• 제목/요약/키워드: Concrete Characteristics

검색결과 3,893건 처리시간 0.031초

고속철도 궤도 타입에 따른 진동 특성 (Vibration Characteristics of High-speed Railway Lines on the Type of Track)

  • 이찬우;함염삼;김재철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.332-336
    • /
    • 2011
  • IN THIS STUDY, BASED ON THE TYPE OF HIGH SPEED RAILWAY TRACK VIBRATION CHARACTERISTICS WERE MEASURED AT KTX VEHICLE. KTX ROUTE BALLASTED TRACK HAS BEEN INSTALLED TOGETHER WITH THE CONCRETE TRACK. CONCRETE MUST BE TRACK IRREGULARITY THAN BALLASTED TRACK, VEHICLES VIBRATION VALUES THAT ARE SMALLER. ALSO, IN TERMS OF MAINTENANCE, CONCRETE TRACK IS KNOWN TO BE MORE FAVORABLE THAN THE BALLASTED TRACK. PHASE 2 IS THE KTX, DAEGU - BUSAN IS A SECTION OF CONCRETE TRACK. IN THIS STUDY, "KUUNG-BU HIGH-SPEED RAILWAY LINES" INSTALLED ON THE CONCRETE TRACK AND BALLASTED TRACK KTX FROM THE VEHICLE WHEN INSTALLED BETWEEN RAILS, SLEEPER AND BALLAST ON THE TRACK WAS MEASURED VIBRATIONS.

  • PDF

Seismic behavior of high-strength concrete flexural walls with boundary elements

  • Kim, Seung-Hun;Lee, Ae-Bock;Han, Byung-Chan;Ha, Sang-Su;Yun, Hyun-Do
    • Structural Engineering and Mechanics
    • /
    • 제18권4호
    • /
    • pp.493-516
    • /
    • 2004
  • This paper addresses the behavior and strength of structural walls with a concrete compressive strength exceeding 69 MPa. This information also enhances the current database for improvement of design recommendations. The objectives of this investigation are to study the effect of axial-load ratio on seismic behavior of high-strength concrete flexural walls. An analysis has been carried out in order to assess the contribution of deformation components, i.e., flexural, diagonal shear, and sliding shear on total displacement. The results from the analysis are then utilized to evaluate the prevailing inelastic deformation mode in each of wall. Moment-curvature characteristics, ductility and damage index are quantified and discussed in relation with axial stress levels. Experimental results show that axial-load ratio have a significant effect on the flexural strength, failure mode, deformation characteristics and ductility of high-strength concrete structural walls.

콘크리트 슬러지를 이용한 인공골재 의 품질특성 (The Quality Characteristics of Artificial Aggregate using Concrete Sludge)

  • 고대형;이정재;문경주;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.269-274
    • /
    • 2001
  • The purpose of this study is to evaluate basic properties of artificial aggregate using concrete sludge according to mixing ratio. Cement, waste phosphogypsum and Powder of blast furnace slag are used with binder of artificial aggregate. Specific gravity, absorption are tested for basic property, and impacting, abrasion and crushing tests are done for characteristics of strength on the aggregate, including comparison with crushed stone. Bry specific gravity was ranged about 1.16 to 1.30 the test result of the aggregates and shape is round In the result of tests, it is concluded that qualities of the aggregates using concrete sludge are slightly lower than crushed stone but it is similiar with sintering artificial lightweight aggregate in high temperature.

  • PDF

지중송전 케이블 되메움 콘크리트의 열 저항 특성에 관한 연구 (A Study on the Thermal Resistance Characteristics of Backfill Concrete for Underground Power Cables)

  • 정원섭;권기주;김대홍
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.397-402
    • /
    • 2001
  • Due to the recent economic growth and the subsequent increase in demand of electricity, the construction of underground transmission line is also on the rise. Especially, in the metropolitan area, we have much obstruction in laying the line to the central district because of difficulties in procurement of construction land and the increase in the construction cost. Therefore, the necessity of increasing the capacity of transmission line has been suggested. In order to increase the capacity, the electric voltage and current intensity in size-limited lines should be also increased. But, eventually, it leads to the generation of unnecessary heat and the heat radiates through insulation cables and backfill concrete. So we need to develop the material that has good heat radiation characteristics. In this study, we developed and tested backfill concrete that can be a substitute for previously used backfill sand.

  • PDF

휨보강된 철근콘크리트보의 확률론적 고찰 (Probabilistic Considerations on Strengthened Reinforced Concrete Beam for Flexural Loads)

  • 이차돈;최봉섭;김수정
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.733-738
    • /
    • 2001
  • Although there are strong needs for evaluating statistical characteristics of strengthened reinforced concrete beams under flexure, many researches have been performed mostly on the mechanical properties and failure mechanisms. Different material properties and resulting reinforcing effect could alter the probabilistic values of the strengthened beams. Existing equations suggested for predicting flexural strengthened reinforced concrete beam with CFRP and steel plate are selected and best-fitting one is used in evaluating probability of failure based on Monte-Carlo method. Influential factors are statistically examined and approximate strength reduction factors are suggested. It was found that the factor is more sensitively influenced by predictive equations as well as characteristics and amounts of strengthening materials.

  • PDF

에이징 처리한 콘크리트용 제강슬래그 골재의 품질 (The Properties of Steel Slag Aggregate Treated with Aging Process in Concrete)

  • 문한영;유정훈;천승환;백우열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.105-108
    • /
    • 2001
  • In this paper, we evaluated the suitability of steel slag(is divided with electric arc furnace slag and converter slag) as concrete aggregate by measuring physical and chemical characteristics of it. The steel slag mainly contains SiO$_2$ and CaO as the chemical composition. The reaction with water and a little of free CaO in the slag causes slag's volume to expand. Therefore, we used several aging methods in order to decrease the characteristics of slag volume expansion. The physical properties of steel slag aggregate are researched and then the strength of concrete with the steel slag aggregate is measured.

  • PDF

철근콘크리트 구조물의 축소모델 재료의 역학적 특성에 관한 실험적 연구 (An Experimental Study on the Mechanical Characteristics of Materials for Reduced-Scale Models of Reinforced Concrete Structures)

  • 배성용;이한선;신영식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1994년도 가을 학술발표회 논문집
    • /
    • pp.249-254
    • /
    • 1994
  • The main objectives of this paper are to compare the obtained mechanical characteristics of reduced-scale model materials with those of the prototype and to provide the information on the best selection of materials. Manufacturing techniques on the micro-concrete and reduced reinforcement are introduced. The test results of these materials are shown to be satisfactory with regard to the similitude requrement. The simple beam tests were performed to verify similitude in the bond behavior between micro-concrete and reduced reinforcement. Those results also prove that these manufacturing and experimental techniques are useful and reliable for reduced-scale model test.

  • PDF

고강도 경량콘크리트의 실용화를 위한 기초적 실험연구 (Fundamental Tests for General Use of High-Strength Lightweight Concrete)

  • 김형태;김원근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 봄 학술발표회 논문집
    • /
    • pp.39-44
    • /
    • 1990
  • This experimental study is performed by using artificial lightweight aggregate manufactured in laboratory, and the test results of it are compared with those using foreign materials in respect of design compressive strength, unit weight. The tests on strength characteristics such as bending, splitting tensile strength and on mechanical characteristics including σ-εcurve, elastic modulus, poisson's ratio are performed to provide the fundamental data required for the design. From this study, it is possible to obtain the high-strength concrete having compressive strength of 500 kg/㎠ and unit weight of 1.85-2.0 t/㎥. And also it is recommended that sandlightweight concrete having high specfic strength is more practical for general use.

  • PDF

부분 프리스트레스트 콘크리트 슬래브의 휨 균열 거동에 관한 실험적 연구 (An Experimental Study on the Flexural Cracking Behavior of Partially Prestressed Concrete Slabs)

  • 박홍용;연준희;최익창
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1990년도 봄 학술발표회 논문집
    • /
    • pp.108-115
    • /
    • 1990
  • This paper contains experimental studies on the flexural cracking behabior of PPC one-way slabs. Three post tensioned bonded PPC slabs with the same prestressing ratio and ultimate moment strength were tested. Based upon test results, this paper also presents the crack width prediction formula PPC slab. According to the crack theory developed mainly in Europe, crack width formula is given as the product of crack spacing and mean steel strain after decompression. Aaaaverage crack spacing formula is composed of many factors mainly such as concrete cover, concrete effective area in tension, sum of reinforcing bars perimeters and mixed reinforcements. In particular, it is very important to specify the bond characteristics of mixed reinforcements, since bond characteristics of PC bars are different from those of non-tensioned deformed bars. For this reason, a reduced bond coefficients for PS bars is employed in this study.

  • PDF

잔골재 조립율이 고성능콘크리트의 특성에 미치는 영향 (The Effect of Fine Aggregate Fineness modulus on Properties High Performance Concrete)

  • 이승한;정용욱;박태현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.388-391
    • /
    • 2004
  • This research investigates how the fineness modulus of fine aggregates and the grain shape of coarse aggregates affects flow characteristics, packing characteristics and compressive strength characteristic. The experimental results, show that increase of the fine aggregate's fineness modulus improved concrete flow, but filling ability was high at over KS regulation extent due to segregation phenomena. It is considered that the improvement of 0.1 spherical rate was effective to concrete fluidity elevation by reducing about $6\%$ of fine aggregate ratio displays which the smallest gap rate of aggregate. Compressive strength was increased to about 0.6MPa everytime F.M. 0.1 of fine aggregate fineness is increased. However, it was decreased to about 9MPa at F.M. 3.5 compared to F.M. 3.0.

  • PDF