• Title/Summary/Keyword: Concentration efficiency

Search Result 4,544, Processing Time 0.04 seconds

Evaluation of electrical energy consumption in UV/H2O2 advanced oxidation process for simultaneous removal of NO and SO2

  • Shahrestani, Masoumeh Moheb;Rahimi, Amir
    • Environmental Engineering Research
    • /
    • 제24권3호
    • /
    • pp.389-396
    • /
    • 2019
  • The electrical energy consumption (EEC) in removal of NO by a $UV/H_2O_2$ oxidation process was introduced and related to removal efficiency of this gas. The absorption-reaction of NO was conducted in a bubble column reactor in the presence of $SO_2$. The variation in NO removal efficiency was investigated for various process parameters including NO and $SO_2$ inlet concentrations, initial concentration of $H_2O_2$ solution and gas flow rate. EEC values were obtained in these different conditions. The removal efficiency was increased from about 22% to 54.7% when $H_2O_2$ concentration increased from 0.1 to 1.5 M, while EEC decreased by about 70%. However, further increase in $H_2O_2$ concentration, from 1.5 to 2, had no significant effect on NO absorption and EEC. An increase in NO inlet concentration, from 200 to 500 ppm, decreased its removal efficiency by about 10%. However, EEC increased from $2.9{\times}10^{-2}$ to $3.9{\times}10^{-2}kWh/m^3$. Results also revealed that the presence of $SO_2$ had negative effect on NO removal percentage and EEC values. Some experiments were conducted to investigate the effect of $H_2O_2$ solution pH. The changing of pH of oxidation-absorption medium in the ranges between 3 to 10, had positive and negative effects on removal efficiency depending on pH value.

수산물 가공폐수내 염분농도가 고율 혐기성 소화에 미치는 영향 (Effect of the Salt Concentration in Seafood Wastewater on the High-Rate Anaerobic Digestion)

  • 최용범;한동준;이해승;권재혁
    • 대한환경공학회지
    • /
    • 제35권10호
    • /
    • pp.730-736
    • /
    • 2013
  • 본 논문은 수산물가공 폐수내 염분농도가 고율 혐기성 소화공정에 미치는 영향을 파악하고자 수행되었다. HRT 6 hr 이상에서 TCODcr의 제거효율은 81.1~90.7%로 조사되어, 수산물 가공폐수 처리를 위한 최적 HRT는 6 hr 이상으로 조사되었다. 유기물 부하 7.83~17.37 $kgTCODcr/m^3$/day$에서 TCODcr 제거당 메탄 발생량은 0.23~0.38 $m^3CH_4/kgCODrem.$으로 STP 상태의 이론적 메탄가스 발생량 $0.35m^3CH_4/kgTCODrem$.과 유사하게 조사되었다. 운전기간 동안 biogas내 메탄 함량은 70.1~76.8%로 유입부하 변동에 거의 영향을 받지 않았다. 염분농도에 따른 혐기성 소화효율 검토결과, $4,000mgCl^-/L$ 이하에서 TCODcr의 제거효율은 83.4~89.2%로, $5,000mgCl^-/L$에서는 70% 중반의 제거효율을 나타내, 안정적인 처리효율을 위해서는 $4,000mgCl^-/L$ 이하로 유지하여야 한다. biogas내 메탄함량은 $3,000mgCl^-/L$ 이하에서는 64.7~73.3%로 조사되었으나 $4,000mgCl^-/L$ 이상에서는 50.1~56.9%로 염분농도가 증가할수록 감소하였다.

Simultaneous Removal of Hydrogen Sulfide and Ammonia Using Thiobacillus sp. IW in a Three-Phase Fluidized-Bed Bioreactor

  • Kum, Sung-Hoon;Oh, Kwang-Joong;Moon, Jong-Hae;Kim, Dong-Uk
    • Journal of Microbiology and Biotechnology
    • /
    • 제10권3호
    • /
    • pp.419-422
    • /
    • 2000
  • A three-phase fluidized-bed bioreactor including Thiobacillus sp. IW was tested to remove H_2S and $NH_3$ simultaneously. The inlet $H_2S$ was oxidized to $SO_4^{2-}$ by Thiobacillus sp. IW, and the $NH_3$ reacted with the $SO_4^{2-}$ to form $(NH_4)_2SO_4$. The removal efficiency of $H_2S$ was 98.4-99.9% for an inlet concentration of 36-730 ppm and that of $NH_3$ was 60.2-99.2% for an inlet concentration of 45-412 ppm. The removal efficiency of $NH_3$ was reduced when the inlet loading rate of $NH_3$ was increased above 10 mg/l/h. When the bioreactor was operated for 25 days with a lower inlet concentration of $NH_3$ compared with the of $H_2S$, the bioreactor exhibited an excellent performance with a stable pH, dissolved oxygen content, and cell concentration.

  • PDF

튜브형 전극을 이용한 전기화학적 산화에 의한 질소제거에 관한 연구 (Nitrogen Removal by Electrochemical Oxidation Using the Tube Type Electrode)

  • 조재준;정종식;이재복
    • 상하수도학회지
    • /
    • 제18권5호
    • /
    • pp.580-587
    • /
    • 2004
  • The objective of this research is to investigate the electrochemical oxidation process for nitrogen removal in wastewater involving chloride ion and nitrogen compounds. The process experiment of electrochemical oxidation was conducted by using the stainless steel tube type reactor and the $Ti/IrO_2$ as anode. Free chlorine production and current efficiency variation for total nitrogen removal was compared depending on whether electrolyte is added, and the nitrogen type distribution under an operating condition. When chloride was added as electrolyte, it was found that production of free chlorine increased and the concentration of the chloride decreased as retention time passed. The concentration of chloride in influent decreased from 1,660 to 1,198 mg/L at the current density of $6.7A/dm^2$, while concentration of free chlorine increased to 132 mg/L. Current efficiency in removal of ammonium nitrogen was increased when chloride was dosed as electrolyte. It was observed that ammonium nitrogen was oxidized to nitrite and nitrate through electrochemical oxidation and that the concentration of total nitrogen in influent was reduced from 22.58 to 4.00 mg/L at the short retention time of 168 seconds through the electrochemical oxidation of nitrogen.

초음파 발생 미스트를 이용한 TiO2 광촉매 시스템에서의 가스상 톨루엔 제거 (Removal of Gaseous Toluene Using a TiO2 Photocatalytic System with Mist Generated by Ultrasonic Atomization)

  • 최민석;한세현;장성찬;정용원
    • 한국대기환경학회지
    • /
    • 제25권3호
    • /
    • pp.211-218
    • /
    • 2009
  • Feasibility study of using $Ti0_2$ mist generated by ultrasonic atomization for photocatalytic degradation of gaseous toluene was attempted in this study. For this, the photocatalytic reactor consisting of mist generator and photo-reactor was designed. Most of experimental results showed that steady state reached about 30 minutes after the start of experiments. The effects of $Ti0_2$ concentration, toluene concentration, and UV wavelength on toluene removal ratio were investigated. It was found that the highest removal efficiency was obtained when $Ti0_2$ concentration was 0.6 g/L in slurry. At this condition, it was found that the toluene removal efficiency increased as toluene concentration in feed decreased. In order to investigate the effect of UV wavelength, experiments were carried out using three UV lamps with different UV wavelength. The results showed that the highest removal efficiency was achieved when the lamp with the shortest wavelength were employed.

유동층 생물막 반응기를 이용한 고농도 질산성 폐수의 탈질화에 관한 연구 (The High Rate Denitrification of Nitric Acid Wastewater in a Fluidized Bed Biofilm Reactor)

  • 신승훈;김민수;박동일;안재동;장인용
    • 한국환경보건학회지
    • /
    • 제23권1호
    • /
    • pp.95-104
    • /
    • 1997
  • The objectives of this study are to investigate the effect of media on the removal efficiency of nitrate-nitrogen and the biofilm thickness in the fluidized bed biofilm reactor(FBBR) used for the high rate denitrification of nitric acid wastewater. Granular activated carbon(GAC) of 1.274 mm diameter and sand of 0.455 mm diameter were used as the media in the FBBR of 0.05 m diameter and 1.5 m height. As the nitrate-nitrogen concentration of the influent was increased stepwise from 600 to 4800 mg/l, the nitrate- and nitrite-nitrogen concentration of the effluent, biofilm thickness and biofilm dry density were measured to study the effects of media on the denitrification efficiency. The biofilm thickness increased with the substrate loading rate, and the biofilm dry density decreased with the increase of the biofilm thickness. At the influent nitrate-nitrogen concentration of 2400 mg/l, the removal efficiency in the FBBR with GAC was 88%, while that in the FBBR with sand was 99.6%. The biofilm in the FBBR with GAC was so thick, 754.9 $\mu$m, as to increase the mass transfer resistance, compared to that, 143.7 $\mu$m, in the FBBR with sand. The maximum specific denitrification rate in the FBBR with GAC was 15.0 kg-N/m$^3\cdot$ day, while that in the FBBR with sand was 18.0 kg-N/m$^3\cdot$ day. The biomass concentration in the FBBR with sand exhibited the high value 37 kg/m$^3$.

  • PDF

100 MWe급 순산소연소 발전소 보일러계통 공정설계 및 운전변수 민감도 예측 (100 MWe Oxyfuel Power Plant Boiler System Process Design and Operation Parameters Sensitivity Analysis)

  • 백세현;고성호
    • 한국연소학회지
    • /
    • 제18권4호
    • /
    • pp.1-11
    • /
    • 2013
  • The oxy-fuel combustion is $CO_2$ capture technology that uses mixture of pure $O_2$ and recirculated exhaust as oxidizer. Currently some Oxy-fuel power plants demonstration project is underway in worldwide. Meanwhile research project for converting 125 MWe Young-Dong power plant to 100 MWe oxy-fuel power plants is progress. In this paper, 1 D process analytical approach was applied for conducting process design and operating parameters sensitivity analysis for oxy-fuel combustion of Young-Dong power plant. As a result, appropriate gas recirculation rates was 74.3% that in order to maintain normal rating superheater, reheater steam temperature and boiler heat transfer patterns. And boiler efficiency 85.0%, CPU inlet $CO_2$ mole concentration 71.34% was predicted for retrofitted boiler. The oxygen concentration in the secondary recycle gas is predicted as 27.1%. Meanwhile the oxygen concentration 22.4% and moisture concentration 5.3% predicted for primary recycle gas. As the primary and secondary gas recirculation increases, then heat absorption of the reheater is tends to increases whereas superheater side is decreased, and also the efficiency is tends to decrease, according to results of sensitivity analysis for operating parameters. In addition, the ambient air ingression have a tendency to lead to decline of efficiency for boiler as well as decline of $CO_2$ purity of CPU inlet.

Ammonium and Nitrate Uptake and Utilization Efficiency of Rice varieties as Affected by Different N-Concentrations

  • Choi Kyung-Jin;Swiader John M.
    • 한국작물학회지
    • /
    • 제50권1호
    • /
    • pp.22-27
    • /
    • 2005
  • To find out the optimum mixture ratio of ammonium and nitrate on rice plant, 4 rice varieties were examined during 14days after transplanting in hydroponics with the different ratio of ammonium to nitrate(100 : 0, 75: 25,50: 50, 25: 75 and 0: 100). The highest N uptake from solution and the maximum plant dry weight were $60\~70\%$ ammonium and $30\~40\%$ nitrate mixture treatment both in Japonica and Tongil type rice plants. And with the same varieties N-uptake and N use-efficiency were compared between 10.0 mM and 1.0 mM nitrogen using $70\%$ ammonium and $30\%$ nitrate for 24 days after transplanting. Rice plants absorbed more nitrogen$(131\~145\%)$ in 10.0mM than 1.0mM treatment but accumulated N in rice plants were almost the same in both treatment. Among the tested rice cultivars, dry matter production and total accumulative nitrogen in rice plants were much high in Tongil type than japonica type rice cultivars. N-recovery ratios of rice plants from uptake N were $90.8-99.0\%$ in low concentration N solution(1.0 mM), but $69.4-81.7\%$ were observed in high concentration N solution(10.0 mM). It means that suppling low concentration N steadily will be better to prevent loss of N without reducing of growth in rice plants.

열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향 (An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe)

  • 최우석;박이동;김철주;황영규
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1995년도 춘계학술발표회 초록집
    • /
    • pp.69-76
    • /
    • 1995
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. Therefore Arrangement of heating pad affects thermal flow and thermal storage efficiency. So, if effective arrangement is decided for condition of constant number of heating pad, the more rapid thermal flow effect and higher thermal storage efficiency is obtainable by active heat transfer. In this experiments, number of heating pad is ranged from three, five and nine, and when number of heating pad is constant, arrangement are two types of concentration-type and dispersion-type. As a result, for the case of concentration-type of heating pad, strong entrainment take place in horizontal thermal storage tank with heat pipe by active heat transfer and in the constant number of heating pad, the concentration-type has the higher efficiency with about 5∼6% than the dispersion-type. Therefore, when heating pad is equipted to horizontal thermal storage tank with heat pipe, concentration-type of heating pad is an efficient design in constant number. of heating pad.

  • PDF

Design of a Fresnel Lens for a Solar End-pumped Solid-state Laser

  • Ou, Mingyu;Hu, Pian;Lan, Lanling;Liu, Yan;Zhou, Jun;Shi, Xiaotao
    • Current Optics and Photonics
    • /
    • 제4권5호
    • /
    • pp.441-445
    • /
    • 2020
  • A novel design for a Fresnel lens for a solar end-pumped laser is demonstrated in this paper. The new hybrid Fresnel lens includes two parts, inner and outer. The inner part is a twice-total-internal-reflection and vertical-transmission lens. The outer part is a once-total-reflection and vertical-transmission lens. The radius of the Fresnel lens is 600 mm, and its focal length is 750 mm. The concentrating performance of the Fresnel lens is examined using TracePro. The results show that the concentration efficiency has been greatly improved. The total concentration efficiency of the hybrid Fresnel lens reaches 73.2% when the radius of the laser rod is 3 mm. This design can simplify the concentration system of a solar end-pumped solid-state laser.