화력발전소의 미세먼지 배출특성 (Emission Characteristics of Fine Particles from Thermal Power Plants)

  • Park, Sooman;Lee, Gayoung
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권4호
    • /
    • pp.455-460
    • /
    • 2020
  • In order to identify the characteristics of fine particle emissions from thermal power plants, this study conducted measurement of the primary emission concentration of TPM, PM10 and PM2.5 according to Korea standard test method (ES 01301.1) and ISO 23210 method (KS I ISO 23210). Particulate matters were sampled in total 74 units of power plants such as 59 units of coal-fired power plants, 7 units of heavy oil power plants, 2 units of biomass power plant, and 6 units of liquid natural gas power plants. The average concentration of TPM, PM10, PM2.5 by fuel are 3.33 mg/m3, 3.01 mg/m3, 2.70 mg/m3 in coal-fired plant, 3.02 mg/m3, 2.99 mg/m3, 2.93 mg/m3 in heavy oil plant, 0.114 mg/m3, 0.046 mg/m3, 0.036 mg/m3 in LNG plant, respectively. These results of TPM, PM10 and PM2.5 were satisfied with the standards of fine dust emission allowance in all units of power plants, respectively. Also, this study evaluated the characteristics of fine particle emissions by conditions of power plants including generation sources, boiler types and operation years and calculated emission factors and then evaluated fine particle emissions by sources of electricity generation.

Distribution Characteristics of Dioxins in Marine Sediment from Busan Port in Korea

  • Jeong, Tae-Uk;Seo, Dong-Cheol;Jeong, Seung-Ryul;Song, Bok-Joo;Cho, Jeong-Gu;Yoo, Pyung-Jong;Kim, Gi-Gon;Cho, Ju-Sik;Heo, Jong-Soo
    • 한국토양비료학회지
    • /
    • 제45권1호
    • /
    • pp.107-111
    • /
    • 2012
  • Eight marine sediments from Busan port in Korea were annually analyzed to examine the concentration distribution of dioxins from 2006 to 2010. Yearly mean concentration of dioxins ranged from 186.3 to $383.3pg\;g^{-1}$ in real values and 5.087 to 8.541 pg-TEQ (Toxicity equivalency) based on dry weight of samples. The dioxin concentration at the site near fishing market was the highest concentration among all sampling sites. Also the dioxin concentration at the sites with various pollutant sources such as large ships, sewage influx and thermal power station as well as fishing market was higher than that of the sites without specific pollutant sources. Another main factor that affects the dioxin concentration is topography characteristics of the bay. The bay has relatively high dioxin concentration because of the lack of the pollutant diffusion. This study demonstrated that the dioxin concentration in the site with pollutant sources and the lack of the pollutant diffusion was relatively high as compared with the other sites. As a result of contribution ratio of dioxin congeners, OCDD (Octachlorodibenzodioxin) in all sites was major contributor in real value, in contrast, dioxin congeners in TEQ values were dominated by 2,3,4,7,8-PeCDF.

집광 열유속 측정과 모델링의 비교를 통한 집광 오차 평가 (Concentration Error Assessment by Comparison of Solar Flux Measurement and Modeling)

  • 채관교;윤환기;이현진;이성욱;김시석
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.82-90
    • /
    • 2013
  • Concentration errors critically affect the performance of solar concentrator, so their evaluation is important to the concentrated solar power technology. However, the evaluation is very challenging because error sources are various and not easy to measure individually. Therefore, the integrated effect of concentration errors is often more interesting and useful for large-scale applications. In the present work, we analytically investigate and classify various concentration error sources and then explain that the effect of various concentration errors can be represented in terms of a root mean square value of reflector surface slope error. We present an indirect approach to assessing the reflector surface slope error by comparing solar flux measurement data with modeling calculations. We apply the approach for solar furnaces with different thermal capacity and investigate its advantages and disadvantages.

창원지역 일부 환아에서 혈청 비타민 D의 주된 급원과 신체적 성장과의 관계 (The relationship between Physical Growth and Major Sources of Serum Vitamin D among Hospitalized Children of Changwon City)

  • 강혜영;허은실;이경혜
    • 대한지역사회영양학회지
    • /
    • 제20권3호
    • /
    • pp.197-207
    • /
    • 2015
  • Objectives: This study was conducted to investigate the effects of the sources of vitamin D (duration of exposure to sunlight, intake of major food sources for vitamin D or vitamin D supplements) on the serum 25-(OH) $D_3$ levels, and the physical growth of a child. Methods: Subjects were 296 children aged 1 to 5 years who visited S hospital located in Changwon City. Survey data collection was carried out by direct interview method, and the biochemical data were collected using hospital records. Results: The study subjects were divided into three groups according to their levels of serum 25-(OH) $D_3$ (deficient, relatively insufficient, sufficient) and their percentage were 48.3%, 44.3% and 7.4% respectively. The average concentration of serum 25-(OH) $D_3$ was $20.41{\pm}6.55ng/mL$, which was relatively insufficient. The average duration of exposure to sunlight was $58.86{\pm}49.18minutes/day$. A total score of vitamin D major food sources was 46.71 points (full marks 153), and the most frequently consumed food items were milk, eggs, and cheese. Thirty-four percent of the subjects took vitamin D supplements and their dose were $11.96{\mu}g/day$. Three vitamin D sources in sufficient group were higher than deficient or relatively insufficient group significantly. Intake of vitamin D supplements showed positive relation (+) and high explanation power ($R^2=0.288$) on serum 25-(OH) $D_3$ concentration, but intake of vitamin D major food sources (+) and the duration of exposure to sunlight (+) had a low explanation power ($R^2=0.068$). The relations between serum 25-(OH) $D_3$ concentration and physical growth (height and weight) were shown as negative (-), and their explanation powers were low as 7.3% and 5.9% respectively. Conclusions: This study results can be useful when discussing the intake standard of vitamin D and the effective intake method for children. In addition, it will be helpful to build the children's nutrition policy and to plan the nutrition education program to improve the vitamin D status in children.

PREDICTION OF THE TRITIUM CONCENTRATION IN THE SOIL WATER AFTER THE OPERATION OF WOLSONG TRITIUM REMOVAL FACILITY

  • CHOI HEUI-JOO;LEE HANSOO;SUH KYUNG SUK;KANG HEE SUK
    • Nuclear Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.385-390
    • /
    • 2005
  • The effect of the Wolsong Tritium Removal Facility on the change of tritium concentration in the soil water was assessed by introducing a dynamic compartment model. For the mathematical modeling, the tritium in the environment was thought to come from two different sources. Three global tritium cycling models were compared with the natural background concentration. The dynamic compartment model was used to model the behavior of the tritium from the nuclear power plants at the Wolsong site. The source term for the dynamic compartment model was calculated with the dry and wet deposition rates. The area around the Wolsong nuclear power plants was represented by the compartments. The mechanisms considered in deriving the transfer coefficients between the compartments were evaporation, runoff, infiltration, hydrodynamic dispersion, and groundwater flow. We predicted what the change of the tritium concentration around the Wolsong nuclear power plants would be after future operation of the tritium removal facility to show the applicability of the model. The results showed that the operation of the tritium removal facility would reduce the tritium concentration in topsoil water quickly.

Electrical Modeling of 10kW PEMFC

  • Lee, Jin-Mok;Park, Ga-Woo;Choi, Jae-Ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 추계학술대회 논문집
    • /
    • pp.193-195
    • /
    • 2008
  • As arising the cost and decreasing of gasoline and fossil fuel, renewable energy sources such as photovoltaics, wind and fuel cell have been interested. Among of them, PEM fuel cells are good energy sources to provide reliable power at steady state regardless of weather, time of day and location as long as the fuel and air are supplied, but they cannot respond to electrical load transients as fast as desired. This is mainly due to their slow internal electrochemical and thermodynamic responses. Therefore, to use the fuel cells with high efficiency, this paper finds characteristic curve and understand operation of PEMFC based on three theoretical approaches such as activation, ohmic and concentration and make the model using MATLAB. That result was compared with real system to certify.

  • PDF

PRO 분리막 및 모듈성능에 지지체가 미치는 영향 (The effect of backing layer for pro membranes and modules)

  • 한만재;전은주;심연주;이종화
    • 상하수도학회지
    • /
    • 제30권5호
    • /
    • pp.553-559
    • /
    • 2016
  • There has been increasing global interest in the environmental pollution problems produced by fossil fuel consumption and greenhouse gas emissions. In order to tackle these issues, new renewable energy such as solar, wind, bio gas, fuel cell and pressure retarded osmosis(PRO) have been developed extensively. Among these energy sources, PRO is one of the salinity gradient power generation methods. In PRO, energy is obtained by the osmotic pressure generated from the concentration difference between high and low concentration solutions separated by a semipermeable membrane. The development for high power density PRO membranes is imperative with the purpose of commercialization. This study investigates development of thin film composite PRO membrane and spiral wound module for high power density. Also, the influence of membrane backing layer on power density was identified, and the characteristic factors of PRO membranes was determined. Different backing layers were used to improve power density. As expected, the PRO membrane with more porous backing layer showed higher power density.

대단위배출원에서 기인한 입자상오염물질의 확산ㆍ추적을 통한 ISCST3모델과 수용모델의 비교연구 (The Study on the Comparison of the ISCST3 Model and Receptor Model by Dispersion Tracing of Particulate Matter from Large Scale Pollution Sources)

  • 전상기;이성철;박경선
    • 한국대기환경학회지
    • /
    • 제19권6호
    • /
    • pp.789-803
    • /
    • 2003
  • The purpose of this study is to compare the usefulness between Gaussian dispersion model and receptor model with the experimental result of the dispersion tracing of the particulate pollutants from Taean coal-fired power plants. For this purpose, the component analysis of the collected PM 10 samples was performed. In order to trace the pollution sources, factor analysis was done with the result of the component analysis. As a result of the correlativity analysis of the fifteen power plants' profiles offered by US EPA, the correlativity of No.11202 source profile showed highest rate up to 84.5%. Thus it was adopted as proper one and the contribution rate by each pollution source was calculated by Chemical Mass Balance (CMB)-8 model. The contribution rate, which was the effect rate of the power plants on each measuring point, were calculated with a range of 24∼52% and the standard error was below 0.9 $\mu\textrm{g}$/㎥. This indicates the selection of the source profile was appropriate. Also, the concentrations of each point were calculated by the ISCST3 which is suggested by US EPA as one of the regulatory Gaussian dispersion model. The calculation result showed that the predicted concentration was 50∼58 $\mu\textrm{g}$/㎥, comparing with the measured result of 9∼65 $\mu\textrm{g}$/㎥. It was found that the concentration calculated by ISCST3 was underpredicted. It was thought that the receptor model was more favorable than the Gaussian dispersion model in estimating the effect of the particulate matter on a certain receptive point.

저온 열원의 활용을 위한 흡수 발전/냉각 복합 사이클의 열적 해석 (Thermal Analysis of a Combined Absorption Cycle of Cogeneration of Power and Cooling for Use of Low Temperature Source)

  • 김경훈
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.413-420
    • /
    • 2011
  • Thermodynamic cycles using binary mixtures as working fluids offer a high potential for utilization of low-temperature heat sources. This paper presents a thermodynamic performance analysis of Goswami cycle which was recently suggested to produce power and cooling simultaneously and combines the Rankine cycle and absorption refrigeration cycle by using ammoniawater mixture as working fluid. Effects of the system parameters such as concentration of ammonia and turbine inlet pressure on the system are parametrically investigated. Results show that refrigeration capacity or thermal efficiency has an optimum value with respect to ammonia concentration as well as to turbine inlet pressure.

메탄올 농도에 따른 직접 메탄올 연료전지의 성능 해석 (Performance Characteristics of Direct Methanol Fuel Cell with Methanol Concentration)

  • 조창환;김용찬;장영수
    • 설비공학논문집
    • /
    • 제20권3호
    • /
    • pp.197-204
    • /
    • 2008
  • DMFC(Direct Methanol Fuel Cell) is one of promising candidates for power sources of small mobile IT devices like notebook, cell phone, and so on. Efficient operation of fuel cell system is very important for long-sustained power supply because of limited fuel tank size. It is necessary to investigate operation characteristics of fuel cell stack for optimal control of DMFC system. The generated voltage was modeled according to various operating condition; methanol concentration, stack temperature, and load current. It is inevitable for methanol solution at anode to cross over to cathode through MEA(membrane electrode assembly), which reduces the system efficiency and increases fuel consumption. In this study, optimal operation conditions are proposed by analyzing stack performance model, cross-over phenomenon, and system efficiency.