• Title/Summary/Keyword: Concourse

Search Result 37, Processing Time 0.029 seconds

Empirical Propagation Path Loss Model for ATC Telecommunication in the Concourse Environment (콘코스 환경에서 항공 정보통신의 실험적인 전파 경로 모델에 관한 연구)

  • Kim, Kyung-Tae;Park, Hyo-Dal
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.9
    • /
    • pp.765-772
    • /
    • 2013
  • In this paper, we studied the path loss model of Air Traffic Control(ATC) telecommunication radio channel at the Incheon International Airport(IIA) concourse area. We measured wave propagation characteristics on the two frequencies among VHF/UHF channel bands. The transmitting site radiated the Continuous Wave(CW). The propagation measurement was taken using the moving vehicle equipped with receiver and antenna. The transmitting power, frequency, and antenna height are the same as the current operating condition. The path loss exponent and intercept parameters were extracted by the basic path loss model and hata model. The path loss exponents at Concourse area were 3.1/3.13 and 3.01/3.38 respectively in 128.2MHz and 269.1MHz. The deviation of prediction error is 2.77/3.17 and 4.01/3.66. The new path loss equation at the Concourse area was also developed using the derived path loss parameters. The new path loss model was compared with other models. This result will be helpful for the ATC site selection and service quality evaluation.

Evaluation of VOCs in Subway (지하철역사에서의 휘발성 유기화합물 농도 평가)

  • 최우건;배상호;박덕신;정우성;김태오
    • Proceedings of the KSR Conference
    • /
    • 2002.05a
    • /
    • pp.572-576
    • /
    • 2002
  • Volatile Organic Compounds(VOCs) contribute to the formation of ozone and PAN which are injurious to health through complex photochemical reactions. Growing consumption of fossil fuels results in significant emission of VOCs and other air pollutants into the atmosphere. In this study, Ambient an grab samples of VOCs were collected at the platform and the concourse of six stations in the subway from February 21th to 28th. Among the total contents, Toluene (118.74 ppm) showed the highest concentration in the Indukwon station platform while other contents were measured low concentrations. Also, the platform concentrations were higher than the concourse concentrations through the whole contents.

  • PDF

Status of particulate matter pollution in urban railway environments (도시철도 환경의 미세먼지 오염 현황)

  • Kim, Jong Bum;Lee, Seung-Bok;Bae, Gwi-Nam
    • Journal of odor and indoor environment
    • /
    • v.17 no.4
    • /
    • pp.303-314
    • /
    • 2018
  • The urban railway system is a convenient public transportation system, as it carries many people without increasing traffic congestion. However, air quality in urban railway environments is worse than ambient air quality due to the internal location of the source of air pollutants and the isolated space. In this paper, characteristics of particulate matter (PM) pollution in urban railway environments are described from the perspective of diurnal variation, chemical composition and source apportionment of PM. PM concentrations in concourse, platform, passenger cabin, and tunnel are summarized through an analysis of 34 journal articles published in Korea and overseas. This information will be helpful in developing effective policies to reduce PM pollution in urban railway environments.

The Pattern of the Attitude of Pregnant Women on Breast Feeding (임부의 모유 수유에 대한 태도 유형 분석)

  • Chung, Hae-Gung;Lee, Mi-La
    • 모자간호학회지
    • /
    • v.3 no.2
    • /
    • pp.126-141
    • /
    • 1993
  • The purpose of this study was to understand the pattern of the pregnant women' attitude on breast feeding. The research had been proceeded as follows ; 1. Delineation of the Q-population the statements of Q-population had been derived from review of the related literature and a open-ended questionnaire filled by nurses, nursing students, general public, and the pregnant women. Total number of concourse collected was 105. 2. Selection of the Q-sample : Among 105 concourse, those which has obscure or overlapped were deleted. 38 concourse were selected finally. 3. Selection of the P-sample : by the convenient sampling technique, 28 subjects had been deter mined among the pregnant women who visited a hospital affiliated with university for the antenatal care, from March to August, 1993. 4. Q-sorting : based on 1 to 9 point scale (forced normal distribution), the selected P-sample rated their operant definition of breast feeding. 5. Determination of Q-type : with Q-sorts, PC-Quanal program identified the three Q-types. 6. Analysis of Q-type : the characteristics of three different attitude had been analyzed based on the typal array, extreme comments, and subject$\sim$s demographic information. The results revealed that there are three different altitudes nth regard to breast feeding : Instinct oriented attitude, Science oriented attitude, and Convenience oriented altitude. Mothers with Instinct oriented attitude and Science oriented altitude are thought to have high possibility to breastfeed their infant willingly, and mothers with Convenience oriented attitude to breast feed under the favorable conditions. These findings can be used as the information giving data for the education to encourage breast feeding.

  • PDF

Evaluation on Indoor Air Quality by Statistical Analysis of Indoor Air Pollutants Concentration in a Seoul Metropolitan Underground Railway Station (서울시 지하역사 실내오염물질 농도자료의 통계분석을 통한 실내공기질 특성 평가)

  • Yim, Bongbeen;Lee, Kyusung;Kim, Jooin;Hong, Hyunsu;Kim, Jangwon;Jo, Kyung-Ho;Jung, Eulgyu;Kim, Inkyu;An, Yeonsun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.3
    • /
    • pp.233-244
    • /
    • 2014
  • The objective of this study was to explore the characteristics of concentration of indoor air pollutants, such as $PM_{10}$, $CO_2$, and $NO_2$, measured by tele-monitoring system in a Seoul Metropolitan underground railway station from January 1, 2008 to December 31, 2012. The annual average concentration of indoor air pollutants actually varied over a wide range and was found to exhibit marked variation with time and measurement sites (tunnel inlet, platform, and concourse). After installing platform screen doors, the average $PM_{10}$ concentration on platform and concourse was decreased by 43.8% and 31.2%, respectively during the study periods. The relationship between the concentration of $PM_{10}$ and meteorological parameters (relative humidity and rainfall) or the Asian dust events was regarded as statistically significant. The correlations between the number of boarding/alighting passengers and $PM_{10}$, $CO_2$, and $NO_2$ were calculated. A p-value of less than 0.01 was regarded as significant except $NO_2$. The I/O ratio of $PM_{10}$ concentration was elevated after a congested time (about 08:00 am). The average I/O ratios of $NO_2$ were observed in concourse and platform on 03:00 am with $1.76{\pm}0.91$ and $1.50{\pm}0.51$, respectively. The average daily variation of standard excess rate of $PM_{10}$ and $NO_2$ concentration in concourse and platform was investigated. The highest standard excess rate was observed on 21:00 (09:00 pm).

Estimation of Diffusion Direction and Velocity of PM10 in a Subway Station (For Gaehwasan Station of Subway Line 5 in Seoul) (지하철 역사 미세먼지(PM10)의 확산방향과 확산속도 추정 (서울 지하철 5호선 개화산역을 대상으로))

  • Park, Jong-Heon;Park, Jae-Cheol;Eum, Seong-Jik
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.5
    • /
    • pp.55-64
    • /
    • 2010
  • In order to prepare an efficient solution for PM10 reduction in underground stations, the authors measured PM10 concentration levels every 30 minutes in the concourse, platform, and tunnel of Gaehwasan Station of Seoul's subway line 5. Through a correlation analysis of each changing pattern of PM10 concentration, the direction and velocity of diffusion in underground stations were estimated. The PM10 concentration levels were highest in the tunnel, followed by the platform and concourse. PM10 concentrations in the tunnel, platform, and concourse showed a pattern of increasing in the rush hours and decreasing in the non-rush hours. According to the statistical analysis of PM10 concentrations and changing patterns in each location, the higher PM10 concentration in the tunnel expanded to the platform, and some from the platform expanded to the concourse. Therefore, to efficiently reduce PM10 concentrations, it is essential to detect the centralized generation, diffusion factor, expanding route, expanding measure, and other variables and to remove or reduce the diffusion factor and level. Through operating the ventilation system in the right time frame while the PM10 concentration level increases, the power consumption and peak power consumption can be reduced.

PERFORMANCE EVALUATION OF PASSENGERS' EVACUATION FOR SMOKE-CONTROL MODES IN A SUBWAY STATION (지하역사 제연모드 승객피난 성능평가)

  • Park, Won-Hee;Chang, Hee-Chul;Jung, Woo-Sung;Lee, Han-Su
    • Journal of computational fluids engineering
    • /
    • v.13 no.4
    • /
    • pp.8-12
    • /
    • 2008
  • Heat/smoke detectors are installed in most subway platforms in Korea to detect fire. Subway platform is divided by smoke-control zones for efficient smoke-control. Once the detectors detect heat or smoke, the smoke-control ventilation system in the platform and concourse is activated according to the smoke-control ventilation mode. Smoke-control mode during fires in Korean subway platforms is that the smoke zones operate by exhausting smoke while other zones in the platform and in the concourse which is the upper floor of the platform operate by supplying air or stopping any ventilation. This study is conducted to evaluate performance of passengers' evacuation for various smoke control modes in the subway station. Distribution of smoke and heat due to fire on the platform is analyzed by using Fire Dynamics Simulator(FDS V 4.06) of NIST. Various smoke-control ventilation modes and locations of fire are considered. Evacuation and movement of passengers within the platform is simulated by building EXODUS V.4.0.

A Study on the Type of Community and Behavior of users in the General Hospitals in Korea (국내 종합병원의 공용공간에서 나타나는 군집유형과 이용행태에 관한 조사 연구)

  • Son, Ji-Hye;Yang, Nae-Won
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.5
    • /
    • pp.191-199
    • /
    • 2009
  • Recently general hospitals in Korea are focusing on healing environment which care for patients on the side of spirit and psychology without medical treatment. For the reason, architects are planning a public space on a large scale in which can be held cultural performances and artistic events. Those of social activities can be effective healing environment according to the "Anthroposophical medicine" studied by Rudolf Steiner. To the patient, Social healing environment is relation with normal life and back to the life. The case of a large-scale public space on hospital in foreign country shows the effect of healing environment through social community. So it is valuated as a social healing environment and community space. Even though the large-scale public space has been being increased in our circumstance, there is no evaluation of use on it. So there is no idea how people are satisfied with public space to stay and form a concourse by themselves. The purpose of this study is to find out the desire of people, who use the large-scale public space by analysis of observation research and interview in the general hospitals. And finally this study suggests the factors which can realize social healing environment on the planning of public space in hospital architecture.

A Study on the Spatial Configuration of Internal Functions of Public Area in City Hotels - Focusing on middle size first-class hotels in Korea and Japan - (도시 호텔 공용부문에 나타난 내부기능구성형식에 관한 연구 - 한국과 일본의 중규모 특급호텔을 중심으로 -)

  • 이창노
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.5
    • /
    • pp.125-132
    • /
    • 2004
  • The purpose of this study is focused on defining the types of spatial configuration of internal functions in city hotels by researching and analyzing city hotels in Korea and Japan. The scope of this study is limited to the period of early 1980's to the end of 1990's and 18 city hotels in Korea and Japan are selected as subject. Researching existing records and analyzing plans, surveys are used as the method of the study. The result of this study is as follow. First, block composition of floor plans that is used for hotel construction could be divided into three types (immanent type-6hotels, combined type-7hotels, adjacent type-4hotels). Second, the result of analysis about the internal functions and structural types of public area in city hotels is as follow. More Korean city hotels are taking concourse type (Korea 77.8%, Japan 55.6%) and hall type (Korea 22.2%, Japan 11.1%) than Japanese city hotels. However, the mixed type (concourse type +hall type) is only used in Japan (Korea 0%, Japan 33.3%). Third, as the result of the comparison of the size of public area between Korea and Japan, Korean hotels (36.70%) have larger space than Japanese hotels only in the service area. public (Korea 33.98% < Japan 34.71%), business (Korea 27.68% Japan 31.41%)and empty (Korea 1.64% < Japan 6.13%) area is taking larger space in Japanese city hotels than Korean.

Performance Evaluation of Passengers' Evacuation for Smoke-Control Modes in a Subway Station Based on CFD Results (전산열유체 해석결과를 이용한 지하역사 제연모드 승객피난 성능평가)

  • Park, Won-Hee;Jang, Yong-Jun;Lee, Han-Su;Chang, Hee-Chul;Lee, Duck-Hee
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.276-279
    • /
    • 2008
  • Heat/smoke detectors are installed in most subway platforms in Korea to detect fire. Subway platform is divided by smoke-control zones for efficient smoke-control. Once the detectors detect heat or smoke, the smoke-control ventilation system in the platform and concourse is activated according to the smoke-control ventilation mode. Smoke-control mode during fires in Korean subway platforms is that the smoke zones operate by exhausting smoke while other zones in the platform and in the concourse which is the upper floor of the platform operate by supplying air or stopping any ventilation. This study is conducted to evaluate performance of passengers' evacuation for various smoke control modes in the subway station. Distribution of smoke and heat due to fire on the platform is analyzed by using Fire Dynamics Simulator(FDS V 4.06) of NIST. Various smoke-control ventilation modes and locations of fire are considered. Evacuation and movement of passengers within the platform is simulated by buildingEXODUS V 4.0.

  • PDF