• Title/Summary/Keyword: Concurrent validity

Search Result 260, Processing Time 0.019 seconds

A Study on the Validity and Test-retest Reliability of the Measurement of the Head Tilt Angle of the Smart Phone Application 'KPIMT Torticollis Protractor'

  • Seong Hyeok Song;Ji Su Park;Ki Yeon Song;Ki Hyun Baek;Seung Hak Yoo;Ju Sang Kim
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.6
    • /
    • pp.177-184
    • /
    • 2023
  • Purpose: The purpose of this study was to compare the concurrent validity and test-retest reliability of 'KPIMT Torticollis Protractor', a smart phone and I-pad application for convenient range of motion measurement, and 'Image J', an analysis software with high reliability and validity, according to head tilt and active cervical rotation angle. This was done to determine the clinical utility of 'KPIMT Torticollis Protractor'. Methods: Head tilt and active cervical spine rotation angles of 40 children with congenital muscular torticollis were measured using Image J and KPIMT Torticollis Protractor, respectively. The level of concurrent validity and inter-rater and intra-rater reliability between the two measurement methods were analyzed. Results: For forty participants, the concurrent validity between Image J and KPIMT Torticollis Protractor showed very high validity with ICC of ICC 0.977 (0.995-0.999), 0.994 (0.994-0.998), CVME% 0.71-0.72%, SEM% 0.31-0.34%, MDC% 0.86-0.94%. The test-retest intra-rater reliability showed very high reliability ICC 0.911 (0.911-0.966), CVME% 0.71%, SEM% 0.34-0.36%, MDC% 0.81-0.94%. The test-retest inter-rater showed very high reliability ICC 0.936 (0.933-0.957), CVME% 0.70%, SEM% 0.34-0.35%, MDC% 0.81-0.83%. Conclusion: The KPIMT Torticollis Protractor, a smart phone and IPD application, is a highly reliable and valid device for angle measurement in children with congenital myotonia and can be easily used in clinical practice.

Exploring Concurrent Validity and Item Level Analysis for Two Korean Versions of Health-Related Quality of Life Instrument: EQ-5D vs. WHOQOL-BREF

  • Choi, Bongsam
    • Physical Therapy Korea
    • /
    • v.27 no.4
    • /
    • pp.233-240
    • /
    • 2020
  • Background: Cross-culturally adapted questionnaires may not be comparable to their original version. Objects: To examine concurrent validity of two health-related quality of life (HRQOL) instruments for the Korean versions of EuroQOL-5 Dimension (EQ-5D) and the abbreviated version of the World Health Organization Quality of Life (WHOQOL-BREF) instrument. Methods: A total of 139 cancer survivors from two rehabilitation institutes was recruited. All participants were registered for palliative rehabilitation care. Both instruments were concurrently administered by health care providers following the second bout of the rehabilitation cares. Rasch partial credit model and Spearman's correlation analysis were used to investigate: 1) dimensionality, 2) hierarchical item difficulty, and 3) concurrent validity using correlations between two instruments. Results: For the WHOQOL-BREF, all items except negative feeling, pain, dependence of medical aid, were found to be acceptable, while all items of EQ-5D were acceptable. There was an evidence of negative correlations between EQ-5D and 4 domains of WHOQOL-BREF. Two correlations were strong (EQ-5D vs. physical health domain, ρ = -0.610, 95% CI = -0.716 to -0.475) and moderate (EQ-5D vs. psychosocial domain, ρ = -0.402, 95% CI = -0.546 to -0.236). Other two correlations were weak (EQ-5D vs. social relationship and environmental domains, ρ = -0.242, 95% CI = -0.401 to -0.075 and ρ = -0.364, 95% CI = -0.514 to -0.207, respectively). Item difficulty calibrations of the two measurements were ranged from -0.84 to 0.86 for the EQ-5D and -1.07 to 1.06 for the WHOQOL-BREF. Conclusion: The study provides some supports for the concurrent validity of the two Korean versions of HRQOL instrument, with evidences of weak to strong correlations between the EQ-5D and four domains of the WHOQOL-BREF applied to various cancer survivors. Additionally, the cancer survivors appeared to have more of a tendency to view the EQ-5D items as being slightly more challenging than the WHOQOL-BREF items.

Reliability of joint angle during sit-to-stand movements in persons with stroke using portable gait analysis system based wearable sensors

  • An, Jung-Ae;Lee, Byoung-Hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.3
    • /
    • pp.146-151
    • /
    • 2019
  • Objective: The purpose of this study was to investigate the test-retest reliability and concurrent validity of the joint angle of the lower extremities during sit-to-stand movements with wearable sensors based on a portable gait analysis system (PGAS), and the results were compared with a analysis system (MAS) to predict the clinical potential of it. Design: Cross-sectional study. Methods: Sixteen persons with stroke (9 males, 7 females) participated in this study. All subjects had the MAS and designed PGS applied simultaneously and eight sensor units of designed PGAS were placed in a position to avoid overlap with the reflexive markers from MAS. The initial position of the subjects was 90º of hip, knee, and ankle joint flexion while sitting on a chair that was armless and backless. The height of the chair was adjusted to each individual. After each trial, the test administrator checked the quality of data from both systems that measured sit-to-stand for test-retest reliability and concurrent validity. Results: As a result, wearable sensor based designed PGAS and MAS demonstrated reasonable test-retest reliability for the assessment of joint angle in the lower extremities during sit-to-stand performance. The intra-class correlation coefficients (ICCs) for wearable sensor based designed PGAS showed an acceptable test-retest reliability, with ICCs ranging from 0.759 to 0.959. In contrast, the MAS showed good to excellent test-retest reliability, with ICCS ranging from 0.811 to 0.950. In concurrent validity, a significant positive relationship was observed between PGAS and MAS for variation of joint angle during sit-to-stand movements (p<0.01). A moderate to high relationship was found in the affected hip (r=0.665), unaffected hip (r=0.767), affected knee (r=0.876), unaffected knee (r=0.886), affected ankle (r=0.943) and unaffected ankle (r=0.823) respectively. Conclusions: The results of this study indicated that wearable sensor based designed PGAS showed acceptable test-retest reliability and concurrent validity in persons with stroke for sit-to-stand movements and wearable sensors based on developed PGAS may be a useful tool for clinical assessment of functional movement.

Validation Study of Korean Version of the Rothbart's Children's Behavior Questionnaire (한국판 Rothbart 유아용 기질 척도(Children's Behavior Questionnaire)의 타당화)

  • Lim, Ji-Young;Bae, Yun-Jin
    • Korean Journal of Human Ecology
    • /
    • v.24 no.4
    • /
    • pp.477-497
    • /
    • 2015
  • The purpose of this study was to examine the psychometric property of the Children's Behavior Questionnaire(CBQ), including reliability, content validity, construct validity, cross validity, and concurrent validity with EAS(Emotionality, Activity, Sociability) scale. The CBQ is a caregiver report measure designed to provide a detailed assessment of temperament in children 3 to 7 years of age. In this study, two groups of participants were included to check cross validity. The first group of participants were 108 preschoolers, 3 to 7 years of age attending kindergartens or child care centers, and their mothers. The second group of participants were 168 preschoolers and their mothers. The CBQ subscales demonstrate adequate internal consistencies. Also, exploratory and confirmatory factor analyses of the CBQ scale reliably recover a three-factor solution indicating three broad dimension of temperament: extraversion/surgency, negative affectivity, and effortful control. Evidence for concurrent validity derives from results of correlation analysis with EAS scale.

Validity and Reliability of the Self-Reflection and Insight Scale for Korean Nursing Students (간호대학생의 자기-성찰 및 통찰력 측정도구 타당도 및 신뢰도 검증)

  • Song, Mi Ok;Kim, Heeyoung
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.25 no.1
    • /
    • pp.11-21
    • /
    • 2018
  • Purpose: The purpose of this study was to translate the Self-Reflection and Insight Scale (SRIS) into Korean and test its validity and reliability. Methods: Participants were 340 nursing students who were recruited from 5 nursing colleges in Korea. Data were collected from November 21 to December 20, 2016 and analyzed using the IBM Statistics SPSS 22.0 and AMOS 23.0 programs. Exploratory factor analysis, Confirmatory factor analysis, and concurrent validity analysis were performed. Results: For the Korean-SRIS (K-SRIS) 4 items were deleted from the original SRIS. The final scale consisted of 16 items which were sorted into- the 2 factors: self-reflection (11 items), insight (5 items). The cumulative percent of variance was 50.91%. The statistically significant correlation between K-SRIS scores and the Reflection in Learning Scale (RLS) support the concurrent validity of the K-SRIS. The reliability of the scale, Cronbach's ${\alpha}$ was .83. Conclusion: The finding indicate that the K-SRIS has validity and reliability. Therefore it can be used for measuring and developing reflection ability in nursing students.

A Preliminary Study on the Test of Oral Reading and Comprehension Skill for Lower Level Elementary School Children (구어적 읽기 이해력 검사의 타당화를 위한 예비연구 : 초등학교 저학년을 중심으로)

  • Park, Chan-Hwa;Kim, Myung-Soon
    • Korean Journal of Child Studies
    • /
    • v.30 no.1
    • /
    • pp.59-75
    • /
    • 2009
  • The purpose of this study was to verify the validity and reliability for the Test of Oral Reading and Comprehension Skill (Gardner, 2000) for Korean lower level elementary school children. Subjects were 122 first to third grade students, tested individually. The vocabulary and comprehension sub-tests of K-WISC III and the reading comprehension test of Basic Academic Skills Assessment (Kim, 2000) were used to verify concurrent validity. Internal reliability was determined by internal consistency coefficients. Results verified concurrent validity. Test scores differed significantly by grade level. Test reliability was also confirmed. In conclusion, the Oral Reading and Comprehension Skill Test (Gardner, 2000) is reliable and valid for examination of reading comprehension skills for Korean lower level elementary school children.

  • PDF

A Pilot Study for Standardization of the Sensory Processing Scale for Children (SPS-C) (아동감각처리척도(Sensory Processing Scale for Children; SPS-C)의 표준화를 위한 예비연구)

  • Shin, Ji-eun;Kim, Kyeong-Mi;Chang, Moon-Young;Hong, Eunkyoung
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.18 no.2
    • /
    • pp.42-54
    • /
    • 2020
  • Objective : The purpose of this study was to define a standard score of Sensory Processing Scale for Children (SPS-C) and its concurrent validity by correlation with the Short Sensory Profile (SSP). Methods : The subjects were children enrolled in nurseries and kindergartens in Busan and Gyeongnam. We defined the standard score of the SPS-C and identified its concurrent validity for 337 children. Both the SPS-C and SSP instruments were used to assess the children's sensory processing ability. The collected data were analyzed using SPSS 24.0. A statistical analysis was used to define the standard score for SPS-C based on the mean and SDs of -1 and -2. To identify the concurrent validity of the SPS-C, the correlation between it and SSP was measured using Pearson's correlation analysis. Results : The ranges of total standard scores on the SPS-C were classified as follows: 115~160 indicated "Typical Performance"; 105~114 indicated "Probable Difference"; and finally, 50~104 indicated "Definite Difference." Concurrent validity was ascertained using the Pearson correlation between the total scores of the SPS-C and the SSP; the Pearson correlation coefficient was .755, indicating a statistically significant correlation. Conclusion : This study suggests the standard score of the SPS-C for interpreting results in clinical settings and confirms that it is a valid tool for evaluating children's sensory processing ability.

The Reliability and Validity of Figure-of-8 Walk Test in Patients with Stroke (뇌졸중 환자에서 Figure-of-8 walk test의 신뢰도와 타당도)

  • Kim, Yang-Ho;Lim, Jae-Heon
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2012
  • Purpose : The purpose of this study was to establish intra-rater, inter-rater, test-retest reliability, and concurrent validity of figure-of-8 walk test in people with stroke. Methods : The subjects of this study were 17 patients who were diagnosed with a stroke. Subjects were tested twice by the same raters, with 1 day between tests. Subjects were assessed by two physical therapists. Test-retest reliability was calculated using intraclass correlation coefficients (ICC). The concurrent validity was demonstrated by spearman correlation of F8WT with 10m walking test (10MWT), timed up and go test (TUG), Berg balance scale (BBS), dynamic gait index (DGI) and four square step test (FSST). Results : Intra-rater, inter-rater, test- retest of F8WT time, showed high reliability. Intra-rater, inter-rater, test-retest of F8WT steps demonstrated high reliability. Intra-rater, inter-rater, test-retest of F8WT total smoothness score showed below moderate reliability. There was a significant positive correlation of F8WT time with 10MWT, TUG, FSST. There was a significant negative correlation of F8WT time with DGI, BBS. There was a significant positive correlation of F8WT steps with 10MWT, TUG, FSST. There was a significant negative correlation of F8WT steps with DGI. There was a significant positive correlation of F8WT test total smoothness score with BBS. Conclusion : The time, and number of steps in F8WT show high inter, intra-rater, test-retest reliability. The F8WT smoothness shows below moderate reliability. The F8WT shows high concurrent validity with other comparable balance, and walking tests. The F8WT is a valid and reliable measure for assessing walking function in patients with a stroke.

Concurrent Validity and Test-retest Reliability of the Core Stability Test Using Ultrasound Imaging and Electromyography Measurements

  • Yoo, Seungju;Lee, Nam-Gi;Park, Chanhee;You, Joshua (Sung) Hyun
    • Physical Therapy Korea
    • /
    • v.28 no.3
    • /
    • pp.186-193
    • /
    • 2021
  • Background: While the formal test has been used to provide a quantitative measurement of core stability, studies have reported inconsistent results regarding its test-retest and intraobserver reliabilities. Furthermore, the validity of the formal test has never been established. Objects: This study aimed to establish the concurrent validity and test-retest reliability of the formal test. Methods: Twenty-two young adults with and without core instability (23.1 ± 2.0 years) were recruited. Concurrent validity was determined by comparing the muscle thickness changes of the external oblique, internal oblique, and transverse abdominal muscle to changes in core stability pressure during the formal test using ultrasound (US) imaging and pressure biofeedback, respectively. For the test-retest reliability, muscle thickness and pressure changes were repeatedly measured approximately 24 hours apart. Electromyography (EMG) was used to monitor trunk muscle activity during the formal test. Results: The Pearson's correlation analysis showed an excellent correlation between transverse abdominal thickness and pressure biofeedback unit (PBU) pressure as well as internal oblique thickness and PBU pressure, ranging from r = 0.856-0.980, p < 0.05. The test-retest reliability was good, intraclass correlation coefficient (ICC1,2) = 0.876 for the core stability pressure measure and ICC1,2 = 0.939 to 0.989 for the abdominal muscle thickness measure. Conclusion: Our results provide clinical evidence that the formal test is valid and reliable, when concurrently incorporated into EMG and US measurements.

Preceding Research on Comparative Analysis of the Validity of Game based Cognitive Training Program for Children with Intellectual Disabilities (지적장애 아동을 위한 게임형 인지훈련 프로그램의 타당도 선행 연구 비교 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.11
    • /
    • pp.161-168
    • /
    • 2021
  • Recently, many cognitive training programs based on digital contents have been presented, but few digital contents have been produced for children with intellectual disabilities among children with developmental disabilities. Digital contents based training programs are needed to apply remotely untact training programs rather than face-to-face apprenticeship classes for improving the cognition of children with intellectual disabilities. This study was attempted to present the new cognitive training program by analyzing concurrent validity, which was analyzed by the correlation between items by comparing with subtests of K-WISC-IV and items of game based Neuro-World cognitive training program. It was found that there are some validity by analyzing correlation between the subtests of K-WISC-IV and the items of Neuro-World program, which means that it has concurrent validity of some items of Neuro-World program. In terms of reliability, the Cronbach alpha value was 0.794, indicating that game performance of children with intellectual disabilities and the degree of level increase in each game were somewhat reliable. This is considered to be a significant result in future studies for clinical trials of cognitive training tools.