• Title/Summary/Keyword: Concentration efficiency

Search Result 4,544, Processing Time 0.029 seconds

Numerical Investigation of the Discharge Efficiency of a Vanadium Redox Flow Battery with Varying Temperature and Ion Concentration (온도와 이온농도의 변화에 대한 바나듐 레독스 플로우 배터리의 방전 효율에 관한 수치해석)

  • Lee, Jonghyeon;Park, Heesung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.12
    • /
    • pp.769-776
    • /
    • 2016
  • In this study, a numerical simulation of a vanadium redox flow battery was investigated for reactions involving an electrochemical species using comprehensive conservation laws and a kinetic model. For a 3-D geometry of the cell, the distributions of electric potential, vanadium concentration, overpotential, and ohmic loss were calculated. The cell temperature and initial vanadium ion concentration were set as variables. The voltage and electrochemical loss were calculated for each variable. The effects of each variable's impact on the electrochemical performance of a vanadium redox flow battery was numerically analyzed using the calculated overpotential in the electrode and the ohmic loss in the electrolyte phase. The cell temperature increased from $20^{\circ}C$ to $80^{\circ}C$ when the voltage efficiency decreased from 89.34% to 87.29%. The voltage efficiency increased from 88.65% to 89.25% when the vanadium concentration was changed from $1500mol/m^3$ to $3000mol/m^3$.

Estimation of Particle Mass Concentration from Lidar Measurement (라이다 관측자료를 이용한 미세먼지 농도 산정)

  • Kim, Man-Hae;Yeo, Huidong;Sugimoto, Nobuo;Lim, Han-Cheol;Lee, Chul-Kyu;Heo, Bok-Haeng;Yu, Yung-Suk;Sohn, Byung-Ju;Yoon, Soon-Chang;Kim, Sang-Woo
    • Atmosphere
    • /
    • v.25 no.1
    • /
    • pp.169-177
    • /
    • 2015
  • Vertical distribution of particle mass concentrations was estimated from 8-year elastic-backscatter lidar and sky radiometer data, and from ground-level PM10 concentrations measured in Seoul. Lidar ratio and mass extinction efficiency were determined from aerosol optical depth (AOD) and ground-level PM10 concentrations, which were used as constraints to estimate particle mass concentration. The mean lidar ratio (with standard deviation) and mass extinction efficiency for the entire 8-year study period were $60.44{\pm}23.17$ sr and $3.69{\pm}3.00m^2g^{-1}$, respectively. The lidar ratio did not vary significantly with the ${\AA}ngstr{\ddot{o}}m$ exponent (less than ${\pm}10%$); however, the mass extinction efficiency decreases to $1.82{\pm}1.67m^2g^{-1}$ (51% less than the mean value) when the ${\AA}ngstr{\ddot{o}}m$ exponent is less than 0.5. This result implies that the particle mass concentration from lidar measurements can be underestimated for dust events. Seasonal variation of the particle mass concentration estimated from lidar measurements for the boundary layer, was quite different from ground-level PM10 measurements. This can be attributable to an inhomogeneous vertical distribution of aerosol in the boundary layer.

A Study on Characteristics of NOx and Ozone by Plasma Reaction (Plasma반응에 의한 NOx와 Ozone의 특성에 관한 연구)

  • Choi Jae Wook;Yamaguma Mizuki;Choi Jae Jin
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.2 s.10
    • /
    • pp.1-6
    • /
    • 2000
  • In this experiment, we made the plasma reactor which adhere needle electrode in order to treat safely an NOx which was included in the gas. Also we experimently investigated characteristics of equipment and inspected efficiency. As a reaction gas, by using mixture gas of $NO/N_2$ and $N_2/O_2$, we setted up initial NO concentration and gas flow rate was set at 2 ${\iota}$/min. As a reaction characteristics of NOx, when discharge input power was high, NO concentration decreased and when the oxygen concentration increased, the NO decomposition was easy and decomposition energy efficiency was high. Also in case that NO concentration increased, NO decomposition energy efficiency was high but decomposition rate was low. The characteristics of ozone, when discharge input power was high, ozone increased and when $NO/N_2$ concentration increased, the ozone decreased.

  • PDF

A Study on the Phenomena of Dust Removal by the Layout Changes in the Turbulent Type Clean Room (난류형 클린룸내의 Layout 변화에 따른 분진제거 특성에 관한 연구)

  • Kim, Yeon-Hee;Kim, Hong
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.46-52
    • /
    • 2006
  • The purpose of this paper is to investigate the removal efficiency of fine dusts as the configuration condition of machinery and equipments in Clean Room and to analyze the flowing behaviors of fine dusts as the layout of Clean Room. The layout of the Clean Room was classified into side layout type, 2 center line type and center concentration type layout, and the flow rates used in this research were 0.22m/s, 0.44m/s and 0.80m/s. Dust removal efficiency as layout change was decreased 37% for side layout type, 31% for 2 center line type and 20% for center concentration type layout at the flow rate of 0.22m/s, compared with the state without machinery and equipments in Clean Room. The efficiency was decreased 42% for side layout type, 22% for 2 center line type and 8% for center concentration type layout at the flow rate of 0.44m/s, and decreased 20% for side layout type, 18% for 2 center line type and 10% for center concentration type layout at the flow rate of 0.80m/s. According to the result of dust removal behavior, $0.3{\mu}m,\;1{\mu}m\;and\;3{\mu}m$ dust except for $5{\mu}m$ showed the higher change of the behavior in side layout type than in center concentration type layout due to the change of air flow. It was confirmed that removal behavior depends on the layout of machinery and equipments as the dust size decreases.

Investigation of Nickel Removal from Heavy Metal Containing Industrial Wastewater by Electrocoagulation Method

  • Baybars Ali, Fil;Cansu, Elgun;Sevim Alya, Cihan;Sermin, Gunaslan;Alper Erdem, Yilmaz
    • Journal of Electrochemical Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.424-430
    • /
    • 2022
  • In the study, Ni2+ (nickel) removal from synthetically prepared wastewater by electrocoagulation method, which is one of the electrochemical treatment processes, was investigated and parameters such as current density, pH, mixing speed, initial Ni2+ concentration, supporting electrolyte type and concentration were determined to determine Ni2+ removal efficiencies effects were studied. Experiment conditions during 30 minutes of electrolysis; the current density was determined as 0.95 mA/cm2, the initial pH of the wastewater was 6, the mixing speed was 150 rpm, and the initial nickel concentration was 250 mg/L. The Ni2+ removal efficiency was obtained as 75.99% under the determined experimental conditions, while the energy consumption was calculated as 3.15 kW-h/m3. In the experiments, it was observed that the type and concentration of the supporting electrolyte did not have a significant effect on the Ni2+ removal efficiency. In the trials where the effect of the support electrolyte concentration was examined, the Ni2+ removal efficiency was 75.99% in the wastewater environment without the supporting electrolyte, while the Ni2+ removal efficiency was 81.55% when 7.5 mmol/L NaCl was used after the 30-minute reaction, and the energy consumption was 2.15 kW-h/m3 obtained as. As a result of the studies, it was concluded that the electrocoagulation process can be applied in the treatment of wastewater containing Ni2+.

Radon Removal Efficiency of Activated Carbon Filter from Coconut (코코넛 기반 활성탄 필터의 라돈 제거 효율)

  • Yun-Jin Ahn;Gi-Sub Kim;Tae-Hwan Kim;Sang-Rok Kim
    • Journal of radiological science and technology
    • /
    • v.46 no.2
    • /
    • pp.141-149
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences plans to produce 225Ac, a therapeutic radio-pharmaceutical for precision oncology, such as prostate cancer. Radon, a radioactive gas, is generated by radium, the target material for producing 225Ac. The radon concentration is expected to be about 2000 Bq·m-3. High-concentration radon-generating facilities must meet radioactive isotope emission standards by lowering the radon concentration. However, most existing studies concerning radon removal using activated carbon filters measured radon levels at concentrations lower than 1000 Bq·m-3. This study measured 222Rn removal of coconut-based activated carbon filter under a high radon concentration of about 2000 Bq·m-3. The 222Rn removal efficiency of activated carbon impregnated with triethylenediamine was also measured. As a result, the 222Rn removal amount of the activated carbon filter showed sufficient removal efficiency in a 222Rn concentration environment of about 2000 Bq·m-3. In addition, despite an expectation of low radon reduction efficiency of Triethylenediamine-impregnated activated carbon, it was difficult to confirm a significant difference in the results. Therefore, it is considered that activated carbon can be used as a radioisotope exhaust filter regardless of whether or not Triethylenediamine is impregnated. The results of this study are expected to be used as primary data when building an air purification system for radiation safety management in facilities with radon concentrations of about 2000 Bq·m-3.

Effect of Current Density and Electroosmotic Phenomena on the Desalination Performance of the Electrodialysis Process (전류밀도와 전기삼투 현상이 전기투석 공정의 탈염성능에 미치는 영향)

  • Eun-Seo Cheon;Jae-Hwan Choi
    • Applied Chemistry for Engineering
    • /
    • v.34 no.3
    • /
    • pp.272-278
    • /
    • 2023
  • In this study, we analyzed the effects of current density and electroosmotic phenomena on the desalination performance of electrodialysis (ED). We conducted ED experiments under constant voltage conditions, changing the concentration of the concentrate solution from 10 to 200 g/L. During the ED operation, we measured the current density and charge supplied to the stack, the concentration of the diluted and concentrated solutions, and the amount of water transported by electroosmosis to analyze desalination performance. As the concentration of the concentrated solution increased, the selectivity of the ion exchange membrane decreased, resulting in a decrease in current efficiency. Moreover, the current efficiency was found to be influenced by the current density supplied. When the current density exceeded 15 mA/cm2, back diffusion of ions was suppressed, leading to an increase in current efficiency. We also investigated the specific water transport by electroosmosis during the ED operation. We found that the amount of water transported increased proportionally to the concentration ratio of the concentrated and diluted solutions. When the concentration ratio exceeded 100, the specific water transport rapidly increased due to osmotic pressure, making it challenging to obtain a concentrated solution greater than 200 g/L.

Removal of Benzene in Solution by using the Bio-carrier with Dead Bacillus drentensis sp. and Polysulfone (Bacillus drentensis sp. 사균과 polysulfone으로 이루어진 미생물담체를 이용한 수용액 내 벤젠 제거)

  • Park, Sanghee;Lee, Minhee
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.46-56
    • /
    • 2013
  • Laboratory scale experiments to remove benzene in solution by using the bio-carrier composed of dead biomass have been performed. The immobilized bio-carrier with dead Bacillus drentensis sp. and polysulfone was manufactured as the biosorbent. Batch sorption experiments were performed with bio-carriers having various quantities of biomass and then, their removal efficiencies and uptake capacities were calculated. From results of batch experiments, 98.0% of the initial benzene (1 mg/L) in 1 liter of solution was removed by using 40 g of immobilized bio-carrier containing 5% biomass within 1 hour and the biosorption reaction reached in equilibrium within 2 hours. Benzene removal efficiency slightly increased (99.0 to $99.4%{\pm}0.05$) as the temperature increased from 15 to $35^{\circ}C$, suggesting that the temperature rarely affects on the removal efficiency of the bio-carrier. The removal efficiency changed under the different initial benzene concentration in solution and benzene removal efficiency of the bio-carrier increased with the increase of the initial benzene concentration (0.001 to 10 mg/L). More than 99.0% of benzene was removed from solution when the initial benzene concentration ranged from 1 to 10 mg/L. From results of fitting process for batch experimental data to Langmuir and Freundlich isotherms, the removal isotherms of benzene were more well fitted to Freundlich model ($r^2$=0.9242) rather than Langmuir model ($r^2$=0.7453). From the column experiment, the benzene removal efficiency maintained over 99.0% until 420 pore volumes of benzene solution (initial benzene concentration: 1 mg/L) were injected in the column packed with bio-carriers, investigating that the immobilized carrier containing Bacillus drentensis sp. and polysulfone is the outstanding biosorbent to remove benzene in solution.

The Effect of $PtCl_4$ Concentration on Dye-Sensitized Solar Cell Efficiency ($PtCl_4$ 농도에 따른 염료감응형 태양전지의 효율 변화)

  • Seo, Hyun-Seung;Park, Mi-Ju;Choi, Eun-Chang;Lee, Sung-Uk;Kim, Hyung-Jin;Hong, Byung-You
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.435-436
    • /
    • 2008
  • Dye-sensitized Solar Cells(DSSCs) which convert incident sun light into electricity were expected to overcome global warming and depletion of fossil fuels. And it is one of study that is lately getting into the spotlight because manufacturing method is more simple and inexpensive than existing silicon solar cells. In this respect, DSSCs are in the limelight as the next generation solar cells. DSSCs are generally composed of a dye-modified $TiO_2$ photoelectrode, a Pt counter electrode, and an electrolytes containing a redox couple$(I^-/I_3^-)$. Among these elements, pt electrode were prepared by applying electric potential to FTO substrate in the $H_2PtCl_6$ solution. In this study, we report the solar cell efficiency depending on $PtCl_4$ concentration change. $PtCl_4$ concentration was 1mM, 5mM, 10mM, and 20mM, and adhered on FTO glass substrate by sintering process. When applied each $PtCl_4$ counter electrode on DSSC, the best efficiency was found at 10mM of $PtCl_4$ concentration. The catalyst promotes the movement of electron from the counter electrode to the electrolyte the higher the molarity, the better the efficiency. However, in case of 20mM, it is estimated that over-deposited $PtCl_4$ tends to restrict the movement of electron due to its bundle formation.

  • PDF

Effect of Biofilter on Reducing Malodor Emission (악취 발산감소를 위한 필터의 이용 효과)

  • 김원영;정광화;노진식;김원호;전병수;류호현;전영륜
    • Journal of Animal Environmental Science
    • /
    • v.4 no.2
    • /
    • pp.161-166
    • /
    • 1998
  • Controlling malodor originating from livestock feces has become a major issue, due to its influence on the health of man and livestock, together with its influences on atmospheric pollution. In this study, Five types of biofilters filled with saw-dust, night soil, fermented compost, leaf mold and a mixture(a compound of night soil, fermented compost and leaf mold at the same rates, respectively) were manufactured and tested. To study the effect of the biofilter on reducing malodor in a composting facility and swine building, a pilot scale composting facility enclosed with polyethylene film was constructed. Swine feces was composted in the facility and malodorous gas generated from the decomposition of organic matter in the feces was gathered by vacuum pump. Each biofilter achieved 87∼96% NH3 removal efficiency. This performance was maintained throughout 10 days of operation. The highest NH3 removal efficiency was achieved by leaf mold on the first day of operation period. It reduced the concentration of NH3 by about 96%. Night soil and fermented compost showed nearly equal performance of 93 to 94% for 10 days from the beginning of operation. The mixture achieved the lowest NH3 removal efficiency. It reduced NH3 concentration by about 89∼94% for 10 days from the beginning of operation. However NH3 removal efficiency of each biofilter declined with the passage of operational time. After 30 days from the beginning of operation, NH3 removal efficiency of each biofilter of each biofilter was below 60%, respectively. The concentration of H2S and CH3-SH originating from compost were equal to or less than 5mg/l and 3mg/l, respectively. After passing throughout the biofilter, the concentration of H2S and CH3-SH were not detected.

  • PDF