensed matter.

A study on the development of the high efficiency condensing heat exchanger (고효율 응축형 열교환기 개발에 관한 연구)

  • Lee, Geum-Bae;Park, Sang-Il;Park, Jun-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.5
    • /
    • pp.589-601
    • /
    • 1997
  • A computer simulation program of a high efficiency condensing heat exchanger is developed. The flue gas flows outside bare tube bundles both in strong cross flow and in weak counter flow and the cooling water inside the tubes. Condensing heat exchangers achieve high efficiency by reducing flue-gas temperatures to a level at which most of the water vapor in the flue gas is condensed and the latent heat associated with phase change of the water is recovered. The computer model has been verified by comparison with measured data. To verify the model, heat transfer coefficient was adjusted, along with the mass transfer diffusion coefficient and pressure drop coefficient, to achieve agreement between predicted and measured data. The efficiencies of heat exchanger increase 2.3 ~ 8.1% by condensations of 6.3 ~ 62.6% of the water vapor in the flue gas.

Polymer Supported Cyanide as an Efficient Catalyst in Benzoin Condensation: An Efficient Route to α-Hydroxy Carbonyl Compounds

  • Kiasat, Ali Reza;Badri, Rashid;Sayyahi, Soheil
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.1164-1166
    • /
    • 2009
  • Aromatic aldehydes are efficiently self-condensed into $\alpha$-hydroxy carbonyl compounds by polystyrene-supported ammonium cyanide as an excellent organocatalyst in C-C bond formation. The reaction proceeds in water under mild reaction conditions. The polymeric catalyst can be easily separated by filtration and reused several times without appreciable loss of activity.

Superhydrophobic Surfaces for condensation by using spray coating method

  • Oh, Seungtae;Seo, Donghyun;Lee, Choongyeop;Nam, Youngsuk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.157.2-157.2
    • /
    • 2016
  • Water repellent surfaces may enhance the condensation by efficiently removing the condensed droplets. However, such surfaces may lose their original performance as they are exposed to external mechanical stresses. In this work, we fabricated spray-coated mechanically robust superhydrophobic surfaces using treated titanium dioxide (Type 1) or silica particles (Type 2). Then we compared the mechanical robustness of such surfaces with the silane-coated superhydrophobic surface and PEEK coated surface using a controlled-sand blasting method. The results show that the spray-coated samples can maintain the same level of the contact angle hysteresis than silane-coated superhydorphobic surface after sand blasting at 2 bar. The spray-coating method was applied to the tube type condenser and the condensation behaviors were observed within the environmental chamber with controlled pressure, humidity and non-condensable gas. Previously-reported droplet jumping was observed in the early stage of the condensation event, but soon the droplet jumping stopped and only dropwise condensation was observed since the condensed droplets were pinned on the cracks at spray-coated surfaces. The static contact angle decreases from $158.0^{\circ}$ to $133.2^{\circ}$, and hysteresis increases from $3.0^{\circ}$ to $23.5^{\circ}$ when active condensation occurs on such surfaces. This work suggests the benefits and limitation of spray-coated superhydrophobic condensers and help develop advanced condensers for practical use.

  • PDF

Automated On-Line Digestion System for the Determination of Total Phosphorus (총 인 분석을 위한 자동 전처리 시스템)

  • 정형근;조영일;김범식;박주형
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.13-19
    • /
    • 2001
  • An on-line digestion system based on the flow injection analysis technique was presented for the determination of total phosphorus. The system converts condensed and organic phosphoruses into orthophosphate that can be analyzed spectrophotometically. The reaction between orthophosphate and ammonium molybdate in a strong acid medium forms the yellow complex of phosphomolybdate which is next reduced to a molybdic blue complex by stannous chloride. The quantitation of orthophosphate is based on the absorbance of the molybdic blue. To determine total phosphorus, the digestion system was installed between the sample injector and the reaction coil with the added lines of digestion solution(potassium persulfate+sulfuric acid) and the $H_2O$ carrier. The system has shown that the digestion efficiencies were greater than 95% for the typical condensed and organic phosphoruses. When tripolyphosphate standards were used, the calibration data showed that the linear dynamic range extended to a concentration of 1.5ppm with the detection limit of 25ppb total phosphorus. The typical relative standard deviation was less than 2%. The proposed system was successfully applied to lake water, wastewater, and streamwater. The analytical variables such as digestion efficiency, analysis time, and reproducibility were evaluated and compared with the manual digestion method.

  • PDF