• 제목/요약/키워드: Condensation Efficiency

검색결과 170건 처리시간 0.025초

사무공간 적용 BIPV시스템의 자연채광 및 성능평가에 관한 연구 (A Study on Evaluation of Daylighting in Office Space Applied BIPV Systems in Accordance with Power Performance)

  • 서영석;오민석;김회서
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.148-154
    • /
    • 2009
  • By the skyscraper building, increase of skin area and expansion of curtain wall system will be the important factors of acceleration in extending supply of BIPV system. In the future interior environmental evaluation is not a necessary to the residents but an essential term which will bring enormous influence. In the interior environmental evaluation, natural light will let the residents with direct contact with outside circumstances and make them feel opened. also only the daylight has radiant energy and color rendering that will have a great influence to residents' mental, operation efficiency and advancing productivity. This research compares and analyzes BIPC system in office spaces with two general sunlight's module. In addition to natural light's efficiency for BIPC system's comfort and confirmed economical efficiency will be applied to basic research data. Hence forth, ensuring indoor intensity of illumination and controlling light system to reducing energy research data will be demanded to increase the amount of supplying BIPC system. Also continuance research in the possibility of applying BIPC system in various buildings, room temperature affected by location of windows and its condensation, and economical evaluation will be required.

  • PDF

실증운전을 통한 배가스 열회수 히트펌프 시스템의 성능 분석 (Analysis of Performance of Heat Pump System with Flue Gas Heat Recovery through Field Test)

  • 이승호;이길봉;이영수;박상일;고창복;백영진;이관수
    • 설비공학논문집
    • /
    • 제26권1호
    • /
    • pp.1-7
    • /
    • 2014
  • A field test of a 70 kW heat pump system with flue gas heat recovery was performed by an experiment at the Korea Institute of Energy Research. The flue gas is exhausted from a 320 RT absorption chiller-heater in the heating season. Using this flue gas, source water of the heat pump is heated by a condensed-type heat exchanger in the chimney. The operating characteristics of the heat recovery heat pump system were analyzed. Based on the results of the experiments, operating maps were obtained, and an optimum operating range is suggested, in which the return and heat source water temperature are $51^{\circ}C$ and $31^{\circ}C$, respectively. Additionally, economic analysis of this system was conducted and about 50% energy cost savings can be expected in the heating season.

건물 적용을 위한 태양열 집열기 기능을 갖는 BIPV 시스템의 기초적 연구 (A Fundamental Study of BIPV System Functioned as Solar Collector for Building Application)

  • 민성혜;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.91-98
    • /
    • 2007
  • Perimeter zone is one of the weakest area in buildings and it makes an increase of heating and cooling loads, in addition to condensation or discomfort with cold-draft to residents in winter. Because of this, it needs to be reinforced by active systems. However, they use fossil fuel, and ultimately greenhouse effect is urged. Thus, we proposed BIPV system functioned as solar collector which can substitute active system. As an fundamental stage, heat balance equation in steady-state by Fortran was used not only, in winter for pre-heating effect and electric power capacity during the day, but also in summer, for the latter during the day and sky radiation effect during the night. Especially, we should have considered shading on PV by IES Suncast, since even a little bit of it makes the efficiency too low for the PV modules to work. As a result, in summer day, the PV panel should be tiled in 70 degrees to gain the most electric power. Moreover, we could verify that this model makes higher temperature and heat flux under 0.02 m/s. On the other hand, the PV had the high efficiency with high velocity because of cooling effect behind the PV. Therefore, we should regard the air current distribution later on.

PN-PEMS 장비의 개발 및 평가 (Development and Performance Evaluation of PN-PEMS)

  • 황인규;김민호;우승철;이기형;안강호
    • 한국입자에어로졸학회지
    • /
    • 제10권4호
    • /
    • pp.163-167
    • /
    • 2014
  • Particle number portable emission measurement system (PN-PEMS) is an instrument for measuring number concentration of automobile exhaust. The principle of some pre-existing commercial PN-PEMS is to charge particles and display the number of particles by measuring current. However, this method has some problems for measuring exhaust. In this study, to solve these issues, we have developed a single particle counting PN-PEMS based condensation particle counter (CPC). The PN-PEMS based CPC does not affect driving conditions and it is convenient for mobile because the instrument is small and light in structure. We evaluated counting efficiency of PN-PEMS based CPC by using electrostatic method (electrometer and Faraday cup).

응축기 배열 회수에 의한 흡수식 냉동기의 고효율화에 관한 연구 (A study on the Characteristics of the High Efficiency absorption Chiller by Heat Recovering from Condenser)

  • 박찬우
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.46-51
    • /
    • 2006
  • In order to utilize the refrigerants condensation heat of condenser on the absorption chiller system, the solution cooling condenser(SCC) were proposed, which weak solution of absorber outlet use as a cooling water. As the UA of the solution cooling condenser increased, increasement of COP is about maximum 0.09 in occasion of single effect and is about maximum 0.08 in occasion of double effect series flow. In the case of heat exchanger efficiency is about 0.85, it's increments are 0.08 and 0.072, each. And solution cooling condenser is a more effective device in the single effect absorption system more than double effect system for the principle of operation. In order to increases the heat of solution cooling condenser, if reduce the flow rate of cooling water or the value of UA, it makes COP increase a little, but it brought COP decrease because of increasing the pressure of system.

  • PDF

코로나 샤워 시스템을 이용한 NOx제거에서 $SO_2$의 영향 (The $SO_2$ effect on NOx removal by Corona Shower System)

  • 박재윤;김익균;이재동;김종달;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1794-1796
    • /
    • 1998
  • In this study, the $SO_2$ addition effect on NOx removal has been conducted from a combustion flue gases by the do corona discharge-activated radical shower systems. The simulated flue gases were consisted of NO-O_2-$N_2$, NO-$CO_2-N_2-O_2$ and $NO-SO_2-CO_2-Na-O_2$([NO]o:200ppm and $[SO_2]o$:800ppm). The injection gases used as radical source gases were $NH_3$-Ar-air. $SO_2$ and NOx removal efficiency and the other by-products were measured by Fourier Transform Infrared(FTIR) as well as $SO_2$. NOx and $NO_2$ gas detectors. By-product aerosol particles were also observed by Condensation Nucleation Particle Counter(CNPC) and SEM images after sampling. The results showed that asignificant aerosol Particle formation was observed during a removal operation in corona radical shower systems. The NOx removal efficiency significantly increased with increasing applied voltage and $NH_3$ molecule ratio. The $SO_2$ removal efficiency was not significantly effected by applied voltage and slightly increased with increasing $NH_3$ molecule ratio. The NOx removal efficiency for NO-$SO_2-CO_2-N_2-O_2$ was better than that for NO-$CO_2-N_2-O_2$.

  • PDF

졸-겔법에 의한 $TiO_2-SiO_2$합성 및 광촉매활성 (Preparation of $TiO_2-SiO_2$ by Sol-Gel Method and Their Photocatalytic Activities)

  • 류완호;양천희
    • 한국안전학회지
    • /
    • 제14권1호
    • /
    • pp.101-107
    • /
    • 1999
  • $TiO_2$ and $xTiO_2-ySiO_2$ system photocatalysts were developed by sol-gel method based on the change of production parameters, and their structure of crystallization and the specific surface area was measured. Considering the efficiency of the ethanol decomposition using the catalyst, the conclusion was made as follows: 1) By means of X-ray analysis of $TiO_2$ powder that is obtained from water and Titanium alkoxide with various molar ratios, it is shown that structure of crystallization is a dominating structure and, on the other hand, the crystallization of rutile also partly exists. The specific surface area is at its maximum value at R=6, which is the molar ratio of water vs. alkoxide, whereas its value goes down as the molar ratio increases. In the reaction of using $TiO_2$ catalyst, the ethanol is decomposed into the extent of 15 ~30% in an hour and three hours are necessitated for 70% decomposition. 2) $TiO_2/SiO_2$ powder is developed from Titanium and Silicon alkoxide by a hetero-condensation process. The increase of SiO$_2$ contents causes the decrease of the degree of crystallization of the gel, whereas the specific surface area preferentially increases. In the decomposition reaction of the ethanol, the decomposition efficiency represents 25~60% in an hour. It is, however, examined that the efficiency inactively increases corresponding to the duration of reaction time. It is shown that more than 90% of ethanol is decomposed when reaction time is about three hours and the efficiency illustrates the maximum value for 60-$TiO_2/4O-SiO_2$ catalyst.

  • PDF

저온 열원과 LNG 냉열을 이용하는 암모니아-물 동력 사이클의 열역학적 성능 해석 (Thermodynamic Performance Analysis of Ammonia-Water Power Generation System Using Low-temperature Heat Source and Liquefied Natural Gas Cold Energy)

  • 김경훈;김경천
    • 대한기계학회논문집B
    • /
    • 제38권6호
    • /
    • pp.483-491
    • /
    • 2014
  • 본 연구에서는 현열 형태의 저온 열원과 LNG의 냉열을 이용하는 복합 동력 생산시스템에 대한 열역학적 성능 해석을 수행하였다. 시스템의 작동유체로서 암모니아-물의 비공비 혼합물을 고려하였으며 재생기가 없는 기본 사이클과 있는 재생 사이클의 경우를 비교 해석하였다. 작동유체의 암모니아 농도나 응축 온도에 따라 시스템의 순생산일, 엑서지 파괴, 열효율이나 엑서지 효율 등에 미치는 다양한 영향에 대해 분석하고 논의하였다. 해석 결과는 시스템의 성능 특성이 작동유체의 암모니아 농도나 응축 온도에 따라 민감하게 변화하며, 열원유체 단위질량당 순생산일은 기본 사이클이 유리하나 열효율이나 엑서지 효율은 재생 사이클이 유리하다는 사실을 보여준다.

수분수집을 위한 초발수/초친수 복합 표면 제작: 그라비아 옵셋 프린팅과 콜로이달 리소그래피 공정 (Fabrication of a Hybrid Superhydrophobic/superhydrophilic Surface for Water Collection: Gravure Offset Printing & Colloidal Lithography)

  • 지승묵;김인영;김은희;정지은;김완두;임현의
    • 한국정밀공학회지
    • /
    • 제29권1호
    • /
    • pp.19-24
    • /
    • 2012
  • We demonstrate the desert beetle back mimicking hybrid superhydrophilic/superhydrophobic patterned surface by using the combination method of colloidal lithography and gravure offset printing for nano and micro patterning, respectively. The two methods are cost-effective and industrially available techniques compared to the other nano/micro patterning methods. To verify the water collecting function of the hybrid surface, the water condensation behavior is investigated on the chilled surface in ambient temperature and high humidity. Due to the synergetic effect of drop and film wise condensation, the hybrid superhydrophobic/superhydrophilic surface shows the higher efficiency than one of single wettability surfaces. The work is underway to get the good patterns of hybrid surfaces for water collecting from the dew or fog.

개구부가 있는 고층 벽식 구조물의 효율적인 3차원 해석 (Efficient Three Dimensional Analysis of High-Rise Shear Wall Building with Openings)

  • 김현수;남궁계홍;이동근
    • 한국전산구조공학회논문집
    • /
    • 제15권2호
    • /
    • pp.351-365
    • /
    • 2002
  • 현재 국내에서는 벽체와 바닥판으로만 구성된 벽식 구조형식의 아파트 건물이 많이 사용되고 있다. 또한 청력에 대한 저항이 뛰어나기 때문에 전단벽 코어를 갖는 입체골조구조물이 고층 빌딩의 구조시스템으로 자주 이용된다. 기능적인 이유로 인해 이러한 구조물들의 전단벽에는 하나 또는 여러 개의 개구부가 발생하게 된다. 개구부가 있는 전단벽을 정확하게 해석하기 위해서는 여러 개의 유한요소를 사용하여 구조물을 세분모형화하는 것이 필요하다. 그러나, 전체 구조물을 유한요소로 세분하여 모형화하는 것은 막대한 해석시간과 컴퓨터 메모리를 소요하게 된다. 개구부의 수, 크기, 위치에 상관없이 적용할 수 있는 효율적인 해석기법이 본 논문에서 제안되었다. 제안된 해석기법에서는 슈퍼요소와 부분구조, 행렬응축, 가상보 등을 이용하였고 제안된 해석기법의 효율성을 검증하기 위해 벽식구조물과 전단벽 코어를 갖는 입체골조구조물의 3차원 해석이 수행되었다. 예제구조물의 해석을 통해 제안된 해석기법이 해석시간과 컴퓨터메모리를 크게 감소시키고, 정확한 해석결과를 얻을 수 있음이 확인되었다.