• 제목/요약/키워드: Concrete Mix Design

검색결과 468건 처리시간 0.026초

고강도 콘크리트의 실용화를 위한 연구 (A Study for the Application of High-Strength Concrete)

  • 이장화;유영찬;민병렬;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1991년도 가을 학술발표회 논문집
    • /
    • pp.140-145
    • /
    • 1991
  • Tests were conducted to get a mix proportioning of high strength concrete between σ28 and (C/W) using low quality materials easily purchased in situ. Superplasticizer was used as a chemical admixture to compensate low slump of base concrete keeping it up about 15±2㎝. General material properties such as modulus of elasticity, poisson's ratio, unit weight and stress-strain characteristic of high strength concrete were obtained. Test results show that mix proportioning of high strength concrete proposed in this paper have reasonable validity and these can be used as a design criteria in high strength concrete construction.

  • PDF

고성능 콘크리트 배합 설계에서의 유전자 알고리즘의 적용 (Genetic Algorithm in Mix Proportioning of High -Performance Concrete)

  • 임철현;윤영수;이승훈;손유신
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.551-556
    • /
    • 2002
  • High-performance concrete is defined as concrete that meets special combinations of performance and uniformity requirements that cannot always be achieved routinely using conventional constituents and normal mixing, placing, and curing practices. Ever since the term high-performance concrete was introduced into the industry, it had widely used in large-scale concrete construction that demands high-strength, high-flowability, and high-durability. To obtain such performances that cannot be obtained from conventional concrete and by the current method, a large number of trial mixes are required to select the desired combination of materials that meets special performance. In this paper, therefore, using genetic algorithm which is a global optimization technique modeled on biological evolutionary process-natural selection and natural genetics-and can be used to find a near optimal solution to a problem that may have many solutions, the new design method for high-performance concrete mixtures is suggested to reduce the number of trial mixtures with desired properties in the field test. Experimental and analytic investigations were carried out to develop the design method for high-performance concrete mixtures and to verify the proposed mix design.

  • PDF

Mix Design and Properties of Recycled Aggregate Concretes: Applicability of Eurocode 2

  • Wardeh, George;Ghorbel, Elhem;Gomart, Hector
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권1호
    • /
    • pp.1-20
    • /
    • 2015
  • This work is devoted to the study of fresh and hardened properties of concrete containing recycled gravel. Four formulations were studied, the concrete of reference and three concretes containing recycled gravel with 30, 65 and 100 % replacement ratios. All materials were formulated on the basis of S4 class of flowability and a target C35 class of compressive strength according to the standard EN 206-1. The paper first presents the mix design method which was based on the optimization of cementitious paste and granular skeleton, then discusses experimental results. The results show that the elastic modulus and the tensile strength decrease while the peak strain in compression increases. Correlation with the water porosity is also established. The validity of analytical expressions proposed by Eurocode 2 is also discussed. The obtained results, together with results from the literature, show that these relationships do not predict adequately the mechanical properties as well as the stress-strain curve of tested materials. New expressions were established to predict the elastic modulus and the peak strain from the compressive strength of natural concrete. It was found that the proposed relationship E-$f_c$ is applicable for any type of concrete while the effect of substitution has to be introduced into the stress-strain (${\varepsilon}_{c1}-f_c$) relationship for recycled aggregate concrete. For the full stress-strain curve, the model of Carreira and Chu seems more adequate.

근대 건축에 사용된 시멘트계 재료의 배합 특성 (A Study on the Properties of Mix Design for Cementitious Material used in Modern Architecture)

  • 이찬영;안재철;송종목;강병희;김기수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.215-216
    • /
    • 2012
  • The purpose of this study is to analyze the situation and feature of construction technology by analysis properties and the mixture proportion of a reinforced concrete building from the modern domestic and to leave technological records for the optimal maintenance of the cultural heritage. The study says, the case of the 1:3:6 mix concrete has been standard regardless of the kind of structures after the concrete has being used in earnest, However, The strength range is big from Water-Cement ratio difference according to the concrete casting site.

  • PDF

농업용 폐비닐로 개질한 아스팔트 콘크리트의 배합설계 (Mix Design for Waste PE Films Modified Asphalt Concrete)

  • 김광우;이상범;오성균;고동혁;정승호
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.313-318
    • /
    • 1999
  • This study is basic research to improve quality of asphalt concrete mixture, to preserve environment, and to recycle waste vinly. The mixing method and proper content of waste vinyl were determined through preliminary mix design. This study performed mix designs using 2 type gradations of aggregate in addtion content of wate vinly. Marshall stability at optimum asphalt content of asphalt concrete mixture addtin wate vinly was satisfied with the specification of the Ministry of Construction and Transportation , and its values indicated that dense grade asphalt concrete mixture containing waste vinyl were higher than common dense grade mixture (control). From this study, it was confirmed that addtion of waste vinyl improved quality of asphalt concrete mixture.

  • PDF

An approach of using ideal grading curve and coating paste thickness to evaluate the performances of concrete-(1) Theory and formulation

  • Wang, H.Y.;Hwang, C.L.;Yeh, S.T.
    • Computers and Concrete
    • /
    • 제10권1호
    • /
    • pp.19-33
    • /
    • 2012
  • The performance of a concrete is significantly influenced by its mixture proportion and the coating thickness on aggregate surface. The concrete in this study is designed by estimating the blending ratio of aggregate using a densified mixture design algorithm (DMDA) based on an ideal grading curve and estimating the paste volume as the sum of the amount of paste needed to provide an assigned coating paste thickness. So as to obtain appropriate concrete amount, and thus can accurately estimate the property of concrete. Deduction of this mix design formula is simple and easy understanding, and meanwhile to obtain result is fast. This estimation model of mix design is expected to reward to industry and effectively upgrade concrete quality.

수중불분리성 콘크리트의 해양공사 적용에 관한 기초적 연구 (A Fundamental Study on the Antiwashout Underwater Concrete for the Underwater Work of Ocean)

  • 김명식;윤재범;박세인
    • 콘크리트학회논문집
    • /
    • 제12권5호
    • /
    • pp.25-34
    • /
    • 2000
  • When concrete is placed underwater, it is diluted with separating cementitious material and as a result the quality of concrete becomes poor. To solve this problem, antiwashout underwater concrete is increasingly used for the construction and repair of the concrete structure underwater. The objective of this study is to investigate the characteristics of antiwashout underwater concrete as to the mix proportion, casting and curing water through experimental researches. The unit weight of water and cement, water-cement ratio, fine aggregate ratio, unit weight of antiwashout underwater agent and superplasticizer, and casting and curing water were chosen to measure the suspended solids, pH, air contents, slump flow, unit weight of hardened concrete, and compressive strength. From this study, the incremental modulus at mix proportion design and unit weight of antiwashout underwater agent were increased more than fresh water, and it is a optimum mix proportion that the unit weight of water(and cement) is 230kg/$\textrm{m}^3$(460kg/$\textrm{m}^3$), waterOcement ratio is 50%, fine aggregate ratio is 40%, unit weight of antiwashout underwater agent is 1.2% of water contents per unit weight of concrete, and unit weight of supeplasticizer is 2.5% of cement contents per unit weight of concrete when the antiwashout underwater concrete is used for the underwater work of ocean.

레디믹스트 콘크리트의 배합설계(配合設計)를 위한 컴퓨터의 이용에 관한 연구(研究) (Computer Application in Mix Design of Ready Mixed Concrete)

  • 문한영;최재진
    • 대한토목학회논문집
    • /
    • 제6권1호
    • /
    • pp.69-78
    • /
    • 1986
  • 레디믹스트 콘크리트의 품질은 시멘트의 품질, 골재의 입도 및 표면수 등과 같은 사용재료의 변화에 의하여 크게 변화하므로, 사용재료의 변화상태를 신속히 파악하여 배합계산에 반영함으로써 품질변화를 최대한 방지해야 한다. 본 논문에서는 레디믹스트 콘크리트의 배합계산에 컴퓨터를 사용함으로써 재료의 변화상태에 따른 배합수정을 정확하고 신속하게 처리하여 시방배합, 현장배합 및 배치량을 계산할 수 있는 프로그램을 작성하였다.

  • PDF

3성분계 시멘트를 사용한 매스콘크리트의 시공사례 (An Application of the Mass Concrete Using Ternary Blended Cement)

  • 권영호;하재담;전성근;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.1229-1234
    • /
    • 2001
  • The bottom slab of Inchon LNG in-ground #213 tank is designed as a massive structure witch has a large depth and section. The purpose of this study is to determine the optimum mix design having good workability and low hydration heat for bottom slab concrete and to control the actual concrete quality in site. For this purpose, we select the optimum mix design used ternary blended cement(furnace slag cement+fly ash) and design factors. As test results of actual application, we have finish placing the bottom slab concrete of 23,180㎥ during 68hours with good success and obtain the good quality of fresh and hardened concrete including slump, air contents, no-segregation, compressive strength and low hydration heat in actual data. All test results are satisfied with our specifications for bottom slab concrete and we cut costs as the use of ternary blended cement and the reduction of placing hours.

  • PDF

A Study on the Optimum Mix Proportion of the Mass Concrete Designed as Massive and Deep Structure

  • Kwon Yeong-Ho;Lee Hwa-Jin
    • 콘크리트학회논문집
    • /
    • 제17권2호
    • /
    • pp.293-302
    • /
    • 2005
  • This study describes data from determination of the optimum mix proportion and site application of the mass concrete placed in bottom slab and side wall having a large depth and section as main structures of LNG in-ground tank. This concrete requires low heat hydration, excellent balance between workability and consistency because concreting work of LNG in-ground tank is usually classified by under-pumping, adaptation of longer vertical and horizontal pumping line than ordinary pumping condition. For this purpose, low heat Portland cement and lime stone powder as cementitious materials are selected and design factors including unit cement and water content, water-binder ratio, fine aggregate ratio and adiabatic temperature rising are tested in the laboratory and batch plant. As experimental results, the optimum unit cement and water content are selected under $270kg/m^3$ and $l55{\~}l60 kg/m^3$ separately to control adiabatic temperature rising below $30^{\circ}C$ and to improve properties of the fresh and hardened concrete. Also, considering test results of the confined water ratio($\beta$p) and deformable coefficient(Ep), $30\%$ of lime stone powder by cement weight is selected as the optimum replacement ratio. After mix proportions of 5cases are tested and compared the adiabatic temperature rising($Q^{\infty}$, r), tensile and compressive strength, modulus of elasticity, teases satisfied with the required performances are chosen as the optimum mix design proportions of the side wall and bottom slab concrete. $Q^{\infty}$ and r are proved smaller than those of another project. Before application in the site, properties of the fresh concrete and actual mixing time by its ampere load are checked in the batch plant. Based on the results of this study, the optimum mix proportions of the massive concrete are applied successfully to the bottom slab and side wall in LNG in-ground tank.