• 제목/요약/키워드: Concrete face slab

검색결과 51건 처리시간 0.027초

수위 상승에 따른 CFRD(콘크리트 표면차수벽형 석괴댐)의 거동 모사 원심모형시험 (Centrifuge tests for simulating the behavior of CFRD with increasing water level)

  • 서민우;임은상;김용성;하익수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.784-793
    • /
    • 2006
  • As the number of CFRD constructions increases, the necessity of an accurate assessment on its behavior also has been increasing accordingly. The performance of concrete faced rockfill dam (CFRD) under different water levels is greatly concerned by dam engineers and designers in the world. However, domestic research on CFRD design and construction has yet been insignificant. This study deals with three centrifuge model tests, mainly investigates the deformation of the concrete faced slabs with different face slab stiffness under different water levels. The prototype of a centrifugal model dam is half size of domestic CFRD dam. Detailed material preparation, model design, model set-up, model instrumentation and testing procedures are presented. In order to simulate the prototype concrete faced slab, three kinds of thin fiberglass plates with different thickness was adopted in the three model tests. The water level control facility was specially designed for this experiment to control the water level rise and drawdown during centrifuge flight. Although most of the results from the three model tests are satisfactory, it is also required that the centrifuge test results should be compared with those of numerical analysis and field measurements to analyze the centrifuge test results more in detail.

  • PDF

차수벽에 균열이 발생한 표면차수벽형사력댐의 침투거동 연구 (Study on Seepage Behavior of Concrete Faced Gravel-Fill Dam with Cracked Face Slab)

  • 조성은;박한규;임은상;김기영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.866-873
    • /
    • 2009
  • CFRD (Concrete Faced Rockfill Dam) has been world-widely constructed due to a lot of advantages compared with rockfill dam and recently, sand/gravel materials, instead of crushed rock materials, are also utilized as a main rockfill material to overcome geological and environmental problems. In this paper, the process of water infiltration into the originally unsaturated sand/gravel-fill dam is studied using two-dimensional saturated-unsaturated seepage theory. According to the results of seepage analysis, if the effective drainage zone is installed in the dam, the reservoir water infiltrate into the dam along a downward flow path towards the lower drainage area. The main body constructed with sand/gravel materials, therefore, remains unsaturated.

  • PDF

콘크리트 표면차수벽형 석괴댐 지지층의 토질특성 (Soil Properties of Bedding Bone for Concrete Faced Rockfill Dam)

  • 배종순;성영두
    • 한국지반공학회지:지반
    • /
    • 제12권1호
    • /
    • pp.47-62
    • /
    • 1996
  • The bedding zone which influence directly to the safety of dam is supporting the face slab under hydraulic load in concrete faced rockfill dam. In case that leakage is developed due to various ruptured joint or cracks of face slab and etc., the bedding zone should limit the leakage by low permeability and keep the internal stability. In this study for the proper coefficient of permeability various properties, such as gradation, dry density, performance of embankment work and etc. were analysed. The results from the large scale test of permeability and density are summerized as follows : 1. Coefficient of permeability is decreased clearly by increase of dry density. 2. The particles smaller than the No.4 strive( p,) greatly influences the permeability under dry density of 2.24t 1 m3. 3. In case of C.40 and p,40%, even if dry density decreased to 2.0t/m3, the permeability coefficient is assumed to u x1-scm/s and internal stability is abtained. 4. Generally in dam construction since dry density and uniformity coefficient of bedding zone were higher than 2.2t/m3 and 50 respectively p, of 30~40% is assumed to be suitable and permeability coefficient of below 1$\times$10-3cm l s is expectable.

  • PDF

CFRD Bedding Zone의 축조재료에 대한 투수성 평가 (Evaluation of Permeability on Construction Material in CFRD Bedding Zone)

  • 한상현;여규권
    • 지질공학
    • /
    • 제19권4호
    • /
    • pp.493-499
    • /
    • 2009
  • 우리나라는 암석자원이 풍부하기 때문에 콘크리트표면 차수벽형 석괴댐(CFRD)의 시공이 증가하고 있는 실정이다. 콘크리트표면 차수벽형 석괴댐에서의 표층부 기초지반인 Bedding Zone 구간은 콘크리트 차수벽을 균등하게 지지할 수 있는 지지력과 콘크리트 차수벽의 누수시 세립토의 유실을 억제할 수 있는 차수성을 유지하여야 한다. 따라서 Bedding Zone 구간의 차수성 확보 여부가 댐의 안정성을 좌우하는 주요 요인이 될 수 있다. 본 연구에서는 기존의 시방서에 제시된 Zone-1 구간의 설계입도분포를 만족하는 시험재료를 선정한 후, 차수성을 평가하기 위하여 실내시험을 실시하였다. 시험 분석 결과 투수계수, 건조단위중량 및 흙의 입도분포에 따른 차수효과의 상관관계를 제시하였다. 특히, 투수계수와 건조단위중량의 상관관계, No. 4체 중량통과백분율과 투수계수 관계가 제시되었고, 또한 시간경과에 따른 투수계수의 변화도 제시되었다.

Finite element study on composite slab-beam systems under various fire exposures

  • Cirpici, Burak K.;Orhan, Suleyman N.;Kotan, Turkay
    • Steel and Composite Structures
    • /
    • 제37권5호
    • /
    • pp.589-603
    • /
    • 2020
  • This paper presents an investigation of the thermal performance of composite floor slabs with profiled steel decking exposed to fire effects from floor. A detailed finite-element model has been developed by representing the concrete slab with steel decking under of it and steel beam both steel parts protected by intumescent coating. Although this type of floor systems offers a better fire resistance, passive fire protection materials should be applied when a higher fire resistance is desired. Moreover, fire exposed side is so crucial for composite slab systems as the total fire behaviour of the floor system changes dramatically. When the fire attack from steel parts, the temperature rises rapidly resulting in a sudden decrease on the strength of the beam and decking. Herein this paper, the fire attack side is assumed from the face of the concrete floor (top of the concrete assembly). Therefore, the heat is transferred through concrete to the steel decking and reaching finally to the steel beam both protected by intumescent coating. In this work, the numerical model has been established to predict the heat transfer performance including material properties such as thermal conductivity, specific heat and dry film thickness of intumescent coating. The developed numerical model has been divided into different layers to understand the sensitivity of steel temperature to the number of layers of intumescent coating. Results show that the protected composite floors offer a higher fire resistance as the temperature of the steel section remains below 60℃ even after 60-minute Standard (ISO) fire and Fast fire exposure. Obtaining lower temperatures in steel due to the great fire performance of the concrete itself results in lesser reductions of strength and stiffness hence, lesser deflections.

표면차수벽 석괴댐의 물리탐사 경향 분석 (Aanalysis of Geophysical exploration tendency of C.F.R.D)

  • 김재홍;신동훈;임은상
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.871-876
    • /
    • 2010
  • When surface Concrete Face Rock fill Dam constructs than existent center core type rock fill dam, it is much prevalent form in domestic these day by quality control of that is profitable and weather condition etc. of coreZone. C.F.R.D is less research about seismic survey(Refractional Seismic Prospectin, Resistivity Prospecting) of levee body than fill dam. Thus as C.F.R.D seismic survey is less, safety of that consist is short most development flue is high reason. That is not checking target of minuteness safety diagnosis and so on by short operation period. Wish to analyze inquiry incidental and difference with center core type dam and acquire C.F.R.D preservation administration upper necessary inquiry condition forward hereafter.

  • PDF

Effect of rebar spacing on the behavior of concrete slabs under projectile impact

  • Abbas, Husain;Siddiqui, Nadeem A.;Almusallam, Tarek H.;Abadel, Aref A.;Elsanadedy, Hussein;Al-Salloum, Yousef A.
    • Structural Engineering and Mechanics
    • /
    • 제77권3호
    • /
    • pp.329-342
    • /
    • 2021
  • In this paper, the effect of different steel bar configurations on the quasi-static punching and impact response of concrete slabs was studied. A total of forty RC square slab specimens were cast in two groups of concrete strengths of 40 and 63 MPa. In each group of twenty specimens, ten specimens were reinforced at the back face (singly reinforced), and the remaining specimens were reinforced on both faces of the slab (doubly reinforced). Two rebar spacing of 25 and 100 mm, with constant reinforcement ratio and effective depth, were used in both singly and doubly reinforced slab specimens. The specimens were tested against the normal impact of cylindrical projectiles of hemispherical nose shape. Slabs were also quasi-statically tested in punching using the same projectile, which was employed for the impact testing. The experimental response illustrates that 25 mm spaced rebars are effective in (i) decreasing the local damage and overall penetration depth, (ii) increasing the absorption of impact energy, and (iii) enhancing the ballistic limit of RC slabs. The ballistic limit was predicted using the quasi-static punching test results of slab specimens showing a strong correlation between the dynamic perforation energy and the energy required for quasi-static perforation of slabs.

수위변화에 따른 CFRD의 변형거동 사례분석 (A Case Study on Deformation Behaviors of CFRD with Water Level Change)

  • 윤중만;여규권;김홍연;이재연
    • 한국지반신소재학회논문집
    • /
    • 제17권1호
    • /
    • pp.21-31
    • /
    • 2018
  • 본 연구에서는 시공이 완료된 CFRD에 대하여 담수시점부터 수위변화에 따른 댐 제체의 변형거동을 파악하기 위하여 현장 모니터링을 통하여 댐의 변위를 분석하고, 이를 수치해석 결과와 비교하였다. 담수에 따른 댐 정상 및 하류사면 제체의 거동을 계측한 결과, 축방향 수평변위, 상 하류측 수평변위, 침하가 대부분 초기 담수로부터 저수위가 댐 높이 절반 정도에 이를 때부터 발생하였다. 그 후 저수위 최고 상승시까지 변위가 진행된 후 수위에 관계없이 일정하게 수렴되는 양상을 보였다. CFRD에서 가장 중요한 역할을 하는 차수벽의 수평변위는 모든 지점에서 비슷한 양상을 보였다. 차수벽의 수평변위는 담수 전 외부온도의 영향으로 동절기에 증가하고 하절기에 감소하는 경향이 있었다. 또한, 담수 후 저수위가 댐 높이 절반 정도에 이를 때까지 변위가 증가한 후 수위상승과 함께 감소하는 경향을 보였다. 결과적으로 차수벽의 거동은 저수위 조건뿐 아니라 담수 후에도 계절적인 변화를 나타내며, 콘크리트 슬래브의 재료적인 특성 영향이 큰 것으로 판단된다. 수치해석 결과 댐 축조 후 최대 침하량과 발생 위치는 실제와 다소의 차이가 있었는데, 이러한 차이는 해석시 입력 매개변수의 추정, 축조일수 및 층 시공두께 등 다양한 설계와 시공의 차이에서 기인한 것으로 판단된다. 그리고 전반적인 기간에 대하여 침하는 댐 축조기간 동안 대부분 완료되었고 담수 초기에 약간의 침하가 발생한 후 수렴되었다.

내민길이를 고려한 $700kg/cm^2$ 고강도 콘크리트 골조의 구조적거동 (The Structural Behavior of $700kg/cm^2$ High Strength Concrete Frames Considering Extension Distances at Joints)

  • 신성우;안종문;윤영수;이승훈
    • 콘크리트학회지
    • /
    • 제6권5호
    • /
    • pp.140-148
    • /
    • 1994
  • R/C 라멘골조에 있어서 수직부재(기둥, 벽등)에 수평부재(보, 슬라브등)의 콘크리트 강도보다 1.4배가 넘는 강도의 콘크리트를 분리타설할 경우 ACI 318R-89 R10.13.1은 수직부재에 타설한 콘크리트가 수평부재로 2ft(60cm)이상의 내민길이를 확보하도록 규정하고 있다. 이에 따라 본 연구는 이규정을 그대로 적용하기에 앞서 실험적인 검증을 통한 구조적인 안전성을 확보하기 위하여 고강도 콘크리트 내민길이, 콘크리트 압축강도 등을 주요변수로 하여 총 6개의 실험체를 제작하여 실험 및 분석하였다. 실험결과 압축강도 및 내민 길이의 증가에 따라 각 실험체의 연성능력은 증가하는 것으로 나타났으며 R/C 라멘골조에 고강도 콘크리트와 보통강도 콘크리트를 분리타설할 경우 균열발생상황, 접합부에서의 거동 등을 고려할 때 고강도 콘크리트의 내민길이는 2h(h=보의 전체춤) 정도를 확보하여야 할 것으로 보여진다.

강연선과 폴리머 모르타르에 의해 보수보강된 슬래브의 휨거동에 대한 실험적 고찰 (An Experimental Study on the Flexural Behavior of Slab Repaired and Reinforced with Strand and Polymer Mortar)

  • 양동석;황정호;박선규
    • 콘크리트학회논문집
    • /
    • 제17권2호
    • /
    • pp.171-177
    • /
    • 2005
  • 철근콘크리트 구조물은 시간이 경과함에 따라 외력의 증가나 환경의 변화 등에 의하여 노후화되고 그 기능을 상실하게 된다. 이러한 구조물의 기능을 회복하기 위하여 보수$\cdot$보강 공법이 적용되고 있다. 본 연구에서는 이러한 보수$\cdot$보강 공법 중프리스트레싱 공법과 단면증설 공법의 특성을 도입한 강연선과 폴리머 모르타르에 의한 보수$\cdot$보강 공법이 적용된 슬래브의 휨 거동특성을 통해 기존 구조물의 보수$\cdot$보강 효과를 파악하였다. 실험은 강연선의 직경, 모르타르의 종류, 치핑 여부, 모르타르 두께, 강연선의 간격 등의 실험변수에 따라 1방향 슬래브 10개, 2방향 슬래브 4개의 시험체를 제작하여 수행하였다. 실험결과 강연선의 간격이 감소할수록 보강효과가 증가하였고, 치핑을 한 경우 콘크리트와 모르타르의 계면에서의 균열이 극한하중 이후에서 발생하였다.