Geophysical and mechanical investigation of different environmental effects on a red-bed soft rock dam foundation

  • Liming Zhou;Yujie Li;Fagang Wang;Yang Liu
    • Geomechanics and Engineering
    • /
    • v.34 no.2
    • /
    • pp.139-154
    • /
    • 2023
  • Red-bed soft rock is a common stratum and it is necessary to evaluate the mechanical properties and bearing capacity of red-bed soft rock mass affected by different environmental effects. This paper presents a complete procedure for evaluating the bearing capacity of red-bed soft rock by means of geophysical exploration and in-situ rock mechanics tests. Firstly, the thickness of surface loosened rock mass of red-bed soft rock was determined using geophysical prospecting method. Then, three environmental effects, including natural weathering effect, dry-wet cycling effect and concrete sealing effect, were considered. After each effect lasted for three months, in-situ rock mass mechanical tests were conducted. The test results show that the mechanical properties of rock mass considering the sealing effect of concrete were maintained. After considering the natural weathering effect, the mechanical parameters decrease to a certain extent. After considering the effect of dry-wet cycling, the decreases of mechanical parameters are the most significant. The test results confirm that the red-bed soft rock dam foundation rock mass will be significantly affected by various environmental effects. Therefore, combined with the mechanical test results, some useful implementations are proposed for the construction of a red-bed soft rock dam foundation.

Development of Autoclave Aerated Concrete Using Circulating Fluidized Bed Combustion Ash (순환유동층 보일러애쉬를 활용한 경량기포 콘크리트 개발)

  • Lee, Chang Joon;Song, Jeong-Hyun;Chung, Chul-Woo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.1
    • /
    • pp.58-65
    • /
    • 2021
  • In this study, as a method to increase the recycling of circulating fluidized bed combustion ash(CFBCA), CFBCA was utilized to produce autoclave aerated concrete product since CFBCA contains quicklime and calcium sulfate components that are required for the manufacture of autoclave aerated concrete. Successful achievement of such objective will bring cost reduction with high value addition, saving of natural resources, and the reduction of environmental load. Various mixing designs were designed to evaluate the properties of autoclave aerated concrete made of CFBCA. Based on series of experimental program, prototypes mix design for factory manufacturing was obtained. According to the experimental results, it was confirmed that gypsum can be replaced with CFBCA through the method of pre-treating the CFBCA as a slurry. It was possible to produce competitive autoclave aerated concrete products using CFBCA.

Natural Frequency Analysis of Sleeper Floating Track System using Modal Test Technique (모달시험기법을 이용한 침목플로팅궤도의 고유진동수 분석)

  • Jung-Youl Choi
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.3
    • /
    • pp.833-838
    • /
    • 2024
  • The urban railway sleeper floating track(STEDEF) is a structure that structurally separates the sleepers and the concrete bed using sleeper boots and resilience pads to reduce vibration transmitted to the concrete bed. Recently, the resilience pads of sleeper floating tracks that have been in use for more than 20 years are deteriorating. Accordingly, in order to evaluate the performance of the resilience pad, a static spring stiffness test is being performed after extracting the resilience pad. This evaluation technique is performed after replacing the resilience pad in use. However, the track natural frequency can change depending on the resilience pad spring stiffness and the uplift and subsidence of the concrete bed. In this study, modal testing technique was used to evaluate the track natural frequency. For this purpose, the sleeper boots material, resilience pad spring stiffness, and track natural frequency according to concrete bed uplift and subsidence were measured using modal tests at a laboratory scale. It was analyzed that the natural frequency of the sleeper floating track was directly affected by changes in the spring stiffness of the resilience pad. In addition, the change in natural frequency due to the uplift and subsidence of the concrete bed was also found to be large. Therefore, it is believed that the modal test technique presented in this study can be used to evaluate the resilience pad deterioration and voided sleepers.

Mechanization Scheme for ballast withdrawal from ballast track bed (자갈도상 자갈철거 기계화 방안)

  • Yang, Hoe-Seong;Kong, Sun-Yong;Kong, Bak-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1029-1037
    • /
    • 2008
  • As for track maintenance, Seoul Metro executes track bed improvement project from obsolete ballast track bed to concrete track bed in order to achieve maintenance free and to extend its LCC(Life Cycle Costing). When it comes to obsolete ballast track bed withdrawal task, now it is done solely relying on man power and ballast inhalation vehicle. In this paper, I suggested ballast cleaning system with lighter equipment to change manpower withdrawal tasks to mechanized ones. It is expected to improve work efficiency and economic benefits by applying track excavator having variable wheels and container etc, which is able to keep on the site.

  • PDF

Evaluation of Anti-Stripping Performance in Asphalt Concrete using Byproduct Ash produced from Circulating Fluidized Bed Boiler (보일러 부산 애쉬를 이용한 아스팔트 콘크리트의 박리저항성 평가)

  • Kim, Yooseok;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.2
    • /
    • pp.319-325
    • /
    • 2018
  • Pot-holes are steadily increasing due to abnormal climate such as heavy rainfall and frequent snowfall. Pot-hole related to traffic accidents cause injuries, car damage and distress of road facilities. To reduce pot-holes, the use of an anti-stripping agent is mandatorily recommended to asphalt concrete mixture. Hydrated lime is commonly used as anti-stripping agent due to the convenience and economics. Byproduct ash from circulating fluidized bed boiler was reviewed as an anti stripping agent. According to the test results, the byproduct ash is satisfied with TSR specification using 1% to 3% by weight of the asphalt mixture. The byproduct ash was examined under various condition changes of aggregate and asphalt concrete mixture considering quality movement. According to the results, using the byproduct ash was measured average 0.87 of TSR and coverage rates of 60% after rolling bottle test. Test results also revealed that the byproduct ash showed stable performance. Using the byproduct ash to decrease pot-hole in asphalt concrete pavement is suitable for demonstrating stable performance as anti-stripping agent.

A study on a Integrated analysis for survey of the cavity behind the Concrete (콘크리트 배면 공동탐사를 위한 복합적 해석 연구)

  • Noh, Myung-Gun;Oh, Seok-Hoon;Suh, Baek-Soo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.185-189
    • /
    • 2009
  • Integrated analysis of GPR, impact echo and impulse response for detection of the rear cavity of concrete was performed on the test-bed which was made in the same scale and component ratio to the real concrete structure. GPR survey may roughly delineate the location of the cavity, but applying the IE and IR technique to the test-bed, the location was clearly identified.

  • PDF

Study on the Utilization of Sawdust Bedding Barn for Dairy Cows II. Comparision of utilization efficiency of the different depth of sawdust bedding for dairy cows (착유우의 톱밥발효우사 이용 연구 제2보 :착유우 톱밥발효우사의 톱밥상 처리방법에 따른 이용효과 비교)

  • 권두중;권응기;정석근;한정대;정석찬;강승원;강상열;정형섭;장학주
    • Journal of Animal Environmental Science
    • /
    • v.1 no.2
    • /
    • pp.117-124
    • /
    • 1995
  • This study was carried out to investigate the effect of depth of sawdust bedding and ground material in dairy cattle barn. Treatment included the concrete floor with a 10cm or 30cm sawdust and the earth floor with a 30cm sawdust. Eighteen cows were assigned to 3 pens with 16.5㎥/head bedding area. The results obtained were as follows : 1. The temperature of sawdust bed was highest in the earth floor with 30cm sawdust, and the moisture content of sawdust bed was highest in the concrete floor with 10cm sawdust bed. 2. Cows defecate feces 9.2, 8.7 and 9.3 times a day in 10cm sawdust on concrete floor(10S+C), 30cm sawdust on concrete floor(30S+C) and 30cm sawdust on non concrete floor(30S+ NC) respectively. In average, they excreta 9.1 times/day(85.8%) in the sawdust beds and 1.5 times/day(14.2%) in the feeding alley. 3. The ratio of daily water amount deposited vapor to total water amount deposited in sawdust beds was 74.0%, 61.5% and 47.1% in 10S+C, 30S+C and 30S+NC respectively. 4. N.P.K contents in the sawdust beds were higher for 10S+C compared with other treatments. 5. When 30cm of sawdust was applied on the earth ground NO$_3$-N contents in the sawdust bed was 37.7, 14.1 and 15.0ppm in depth of 30, 60 and 90cm under the ground, respectively, indicating some possibility of water pollution.

  • PDF

A Fundamental Study on Analysis of Electromotive Force and Updating of Vibration Power Generating Model on Subway Through The Bayesian Regression and Correlation Analysis (베이지안 회귀 및 상관분석을 통한 지하철 진동발전 모델의 수정과 기전력 분석)

  • Jo, Byung-Wan;Kim, Young-Seok;Kim, Yun-Sung;Kim, Yun-Gi
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.2
    • /
    • pp.139-146
    • /
    • 2013
  • This study is to update of vibration power generating model and to analyze electromotive force on subway. Analysis of electromotive force using power generation depending on classification of locations which are ballast bed and concrete bed. As the section between Seocho and Bangbae in the line 2 subway was changed from ballast bed to concrete bed, it could be analyzed at same condition, train, section. Induced electromotive force equation by Faraday's law was updated using Bayesian regression and correlation analysis with calculate value and experiment value. Using the updated model, it could get 40mV per one power generation in ballast bed, and it also could get 4mV per one power generation in concrete bed. If the updated model apply to subway or any train, it will be more effective to get electric power. In addition to that, it will be good to reduce greenhouse gas and to build a green traffic network.

Experimental research on vertical mechanical performance of embedded through-penetrating steel-concrete composite joint in high-temperature gas-cooled reactor pebble-bed module

  • Zhang, Peiyao;Guo, Quanquan;Pang, Sen;Sun, Yunlun;Chen, Yan
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.357-373
    • /
    • 2022
  • The high-temperature gas-cooled reactor pebble-bed module project is the first commercial Generation-IV NPP(Nuclear Power Plant) in China. A new joint is used for the vertical support of RPV(Reactor Pressure Vessel). The steel corbel is integrally embedded into the reactor-cabin wall through eight asymmetrically arranged pre-stressed high-strength bolts, achieving the different path transmission of shear force and moment. The vertical monotonic loading test of two specimens is conducted. The results show that the failure mode of the joint is bolt fracture. There is no prominent yield stage in the whole loading process. The stress of bolts is linearly distributed along the height of corbel at initial loading. As the load increases, the height of neutral axis of bolts gradually decreases. The upper and lower edges of the wall opening contact the corbel plate to restrict the rotation of the corbel. During the loading, the pre-stress of some bolts decreases. The increase of the pre-stress strength ratio of bolts has no noticeable effect on the structure stiffness, but it reduces the ultimate bearing capacity of the joint. A simplified calculation model for the elastic stage of the joint is established, and the estimation results are in good agreement with the experimental results.

Shear behaviour of AAC masonry reinforced by incorporating steel wire mesh within the masonry bed and bed-head joint

  • Richard B. Lyngkhoi;Teiborlang Warjri;Comingstarful Marthong
    • Earthquakes and Structures
    • /
    • v.26 no.5
    • /
    • pp.363-382
    • /
    • 2024
  • In India's north-eastern region, low-strength autoclaved aerated concrete (AAC) blocks are widely used for constructing masonry structures, making them susceptible to lateral forces due to their low tensile and shear strengths and brittleness nature. The absence of earthquake-resistant attributes further compromises their resilience during seismic events. An economically viable solution to enhance the structural integrity of these masonry structures involves integrating steel wire mesh within the masonry mortar joints. This study investigates the in-plane shear behaviour of AAC masonry by employing two approaches: incorporating steel wire mesh within the masonry bed joint "BJ" and the masonry bed and head joint "BHJ". These approaches aim to augment strength and ductility, potentially serving as earthquake-resistant attributes in masonry structures. Three distinct variations of steel wire mesh and three reinforcing arrangements, i.e. (-), (L) and (Z) arrangement were employed to reinforce the two approaches. The test result reveals a significant enhancement in structural performance upon inclusion of steel wire mesh in both reinforcing approaches, with the "BHJ" approach outperforming the "BJ" approach and the unreinforced masonry, along with increase in capacity as the wire mesh size increases. Furthermore, the effectiveness of the reinforcing arrangement is ranked with the (Z) arrangement showing the largest performance, followed by the (L) and (-) arrangement.