• 제목/요약/키워드: Concentration Loads

검색결과 361건 처리시간 0.024초

SWAT 모형을 활용한 유황별 비점오염 저감 효율 분석 - 달천 유역을 대상으로 - (Analysis of Efficiency of Pollution Reduction Scenarios by Flow Regime Using SWAT Model - A case study for Dalcheon Basin -)

  • 김수홍;홍지영;박운지;김종건;임경재
    • 한국물환경학회지
    • /
    • 제37권6호
    • /
    • pp.469-482
    • /
    • 2021
  • The recent climate change and urbanization have seen an increase in runoff and pollutant loads, and consequently significant negative water pollution. The characteristics of the pollutant loads vary among the different flow regime depending on their source and transport mechanism, However, pollutant load reduction based on flow regime perspectives has not been investigated thoroughly. Therefore, it is necessary to analyze the effects of concentration on pollutant load characteristics and reductions from each flow regime to develop efficient pollution management. As non-point pollutants continuously increase due to the increase in impervious area, efficient management is necessary. Therefore, in this study, 1) the characteristics of pollutant sources were analyzed at the Dalcheon Basin, 2) reduction of nonpoint pollution, and 3) reduction efficiency for flow regimes were analyzed. By analyzing the characteristics of the Dalcheon Basin, a reduction efficiency scenario for each pollutant source was constructed. The efficiency analysis showed 0.06% to 5.62% for the living scenario, 0.09 to 24.62% for the livestock scenario, 0.17% to 12.81% for the industry scenario, 9.45% to 38.45% for the land scenario, and 9.8% to 39.2% for the composite scenario. Therefore, various pollution reduction scenarios, taking into account the characteristics of pollutants and flow regime characteristics, can contribute to the development of efficient measurements to improve water quality at various flow regime perspectives in the Dalcheon Basin.

동진강 유역의 오염부하량 평가 (Assessment of Pollutant Loads in the Dongjin River)

  • 이경보;김종천;김종구;이덕배;박찬원;김재덕
    • 한국환경농학회지
    • /
    • 제24권2호
    • /
    • pp.91-97
    • /
    • 2005
  • 동진강 수질관리 대안을 제시하고자 점 및 비점 오염원으로부터 발생, 배출, 유달부하량을 평가하였다. 용호 덕천천 유역은 BOD의 평균농도가 4.44 mg $L^{-1}$로 동진강 유역에서 가장 높았으며, T-N의 농도는 7.44 mg $L^{-1}$를 나타냈다. 정읍천 유역은 BOD의 평균농도가 2.29 mg $L^{-1}$, T-N의 농도는 4.40 mg $L^{-1}$, T-P의 농도는 0.27 mg $L^{-1}$를 나타냈다. 칠보천 유역은 타 지역에 비하여 오염도가 가장 낮았으며, BOD의 평균 농도는 1.19 mg $L^{-1}$로 I급수 수질을 나타냈고, T-N의 농도는 3.15 mg $L^{-1}$, T-P의 농도는 0.13 mg $L^{-1}$이었다. 원평천과 신평천은 BOD의 평균 농도가 $2.59{\sim}3.56mg\;L^{-1}$를 나타냈으며, T-N의 농도는 $4.06{\sim}7.35mg\;L^{-1}$로 타 지역에 비해 다소 높았다. 동진강 각 유역별 비점오염의 T-N 배출부하량은 원평천, 고부천, 용호 덕천천, 정읍천, 신평천 유역 순으로 많았다. T-P 배출부하량은 고부천 유역이 53 kg $day^{-1}$, 용호 덕천천 유역이 58 kg $day^{-1}$, 정읍천 유역이 45 kg $day^{-1}$, 원평천 유역이 68 kg $day^{-1}$, 칠보천 유역이 30 kg $day^{-1}$, 신평천 유역이 30kg $day^{-1}$이었다. 배출부하량의 오염원별 비율은 축산에 의한 영향이 가장 컸다. 용호천 유역은 강우기와 비강우기 T-N 유달부하량 차이가 매우 컸으며, 칠보천 유역은 비강우기와 강우기에 T-N 유달부하랑이 크지 않았다. 유역별 BOD, T-N, T-P의 유달율은 동진강 모든 유역에서 100% 이하였으나 강우시 T-N 유달율은 용호천 유역이 119.4%, 칠보천 유역이 117.5%로 높았다.

해상 프리캐스트 콘크리트 부유체 모듈 가접합을 위한 마이크로 실리카 혼입 수중용 에폭시 접합 성능 검토 : Part 2 - 구조 접합 성능 평가 (Micro-silica Mixed Aqua-epoxy for Concrete Module Connection in Water : Part 2 - Structural Application and Evaluation)

  • 최진원;유영준;정연주;권성준;김장호
    • 콘크리트학회논문집
    • /
    • 제27권1호
    • /
    • pp.29-35
    • /
    • 2015
  • 최근 연구되고 있는 해상 초대형 부유 콘크리트 구조물의 제작은 현장 타설이 어렵다는 단점이 있으므로 프리캐스트 콘크리트로 제작한 모듈을 수상에서 인양 후 프리스트레스력으로 접합 및 제작하는 것을 목표로 한다. 그러나 해상 환경에서 발생하는 다양한 하중 및 예상되는 상부 구조물에 의한 하중을 고려하였을 때, 프리스트레스력으로 접합되는 콘크리트 모듈 간의 접합부의 안정적인 거동 및 성능이 요구된다. 이에 프리스트레스력이 적용되기 전 가접합에 수중용 에폭시를 이용한 접합 방법이 고려되고 있는데, 수중용 에폭시는 고점성의 재료로서 내부에 공극이 발생하기 쉽다. 이를 해결하기 위하여 마이크로 실리카를 혼입하여 공극을 감소시킨 수중용 에폭시를 이용하여 콘크리트 부유체의 접하 거동에 대한 평가가 요구된다. 그러므로 이번 연구에서는 마이크로 실리카를 혼입한 수중용 에폭시를 이용하여 가접합하고 프리스트레싱을 적용한 시험체를 제작하여 성능을 평가하였다. 마이크로 실리카를 혼입한 수중용 에폭시로 접합된 콘크리트 모듈은 프리스트레싱만을 적용한 시험체에 비하여 균열 발생 및 응력 집중 현상이 완화되었으며, 최대 하중 및 변위는 일체형 RC 시험체에 비하여 10% 미만의 감소율을 나타내어 모듈형 콘크리트 부유체의 수상 접합을 위한 안정적인 접합재료로 사용 가능할 것으로 보인다.

역산이론을 이용한 연안 수질모형의 매개변수 추정 (Parameter Estimation of Coastal Water Quality Model Using the Inverse Theory)

  • 조홍연;조범준;정신택
    • 한국해안해양공학회지
    • /
    • 제17권3호
    • /
    • pp.149-157
    • /
    • 2005
  • 모형의 지배방정식에서 정의되는 대표적인 매개변수는 유역 및 대기로부터의 오염부하량,퇴적물로부터의 오염물질 용출부하량, 확산계수, 반응계수 등으로, 직접적인 관측이 곤란할 뿐만 아니라 많은 관측비용을 필요로 한다. 본 연구에서는 매개변수를 포함한 오염물질 수지방정식을 구성하고, 구성된 선형 연립방정식을 이용하여 계산된 농도분포자료와 관측된 시계열 농도턱포자료를 이용하여 계산한 질량변화량의 차이를 최소화하는 역산문제를 구성하여 모형의 매개변수를 추정하는 방법을 제시하였다. 이 방법을 이용하여 천수만, 울산만(울산항)해 역에서 관측된 연직방향 농도분포 자료를 이용하여 연직 확산계수 및 대기로부터의 오염부하량, 퇴적물로부터의 오염물질 용출부하량, 확산$\cdot$반응에 의한 오염물질 변화량 등을 추정하였으며, 추정 매개변수는 시기적으로 변동이 크게 나타났다. 한편, 관측자료와 추정매개변수를 이용한 계산결과를 비교한 결과, RMS 오차는 괄측자료 범위의 $5.0\%$ 이하, 일치지수는 0.95 이상으로 본 방법을 이용한 매개변수 추정결과의 신뢰성은 우수한 것으로 파악되었다.

농업용 저수지 상류유역의 비점원오염 유출부하량 산정 - 고성저수지를 대상으로 - (Dischatge Loads of Nonpoint Source Pollutant in the Upper Watershed of Inigation Reservoir - Case Study of the Goseong Reservoir -)

  • 김진호;한국헌;류종수;정구복;권순국
    • 한국물환경학회지
    • /
    • 제23권3호
    • /
    • pp.324-331
    • /
    • 2007
  • This study was conducted to evaluate the influence of pollutant loads on the water quality in the Goseong reservoir from May 2005 to October 2006. Annual total runoff at the Goseong-cheon watershed was 968.0 mm in 2005, 382.6 mm in 2006, respectively. The mean concentration of BOD, COD and SS in the stream were 2.28, 6.03, 46.97 mg/L in rainy seasons and 0.95, 2.14, 6.05 mg/L in dry seasons at SWT C sub-watershed. Total-N concentrations ranged from 2.60 to 3.18 mg/L at SWT C sub-watershed, which was generally higher than the quality standard of agricultural water (1.0 mg/L). Total-P concentrations ranged from 0.044 to 0.130 mg/L at SWT C sub-watershed. Measured pollutant loads in the SWT C sub-watershed were 36.7 kg/day of BOD, 72.3 kg/day of T-N and 2.3 kg/day of T-P in 2005 at SWT C sub-watershed, 63.9 kg/day of BOD, 82.8 kg/day of T-N and 1.1 kg/day of T-P in 2006 at SWT C sub-watershed, respectively. In the analysis of the effluent characteristics for NPS pollutants, it appeared that the loading rates of effluent from SWT C watershed were, respectively, BOD 62.3%, T-N 69.6%, T-P 71.1%, SS 70.1% during the rainy season in 2006. The calculated T-N daily pollutant loadings by the unit loading factor method from each sub-watershed were much greater than observed, but the calculated T-P daily pollutant loadings much lesser than observed.

강우시 비점오염원의 오염부하 특성 - 벚나무 재배지를 대상으로 - (Loading Characteristics of Non-Point Source Pollutants by Rainfall - Case Study with Cherry Tree Plot -)

  • 강미아;최병우;유재정
    • 지질공학
    • /
    • 제20권4호
    • /
    • pp.401-407
    • /
    • 2010
  • 농업지역에서 발생한 오염부하량을 결정하기 위해 여러 토지이용형태 중에서 벚나무 재배지(단위 비점오염원)에서 발생하는 오염부하 특성을 조사하였다. 유출시 발생된 강우사상에서는 강우량과 유출수량의 상관계수가 0.5로 낮게 나타나 투수성을 예측할 수 없는 수준이었다. 강우량 20mm 미만인 경우에도 강우강도가 8.8 mm/hr 수준으로 높은 경우에는 유출이 발생하였으나 강우량이 47.4 mm로 많은 경우라 할지라도 긴 무강우일수와 약한 강우강도를 보인 경우에는 유출이 발생하지 않았다. 강우사상시 발생된 유출량과 SS, BOD, COD, TN 및 TP 오염부하량과의 상관계수는 SS에서 최저값 0.71을 보인 것 이외에는 모두 r ${\geq}$ 0.92로 매우 유의한 값을 나타냈다. 한편 SS와 다른 오염물질간의 오염부하상관성도 모두 r ${\geq}$ 0.73의로 유의한 값을 나타내었으므로 SS관리를 통해 유기물질과 영양염에 대한 제어도 가능함을 알 수 있다. 최고 TN농도는 시비활동에 의해 직접적 영향을 받은 Event의 유출수에서 발생하였다. 따라서 농경지에서 발생하는 유출수의 오염수준을 평가할 때에는 시비여부를 반드시 고려해야 할 것이다.

습성강하물 중의 오염물질의 농도와 부하 - 충북 청주시를 중심으로- (The Concentrations and Loads of Pollutant in Wet Deposition in Cheongju)

  • 김진수;오승영;오광영;이종진;김선종;조재원;간종범;정구영
    • 한국수자원학회논문집
    • /
    • 제37권11호
    • /
    • pp.959-967
    • /
    • 2004
  • 충북 청주시에 위치한 충북대학교에서 강수에 따른 습성강하물 중의 TN, TP 및 COD의 농도와 오염부하를 조사하였다 강수사상에 대한 샘플은 1998년에서 2003년까지 채집되었다. 오염물질의 강수량가중평균 농도는 TN이 0.60mg/L, TP가 0.014mg/L, COD는 4.8mg/L이었는데, 이는 각각의 산술평균보다 26, 18, 14% 작게 나타났다. TN, TP 및 COD의 농도는 강수량이 증가함에 따라 감소하는 경향을 나타냈다. 모든 수질항목은 됨에 가장 많이 나타났는데, 이는 풍식 및 황사에 의한 먼지, 꽃가루 등 때문으로 생각된다. 습성강하물의 평균 연간부하는 TN 7.9kg/ha$\cdot$yr, TP 0.19kg/ha$\cdot$yr, COD 53.9ka/ha$\cdot$yr로 나타났는데, 이를 일본에서 보고된 각각의 연간부하와 비교하면 TN과 TP는 비슷했으나, COD는 약간 놀게 나타났다.

선형탄성해석과 mα-tangent방법을 이용한 배관 한계하중 평가 적용성 (Applicability of the mα-tangent Method to Estimate Plastic Limit Loads of Elbows and Branch Junctions)

  • 김재민;김상현;배경동;김윤재;김종성
    • 대한기계학회논문집A
    • /
    • 제41권6호
    • /
    • pp.499-505
    • /
    • 2017
  • 본 연구에서는 선형탄성 유한요소해석 방법과 $m_{\alpha}-tangent$ 방법으로 한계하중을 계산하고 이를 기존의 연구들에 의해 제시된 한계하중 식들과 비교하였다. 해석의 대상은 배관계의 대표 형상인 곡관과분기관을 선정하였다. 곡관과 분기관의 형상 변수를 다양하게 바꿔가면서 $m_{\alpha}-tangent$ 방법의 적용가능성을 살펴보았다. 하중은 내압하중과 면내굽힘하중을 각각 고려하였으며 곡관의 경우에는 기존의 한계하중식과 $m_{\alpha}-tangent$방법이 비교적 잘 일치함을 확인하였다. 하지만 분기관의 경우 형상의 특수성으로 인해 뚜렷한 경향 없이 기존의 한계하중 식과 $m_{\alpha}-tangent$ 방법이 일치하지 않는 것을 확인할 수 있었다. 이는 $m_{\alpha}-tangent$ 방법이 불연속부의 응력집중현상에 의해 왜곡된 결과를 갖기 때문으로 보인다.

빗물저장 및 활용을 위한 보도블럭구조의 최적화 (An Optimization of a Walkway Block Structure for Rainwater Harvesting)

  • 조태준;손병직
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권1호
    • /
    • pp.40-47
    • /
    • 2018
  • 다공성 보도 블록은 이미 많이 사용되지만, 큰 침투성으로 인해 블록의 강도를 감소시키고, 균열 및 침전의 문제를 만든다. 본 연구에서는 최소 주응력의 결정된 위치를 설계하고 검증하기 위하여, 이동하는 체중하중에 대한 보행로 블록에서의 최소 주응력의 위치를 결정함으로써, 주어진 문제에 대한 최적해를 제시하였다. 최소 주응력의 결정된 위치에 대한 검증 예를, 내부에 빗물을 저장하기위한 통행보도의 탄성 기초상의 2 차원 블록 부재에 대하여 제시하였다. 전단력의 합력에 대한 최소값은 ${\times}1$이 58.58 mm(전체 스팬의 30%, 200 mm)일 때, 최소 변형은 ${\times}2=80mm$(전체 스팬의 70%, 200 mm)에 있다. 수정 된 모델에서, 이동하는 경계 조건(보도 보행 하중)이 ${\times}1$(= 0 mm)에 있을 때, 168 mm (스팬의 84%, 200 mm)에서 최소 주응력의 위치가 발견되었으며, 스프링으로 모델링 된 기초의 응답에 대하여 모델링하였다. 결과적으로, 중립 축(${\times}2=167mm$)에서의 빗물저장을 위한 보도블럭의 "0"변형 위치가 3 차원 FEM 분석 검증을 통하여 결정되었다.

HIV, HCV와 HBV 유전자 분석시약의 성능 및 품질관리용 Plasma Working Standards 제조에 관한 연구 (Establishment of Plasma Working Standards for the Performance and Quality Assurance of NAT Screening Tests for HIV, HCV and HBV)

  • 김명한;조연정;권소영;조남선
    • 대한수혈학회지
    • /
    • 제23권2호
    • /
    • pp.152-161
    • /
    • 2012
  • 배경: 2012년 1월부터 국내에 신규로 도입되는 고위험군 바이러스 검사시약은 국내 검체를 이용한 성능 시험분석을 실시하여 식품의약품안전청 허가를 득하도록 일부 규정이 개정되었다. 이러한 바이러스 진단시약의 성능시험과 품질관리 규정을 이행하기 위해서는 국내 검체에서 유래된 국가표준물질이 필요하다. 이에 본 연구에서는 바이러스 핵산증폭검사시약의 성능평가와 품질관리를 위하여 다양한 농도로 구성된 HBV, HCV와 HIV의 핵산증폭검사용 혈장유래 표준물질(plasma working standards)을 제조하고자 하였다. 방법: 수혈 부적격의 HCV RNA 양성혈장 43단위, HCV RNA 양성혈장 25단위, 그리고 HIV RNA 양성혈장 26단위에 대해 핵산 정량검사와 유전자형 검사를 실시하였다. 이를 바탕으로 국내에서 유행하는 바이러스의 유전자형을 가진 고농도의 원료혈장을 선정하였다. 또 표준물질의 다양한 농도는 국내외 검사시약의 검출범위에 근거하여 적정한 농도범위를 선택한 후, 다양한 농도로 원료물질을 희석하고, 분병 처리 한 후 정량적으로 분석하였다. 결과: HBV, HCV와 HIV의 체외진단분석기용 핵산증폭검사의 성능평가용 plasma working standards는 총 13종의 다양한 농도물질로 제조되었다. 결론: 국내에서 혈액관련 고위험군 HBV, HCV와 HIV의 체외진단용 핵산증폭검사 시약의 성능 평가에 필요한 바이러스 핵산 검사용 국가표준물질을 처음 제조하여 그 기술을 수립하였다.