• 제목/요약/키워드: Concrete Filled Steel Tube(CFT)

검색결과 198건 처리시간 0.031초

800MPa 고강도 강재 및 100MPa 초고강도 콘크리트를 활용한 CFT 합성 구조 시스템 개발을 위한 현장 성능평가에 관한 연구 (Research on the Mock-up for CFT Using 100MPa High Strength Concrete and 800MPa High Strength Steel)

  • 김우재;이영도;박희곤;이재삼;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 2부
    • /
    • pp.35-37
    • /
    • 2011
  • This study was a comparison result between the laboratory and mock up test to apply the ultra high strength concrete to CFT(Concrete Filled Tube) structure. The investigated result of tendency and quality similarity of each specimen, was set up a management range according to checking the validity and suitability analysis. Also, It wil be utilized to data as construction guidelines of CFT.

  • PDF

재하가열시험에 의한 무내화피복 콘크리트충전 각형강관기둥의 내화성능평가 (Evaluation of Fire Resistance of Unprotected Concrete-filled Rectangular Steel Tubular Columns under Axial Loading)

  • 안재권;이철호
    • 한국강구조학회 논문집
    • /
    • 제26권4호
    • /
    • pp.323-334
    • /
    • 2014
  • 본 연구에서는 표준화재에 노출된 무피복 콘크리트충전강관(CFT)기둥의 내화성능 및 거동 특성을 파악하고자 화재실험 및 수치해석 연구를 수행하였다. 실험변수로는 기둥높이, 하중비, 단면크기를 고려하였고, 이들이 CFT 기둥의 내화성능에 미치는 영향을 알아보고자 단면내 온도변화 및 축변형을 분석하였다. 실험결과 모든 실험체의 강관에서 국부좌굴이 발생, 콘크리트로 하중전이가 일어났고, 이후 콘크리트 압괴로 이어졌다. 이는 CFT 기둥의 전체 휨좌굴과 함께 국부좌굴이 내화설계의 주요 변수로 고려되어야 함을 시사한다. 하중비가 증가할수록 콘크리트저항구간이 줄어들면서 전체적인 내화시간이 감소하였다. 강재한계온도에 근거한 합성부재의 내화성능평가는 실제 하중지지력에 의한 내화시간에 비해 다소 보수적임을 확인하였고, 기존 연구자들의 제안식에 의한 성능예측결과도 실제 내화성능과 비교해볼때 개선의 여지가 있었다. 화재시 CFT 기둥의 내화성능을 예측하기 위하여 유한요소해석을 수행하였고, 실험결과와 비교할 때 신뢰성 있는 예측값을 나타냄을 확인하였다.

2심 냉간성형 각형 CFT기둥-보 접합부의 구조거동 (Structural Behavior of Two-Seam Cold Formed Square CFT Column to Beam Connections)

  • 오헌근;김선희;박찬면;최성모
    • 한국공간구조학회논문집
    • /
    • 제12권4호
    • /
    • pp.81-90
    • /
    • 2012
  • The concrete-filled tube (CFT) column has the excellent structural performance. But it is difficult to connect with column and beam because of closed section. Its Solution, 2 members of ㄷchennel in which Internal diaphragm is installed were welded beforehand and the method of making Rectangular Steel Tube was proposed. According to upside and downside junction shape, Internal diaphragm suggested as symmetric specimen and asymmetric specimen. The upper and lower diaphragm of the Symmetric specimen used the same horizontal and The upper diaphragm of the Asymmetric specimen used the horizontal plate and the lower diaphragm used the vertically plate. In this research, 4 T-shape column to beam steps connections were tested with cyclic loading experiment in order to evaluate the structural capability of the offered connection. Symmetric specimens be a failure in 0.03rad from beam flange. And Asymmetric specimens be a failure in 0.05rad from column interface. The comparison results of All specimens shown similar to energy absorption capacity in 0.02rad.

A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads

  • Park, Su-Hee;Choi, Sung-Mo;Chung, Kyung-Soo
    • Steel and Composite Structures
    • /
    • 제8권6호
    • /
    • pp.491-510
    • /
    • 2008
  • This paper presents a plan and guidelines that were drawn for Korean based research carried out on the fire-resistance of CFT columns. This research was carried out by reviewing the Korean regulations related to the fire-resistance of CFT columns and examining studies which had been made in Korea as well as overseas. The first phase of the study plan was to compare the fire-resistance of square CFT columns without fire protection (obtained through fire-resistance tests and numerical analyses) with estimated values (obtained through fire-resistance design formulas proposed in Korea and overseas). This comparison provided conclusions as outlined below. Fire-resistance tests conducted in this study proved that, when the actual design load is taken into consideration, square CFT columns without fire protection are able to resist a fire for more than one hour. A comparison was made of test and analysis results with the fire-resistance time based on the AIJ code, the AISC design formula and the estimation formula suggested for Korea. The results of this comparison showed that the test and analysis results for specimens SAH1, SAH2-1, SAH2-2 and SAH3 were almost identical with the AIJ code, the AISC design formula and estimation formula. For specimens SAH4 and SAH5, the estimation formula was more conservative than the AIJ code and the AISC design formula. It was necessary to identify the factors that have an influence on the fire-resistance of CFT columns without fire protection and to draw fire-resistance design formulas for these columns. To achieve this, it is proposed that numerical analyses and tests be conducted in order to evaluate the fire-resistance of circular CFT columns, the influence of eccentricity existing as an additional factor and the influence of the slenderness ratio of the columns. It is also suggested that the overall behavior of CFT structures without fire protection within a fire be evaluated through analysis simulation.

중공형 콘크리트 충전 FRP Tube 말뚝의 휨강도 산정 (An Evaluation of Flexural Strength of Hollow Concrete Filled FRP Tube Piles)

  • 김형준;정흥진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권6호
    • /
    • pp.204-211
    • /
    • 2022
  • 본 연구에서는 복합말뚝의 장점을 활용하고 CFT말뚝의 단점인 부식에 대한 문제점을 해결할 수 있는 모델로 중공형 콘크리트 충전 FRP Tube 말뚝(Hollow Concrete Filled FRP Tube Pile, HCFFT말뚝)을 제시하였고, 수치해석 모델을 개발하여 거동을 분석하였다. 콘크리트가 손상 소성 거동, 강재가 항복 소성 거동, FRP가 탄성 거동을 한다는 것을 고려하여 변형률적합법을 적용하고, 중립축으로부터의 거리에 따른 FRP Tube 단면의 변화를 고려하여 HCFFT말뚝의 휨 강도 산정식을 제안하였다. 휨 강도 산정식과 수치해석 결과, 실험결과를 비교 분석하여 적정성을 검증하였다. 본 연구 결과는 FRP를 이용한 다양한 HCFFT말뚝의 최적설계에 기초자료로서 활용될 수 있을 것으로 판단된다.

일정 축력을 받는 Double CFT기둥의 내화성능 평가 (Fire Resistance of Concrete Filled Double Skin Tubular Columns under Axial Load)

  • 정상근;김선희;이성희;최성모
    • 한국강구조학회 논문집
    • /
    • 제23권1호
    • /
    • pp.51-59
    • /
    • 2011
  • 높은 축력비가 적용된 무피복 CFT기둥은 보통 중저층 건물에서 2시간 이하의 내화성능을 확보하는데 적용 가능하나, 고층건물에서 요구되는 3시간의 내화성능을 만족시키지는 못한다. 따라서 고층건물에 무피복 CFT기둥을 적용하기 위해서는 추가적인 내화성능 향상방안이 제시되어야 한다. 이에 본 연구에서는 무피복 CFT기둥의 내화성능 향상방안으로써 Double CFT기둥을 설정하였다. 본 연구에서는 실대크기의 무피복 CFT기둥과 Double CFT기둥에 대한 재하가열실험을 수행하였다. 이를 통해, Double CFT기둥의 적용에 따른 내화성능 향상 효과 및 강관의 단면형상 변화에 따른 영향을 비교 평가해 보고자 한다.

충전원형강관을 이용한 모듈러 교각의 휨 거동 평가 (Evaluation of Flexural Behavior of a Modular Pier with Circular CFT)

  • 마향욱;오현철;김동욱;;심창수
    • 한국강구조학회 논문집
    • /
    • 제24권6호
    • /
    • pp.725-734
    • /
    • 2012
  • 모듈화된 급속시공 교량 구조물의 하부구조 형식으로 충전 원형강관을 이용한 교각 구조물을 제안하였다. 다수의 충전강관을 연결하여 표준화된 제품으로 생산하여 운반 조립할 수 있는 구조 상세와 연결 상세를 제안하였다. 제안된 구조상세와 연결상세를 반영한 모듈러 교각의 정적실험을 강축과 약축에 대해서 횡변위 조건으로 수행하였다. 단일 기둥으로 설계한 것에 비하여 모듈러 CFT 교각 시스템이 브레이싱으로 연결된 편심효과로 인해 5.23배 높은 휨강성을 나타내었고 휨강도도 6배 이상 증가하였다. 합리적인 설계를 위해서는 모듈러 CFT 교각을 프레임으로 모델링하여 응력 및 처짐 검토를 수행하는 것이 타당한 것으로 나타났다. 교각을 구성하는 기둥간의 간격 조정을 통해서 필요한 내하력을 확보할 수 있을 것으로 판단되고 설계를 위한 고려사항을 제안하였다.

철골형 CFT 프레임을 활용한 내진보강 복합공법 개발 (Development of Seismic Strengthening Composite Method using Steel type CFT Frame)

  • 이동운;우종열;박현정
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.101-102
    • /
    • 2018
  • There is a risk that the damage caused by frequent earthquakes can lead to the risk of personal injury due to cracks in buildings and collapse of major structures. Although the seismic design of the new building is designed to be reinforced, the existing structure is not exposed to the risk of earthquake. Therefore, it is aimed to develop the steel frame type CFT composite method which can easily reinforce the CFT structural system with excellent seismic performance against the old non - seismic structure.

  • PDF

CFT 교각 기초부의 거동특성 (Behavior of the Foundation of Concrete Filled Steel Tubular Pier)

  • 이하림;김희주;황원섭
    • 한국전산구조공학회논문집
    • /
    • 제24권5호
    • /
    • pp.491-498
    • /
    • 2011
  • 본 연구는 CFT 교각 기초부의 구조상세 개선을 목적으로 상용 유한요소해석 프로그램인 ABAQUS를 이용하여 축하중 및 횡하중을 받는 강재기둥 베이스플레이트 접합부의 전반적인 구조적 거동과 설계변수의 영향을 검토하고자 한다. 이를 위해 현행 교각 기초부의 설계기준을 분석하였고, 선행연구의 실험을 토대로 수치해석을 실시하여 해석기법의 타당성을 검증하였다. 검증된 해석기법을 이용하여 교각 기초부의 파괴형상 및 응력분포를 분석하였으며, 다양한 설계변수(베이스플레이트, 이형철근, 기둥의 강종 및 치수)가 전체 구조물에 미치는 영향을 비교분석하였다.

편심압축이 작용하는 HCFT기둥에 대한 내력특성과 모멘트-곡률의 곤계 (Strength and Moment-Curvature Relationship of HCFT Columns under Eccentric Load)

  • 이승조;박정민;김화중
    • 콘크리트학회논문집
    • /
    • 제14권6호
    • /
    • pp.864-873
    • /
    • 2002
  • 현재의 CFT기둥 구조에 대한 연구는 대부분 강재측 측면에서 접근한 연구와 강관 내부에 충전되는 콘크리트의 충전성 등과 같은 시공적 측면에 대한 연구성과가 주류로 되고 있으며, 콘크리트 측면에서의 연구는 미흡한 실정이다. 이것에 대한 연구를 중심으로 HCFT 기둥이 축력아래에서 단주가 동일한 휨-모멘트를 받을 때의 변형성능(M-ø)에 대하여 해석적으로 수치적인 값을 검토하였다. 그리고, 기본적인 가정을 바탕으로 실험에서 얻은 CFT 단면의 변형성능의 해석에 대하여 모멘트-축력-곡률관계의 해석 프로그램의 개발(C-Language)을 실시하였다. 따라서, 본 연구에서는 폭-두께비(D/t), 세장비(λ), 콘크리트의 종류를 주요변수로 하여 편심하중 아래에서의 강도 600kgf/$\textrm{cm}^2$를 충전한 HCFT 기둥에 대한 내력 및 곡률과 같은 구조적 특성을 고찰하였으며, AISC-LRFD, AIJ, Tokanori Sato의 식을 이용한 내력설계식의 비교분석을 실시하였다. 본 연구에서 검토한 내력 및 곡률은 향후 HCFT 기둥에 대한 내력설계식의 제안 및 해석에 유용하게 적용될 수 있을 것으로 사료된다.