• Title/Summary/Keyword: Concrete Test

Search Result 8,324, Processing Time 0.033 seconds

Corrosion Prediction of a Cement Mortar-Grouted Rockbolt by Measuring Its Chloride Diffusion Coefficient (시멘트 모르타르계 록볼트 충전재의 염화물 확산계수 측정을 통한 록볼트 부식 예측)

  • Bae, Gyu-Jin;Chang, Soo-Ho;Kim, Dong-Gyou;Park, Hae-Geun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.8 no.3
    • /
    • pp.259-271
    • /
    • 2006
  • This paper aims to predict the corrosion of a fully cement-grouted rockbolt induced by chloride diffusion in a cement mortar grout. From the viewpoint of the long-term durability, a rockbolt may be deteriorated by chemical components, such as sulphate and chloride, in groundwater. Especially, the steel rod of a rockbolt is corroded mainly by chloride. The rockbolt corrosion results in the volume expansion of a rod and then the cracking of a cement grout. In this study, the chloride diffusion coefficient of a cement mortar grout was used to evaluate the possibility of rockbolt corrosion by chloride, and to predict the long-term durability of a rockbolt. The electric acceleration test method was adopted to measure the chloride diffusion coefficient. In addition, a simple pullout testing system was newly proposed to measure the pullout capacity of a rockbolt more easily in a laboratory condition. From the experiments, it was showed that the chloride could diffuse in the cement grout more easily than in ordinary concrete materials. As a result, it was considered that a rockbolt might be easily corroded in a short term by the diffusion of chemical components with high concentration, although it was fully grouted.

A Study on Changes in Indoor Air Pollution by Educational Activities -Centering on Newly-Established Elementary Schools- (교육활동에 따른 실내오염도 변화에 관한 연구 -신설 초등학교를 중심으로-)

  • Jeon, Seok-Jin
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.2
    • /
    • pp.66-90
    • /
    • 2007
  • The purpose of this study is to measure and analyze primary causes of indoor air pollution, including carbon dioxide, minute dust, and total volatile organic compounds, for each room before the beginning of a class through the time of discharge after the end of the class in general classrooms, computer rooms, and science rooms of three newly-established schools that opened in 2006, examine properties of indoor air environment in each room by educational activities at school, and determine effective management schemes; the results of this study can be summarized as follows: 1) As for implications for each item found in the mean for each place, since minute dust (PM10) was more likely to occur in time slots full of students' activities, such as a traveling class and a recess, than in the middle of a class and could be expected fully, it is necessary to make a scheme for cleaning in order to reduce minute dust within a room, for example, by usually using a vacuum cleaner indoors. 2) While carbon dioxide was expected to vary with the differences in the amount of breath between higher-graders and lower-graders in a general classroom but showed insignificant difference by grades, showing differences in pollution by four times at a maximum according to the opening of a window as expected, it is necessary to implement artificial or natural ventilation and take a positive measure, for example, by presenting a concrete ventilation scheme, in order to improve indoor air pollution at a room practice. 3) Total volatile organic compounds were found to exceed the standard by more than twice in general classrooms, science rooms, and computer rooms of the schools because of building materials, furnitures including desks and chairs, panels and boards for environment beautification, and items which could be detected even from students' clothes; while a field directly-reading tool was used, obtaining high reliability for the results, it is necessary to apply an analytical method based on process test separately for actual correct measurement if a significantly great amount of total volatile organic compounds appear as compared with other schools due to measuring expenses and consecutive measurements. 4) Since formaldehyde (HCHO) was generally found to exceed the standard in general classrooms, science rooms, and computer rooms, it is necessary to establish and operate a ventilator during a class in a computer room which requires airtightness and a science room in which an organic compound should be used for a class.

  • PDF

Correlation of Experimental ana Analytical Inelastic Responses of 1:12 Scale Irregular High-Rise RC Buildings (1:12축소 비정형 고층 RC 건물의 비선형거동에 대한 실험과 해석의 상관성)

  • Ko, Dong-Woo;Lee, Han-Seon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.95-104
    • /
    • 2007
  • Three types of high-rise RC building structures having irregularity in the lower two stories were selected as prototypes and were performed nonlinear static analysis by using OpenSees to verify the analysis technique and to investigate the seismic capacity of those buildings. The first one has a symmetrical moment resisting frame (Model 1), the second has an infilled shear wall in the central frame (Model 2), and the third has an infilled shear wall only in one of exterior frames (Model 3). Fiber model, which consists of concrete and reinforcing bar represented from stress-strain relationship, is adapted used for simulate the nonlinearity of members, and MVLEM(Multi vertical linear element model) is used for simulate the behavior of wall. The analytical results are simulate the behavior of piloti stories well, for example, the stiffness and yield farce of piloti stories, the up-lift of wall and the variation of lateral stiffness of column due to the variation of axial forces. Overstrength of Model 2 and Model 3 are about 2 times larger than that of Model 1. The reason of the high oversttrength and ductility of Model 2 and Model 3 is that the conservative design of Model 2 and Model 3, whose beam and column sections are the same as those of Model 1. The ductilities of Model 1 and Model 3 are slightly larger than that of Model 1 and Model 3. Model 1 and Model 3 reached mechanism condition, whereas Model 2 failed to the shear failure of shear wall and the large axial forces in columns due to large overturning moment.

Development of the Automatic Feeder for Growing-finishing Pigs (육성비육돈용 자동급이기 사료공급장치 개발에 관한 연구)

  • Yoo, Y.H.;Song, J.I.;Choi, H.C.;Kim, J.H.;Park, K.H.;Kang, H.S.;Chang, D.I.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.3
    • /
    • pp.241-250
    • /
    • 2009
  • This study was conducted to develop an prototype automatic feeder (AF) for growing-finishing pigs. The main components of AF were a feed storage hopper, a feeding motor, a feed agitator, a control box and a programmable IC, which were controlled by a personal computer. The powder type feed transfer rate of AF was average $9.83{\pm}0.4\;g\;s^{-1}$. In feeding test, growing pigs (Landrace) of about 43 kg live weight were used in the study, and was fed over a 6 weeks in pens with solid concrete floors. For feeding trials with AF, the operation time of the feeding motor was set to 2, 3, 4, 5, and 6 seconds per feeding. Pigs frequently used AF from 05:00 to 11:00 and from 11:00 to 17:00 without relationship to the operation time of the feeding motor. The AF operation time of the feeding motor to minimize feed loss was between 2 and 4 seconds. Pigs fed with AF had same or slightly higher average daily gam (0.8~0.9 kg) than that with a commercial feeder, and average daily feed intake (2.76~2.93 kg) and feed conversion ratio (3.10~3.66) of pigs fed with AF were same or lower than those with the commercial feeder except the operation time of the feeding motor set to 6 seconds. As a result, AF would help to use and improve the productivity of growing-finishing pigs.

  • PDF

A Study on the Removal of Heavy Metals from Groundwater Using Permeable Reactive Barriers Based on Nano FeS (나노 FeS를 이용한 투과성반응벽체의 중금속 오염 지하수 처리에 관한 연구)

  • Jung, Gwan-Ju;Choi, Sang-Il;Lee, Jai-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.6
    • /
    • pp.19-28
    • /
    • 2009
  • The acid mine drainage (AMD) and landfill leachates released into the subsurface environment can result in serious environmental problems like soil and groundwater contamination. The AMD and the leachates of landfill were known to contain many heavy metals. In this study, the author assessed the reactivity and ability of the FeS coated-ALC for the removal of contaminants (As, Cd, Cu, Pb, Ni, Zn, Al) in AMD and leachates in landfill. The synthetic nano-FeS and Autoclaved Lightweight Concrete (ALC) were used as reactive materials in the permeable reactive barriers(PRBs). The result of batch test indicated that synthetic nano-FeS can remove 99% of heavy metals for the 1hr of reaction time except for As and Ni(about 90%). However, the 80% of As and Ni was removed in column 1(FeS coated-ALC). The column 2(Ore FeS) removed more than 99% of heavy metals. The pH of the column 1 was increased from 3.51 to 6.39~6.50, and the pH with column 2 was increased from 3.51 to 9.20. As the result of this study, the author can surmise that the synthetic nano-FeS coated ALC will use as a very good reactive material of the PRBs to treat the contaminated groundwater with AMD and leachate of landfill.

Shear Capacity Evaluation of Steel Plate Anchors Using Folded Steel Plate in AU-composite Beam (절곡 강판을 이용한 AU합성보 덮개형 강재앵커의 전단성능 평가)

  • Lim, Hwan Taek;Choi, Byong Jeong
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.5
    • /
    • pp.389-400
    • /
    • 2017
  • Based on U-shaped composite beam, the new form of AU-composite beam were developed to create economical and efficient components reducing the cost and shortening the length of construction work. Because the U-shaped sections are open and needs to be fixed by topping concrete securely. Therefore, it is required to maintain the U-shaped sections in a structure and to work in the safe condition through construction. It also requires accessories that resist the horizontal shear force for synthesis between the top and bottom of the U-shaped section. To reinforce these shortcomings, a shear connector has been developed with various purposes of steel plate anchors. In this study, the steel plate anchors were directly tested and the shear force was evaluated by the horizontal shear force. The experiment was divided into two types, depending on the applicable deck plates. As a result of the experiment, the continuous type specimens showed greater resistance in both strength and displacement than the ones of stud anchor specimen. In discontinuous type case, due to shear simulations and simple element analysis, the less increase the ratio of width to height and the more shear strength decreased. Thus, the shear strength equation of the stud anchor was modified to suggest the new shear strength based on the testing results.

A Study on the knowledge and attitude of AIDS In college students (일 대학 학생들의 AIDS에 대한 지식, 태도의 관한 연구)

  • Choi, Gil-Soon;Chae, Min-Jeong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.13 no.2
    • /
    • pp.73-86
    • /
    • 2009
  • Purpose : This study is a descriptive correlation study to offer the basic materials for developing the preventive program of continuously increasing AIDS in the young people by examining the knowledge and attitude of AIDS in college students. Methods : The period of data collection was from May 1 to 15, 2009, 300 freshman, sophomore and junior students who understood the purpose of the research and agreed to participate in the questionnaire were randomly sampled, structured questionnaire was distributed to them and their responses were collected. Instruments used for this study included those used by Kim and Lee and revised and complemented by this researcher to measure the knowledge of AIDS and those by Yun and Lee revised and complemented by the researcher to measure the attitude of AIDS. For data analysis, it measured technical statistics, t-test, ANOVA, and Pearson's correlation coefficient using SPSS/PC 12.0. Results : The results of this study are summarized as follows. 1. The whole knowledge of AIDS the subjects had scored 58.9 and their average attitude scored $3.78(1{\pm}25)$. 2. In the degree of knowledge of AIDS depending on general characteristics and health-related characteristics of the subjects, it was found that the students at the department of emergency medical showed higher knowledge(t=3.638, p=.001) and positive attitude of AIDS(t=3.330, p=.001) compared to students at other majors. 3. In the degree of knowledge of AIDS depending on AIDS-related education, subjects who had experienced AIDS education(t=1.973, p=.050), those with the experience of theory education(F=4.057, p=.008), those who felt the necessity of AIDS education(t=4.588, p=.000), and those who were willing to take part in AIDS education(t=2.898, p=.004) showed higher know1edge of AIDS. In the attitude of AIDS, subjects with theory-oriented AIDS education(F=3.012, p=.032), those who felt the necessity of AIDS education(t=2.445, p=.015), and those who were willing to take part in AIDS education(t=2.379, p=.018) showed positive attitude of AIDS education. 4. As the knowledge of AIDS the subjects was higher(r=.329, p=.000), they showed more positive attitude of AIDS and it meant that there was positive correlations. Conclusion : Consequently, systematic, concrete and continuous education of AIDS suitable to the requirements of college students is needed to induce changes of their knowledge and attitude of AIDS and for this, AIDS education program which can be used properly by the developmental stages of college students who belong to late adolescence should be developed in the field of school and if possible, curriculum of sex education including AIDS education should be established in all departments of college.

  • PDF

Hospital Marketing Condition and Strategy -Of a General Hospital- (병원마케팅 실태와 전략방안 -지역사회의 일 종합병원을 대상으로-)

  • Baek, Myung;Ro, So-Young
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.6 no.2
    • /
    • pp.233-246
    • /
    • 2000
  • The purpose of this study was to investigate the real condition of hospital marketing and concrete strategy on medical consumers need for enhance the effectiveness of hospital management. The data were collected from January 27 to February 3, 2000 at a general hospital located in M city to 205 in-patients and out-patients by questionnaires. The research tool was based on literatures. The data was analysed by the use of percentage, mean, t-test and ANOVA by SAS(Statistical Analysis System) Package Program. The results of this study are summerized as follows: 1. Mean score of the marketing mix (4P 's) was 3.1 in total and each mean score was 3.6 in product, 2.5 in prices, 3.3 in place and 3.1 in promotion. The following are the items which received the highest scores in each: 'The hospital is clean' in service category; 'the prices of meals at the restaurant the patients' families use are reasonable ' in price sphere. In distribution, 'it is easy to locate the hospital' and in promotion,'we'll use this hospital again' and 'we'll recommend this hospital to others'. 2. Marketing mix factors(4P's) was significantly different on the general characteristics in terms of marriage status, occupations and the period of hospitalization. 3. The most important reason for choosing this hospital was 'This is a general hospital with good facilities' and the next were 'The hospital staffs are kind and the hospital is clean' and 'The traffic is convenient to come'. The most important factors contributing to a good image formation of the hospital were 'this is a clean hospital', 'This is a hospital with kind people' and 'this hospital is equipped with good medical facilities'. 4. The factors for making a good image concerning the nursing service were professional knowledge, good nursing skills and kindness. After grasping the marketing conditions of the hospital aided by the above-mentioned research results, the researchers concludes that it is necessary to develop an institutionalized service strategy to increase the satisfaction the patients feel about the hospital facilities and kindness of the staff and as a result, to differentiate it from other medical institutions.

  • PDF

Comparision Between Noise Levels of Hospital Wards and the Nurses Efforts for Noise Management in Selected General Hospital (종합병원 병동별 간호사실의 소음정도와 간호사실들의 소음인지도 및 소음관리노력 비교)

  • Jung, Hyun-Wook
    • Korean Journal of Occupational Health Nursing
    • /
    • v.10 no.2
    • /
    • pp.174-182
    • /
    • 2001
  • This study was performed to find out the differences between noise levels of hospital wards and the nurses efforts for noise management in some general hospitals. The hospital wards selected were the intensive care unit(ICU), the emergency room(ER), the nursery room(NR), the internal medicine(IM), the general surgery(GS) among the 5 general hospitals located in Seoul. The data were collected from August 3 to September 13, 1999 through questionnaire survey and noise measurement in each nursing station of hospital wards. Data analysis was done by SPSS 8.0 package among the 305 questionnaires and 24 hours monitored noise levels. Frequency, Chi-square and ANOVA test were used. The study results were as belows: 1. The noise level measured by 24 hours monitoring survey were exceeded on the standard limit in all the hospital wards. Data also showed that noise levels were significantly different in each ward among the three shifts working duties. 2. The subjects were all female nurses. They were mostly working in the ICU ward(28.9%). They were 26~30 years old (43.9%), junior college graduates(57.0%), working for 1~5 years(55.1%) as staff-nurse(85.6%). There were no significant differences between hospital wards and general characteristics of nurses. 3. The noise levels perceived by nurses were regarded as 'Highly noisy'(56.4%), especially during the 11:30 and 15:30 (30.2%) o'clock. Data also showed that noise education was not ever given to nurses(89.9%). Nurses also responded that they hardly put an effort to reduce noise level(54.8%). However, there were significant differences between wards and noisy working time, experience of noise education and level of effort for noise reduction. 4. Nurses also perceived the ventilator alarm and EKG-alarm as the most disturbing sounds in the ICU, human voice and telephone ringing in the ER, human voice and EKG-alarming in the NR, human voices and telephone ringing in IM and GS both wards respectively in order. There were significant differences between hospital wards and noise making factors. 5. Nurses were shown that they regarded highly 'Sound reduction of the human voice', 'Careful handling on medical instruments', and 'Immediate appliances on alarming materials' as the practical method for noise management. There were significant differences between hospital wards and behavioral practical efforts for noise management. According to that results, the statistical differences were shown in the 24 hour monitored noise levels in each ward. Also, nurses perceived the noise severity differently and they approached variously on the practical efforts for noise reduction in each ward. Thus, author thinks that concrete and systematic endeavor will be necessary for noise reduction and management in hospitals for better working and healing environment for both of patients and staffs.

  • PDF

Experimental Study on Evaluation of Rotational Resistance of Multi-Span Greenhouse Foundations (연동비닐하우스 기초의 회전저항성능 평가에 관한 실험적 연구)

  • Lee, Hyunjee;Shin, Jiuk;Kim, Minsun;Choi, Kisun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.9
    • /
    • pp.5-12
    • /
    • 2018
  • The foundation of the multi-span greenhouse structures is designed with small shallow concrete foundation considering mainly the vertical load. However, recently, due to an abnormal climate such as strong wind, horizontal load and up-lift load over design strength are applied to the foundation, causing safety problems of the greenhouse foundation. In order to reasonably evaluate the safety of greenhouse foundations, rotational and pullout stiffness expressed by the ground-foundation interaction should be evaluated, which also affects the safety of the upper structural members. In this study, three representative basic foundation types were selected by classifying greenhouse standards in Korea according to the shape, and the horizontal loading tests and theoretical calculation were performed for each foundation type. As a result of the comparison and analysis of the test and calculation, it was found that rotational resistance of the foundation is different according to the ratio of the contact area between the foundation and ground when the conditions of the foundation - ground contact surface and the mechanical properties of the ground are the same.