• Title/Summary/Keyword: Concrete Surface Roughness

Search Result 81, Processing Time 0.031 seconds

Penetration Properties of Airborne Chlorides on Concrete Exposed in Marine Environment (해안환경에 노출된 콘크리트의 비래염분 침투 특성)

  • Lee, Jong-Suk;An, Gi-Hong
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.5
    • /
    • pp.553-558
    • /
    • 2012
  • Airborne chlorides are transported to inland by sea wind to be attached to seashore concrete structure surface then penetrated into concrete structure members. Since the surface attached chloride amount are dependent on the amount of airborne chlorides, the prediction of distribution of airborne chlorides is important information in preventing chloride corrosion problems in seashore concrete structures. The prediction of surface chloride amount from airborne chlorides environment is extremely difficult than concrete directly in contact with seawater. In addition, their penetrating tendency is different from that of concrete immersed in seawater. In this study, properties of surface and penetrated chlorides under airborne chlorides environment are investigated. Concrete specimens were manufactured and exposed to marine environment for 3 years. The specimens were analyzed at the time durations of 1, 2, and 3 years to check surface chloride amount to penetrated chloride depth. The results revealed that there were certain differences according to surface roughness of concrete and with and without washing effect due to rainfalls. The evaluation results showed that penetrated chlorides depend on amount of airborne chlorides and duration of exposure. In addition, a notable tendency of having deeper chloride penetration and higher chloride content in concrete members under long-term exposure was observed.

An Experimental Study on Evaluation of Bond Strength of Arc Thermal Metal Spaying According to Treatment Method of Water Facilities Concrete Surface (수처리 시설물 콘크리트 표면처리 방법에 따른 금속용사 피막의 부착성능 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Lee, Han-Seung;Shin, Jun-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.2
    • /
    • pp.107-115
    • /
    • 2016
  • In this study, the bond strength of metal spraying system by surface treatment of concrete (waterproof/corrosion method) in water treatment facilities was evaluated. The results showed that the system with Sa-P-R-(S) (sanding-perviousness surface hardener-surface roughness agent-metal spraying-sealing) led to the desirable performance. The bond strength, the coefficient of water permeability and air permeability were 3.7MPa, $0.68{\ast}10^{-8}cm/sec$, and $0.45{\ast}10^{-16}m^2$, respectively. In scanning electron microscope analysis, the microstructure of specimen coated with perviousness surface hardener was much denser than that without it. Therefore, the specimen coated with sanding-perviousness surface hardener-surface roughness agent-metal spraying-sealing had the best bond performance and was the most suitable system to concrete surface in water treatment facilities.

Effect of the Various Curing Temperatures on the Finishability of Concrete using Aluminum Form (알루미늄 거푸집을 이용한 콘크리트의 양생온도변화에 따른 표면마감성에 관한 연구)

  • Lee, Dong-Gyu;Kim, Tae-Cheong;Baek, Dae-Hyun;Lee, Seong-Hoon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.969-972
    • /
    • 2008
  • This study investigated the effect of the fundamental condition such as release agent, form conditions and types to the surface of concrete with aluminum form on the various temperatures. On the observation with the naked eyes, coated plywood and aluminum form without a scratch showed similar result, and the surface quality of the concrete with aluminum form was gradually decreased corresponding to the increase of the temperature.For the surface roughness, there is no remarkable tendency according to the temperature. However, the difference in accordance with release agent occurred.As void on the surface corresponding to the various temperature, the micro voids ranged $0.1{\sim}1mm$ were increased corresponding to the increasing temperature, so it was confirmed that the chemical reaction wae accelerated. And the voids of the other range also increased. the fundamental condition such as release agent, form conditions and types

  • PDF

Optimal Mix Design Model of Recycled Aggregate Concrete for Artificial fishing Reefs (인공어초용 재생골재 콘크리트의 최적 배합설계 모델)

  • 홍종현;김문훈;우광성;고성현
    • Journal of Ocean Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.53-62
    • /
    • 2004
  • The Purpose of this study is to recycle the waste concrete, which is generated in huge quantities, from construction works. in order to achieve this goal, it is important to determine the compressive strength, workability, slump, and ultrasonic velocity of recycled aggregate concrete. Thus, several experiment parameters are considered, such as water-cement ratios, sand percentage, and fine aggregate composition ratios, in order to apply the recycled aggregate concrete to pre-cast artificial fishing reefs. From the results, it has been shown that the proper mix designs for reef concrete are W/C=45%, S/a=50%, SR50:SN50 in recycled sand and natural sand mix combination case, W/C=45%, S/a=50%, SC50:SN50 in crushed sand and natural sand mix combination case, W/C=45%, S/a=50%, SR50:SC50 in recycled sand and crushd sand mix combination case. Also, this study shows that the shape and surface roughness of fine aggregate particles have an effect on the strength, slump, ultrasonic velocity of tested concrete, and the compressive strength ratios of 7days' and 90days' curing ages of recycled aggregate concrete are about 70% and 110% of 28days' curing age.

A Numerical Study on Shear Behavior of the Interface between Blasted Rock and Concrete (발파 암반-콘크리트 경계면에서의 전단거동특성에 대한 수치해석적 연구)

  • Min, Gyeong-Jo;Ko, Young-Hun;Fukuda, Daisuke;Oh, Se-Wook;Kim, Jeong-Gyu;Chung, Moon-Kyung;Cho, Sang-Ho
    • Explosives and Blasting
    • /
    • v.37 no.4
    • /
    • pp.26-35
    • /
    • 2019
  • In designing a gravity-type anchorage of earth-anchored suspension bridge, the contact friction between a blasted rock mass and the concrete anchorage plays a key role in the stability of the entire anchorage. Therefore, it is vital to understand the shear behavior of the interface between the blasted rock mass and concrete. In this study, a portable 3D LiDAR scanner was utilized to scan the blasted bottom surfaces, and rock surface roughness was quantitatively analyzed from the scanned profiles to apply to 3D FEM modelling. In addition, based on the 3D FEM model, a three-dimensional dynamic fracture process analysis (DFPA-3D) technique was applied to study on the shear behavior of the interface between blasted rock and concrete through direct shear tests, which was analyzed under constant normal load (CNL). The effects of normal stress and the joint roughness on shear failure behavior are also analyzed.

Modeling the transverse connection of fully precast steel-UHPC lightweight composite bridge

  • Shuwen Deng;Zhiming Huang;Guangqing Xiao;Lian Shen
    • Advances in concrete construction
    • /
    • v.15 no.6
    • /
    • pp.391-404
    • /
    • 2023
  • In this study, the modeling of the transverse connection of fully precast steel-UHPC (Ultra-High-Performance Concrete) lightweight composite bridges were conducted. The transverse connection between precast components plays a critical role in the overall performance and safety of the bridge. To achieve an accurate and reliable simulation of the interface behavior, the cohesive model in ABAQUS was employed, considering both bending-tension and compression-shear behaviors. The parameters of the cohesive model are obtained through interface bending and oblique shear tests on UHPC samples with different surface roughness. By validating the numerical simulation against actual joint tests, the effectiveness and accuracy of the proposed model in capturing the interface behavior of the fully precast steel-UHPC lightweight composite bridge were demonstrated.

Evaluation of Bonding Performance in UHPC-based Concrete Repair Materials Considering Surface of Structure Subject to Repair (보수대상 구조 표면 상태를 고려한 UHPC 기반 콘크리트 보수재료의 부착 성능 평가)

  • Yong-Sik Yoon;Kyong-Chul Kim;Kwang-Mo Lim;Gi-Hong An;Gum-Sung Ryu;Kyung-Taek Koh
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.11 no.4
    • /
    • pp.433-439
    • /
    • 2023
  • In this study, the bonding performance of repair materials was evaluated on concrete repair surface to develop concrete repair materials based on UHPC (Ultra High Performance Concrete) which has high mechanical and durability performance. The ten test variables were applied considering the roughness and wet condition of the concrete surface subject to repair, the addition of polymer, and the use PP and PVA fibers in repair materials. The addition of the polymer caused a significant decrease in strength, which was thought to be due to the effect of the additional super plasticizer used to adjust workability. Also, flow was reduced by up to 13.8 % with the use of plastic-based fibers. As a result of evaluating the bond strength of the repair material considering the condition of the surface subject to repair, it was thought that in the case of using UHPC-based repair material, high bonding performance could be secured without any additional surface treatment as long as the surface of the base material was sound. In addition, UHPC-based repair materials showed high bonding performance even when the attachment surface was wet. In the future, research will be conducted on shot-crete application and gradient pouring for the development of UHPC-based repair materials, and continuous improvement in the repair material mixing property will be carried out to ensure economic efficiency and performance as a concrete structural repair material.

Debonding strain for steel-concrete composite slabs with trapezoidal metal deck

  • Claudio Bernuzzi;Marco A. Pisani;Marco Simoncelli
    • Steel and Composite Structures
    • /
    • v.49 no.1
    • /
    • pp.19-30
    • /
    • 2023
  • Steel-concrete composite slabs represent a very efficient floor solution combining the key performance of two different materials: the steel and the concrete. Composite slab response is governed by the degree of the interaction between these two materials, mainly depending by chemical and mechanical bond. The latter is characterized by a limited degree of confinement if compared with the one of the rebars in reinforced concrete members while the former is remarkably influenced by the type of concrete and the roughness of the profiled surface, frequently lubricated during the cold-forming manufacturing processes. Indeed, owing to the impossibility to guarantee a full interaction between the two materials, a key parameter governing slab design is represented by the horizontal shear-bond strength, which should be always experimentally estimated. According to EC4, the design of the slab bending resistance, is based on the simplified assumption that the decking sheet is totally yielded, i.e., always in plastic range, despite experimental and numerical researches demonstrate that a large part of the steel deck resists in elastic range when longitudinal shear collapse is achieved. In the paper, the limit strain for composite slab, which corresponds to the slip, i.e., the debonding between the two materials, has been appraised by means of a refined numerical method used for the simulation of experimental results obtained on 8 different composite slab types. In total, 71 specimens have been considered, differing for the properties of the materials, cross-section of the trapezoidal profiled metal sheets and specimen lengths.

A Study on Control of Sealing Robot for Cracks of Concrete Surface (콘크리트 표면 균열 실링을 위한 로봇의 제어 방법에 관한 연구)

  • Cho, Cheol-Joo;Lim, Kye-Young
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.2
    • /
    • pp.481-491
    • /
    • 2015
  • Since the crack in the surface of the concrete acts as the main reason influencing the life span of the structure, regular inspections and maintenance are required. The sealing required for maintenance of the concrete surface is a method of repairing the crack in the surface in the beginning, and is effective in preventing additional cracks and expansion that occurs with time. However, sealing on large sized structures such as tall buildings or bottom parts of bridges are difficult to ensure safety of the workers due to inadequate working environments. Due to this reason, the importance of the need for sealing automation for the maintenance of large sized concrete structures is emerging. This study proposes two control methods to apply robot systems to the sealing of cracks on the bottom parts of concrete bridges. First is the method of automatically tracking the trajectory of cracks. The robot gets the trajectory of the cracks using video information obtained from cameras. Comparing the previous several points and new point, the next point can be estimated. Thus, the trajectory of the crack can be tracked automatically. The other method is sealing by maintaining steady force to the contacting surface. The concrete surface exposed to an external environment for a long time gets an irregular roughness. If robots are able to carry out sealing while maintaining a steady contact force on these rough surfaces, complete equal sealing can be maintained. In order to maintain this equal force, a force control method using impedance is proposed. This paper introduces two developed control methods to apply to sealing robots, and conducts a Lab Test and Field Test after applying to a robot. Based on the test results, opinions on the possibilities of field application of the robot applied with the control methods are presented.

Tensile Bond Characteristics between Underwater Coating Materials and Concrete Substrate (수중코팅제와 콘크리트 모재 간의 인장 부착 특성)

  • Kim, Min Ook;Jeong, Yeonung;Kang, Sung-Hoon;Moon, Juhyuk;Yi, Jin-Hak
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.30 no.6
    • /
    • pp.298-305
    • /
    • 2018
  • In this study, we investigated the tensile bond characteristics of underwater coating materials, in order to obtain useful information in support of repair work for marine and coastal concrete structures. Test variables included type of underwater coating, surface conditions of the concrete substrate, and environmental conditions. Pull-off tensile bond strength was measured at 24 h after applying underwater coatings to concrete substrates, in compliance with the procedures specified in ASTM C1583. Failure modes (coating, interface, and parent concrete) for each coating were identified through visual inspection, and comparisons were made based on measured bond strength. The tensile bond strength decreased underwater compared to that under dry conditions, while no significant effect of surface roughness on the measured bond strength was observed in underwater tests. Key aspects that need to be considered regarding selection and use of underwater coating materials for marine and coastal concrete structures were discussed.