• Title/Summary/Keyword: Concentration rms

Search Result 52, Processing Time 0.048 seconds

Development and Validation of Reference Material for Proficiency Testing of Blood Heavy Metals in Environmental Biomonitoring (환경 바이오모니터링에서의 혈중 중금속 분석 숙련도 시험을 위한 표준물질 제조 및 적용성 평가)

  • Im, Hosub;Yang, Minho;Oh, Selim;Kim, Soyoung;Jung, Hojun;Cho, Yong Min;Lee, Jung Sub;Kim, Hyun Jeong;Lee, Chae Kwan;Moon, Chan-Seok;Lee, Jong-Wha
    • Journal of Environmental Health Sciences
    • /
    • v.42 no.6
    • /
    • pp.450-464
    • /
    • 2016
  • Objectives: This study developed and validated reference materials (RMs) to analyze metal compounds in blood. Methods: We referred to KoNEHS (Korea National Environmental Health Survey) to estimate concentrations of blood metals (cadmium, Cd; lead, Pb; mercury, Hg) and applied analytical methods (inductively coupled plasma - mass spectroscopy, ICP-MS, for Cd and Pb; graphite furnace - atomic absorption spectrometry, GF-AAS, for Cd and Pb; and direct mercury analyzer, DMA, for Hg). Homogeneity and stability tests were carried out. In addition, certified values and uncertainties of RMs were calculated through internal and external experiments. All RMs were developed and assessed in various forms according to element, analytical method, and two types of concentration levels high concentration for occupational exposure and low concentration for environmental exposure. Results: All samples showed acceptable homogeneity, except for low concentration of Cd in the GF-AAS method. Short- and long-term stabilities were satisfied by ANOVA testing. In the inter-laboratory comparison, robust medians were lower than the certified values of all RMs (robust median/reference value; $1.301/1.327{\mu}g/L$ for Cd, ICP-MS, low concentration; $3.152/3.388{\mu}g/L$ for Cd, ICP-MS, high concentration; $1.219/1.301{\mu}g/L$ for Cd, GF-AAS, low concentration; $3.074/3.321{\mu}g/L$ for Cd, GF-AAS, high concentration; $14.473/14.516{\mu}g/L$ for Pb, ICP-MS, low concentration; $50.069/50.114{\mu}g/L$ for Pb, ICP-MS, high concentration; $12.881/14.147{\mu}g/L$ for Pb, GF-AAS, low concentration; $47.015/47.591{\mu}g/L$ for Pb, GF-AAS, high concentration; $4.059/4.218{\mu}g/L$ for Hg, DMA, low concentration; $11.474/11.181{\mu}g/L$ for Hg, DMA, high concentration). Conclusion: This study demonstrates procedures for developing and validating RMs for biomonitoring in the field of the environmental health.

The Study on Analytical Method of Lead, Cadmium and Chromium in Copper Metal by Matrix Matching Method of Inductively Coupled Plasma Atomic Emission Spectrometer (유도결합 플라즈마 발광분광기의 매트릭스 보정법에 의한 구리 중납, 카드뮴 및 크롬 분석에 관한 연구)

  • Joo, Sung-Kyun;Kim, Joon;cheong, Nam-Yong;Lim, Kyu-Chual;Choi, Young-Hwan;Kim, Sang-Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.3
    • /
    • pp.293-301
    • /
    • 2009
  • Analytical results of a fixed concentration of Pb, Cd and Cr in the synthetic copper standard solution (RMs) for using the matrix no matched standard calibration curve at various wavelength by ICP showed that accuracy (140 $\sim$ 1,070% in case of Pb) is very poor at all wavelengths because of the Cu matrix effect. Analytical results of a fixed concentration of Pb, Cd and Cr in the different concentration solutions of Cu showed that found values were on the increase or decrease as the rate of a regular equation as the concentration of Cu was increased. Accuracies by the Cu matching method in the analysis of Pb, Cd and Cr in the synthetic copper standard solution (RMs) were higher than 99.9%.

CFD Analysis on the Effect of the Nozzle Arrays and Spray Types in the Hydrogen Peroxide Mixing Quencher to Improve the Mixing Efficiency (과산화수소 혼합냉각기 내의 노즐배치 및 가스분사 방식 변화에 따른 혼합율 개선에 대한 전산해석적 연구)

  • Koo, Seongmo;Chang, Hyuksang
    • Clean Technology
    • /
    • v.23 no.1
    • /
    • pp.42-53
    • /
    • 2017
  • Numerical analysis was done to evaluate the fluid distribution inside of the mixing quencher to increase the reaction efficiency of the aqueous hydrogen peroxide solution in the scrubbing column which is used for simultaneous desulfurization and denitrification. Effective injection of the aqueous hydrogen peroxide ($H_2O_2$) solution in the mixing quencher has major effects for improving the reaction efficiency in the scrubbing column by enhancing the mixing of the aqueous $H_2O_2$ solution with the exhaust gas. The current study is to optimize the array of nozzles and the spray angles of the aqueous $H_2O_2$ solution in the mixing quencher by using the computational method. Main concerns of the analysis are how to enhance the uniformity of the $H_2O_2$ concentration distribution in the internal flow. Numerical analysis was done to check the distribution of the internal flow in the mixing quencher in terms of RMS values of the $H_2O_2$ concentration at the end of quencher. The concentration distribution of $H_2O_2$ at the end of is evaluated with respect to the different array of the nozzle pipes and the nozzle tip angles, and we also analyzed the turbulence formation and fluid mixing in the zone. The effect of the spray angle was evaluated with respect to the mixing efficiency in different flow directions. The optimized mixing quencher had the nozzle array at location of 0.3 m from the inlet duct surface and the spray angle is $15^{\circ}$ with the co-current flow. The RMS value of the $H_2O_2$ concentration at the end of the mixing quencher was 12.4%.

Numerical Study on the Arrangement of AIG for Determining the $NH_3$ Concentration Distribution in the Package Type of Small Scale SCR System (패키지형 소형 SCR 시스템 내 $NH_3$ 농도분포 제어를 위한 AIG의 배치에 관한 전산해석적 연구)

  • Park, Seon-Mi;Chang, Hyuk-Sang;Zhao, Tong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.368-377
    • /
    • 2011
  • A package type of SCR (selective catalytic reduction) system that was proposed for removing the $NO_x$ found in flue gas from the small scale of air pollution sources was evaluated. The efficiency of the SCR system is determined by the proper utilization of catalytic media installed inside of the system, and the proper distribution of flow velocity and $NH_3$ concentration in the flue gas is a crucial factor for using the catalytic media. In this study, the distributions of $NH_3$ concentration were estimated under the various arrays and shapes of AIG at the given gas flow condition. The value of RMS (%) in $NH_3$ concentration is 95.3% at co-current flow (at $0^{\circ}$) injection but it is 90.1% at the condition of counter-current flow (at $120^{\circ}$) condition, which implies the counter-current injection is more favorable. By rearranging the $NH_3$ injection flow rates based on the distribution of velocity and $NH_3$ distribution in basic calculation, the value of RMS (%) in $NH_3$ concentration was reduced to 62.8%. The enhanced effect of $NH_3$ mixing by the combined effect of arrays and shapes are complied in the study.

Concentration Fluctuation of a Coaxial $CO_2$/Air Jet Excited Acoustically (음파가진에 의한 동축 $CO_2$/공기 제트의 농도변동 특성 연구)

  • Han, Yong-Shik;Kim, Myung-Bae;Kim, Tae-Kwon
    • 연구논문집
    • /
    • s.23
    • /
    • pp.57-62
    • /
    • 1993
  • An experimental investigation was carried out to study the characteristics of concentration of a coaxial jet being tone excited and consisting of $CO_2$, and air. The concentration in a binary gas mixture was measured by using the hot-wire anemometer and flow visualization was performed by the schlieren technique. In the case of excited flow, it is found that acoustic energy is partially transferred to RMS concentration to enhance mixing.

  • PDF

A Study on the Mixing of Dilution Air and Ammonia in the Ammonia Mixing Pipe of the Thermal Power Plant De-NOx Facility (화력발전소 탈질설비의 암모니아 혼합 관에서 희석 공기와 암모니아의 혼합에 관한 연구)

  • Kim, Ki-Ho;Ha, Ji-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.2
    • /
    • pp.49-55
    • /
    • 2022
  • According to reinforce environmental regulations, coal power plants have used selective catalytic reduction using ammonia as a reducing agent to reduce the amount of nitrogen oxide generation. The purpose of the present study was to derive a mixing device for effectively mixing dilute air and ammonia in the ammonia mixing pipe by performing computational fluid dynamic analysis. The mixing effect was compared by analysing the %RMS of ammonia concentration at the down stream cross section in the mixing pipe and the 16 outlets based on the case 1-1 shape, which is an existing mixing pipe without a mixing device. The mixing device was performed by changing the positions of a square plate on the downstream side of the ammonia supply pipe and an arc-shaped plate on the wall of the mixing pipe. In the case of the existing geometry(Case 1-1), the %RMS of ammonia concentration at the 16 outlets was 29.50%. The shape of the mixing device for Case 3-2 had a square plate on the downstream side of the ammonia supply pipe and an arc plate was installed adjacent to it. The %RMS of ammonia concentration for Case 3-2 was 2.08% at 16 outlets and it could be seen that the shape of Case 3-2 was the most effective mixing shape for ammonia mixing.

Combustion Characteristics of a Turbulent Diffusion Flat Flame According to Oxygen Enriched Concentration of Combustion Air (연소공기의 산소부화농도에 따른 난류확산 평면화염의 연소특성)

  • Kwark, Ji-Hyun;Jeon, Chung-Hwan;Chang, Young-June
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.3
    • /
    • pp.281-288
    • /
    • 2004
  • Combustion using oxygen enriched air is an energy saving technology that can increase thermal efficiency by improving the burning rate and by increasing the flame temperature. Flame figures, OH radical intensities, temperature distributions and emissions concentration were examined according to oxygen enriched concentration(OEC) in a turbulent diffusion flat flame. As long as the oxygen enriched concentration was increased, the length and volume of the flat flame was decreased while OH radical intensity was raised and the flame temperature was increased. However, RMS of the fluctuating temperature was decreased, and more homogeneous temperature field was formed. Thermal NO also was increased with increase of oxygen enriched concentration, but CO was decreased due to the increase of chemical reaction rate.

Assessment of $13{\sim}19%Cr$ Ferritic Oxide Dispersion Strengthened Steels for Fuel Cladding Applications

  • Lee, J.S.;Kim, I.S.;Kimura, A.;Choo, K.N.;Kim, B.G.;Choo, Y.S.;Kang, Y.H.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.911-912
    • /
    • 2004
  • 1. Cathodic hydrogen charging considerably reduced the tensile ductility of ODS steels and a 9Cr-2W RMS. The hydrogen embrittlement of ODS steels was strongly affected by specimen sampling orientation, showing significant embrittlement in the T-direction. This comes from the microstructural anisotropy caused by elongated grains of ODS steels in L-direction. 2. The ODS steels contained a higher concentration of hydrogen than 9Cr-2W RMS at the same cathodic charging condition, and the critical hydrogen concentration required to transition from ductile to brittle fracture was in the range of $10{\sim}12$ wppm, which approximately 10 times larger than that of a 9Cr-2W martensitic steel. 3. The ODS steels showed a typical ductile to brittle transition behavior and it strongly depended on the specimen sampling direction, namely L- and T-direction. In T-direction, the SP-DBTT was about 170 L, irrespective of the ODS materials, and L-direction showed a lower SP-DBTT than that of T-direction.

  • PDF

Direct Numerical Simulation of Mass Transfer in Turbulent new Around a Rotating Circular Cylinder ( I ) - At Sc=1670 - (회전하는 원형단면 실린더 주위의 난류유동 물질전달에 대한 직접수치모사 ( I ) - 높은 Schmidt 수에 대하여 -)

  • Hwang Jong-Yeon;Yang Kyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.7 s.238
    • /
    • pp.837-845
    • /
    • 2005
  • In this paper, an investigation on high-Schmidt number (Sc=1670) mass transfer in turbulent flow around a rotating circular cylinder is carried out by Direct Numerical Simulation. The concentration field is computed for three different values of low Reynolds number, namely 161, 348 and 623 based on the cylinder radius and friction velocity. Statistical study reveals that the thickness of Nernst diffusive layer is very small compared with that of viscous sub-layer in the case of high Sc mass transfer. Strong correlation of concentration field with streamwise and vertical velocity components is observed. However, that is not the case with the spanwise velocity component. Instantaneous concentration visualization reveals that the length scale of concentration fluctuation typically decreases as Reynolds number increases. Statistical correlation between Sherwood number and Reynolds number is consistent with other experiments currently available.