• 제목/요약/키워드: Condensate Pump

검색결과 9건 처리시간 0.028초

복합 화력 Condensate Pump 의 고진동 사례 분석 및 대책 (A Case Study on High Vibration in a Condensate Pump for Combined Cycle Power Plants)

  • 최성필;류석주;하현천
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.510-513
    • /
    • 2001
  • Several kinds of vibration problems have been frequently encountered in industrial vertical pumps in spite of their widespread use for long time. In fact, vibration problems of the vertical pumps are so complicated and difficult with compared to those of the horizontally mounted pumps that more careful attention should be taken for solving the vibration problems. This paper introduces a case study experienced from troubleshooting for excessive vibration occurred in a vertical-type condensate pump for combined cycle power plants. Subsynchronous whirl vibration was caused by the instability of the guide bearing whose lubricant is water. A newly modified guide bearing has solved the vibration problem, which should be the best countermeasure.

  • PDF

발전소 복수기 볼세정계통에 의한 입형펌프 진동과 대책 (Vibration Phenomena between Condensate Vertical Pump and Condenser Debris system in Power Plant)

  • 김연환;구재량;배용채;이현;이영신
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1020-1025
    • /
    • 2001
  • Vertical canned pumps are usually applied in the power plant to transport fluids that the available suction pressure is low at the condensate system and the circulating-water system. The top of the motor driver is 5.5m above the base and the barrel and drop column extend even further below the ground. While this size and configuration may produce an efficient pumping system, it also introduces several dynamic problems which must be considered in order to obtain a reliable operation. The main problem is that the vibrational mode of the long flexible cantilever structure above the ground exist near the operational characteristics of the condensate debris system. This system's trouble has been showed at 2,086 hp condensate water loading pumps in a nuclear power plant.

  • PDF

원자력발전소 복수기 수실 차단밸브 설치 영향 평가 (Evaluation the Impact of Installing a Isolation Valve on Condensate System of Nuclear Power Plan)

  • 이선기
    • 산업융합연구
    • /
    • 제18권4호
    • /
    • pp.15-21
    • /
    • 2020
  • 원자력발전소의 순환수 계통 해수배관에 차단밸브가 설치되어 있지 않을 경우 복수기 내부 세관(튜브)에서 해수 누설 등의 이상 발생시, 정비 및 보수를 위해 최소한 순환수 펌프 1대를 정지하여야 하며, 최악의 경우에는 발전정지를 하여야 한다. 그러나 순환수 계통 해수배관에 차단밸브를 설치할 경우, 복수기 이상 발생 시 병열로 연결된 복수기의 해당 수실만 차단 가능함으로 발전소 출력 손실을 최소화 할 수 있다. 본 논문에서는 원자력발전소 순환수 계통의 복수기 수실에 차단밸브를 설치할 경우, 순환수 계통의 유량변화, 계통의 구조적 건전성, 복수기 진공도에의 영향을 평가하였다. 평가결과, 복수기 수실 차단밸브 설치에 따른 유량은 밸브 완전 개방시 0.3% 감소하며, 완전 잠금시에는 4.5% 감소하였다. 또한 유량감소에 따라 복수기 진공도는 떨어지나 계통의 건전성은 유지됨을 알았다.

공진회피에 의한 모터와 펌프의 진동제어 (A Vibration Control of the Motor and the Pump by Avoiding Resonance)

  • 김희원;주원호;정균양
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.148-153
    • /
    • 1998
  • A resonance is the one of major reasons of vibration problems occurred in industrial fields. To reduce vibration level due to resonance, structure reinforcements or change of the dynamic characteristics is generally applied. In this paper, the troublesome vibration levels of the motor shaft and auxiliary condensate pump are reduced by avoiding resonance.

  • PDF

발전소 순환수 및 복수 계통 케이블 건전성 평가 (Cables Condition Assessment for Circulating Water Pump & Condenser Extraction Pump)

  • 하체웅;한성흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.614-615
    • /
    • 2007
  • There are roughly a hundred types of cables in power plants. The distribution of circuits in a nuclear plant is comprised of 20% instrument cables, 61% control cables, 13% AC power cables, 1% DC power cables, and 5% communication lines. In the nuclear power plant, medium voltage cables are generally included in the scope of systems reviewed for safety and are included in a plant's maintenance program. Medium voltage cables provide power to many critical components in plants, including feed water pumps, circulating water pumps, and condensate pumps. Among these cables, high temperature sections of cables feeding electrical power to the circulating water pump and the condenser extraction pump were found. The evaluation for these cables is performed to find the maximum allowable current and temperature. The result shows that the load current flowed about 85% of the allowable current ampacity, and the temperature of conductor at full load current did not exceed the limited temperature. Therefore, existing cables for circulating water pump and condenser extraction pump system are going to be used during design life.

  • PDF

MATLAB/Simulink를 이용한 화력발전소 복수펌프 순환기동로직 시뮬레이션 구현 (Simulation Implementation of Fossil Power Plant Condensate Pumps' Rotation Operation Logic Using MATLAB/Simulink)

  • 윤창선;홍연찬
    • 한국산학기술학회논문지
    • /
    • 제17권1호
    • /
    • pp.693-699
    • /
    • 2016
  • 기존 국내 외 연구를 통해 개발된 펌프 운전 시뮬레이터는 대부분 동역학적 해석을 목적으로 하거나 운전자 교육용을 목적으로 개발되어 왔다. 그런데 기존 시뮬레이터는 운전자 위주로 구성되어 있어서 로직 설계자나 시운전 참여자들이 다양한 운전조건 또는 로직을 임의로 변경하기에는 적절하지 않다. 더욱이 최근 발전소에서 사용되는 두 개 이상의 복수펌프 운전에 대해 설계자나 운전자가 쉽게 활용할 수 있는 시뮬레이터는 개발되어 있지 않다. 그래서 본 논문에서는 MATLAB Simulink를 사용하여 일반적인 화력발전소에 주로 사용되는 복수펌프 3대에 대한 순환운전 로직에 대해 설계자나 운전원이 쉽게 사용할 수 있도록 시뮬레이션을 할 수 있는 방법을 제안 한다. 이 제안은 MATLAB을 사용할 수 있는 사용자가 발전소 DCS(Distributed Control System) 로직에 주로 사용되는 ANSI/ISA S5.2를 Simulink를 통해 구현할 수 있도록 도움을 준다. 또한 코드에 명시된 로직을 구현하기 위해 블록에 대한 Sub-System을 만들고 이를 시뮬레이터 내에서 적용이 가능한지를 검증한다. 제안된 방법을 이용한 실무 검증 단계에서는 로직 내에서 발생한 기동신호를 구현된 펌프 모델에 적용하여 3대 펌프 순환운전 시 발생할 수 있는 모든 오류 가능성을 제안된 시뮬레이터를 사용하여 설계 단계 및 운전 전에 검증할 수 있음을 실험을 통해 확인하였다.

베어링 재설계에 의한 원전 COP motor의 진동 제어 (Vibration Control of Condensate Motors in Nuclear Powerplant By Bearing Redesign)

  • 임도형;김원현;이종문;이수목
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.264-269
    • /
    • 2008
  • This paper presents the summary of control of abnormal vibration found in the COP motors of a nuclear power plant. All six identical units of COP pump-motor assemblies showed unstable vibration pattern of which one or two showed higher vibration enough to exceed the allowable level from the installation stage. Many trials of test, measurement, overhaul and replacement had been repeated to investigate and solve the problem but only to reach unsatisfactory settlement. Recently several times of site tests are made and followed by significant diagnostic actions in which the authors group participated. It was found that the coupled shafting system of motor and pump is in close resonance with the $1^{st}$ shaft rotating speed. Redesign of topside motor bearing clearance is made to increase bearing stiffness and hence to avoid the resonance which consequently led to reduce the troubled vibration to allowable and stable status.

  • PDF

APR1400 종합진동평가를 위한 배관시스템의 유동유발진동 간이평가 (Screening Method for Flow-induced Vibration of Piping Systems for APR1400 Comprehensive Vibration Assessment Program)

  • 고도영;김동학
    • 한국소음진동공학회논문집
    • /
    • 제25권9호
    • /
    • pp.599-605
    • /
    • 2015
  • U.S. Nuclear Regulatory Commission(NRC), Regulatory Guide(RG) 1.20(Rev.3, 2007년)은 원자로 냉각재계통, 주증기, 주급수 및 복수시스템의 주요 배관 및 기기에 대하여 압력변동 및 진동에 의한 잠재적 유해효과에 대한 평가를 요구한다. 그러나 증기발생기와 연결된 주증기, 주급수 및 복수시스템의 주요 배관 전체에 대하여 상세 해석하는 것은 매우 복잡하여 한계가 있다. 이 논문은 APR1400 원전의 종합진동평가(comprehensive vibration assessment program, CVAP)를 수행하기 위하여 증기발생기에 연결된 2차측 주요 배관의 음향공진과 펌프유발진동을 위한 간이평가 방법에 관한 것이다. 이 논문에서는 이러한 배관시스템의 잠재적 진동 원인이 무엇인지, 음향공진과 펌프유발진동의 가능성을 예방하기 위한 간이평가 방법은 무엇인지를 고찰하고자 한다. 이 논문은 APR1400 원전 증기발생기와 연결된 주증기 및 주급수 배관의 유동유발진동 간이평가를 위해 사용될 것으로 판단된다.

외부 개질형 평판형 고체 산화물 연료전지 시스템 구성법에 따른 효율특성 (A Case Study of Different Configurations for the Performance Analysis of Solid Oxide Fuel Cells with External Reformers)

  • 이강훈;우현탁;이상민;이영덕;강상규;안국영;유상석
    • 대한기계학회논문집B
    • /
    • 제36권3호
    • /
    • pp.343-350
    • /
    • 2012
  • 본 연구에서는 외부 개질기에 열원을 공급하기 위한 시스템 내에 가용한 열에너지의 활용 및 확보에 대한 해석을 위해서 외부 개질기를 연계한 평판형 SOFC 시스템의 해석 모델을 구축하고자 한다. 이러한 해석을 위한 모델 구축을 위해 Matlab simulink$^{(R)}$ 기반의 ThermoLib module을 사용하였으며, 구축된 해석 모델을 통하여 시스템의 성능 향상을 위한 구성 기법에 대해서 연구를 하였다. 시스템 구성 방법은 기존 시스템의 layout을 바꾸기 위해 공기극 출구가스 재순환 및 외부개질기와 촉매연소기를 통합한 개질반응시스템 적용, 개질기에 공급되는 혼합연료의 예열, 연료극 출구가스의 응축을 통한 연료 농도 향상 등을 고려하였다. 시뮬레이션의 해석 결과에서는 SOFC 시스템에 있어서 일반 연소기를 적용한 기준 시스템에 비하여 촉매 연소기를 사용한 시스템의 전기 효율이 12.13% 향상되었으며, 연료극 출구 가스를 응축시켜 버너로 연소시킨 시스템에서는 열효율이 76.12%로 가장 높았다.