• Title/Summary/Keyword: Concentration measurement

Search Result 2,774, Processing Time 0.038 seconds

Analysis and Uncertainty Estimation of Zearalenone in Cereal-Based Products by LC-MS/MS (LC-MS/MS를 이용한 곡류가공품의 제랄레논 분석과 측정불확도 추정)

  • Choi, Eun Jung;Kang, Sung Tae;Jung, So Young;Shin, Jae Min;Jang, Min Su;Lee, Sang Me;Kim, Jung Hun;Chae, Young Zoo
    • Korean Journal of Food Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.658-665
    • /
    • 2012
  • A survey of zearalenone contamination was conducted on cereal-based products by using an immunoaffinity column with LC-MS/MS. The calibration curve showed good lineality, with correlation coefficients ($R^2$) of 0.999 in the concentration range from 1 to 250 ng/mL. The limits of detection and quantification were approximately $0.3{\mu}g/kg$ and $1.0{\mu}g/kg$, respectively. The recoveries in the barley tea, Misutgaru and snack ranged from 73.6-107.8%. Zearalenone was detected in 10 samples (11.2% incidence). The highest zearalenone contamination level was $29.7{\mu}g/kg$ in the Misutgaru. This survey was conducted with uncertainty of measurement. The expanded uncertainty for zearalenone was estimated to be $44.9{\pm}5.0{\mu}g/kg$ (k=2, 95% confidence level) and $128.7{\pm}7.9{\mu}g/kg$ (k=2, 95% confidence level) for barley tea, $30.7{\pm}5.8{\mu}g/kg$ (k=2, 95% confidence level) and $173.7{\pm}14.9{\mu}g/kg$ (k=2.26, 95% confidence level) for Misutgaru, and $37.2{\pm}7.4{\mu}g/kg$ (k=2.31, 95% confidence level) and $151.0{\pm}10.4{\mu}g/kg$ (k=2, 95% confidence level) snack at the level of $41.7{\mu}g/kg$ and $166.7{\mu}g/kg$, respectively.

On the Distensibility of the External Carotid Artery of the Rabbit (가토(家兎) 외경동맥(外經動脈)의 신장도(伸張度)에 대(對)하여)

  • Lee, Dong-Il;Choo, Young-Eun
    • The Korean Journal of Physiology
    • /
    • v.7 no.2
    • /
    • pp.49-58
    • /
    • 1973
  • The distensibility of the major arteries has been investigated extensively, but the value expressed as Young Modulus varies widely by the different schools of the investigators, the major reason undoubtedly being the difficulties encountered in the measurement. In the present study, an attempt was made to elucidate the distensibility of the external carotid artery of the rabbit, which was placed in saline immediately after removing from the apparently healthy, normal rabbit without anesthesia. The circular section strip and longitudinal section strip were made from the whole artery, and Young Modulus of the whole artery, circular section and longitudinal section strips was calculated from the length-tension curve of each sample. Also, the similar samples of the artery seperately obtained were placed in ATP solution in the concentration of 0.15 mM and 0.30 mM, and Young Modulus was similary calculated. Experiments were performed at 15,45 and 75 min after the artery was removed from the rabbit, and the results thus obtained are summarized as follows. 1) Young Modulus of the whole external carotid artery of the rabbit in saline was $4.74{\times}10^7dyne/cm^2$ at 15 min, but lower values were obtained at 45 and 75 min, Young Modulus being $4.62{\times}10^7dyne/cm^2\;and\;4.13{\times}10^7dyne/cm^2$, respectively. When the arterial samples were placed in ATP solutions, Young Modulus did not change much throughout the experiment, and lower Young Moduli were obtained in 0.30 mM ATP solution than in 0. 15 mM ATP solution. 2) Young Modulus Of the Circular Section Strip in Saline was $4.11{\times}10^7dyne/Cm^2,\;3.75{\times}10^7dyne/cm^2\;and\;3.90{\times}10^7dyne/cm^2,$ respectively, at 15, 45 and 75 min, the value at 15 min being the highest. However, when the strip was placed in ATP solutions, no appreciable change was observed throughout the experiment, and Young Moduli were lower in 0.30 mM ATP solution than in 0.15 mM ATP solution. 3) Young Modulus of the longitudinal section strip in saline was $2.12{\times}10^7dyne/cm^2,\;2.48{\times}10^7dyne/cm^2\;and\;2.46{\times}10^7dyne/cm^2$, respectively, at 15, 45 and 75 min, Young Modulus being slightly elevated in the latter part of the experiment. A similar tendency was observed when the strip was placed in ATP solutions.

  • PDF

A Study on Characteristics of Airborne Asbestos Concentrations at Demolition Sites and Surrounding Areas of Asbestos Containing Buildings in Seoul (서울시내 건축물 석면해체·제거 사업장 및 주변에서의 공기 중 석면농도 특성에 관한 연구)

  • Lee, Jinhyo;Lee, Suhyun;Kim, Jeongyeun;Kim, Jihui;Chung, Sooknye;Kim, Jina;Kim, Iksoo;Eo, Soomi;Jung, Kweon;Lee, Jinsook;Koo, Jayong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.6
    • /
    • pp.434-441
    • /
    • 2014
  • This study is purposed to measure airborne asbestos concentrations at demolition sites and surrounding areas of asbestos containing buildings in Seoul and examine whether the measurement results correspond with allowable exhaust standard for asbestos of the Asbestos Safety Control Act. The airborne asbestos concentrations for 37 sites were below the detection limit ($7fiber/mm^2$) in 101 (35%) out of 288 samples. The whole average airborne asbestos concentration in 37 sites was $0.003{\pm}0.002f/cc$(max 0.0013 f/cc) and almost the whole airborne asbestos concentrations were satisfied with allowable exhaust standard for asbestos, 0.01 f/cc, of the Asbestos Safety Control Act. So possibility of asbestos exposure is not yet a major concern at current levels for sites demolished of asbestos containing buildings in Seoul. Looking at each sampling point, the average airborne asbestos concentrations in boundary line of site, entrance of sanitation, around the workplace (in), around the workplace (out), negative pressure units, storage area for waste, outlet for waste and residential area of residents were respectively $0.002{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.004{\pm}0.002f/cc$, $0.005{\pm}0.004f/cc$, $0.005{\pm}0.003f/cc$ and $0.003{\pm}0.002f/cc$. As a result, all sampling points of study were satisfied with allowable exhaust standard for asbestos, 0.01 f/cc, of the Asbestos Safety Control Act.

In Vivo Preperation of Standard Reference Materials of Lead in Blood (생체내 혈중 납 표준물질의 제조)

  • Chung, Kyou-Chull;Choi, Ho-Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.863-873
    • /
    • 1995
  • This report describes a preperation and characterization of canine blood lead(Pb) standard reference material(SRM). Three adult beagle dogs(A, B, and C)were orally dosed with gelatin capsules containing $Pb(NO_3)_2$, equivalent to $10\sim80mg$ Pb/kg body weight. Blood was drawn 24 hours after the dose from the cephalic vein into lead free 500ml Pyrex beaker in which EDTA.K was contained as an anticoagulant. The amount of lead given to individual dog was varied arbitrarily. Three month later, 3 canine animals were orally dosed with lead secondarily to make mixed SRM(D1) which was mixed different concentrations of lead in bloods with A1, B1, and C1 in vitro. The SRMs for A, B, C, A1, B1, C1, and D1 were distributed 2ml each into more than 300 lead free bottles, and were stored in refregerator at $4^{\circ}C$. The amount of lead in canine whole blood samples were determined using a Varian 30A atomic absorption spectrophotometer(AAS) with a model GTA-96 graphite tube atomizer with D2 background correction and a Hitachi Z-8100 AAS with Zeeman background correction. The sensitivity and detection limits for lead determination of Varian 30A were $0.46{\mu}g/L,\;0.34{\mu}g/L,\;and\;0.56{\mu}g/L,\;0.14{\mu}g/L$ of Hitachi Z-8100, respectively. Day to day variations in determination of blood lead concentration in a certain sample were $31.11{\pm}1.36{\mu}g/100ml$ by Varian 30A, and $33.08{\pm}0.82{\mu}g/100ml$ by Hitachi Z-8100, showing the difference of 3% between the two results. At the blood lead concentrations of $56.31{\pm}1.98{\mu}g/100ml(A),\;40.89{\pm}0.80{\mu}g/100ml(B),\;59.01{\pm}1.38{\mu}g/100ml(C)$, the precisions of replicated measurements by AAS were 3.52%, 1.96%, and 2.34%, respectively. Coefficient variation(CV) of SRMs(A, B, and C) within a standard sample were ranged from 0.92% to 7.50%, and those between 5 standard samples were 1.21%, 2.64%, and 1.11%, respectively, showing inter-vial variation of $1{\mu}g/100ml$. Lead levels in SRMs during one month storage were unchanged. The overall recoveries were $89.6\sim100.4%,\;91.6\sim101.9%,\;90.3\sim100.0%$ for A, B, and C SRMs, means were $56.46{\pm}2.69{\mu}g/100ml,\;39.35{\pm}1.89{\mu}g/100ml,\;57.40{\pm}2.31{\mu}g/100ml$, and measurement ranges were$52.88{\pm}59.26{\mu}g/100ml,\;37.47{\pm}41.68{\mu}g/100ml,\;54.80{\pm}60.69{\mu}g/100ml$, respectively. Those results were laid within confidence limits values. The lead concentrations in the mixed sample(D1) stored over one month period were ranged from $32.76{\mu}g/100ml\;to\;33.54{\mu}g/100ml$, with CV ranging from 1.2% to 2.7%. The results were similiar to each of single samples(A1, B1, and C1) in respect of homogeneity and stability. Results of the mixed blood sample analysed after 1 month storage at $4^{\circ}C$ by four other laboratories(L1, L2, L3, L4) were similar with those of our laboratory($L5;31.18{\pm}0.24{\mu}g/100ml$, acceptable range by $CDC;25.18\sim37.18{\mu}g/100ml$), showing the concentrations of $25.91{\pm}1.19{\mu}g/100ml(L1),\;34.16{\pm}0.22{\mu}g/100ml(L2),\;35.68{\pm}0.85{\mu}g/100ml(L3),\;30.95{\pm}0.46{\mu}g/100ml(L4)$ in a each samples.

  • PDF

Prelaunch Study of Validation for the Geostationary Ocean Color Imager (GOCI) (정지궤도 해색탑재체(GOCI) 자료 검정을 위한 사전연구)

  • Ryu, Joo-Hyung;Moon, Jeong-Eon;Son, Young-Baek;Cho, Seong-Ick;Min, Jee-Eun;Yang, Chan-Su;Ahn, Yu-Hwan;Shim, Jae-Seol
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.2
    • /
    • pp.251-262
    • /
    • 2010
  • In order to provide quantitative control of the standard products of Geostationary Ocean Color Imager (GOCI), on-board radiometric correction, atmospheric correction, and bio-optical algorithm are obtained continuously by comprehensive and consistent calibration and validation procedures. The calibration/validation for radiometric, atmospheric, and bio-optical data of GOCI uses temperature, salinity, ocean optics, fluorescence, and turbidity data sets from buoy and platform systems, and periodic oceanic environmental data. For calibration and validation of GOCI, we compared radiometric data between in-situ measurement and HyperSAS data installed in the Ieodo ocean research station, and between HyperSAS and SeaWiFS radiance. HyperSAS data were slightly different in in-situ radiance and irradiance, but they did not have spectral shift in absorption bands. Although all radiance bands measured between HyperSAS and SeaWiFS had an average 25% error, the 11% absolute error was relatively lower when atmospheric correction bands were omitted. This error is related to the SeaWiFS standard atmospheric correction process. We have to consider and improve this error rate for calibration and validation of GOCI. A reference target site around Dokdo Island was used for studying calibration and validation of GOCI. In-situ ocean- and bio-optical data were collected during August and October, 2009. Reflectance spectra around Dokdo Island showed optical characteristic of Case-1 Water. Absorption spectra of chlorophyll, suspended matter, and dissolved organic matter also showed their spectral characteristics. MODIS Aqua-derived chlorophyll-a concentration was well correlated with in-situ fluorometer value, which installed in Dokdo buoy. As we strive to solv the problems of radiometric, atmospheric, and bio-optical correction, it is important to be able to progress and improve the future quality of calibration and validation of GOCI.

Assessment of Fertilizer Efficiency of Pharmaceutical Byproduct and Cosmetic Industry Wastewater Sludge as Raw Materials of Compost (제약업종 부산물 및 화장품 제조업 폐수처리오니의 비효검정)

  • Lim, Dong-Kyu;Kwon, Soon-Ik;Lee, Seung-Hwan;So, Kyu-Ho;Sung, Ki-Suk;Koh, Mun-Hwan
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.38 no.2
    • /
    • pp.108-117
    • /
    • 2005
  • Pharmaceutical byproduct sludge and cosmetic industry wastewater sludge can be used as a raw material of compost. Effects of three types of pharmaceutical byproduct sludge and one type of cosmetic industry wastewater sludge on soil properties and red pepper growth were investigated in a field based concrete pot ($2{\times}2m$). These sludges and pig manure ($5Mg\;ha^{-1}$, dry basis) were incorporated into the upper of loam soil 30 days prior to transplanting red pepper. Changes in soil properties and contents of heavy metals and toxic organic compounds in soil and plant were measured. And also plant growth measurement and bioassay of soil phytotoxicity were included. Contents of heavy metals were increased in the soils treated with the sludges. Plant growth in the sludge treatments were mostly inferior to that of NPK treatment, especially in early stage. Content of N in plant was lower in all sludge treatments at early and middle growth stages, and it was especially caused by characteristics and concentration of nitrogen and organic matter of sludges. Total yield of red pepper was highest in the NPK treatment and followed by pharmaceutical sludge 3, pig manure, pharmaceutical sludge 1, and pharmaceutical sludge 2, and the yield of cosmetic sludge treatment was considerably lower than others. HEM and PAHs contents in soil of cosmetic sludge treatment were $4.80mg\;kg^{-1}$ and $2,263.2{\mu}g\;kg^{-1}$, respectively. Root elongation of lettuce exposed to the water extract of soil treated with cosmetic sludge was about 20% of that found in the test with soil extract of non fertilization treatment. At present, raw materials of compost were authorized according to the contents of organic matter, heavy metals and product processing. Toxic organic compounds analysis and bioassay would be helpful for authorization and assessment of suitability of raw materials of compost.

A Study on the Characteristics of PM1.0 Chemical Components Using a Real-time Aerosol Mass Spectrometer (실시간 에어로졸 질량분석기를 이용한 PM1.0의 화학적성분의 특성에 관한 연구)

  • Park, Jinsoo;Choi, Jinsoo;Kim, Hyunjae;Oh, Jun;Sung, Minyoung;Ahn, Joonyoung;Lee, Sangbo;Kim, Jeongho
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.485-494
    • /
    • 2018
  • This study aims to identify the characteristics of oxidation and chemical composition of PM in winter season, 2017 at Incheon area. The mean concentration of air pollutants were $46{\pm}22{\mu}g/m^3-PM_{10}$, $29{\pm}18{\mu}g/m^3/-PM_{2.5}$, $5{\pm}3ppb-SO_2$, $0.56{\pm}0.24ppm-CO$, $21{\pm}13ppb-O_3$ and $28{\pm}17ppb-NO_2$, respectively. The dominant ion of the $PM_{1.0}$ chemical component were organic with $3.2{\mu}g/m^3$ and nitrate with $1.9{\mu}g/m^3$. The day and night variation of the $PM_{1.0}$ chemical components was higher in nighttime than those of daytime. The averaged nitrate oxidation rate (SOR) was 0.06 and sulfate oxidation rate was 0.11 during the field campaign. In the high mass loading period, nitrate oxidation rate (NOR) was up to 0.6 and also the nitrate in $PM_{1.0}$ was increased. The averaged ratio of $NO_x/SO_2$ was 8.7 and nitrate/sulfate was 3.1, respectively. In this results, the nitrate component in $PM_{1.0}$ was influenced by NOx from the stationary source as power plant and the mobile source around the measurement site.

A Study on the Application of Physical Soil Washing Technology at Lead-contaminated Shooting Range in a Closed Military Shooting Range Area (폐 공용화기사격장 내 납오염 사격장 군부지의 물리적 토양세척정화기술 적용성 연구)

  • Jung, Jaeyun;Jang, Yunyoung
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.5
    • /
    • pp.492-506
    • /
    • 2019
  • Heavy metal contaminants in the shooting range are mostly present in a warhead circle or a metal fragment present as a particle, these fine metal particles are weathered for a long period of time is very likely that the surface is present as an oxide or carbon oxide. In particular, lead which is a representative contaminant in the shooting range soil, is present as more fine particles because it increases the softness and is stretched well. Therefore, by physical washing experiment, we conducted a degree analysis, concentration of heavy metals by cubic diameter, composition analysis of metallic substances, and assessment of applicability of gravity, magnetism and floating selection. The experimental results FESEM analysis and the measurement results lead to the micro-balance was confirmed thatthe weight goes outless than the soil ofthe same size in a thinly sliced and side-shaped structure according to the dull characteristics it was confirmed that the high specific gravity applicability. In addition, the remediation efficiency evaluation results using a hydrocyclone applied to this showed a cumulative remediation efficiency of 71%,twice 80%, 3 times 91%. On the other hand, magnetic sifting showed a low efficiency of 17%,floating selection -35mesh (0.5mm)target soil showed a relatively high efficiency to 39% -10mesh (2mm) efficiency was only 16%. The target treatment diameter of soil washing should be 2mm to 0.075mm, which is applied to the actual equipment by adding an additional input classification, which would require management as additional installation costs and processes are constructed. As a result, it is found that the soilremediation of shooting range can be separately according to the size of the warhead. The size is larger than the gravel diameter to most 5.56mm, so it is possible to select a specific gravity using a high gravity. However, the contaminants present in the metal fragments were found to be processed by separating using a hydrocyclone of the soil washing according to the weight is less than the soil of the same particle size in a thinly fragmented structure.

Effect of SO2 on the Simultaneous Removal of Mercury and NOx over CuCl2-loaded V2O5-WO3/TiO2 SCR Catalysts (CuCl2가 담지된 V2O5-WO3/TiO2 SCR 촉매에 의한 수은 및 NOx 동시 제거에서 SO2의 영향)

  • Ham, Sung-Won
    • Clean Technology
    • /
    • v.28 no.1
    • /
    • pp.38-45
    • /
    • 2022
  • CuCl2-loaded V2O5-WO3/TiO2 catalyst showed excellent activity in the catalytic oxidation of elemental mercury to oxidized mercury even under SCR condition in the presence of NH3, which is well known to significantly inhibit the oxidation activity of elemental mercury by HCl. Moreover, it was confirmed that, when SO2 was present in the reaction gas together with HCl, excellent elemental mercury oxidation activity was maintained even though CuCl2 supported on the catalyst surface was converted to CuSO4. This is thought to be because not only HCl but also the SO4 component generated on the catalyst surface promotes the oxidation of elemental mercury. However, in the presence of SO2, the total mercury balance before and after the catalytic reaction was not matched, especially as the concentration of SO2 increased. In order to understand the cause of this, further studies are needed to investigate the effect of SO2 in the SnCl2 aqueous solution employed for mercury species analysis and the effect of sulfate ions generated on elemental mercury oxidation. It was confirmed that SO2 also promotes NOx removal activity, which is thought to be because the increase in acid sites by SO4 generated on the catalyst surface by SO2 facilitates NH3 adsorption. The composition change and structure of the components present on the catalyst surface under various reaction conditions were measured by XRD and XRF. These measurement results were presented as a rational explanation for the results that SO2 enhances the oxidation activity of elemental mercury and the NOx removal activity in this catalyst system.

Analysis of the mixing effect of the confluence by the difference in water temperature between the main stream and the tributary (본류와 지류의 수온 차에 의한 합류부 혼합 양상 분석)

  • Ahn, Seol Ha;Lee, Chang Hyun;Kim, Kyung Dong;Kim, Dong Su;Ryu, Si Wan;Kim, Young Do
    • Journal of Korea Water Resources Association
    • /
    • v.56 no.2
    • /
    • pp.103-113
    • /
    • 2023
  • The river confluence is a section in which two rivers with different topographical and hyrodynamic characteristics are combined into one, and it is a section in which rapid flow, inflow of sediments, and hydrological topographic changes occur. In the confluence section, the flow of fluid occurs due to the difference in density due to the type of material or temperature difference, which is called a density flow. It is necessary to accurately measure and observe the confluence section including a certain section of the main stream and tributaries in order to understand the mixing behavior of the water body caused by the density difference. A comprehensive analysis of this water mixture can be obtained by obtaining flow field and flow rate information, but there is a limit to understanding the mixing of water bodies with different physical properties and water quality characteristics of rivers flowing with stratigraphic flow. Therefore, this study attempts to grasp the density flow through the water temperature distribution in the confluence section. Among the extensive data of the river, vertical data and water surface data were acquired, and through this, the stratification phenomenon of the confluence was to be confirmed. It was intended to analyze the mixed pattern of the confluence by analyzing the water mixing pattern according to the water temperature difference using the vertical data obtained by measuring the repair volume by installing the ADCP on the side of the boat and measuring the real-time concentration using YSI. This study can supplement the analysis results of the existing water quality measurement in two dimensions. Based on the comparative analysis, it will be used to investigate the current status of stratified sections in the water layer and identify the mixing characteristics of the downstream section of the river.