• Title/Summary/Keyword: Condensation Efficiency

Search Result 170, Processing Time 0.031 seconds

Structural Topology Optimization Using Two-level Dynamic Condensation Scheme (2단계 동적 축소법을 적용한 구조물의 위상 최적 설계)

  • Park Soo-Hyun;Kim Hyun-Gi;Cho Maeng-Hyo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.2 s.72
    • /
    • pp.213-219
    • /
    • 2006
  • Topology optimization problem requires numerous repeated evaluations of objective function and design sensitivity for elements within design domain with various density distributions. The recently proposed two-level condensation scheme(TLCS) is very promising for the construction of reduced system and for an accurate and efficient analysis concerned about eigenvalue and dynamic problems. We used the two-level dynamic condensation scheme for the analysis and sensitivity computation part in the structural topology optimization problem. The results of the topology optimization for the reduced system show the TLCS provides high accuracy and computation efficiency compared to the full scale system within engineering accuracy.

Forecast on Internal Condensation at Balcony Ceiling of Super-high Apartment Building Faced with Open Air (외기에 면한 초고층 아파트 발코니 천정 내부결로 예측)

  • Choi Yoon-Ki;Ahn Jae-Bong
    • Korean Journal of Construction Engineering and Management
    • /
    • v.4 no.4 s.16
    • /
    • pp.155-163
    • /
    • 2003
  • There are a growing number of cases to expand balconies of apartments faced with open air in order to enhance functional satisfaction and efficiency of dwelling space. In case of the balcony expansion at the floor, however, it is difficult to exclude a possibility of bringing about internal condensation due to the difference of temperature between indoor air and outdoor air caused by the Inflow of outer low-temperature air through the upper part of ceilings by failure in completely putting together the outer composite wall panels on the aluminum curtain walls installed at outer walls This study is to forecast possible occurrence of internal condensation around parapets and H-beam located at the inside of balcony ceilings on the uppermost floor of super-high apartment buildings faced with open air in order to provide dwellers with more comfortable environment in the related space and get rid of their uneasiness about the condensation. In this study, we estimated internal condensation, which vary in accordance with humidity pressure distribution, at curtain walls, stone panels or lower parts of slabs that constitute outer space of the residence and are weak against heat, through temperature forecast and temperature distribution interpretation program at normal two-dimension temperature

Local Nonlinear Static Analysis via Static Condensation (강성응축기법을 이용한 국부 비선형 정적 해석)

  • Shin, Han-Seop;Oh, Min-Han;Boo, Seung-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.1
    • /
    • pp.193-200
    • /
    • 2021
  • In this study, an analysis technique using static condensation is proposed for an efficient local nonlinear static analysis. The static condensation method is a model reduction method based on the degrees of freedom, and the analysis model is divided into a target part and a condensed part to be omitted. In this study, the nonlinear and linear parts were designated to the target and the omitted parts, respectively, and both the stiffness matrix and load vector corresponding to the linear part were condensed into the nonlinear part. After model condensation, the reduced model comprising the stiffness matrix and the load vector for the nonlinear part is constructed, and only this reduced model was updated through the Newton-Raphson iteration for an efficient nonlinear analysis. Finally, the efficiency and reliability of the proposed analysis technique were presented by applying it to various numerical examples.

Exergy Analysis of R744 OTEC Power Cycle with Operation Parameters (작동변수에 따른 R744용 해양온도차 발전 사이클의 엑서지 분석)

  • Yoon, Jung-In;Son, Chang-Hyo;Baek, Seung-Moon;Kim, Hyeon-Ju;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.8
    • /
    • pp.1036-1042
    • /
    • 2012
  • This paper describes an analysis on exergy efficiency of R744 OTEC power system to optimize the design for the operating parameters of this system. The operating parameters considered in this study include subcooling and superheating degree, evaporation and condensation temperature, and turbine and pump efficiency, respectively. The main results are summarized as follows : As the evaporation temperature, superheating degree, and turbine and pump efficiency of R744 OTEC power system increases, the exergy efficiency of this system increases, respectively. But condensation temperature and subcooling degree of R744 OTEC power system increases, the exergy efficiency of this system decreases, respectively. The effect of evaporation temperature and pump efficiency on R744 OTEC power system is the largest and the lowest among operation parameters, respectively. Therefore, the refrigerant temperature in the evaporator must be closely to the surface seawater temperature to enhance the exergy efficiency of R744 OTEC power system.

COMPARISON OF CANAL FILLING EFFICIENCY ON THE INTERNALLY RESORBED ROOT ACCORDING TO CANAL FILLING TEHNIQUES (근관충전방법에 따른 내흡수 치근의 근관충전 효율성 비교)

  • Ha, Sang-Yoon;Shin, Dong-Hoon;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.789-801
    • /
    • 1995
  • Canals with artificially made internal resorption were filled with 4 techniques(Lateral condensation, Ultrafil, Obtura II, Thermafil) to compare the efficacy of canal filling according to the filling techniques. After canal filling, radiographic examination, dye penetration through the apical portion and percentage of G-P filled area on the internal resorption area were evaluated. To examine the degree of crystal-like structure and the interface between filled G-P and canal wall, SM and SEM images were taken too. The results were as follows : 1. There was no statistically significant difference in apical microleakage among the 4 root canal filling techniques. 2. As a result of radiographic examination, Ultrafil was the best and Obtura II was acceptable but Lateral condensation and Thermafil showed unfavorable canal filling pattern similarly. 3. Ultrafil filled most of artificially made internal resorption area and Obtura II, Lateral condensation, Thermafil in that order filled unfavorably. 4. Degree of crystal like structure was the highest in the group filled with Ultrafil and those of Obtura II and Thermafil were similar and that of gutta percha used in Lateral condensation showed the lowest value. 5. Penetration of gutta percha into the dentinal tubules couldn't be seen in all groups. In the contact surface between the filled G-P and the canal wall, Lateral condensation showed relatively close sealing, Obtura II and Thermafil had irregular contact surface and Ultrafil showed regular filling pattern. 6. Contact surface between the core of Thermafil and the gutta percha showed close relationship without gap formation.

  • PDF

Vibration Control of Mega Frame Structures using a Semi-active Tuned Mass Damper (준능동 TMD를 이용한 메가골조구조물의 진동제어)

  • Kim, Hyun-Su;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.57-68
    • /
    • 2007
  • The mega frame system is becoming popular for the design and construction of skyscrapers because this system exhibits structural efficiency by allowing high rigidity of the structure while minimizing the amount of structural materials to be used. Since the mega frame system is usually adopted for super high-rise buildings, the comfort of occupants may be main concerns in the practical application of this system. For the enhancement of the serviceability of mega frame structures, a semi-active tuned mass damper (STMD) is developed in this study. To this end, a Magnetorheological (MR) damper is employed replacing passive damper as a semi-active damper to improve the control effect of a conventional TMD. Since a conventional finite element model of mega frame structures has significant numbers of DOFs, numerical simulation for investigation of control performances of a STMD is impossible by using the full-order model. Therefore, a reduced-order system using minimal DOFs, which can accurately represent the dynamic behavior of a mega frame structure, is proposed in this study through the matrix condensation technique To improve the efficiency of the matrix condensation technique, multi-level matrix condensation technique is proposed using the structural characteristics of mega frame structures. The efficiency and accuracy of the reduced-order control proposed in this study and the control performance of a STMD were verified using example structures.

Development of a PM Sampler for Collecting Fine Particles via Condensation Magnification

  • Kim, D.S.;Kang, C.H.;Hong, S.B.;Lee, K.W.;Lee, J.H.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.E1
    • /
    • pp.24-31
    • /
    • 2008
  • In this study, a new PM (particulate matter) sampler was developed and fabricated to collect fine particles in the atmosphere, and laboratory and field tests were carried out to evaluate the performance of the sampler. The PM sampler, which was based on impingers, employed an aerosol condensation system as a PM magnifier to improve its collection efficiencies. Sodium chloride, ammonium sulfate and ammonium nitrate aerosols were used as test particles, because these components are rich in ambient aerosols. As a result, it was found that the collection efficiency of the novel PM sampler was very high. Thus, it is believed that the PM sampler is an effective device for sampling fine particles. In addition, it was demonstrated that this work could contribute to the collection or removal of fine particles and be applied to the semicontinuous sampling of ambient aerosols for chemical composition analysis.

Structural Design Optimization on the Reduced System Constructed from Large-Scaled Problem (축소시스템과 영역분할 기법과의 연동을 통한 대형구조물 설계 기법 연구)

  • Kim, Hyun-Gi;Cho, Maeng-Hyo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.9 s.252
    • /
    • pp.1070-1077
    • /
    • 2006
  • In the present study, sizing and shape optimizations are performed based on the reduced system of large-scaled problem. In the analysis part to achieve efficiency and reliability of computation, two-level condensation scheme is applied. In the construction of reduced system of large scaled problems, it is much more efficient to use sub-domain method. Thus, in the present paper, two-level reduction method combined with sub-domain method is employed. Once the reduced system is constructed, it is straightforward to obtain design sensitivities from the analysis results of the reduced system We use semi-analytic method to obtain design sensitivities. Performance of the efficiency and reliability of the present reduction method in the structural optimization problem is demonstrated through the numerical examples. The present framework of reduction method should serve as a fast and reliable design tool in analysis and design of large-scaled dynamic problems.

Transformation of Dynamic Loads into Equivalent Static Loads by the Selection Scheme of Primary Degrees of Freedom (주자유도 선정 기법에 의한 동하중의 등가 정하중으로의 변환)

  • Kim, Hyun-Gi;Cho, Maeng-Hyo
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1316-1321
    • /
    • 2003
  • The systematic method to construct equivalent static load from the given dynamic load is proposed in the present study. Previously reported works to construct equivalent static load were based on ad hoc methods. They may results in unreliable structural design. The present study proposes a selection scheme of degrees of freedom(d.o.f) for imposing the equivalent static loads. The d.o.fs are selected by Two-level condensation scheme(TLCS). TLCS consists of two two-steps. The first step is the energy estimation in element-level and the second step consists of the traditional sequential elimination precudure. Through several numerical examples, the efficiency and reliability of proposed scheme is verified.

  • PDF

An Experimental Study on Enhancement of the Filter Efficiency by the Image Effect of Charged Particle (대전된 입자의 영상효과에 의한 필터효율 향상에 관한 실험적 연구)

  • Lee, Chang-Sun;Jeong, Hae-Young;Kim, Sang-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.6
    • /
    • pp.760-768
    • /
    • 2000
  • Filter efficiency of electrically charged particle in uncharged fibrous filter was measured. In previous studies, the effect of charged particle on filter efficiency was investigated but there was difficulty in measuring of image effect that is appeared at the charged small particle. We could easily measure the image effect with charging small particles by photoelectric charging. The spark discharge aerosol generator and a differential mobility analyzer (DMA) were used to generate sub-micron monodisperse particles (${\leq}200$ nm). The generated particles were charged in photoelectric charging process using ultraviolet lamp and electric field. The filter efficiency of the charged particles, classified by another DMA, was measured in filter tester using a condensation nucleus counter (CNC) as function of particle diameter, particle charge and airflow velocity. It is shown that the filter efficiency increases with increasing charge number of the particle and is affected by particle size and flow velocity. Single fiber filter efficiency mainly depends on image force parameter and peclet number. The peclet number was not considered at previous other papers. We propose a modi fied experimental correlation as function of image force parameter and peclet number.