• 제목/요약/키워드: Concrete Pile Anchor

검색결과 8건 처리시간 0.018초

콘크리트 파일앵커의 설치 매니퓨레이터의 개발을 위한 모형실험에 관한 연구 (Model Test for the Development of Installing Manipulator of Concrete Pile Anchor)

  • 윤길수;김호상
    • 한국해양공학회지
    • /
    • 제18권1호
    • /
    • pp.47-52
    • /
    • 2004
  • Greater holding force of an anchor is required for maintaining the position of a larger floating structure. According to the series of model tests of pile anchors with movable fluke, the square type pile anchor, with fluke, showed more than 6 times of the uplift pulling force, compared to the same type pile anchor, without fluke. This uplift force is 100 times its weight. When the water depth is more than 40m, It is difficult to install the pile anchor. For a convenient installation method, a type of manipulator is proposed for the separation of a weight and buoyancy controller, using TRIZ.

Application of numerical simulation for the analysis and interpretation of pile-anchor system failure

  • Saleem, Masood
    • Geomechanics and Engineering
    • /
    • 제9권6호
    • /
    • pp.689-707
    • /
    • 2015
  • Progressive increase in population causing land scarcity, which is forcing construction industry to build multistory buildings having underground basements. Normally, basements are constructed for parking facility. This research work evaluates important factors which have caused the collapse of pile-anchor system at under construction five star hotel. 21 m deep excavation is carried out, to have five basements, after installation of 600 mm diameter cast in-situ contiguous concrete piles at plot periphery. To retain piles and backfill, soil anchors are installed as pit excavation is proceeded. Before collapse, anchors are designed by federal highway administration procedure and four anchor rows are installed with three strands per anchor in first row and four in remaining. However, after collapse, system is modeled and analyzed in plaxis using mohr-coulomb method. It is investigated that in-appropriate evaluation of soil properties, additional surcharge loads, lesser number of strands per anchor, shorter grouted body length and shorter pile embedment depth caused large deformations to occur which governed the collapse of east side pile wall. To resume work, old anchors are assumed to be standing at one factor of safety and then system is analyzed using finite element approach. Finally, it is concluded to use four strands per anchor in first new row and five strands in remaining three with increase in grouted and un-grouted body lengths.

매입말뚝의 인발저항특성에 관한 연구 (Analytical Study on the Pullout Resistance Characteristics of Bored Pile)

  • 박종배;천영수
    • 토지주택연구
    • /
    • 제7권4호
    • /
    • pp.281-289
    • /
    • 2016
  • 압축 부재인 PHC 말뚝(직경 600mm)도 강선의 부착력을 높이면 83.6~91.6tonf의 극한 인장력에 대해 구조적으로 저항할 수 있는 것으로 실험결과 나타났다. 이러한 시험결과에 안전율을 고려하여 적절한 허용값을 제시하면 부상방지 앵커를 대체하거나 절감시킬 수 있는 것으로 기대되었다. 이를 위해서는 구조적 인장성능과 함께 실제 지반에 시공된 매입말뚝의 인발저항 거동이 규명되어야 한다. 본 연구에서는 현장에 시공된 실제 매입말뚝의 인발거동 특성을 파악하기 위하여 정적 인발재하시험을 실시하여 주면마찰력 산정식과 비교하였다. 또한, 간편하게 인발저항력을 평가하기 위하여 PDA를 이용한 동재하시험을 실시하여 정적 인발재하시험 결과와 비교하였다. 그 결과, 매입말뚝의 시멘트풀이 충분히 경화한 후인 15일 후에는 LH 주면마찰력 산정식의 마찰력과 정적인발재하시험결과가 잘 일치하였고 동재하시험에서 구한 마찰력과도 비교적 잘 일치하는 것으로 나타났다.

아치형 해저 케이블 보호 구조물의 앵커 충돌 수치 시뮬레이션 (Numerical Simulation of Arch-type Submarine Cable Protector under Anchor Collision)

  • 우진호;나원배;김헌태
    • 한국해양공학회지
    • /
    • 제23권1호
    • /
    • pp.96-103
    • /
    • 2009
  • In 2006, Jeju Island in South Korea experienced a crisis, no electricity for three hours anywhere in the entire island. This incident was caused by a domino effect that occurred after one of the submarine power cables connecting the island to Haenam, a coastal city on the mainland, was damaged by an external load, probably from a ship anchor or a steel pile being used in marine farming. This study presents a collision analysis of a new submarine power cable protector called arch type reinforced concrete. For the analysis, a dynamic finite element program, ANSYS AUTODYN, was used to examine the displacement and stress of the submarine power cable protector using different material models (RHT concrete model, Mohr.Coulomb concrete model). In addition, two reinforcing bar spacings, 75 mm and 150 mm, were considered. From the analyses, the effects of the parameters (concrete model and spacing) on the results (displacement and stress) were analyzed, and the relations between the damage and parameters were found.

천해역 점성토 지반에 적합한 오탁방지막 기초 앵커 (Compatible Anchors of Silt Protector in Shallow Sea with Mud Seafloor Material)

  • 권기철;홍남식;송무효;최창규
    • 한국해양공학회지
    • /
    • 제17권3호
    • /
    • pp.7-12
    • /
    • 2003
  • The Navy has tested the holding capacity of many kinds of anchors in order to propose the design chart for the holding capacity of drag-embedment anchors. The design chart is only applicable up to the cable bottom angle 60 when load is raised to the ultimate weight. However, the anchor experiences a significant uplift force when the angle is above 60 in shallow seas. In this paper, the procedure for the estimation of the holding capacity of anchors in mud is proposed. Drag-embedment anchors do not function well when there is a significant uplift component of load in soft seafloor materials, such as mud. Under these loading and seafloor conditions, gravity anchors seems to be more efficient. However, they are too heavy for their holding capacity. Therefore, suction pile (hollow concrete block) is more beneficial to the foundntion of silt protector in shallow sea with mud seafloor materials.

확대기초의 신구 콘크리트 접합 모형실험 (Mock-Up Test for Connection of New-Old Concrete of Footing)

  • 황철성;유성원
    • 한국건설순환자원학회논문집
    • /
    • 제6권1호
    • /
    • pp.66-71
    • /
    • 2018
  • 일반적으로 소구경 말뚝을 이용한 기존교각의 확대보강을 시행하는 경우 접합부의 일체성을 유지하기 위해 후 설치 앵커 중에서 이형철근을 사용한 부착식 앵커를 사용한다. 그러나 부착식 앵커의 경우 접합재의 종류 등에 따라 성능이 크게 좌우됨에도 불구하고 기계식 앵커와는 달리 설계방법의 표준화와 함께 적절한 성능평가를 위한 표준적인 실험방법도 제시되지 않고 있는 실정이다. 이에 따라 본 연구에서는 철근의 겹이음 및 앵커철근을 이용한 모형실험을 실시하여 부착식 앵커의 성능에 대한 평가를 수행하였다. 실험 결과, 접합하지 않은 시험체의 구조 성능이 가장 우수하게 나타났으며, 파괴양상은 펀칭전단 파괴로 나타났다. 연결되지 않은 부재가 연결된 부재보다는 부재 끝단의 처짐이 더 작게 발생되며, 큰 크기로 연결된 부재의 처짐이 작게 연결된 부재의 처짐보다는 크게 나타나, 하중이 증가할수록 앵커 철근 또는 겹이음 철근의 미끌림 등의 현상이 발생될 가능성이 큰 것으로 나타났다.

CT형강 전단연결재가 적용된 합성형 PHC벽체파일-하부슬래브 연결부 성능에 관한 실험적 연구 (An Experimental Study on Structural Capacity of Joint Between Composite PHC Wall Pile and Bottom Slab with CT Shear Connector)

  • 마호성;원정훈;이종구
    • 한국강구조학회 논문집
    • /
    • 제25권5호
    • /
    • pp.531-541
    • /
    • 2013
  • 본 연구에서는 합성형 PHC 벽체파일의 CT형강 전단연결재가 벽체파일과 하부 슬래브와의 연결부에서 인장력에 저항하는 앵커의 성능을 갖는지 직접 인발실험을 통해 분석하였다. 다양한 실물 크기 실험체들의 파괴형상과 하중-변위 곡선으로부터 CT형강의 인발파괴를 방지하기 위해서는 CT형강 복부 홀에 관통철근을 배치하여 강도를 증가시켜야 함을 알 수 있다. 관통철근이 설치된 다양한 단면의 실험체들을 대상으로 지지점 거리를 변화시켜 파괴형상과 극한강도를 분석한 결과, CT형강의 인발파괴 전에 벽체파일 자체의 콘크리트 인장파괴가 모든 실험체에서 발생하므로 적용된 CT형강 전단연결재는 벽체파일과 하부 슬래브 연결부의 발생 인장력에 대해 충분히 저항할 수 있다.

육상풍력터빈 확대기초의 재사용을 위한 보강방법에 관한 실험적 연구 (An Experimental Study on Reinforcement Method for Reuse of Onshore Wind Turbine Spread Footing Foundations)

  • 송성훈;정연주;박민수;김정수
    • 대한토목학회논문집
    • /
    • 제41권1호
    • /
    • pp.1-11
    • /
    • 2021
  • 기존 육상풍력터빈의 리파워링 시 기존 기초를 재사용하기 위해서는 증가된 타워 직경 및 터빈 하중에 맞게 기존 기초를 재설계 및 보강하는 것이 중요하다. 본 연구에서는 육상풍력터빈의 기초형식 중 가장 널리 사용되고 있는 확대기초의 재사용을 위해 기존 확대기초 위에 새로운 콘크리트 기초부를 증설하는 슬래브 확장 보강방법 및 앵커부 구조디테일에 대해 검토하였다. 그리고 앵커부 구조디테일에 따른 보강된 확대기초의 하중저항성능을 실험적으로 평가하였다. 실험결과, (1) 앵커부 철근 유무에 따라 내력이 30 % 이상 증가하였다. (2) 앵커링에 부착된 Pile-sleeve는 앵커링과 콘크리트 사이의 전단슬립거동을 방지하여 회전강성 증가에 기여하였다. (3) Slab connector는 신?구 콘크리트 분리 방지 및 일체화 거동을 향상시켜 내력 및 변형능력 증가에 기여하였다.