• Title/Summary/Keyword: Concentration Load

Search Result 1,036, Processing Time 0.033 seconds

Distribution Characteristics of Total Nitrogen Components in Streams by Watershed Characteristics (유역특성에 따른 하천에서의 존재형태별 질소 분포 특성 비교)

  • Park, Jihyoung;Sohn, Sumin;Kim, Yongseok
    • Journal of Korean Society on Water Environment
    • /
    • v.30 no.5
    • /
    • pp.503-511
    • /
    • 2014
  • The temporal and spatial analyses of total nitrogen (TN) fractionation were conducted in order to understand 1) total nitrogen components in streams and 2) their patterns in rainy and dry seasons. The result showed that the concentration of nitrogen components in stream water was lower in non-urban area and getting higher in urban area. Dissolved total nitrogen (DTN) was 95~97.7% of total nitrogen in streams, and the proportion of dissolved organic nitrogen (DON) and ammonia nitrogen ($NH_3-N$) was higher with increasing urban area. The concentration of total nitrogen and nitrate nitrogen ($NO_3-N$) were highest in winter among four seasons. The result was showed that concentration of $NH_3-N$ was same variation as concentrations of TN and $NO_3-N$ in urban-rural complex and urban areas, except rural areas. During rainy season, concentrations of particulate organic nitrogen (PON) and $NH_3-N$ increased in rural areas and decreased in both urban-rural complex and urban areas. Correlation between total nitrogen components and land uses was positively correlated with site > paddy, and negatively correlated with forest. The variation of total nitrogen concentration was determined by $NO_3-N$ in non-urban areas, by $NO_3-N$ and $NH_3-N$ in urban-rural complex and by $NH_3-N$ in the urban areas.

A Study on the Regulatory Effect of the Special Water Preservation Area of Lake Paldang Watershed Based on Long-Term Variation of Pollutant Source and Water Quality (수질과 오염원의 장기적 변화를 통한 팔당호 상수원수질보전 특별대책지역 규제효과 분석)

  • Kim, Ho-Sub;Park, Yun-Hee;Kim, Yong-Sam;Kim, Sang-Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.1
    • /
    • pp.43-54
    • /
    • 2019
  • The objective of this study was to assess the effect of policies on water quality management based on the changes in pollutants and water quality in Special Water Preservation Area (SWPA) of Lake Paldang watershed from 1990 to 2016. The population, total sewage and flow rate of wastewater in SWPA continuously increased from 1990 to 2016, while the location of new facilities for industrial and livestock facilities has been restricted. However, unlike the buffer zone in which industrial and livestock facilities were continuously reduced after implementing of TMDL, it was found that the effect of land-use regulations on industrial and livestock facilities in SWPA were mitigated by the increase in the size of large facilities. Since 1999 when the emission standard of public sewage treatment plants (STP) was changed, the water quality of Lake Paldang has increased despite the increase of pollutant source. Since emission standard of STP changed in 2012 (BOD 5 mg/L, TP 0.2 mg/L), BOD concentration in Lake Paldang has also improved to the level of water quality in the early 1990s where as TP concentration has remained at its lowest since 1990. BOD and TP average discharge concentration of 43 STP (${\geq}500m^3/day$) in 2016 have been maintained $1.7{\pm}0.7mg/L$ and $0.06{\pm}0.02mg/L$ respectively. While the discharged load of STP in SWPA was decreased by the concentration management, the contribution rate to the total discharged load of non-point pollutants increased to 70 % in 2015, and the contribution rate to the point discharged load of individual treatment facilities increased to 80 %.

A Load-balancing Routing Protocol in Ad Hoc Networks (애드 흑 네트워크에서 부하 균등을 고려한 라우팅 프로토콜)

  • 안상현;임유진;김경춘
    • Journal of KIISE:Information Networking
    • /
    • v.30 no.2
    • /
    • pp.252-259
    • /
    • 2003
  • In the case of link congestion, most of the existing ad-hoc routing protocols like AODV and DSR do not try to discover a new route if there is no change in the network topology. Hence, with low mobility, traffic may get concentrated on some specific nodes. Since mobile devices have low battery power and low computing capability, traffic concentration on a specific node is not a desirable phenomenon. Therefore, in this paper, we propose a new protocol called SLAP (Simple Load-balancing Ad-hoc routing Protocol) which resolves the traffic concentration problem by letting each node check its own load situation and give up its role as a packet forwarder gracefully in the case of high traffic load. We compare the performance of SLAP with that of AODV and DSR in terms of the forwarding traffic distribution.

Load-transfer mechanism in the ground with discontinuity planes during tunnel excavation (불연속면이 존재하는 지반에서 터널굴착에 의한 하중전이)

  • Lee, Sang-Duk;Byun, Gwang-Wook;Yoo, Kun-Sun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.1
    • /
    • pp.71-78
    • /
    • 2002
  • In this study, the influence of the presence of discontinuity planes on the load transfer mechanism and the pattern of loosening zone was studied based on the laboratory test. The trap-door and the reaction plates are installed as the bottom plane of the model box. The vertical discontinuity plane is installed in the dry sand. Various overburden heights and locations of discontinuity planes are applied as major factors in this study. The results show that at higher overburden heights over about 1.5 times the excavation width, the ratio of the transferred stress to the insitu stress converges to a certain value even if the overburden height increases further. The results also show that the discontinuity plane gives relatively larger influence on the load transfer mechanism, that produces the unsymmetrical load concentration, when the discontinuity plane locates within the tunnel width. When the discontinuity plane locates outside the tunnel width, the unsymmetrical load concentration is reduced considerably.

  • PDF

Development of Target-Controlled Infusion system in Plasma Concentration. PART2: Design and Evaluation (혈중 목표 농도 자동 조절기(TCI) 개발 PART2: 시스템 구현 및 평가)

  • 안재목
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.45-53
    • /
    • 2003
  • Based on the 4-compartmental pharmacokinetic model developed in PART1, target-controlled infusion(TCI) pump system was designed and evaluated. The TCI system consists of digital board including microcontroller and digital signal process(DSP), analog board, motor-driven actuator, user friendly interface, power management and controller. It provides two modes according to the drugs: plasma target concentration and effect target concentration. Anaesthetist controls the depth of anaesthesia for patients by adjusting the required concentration to maintain both plasma and effect site in drug concentration. The data estimated in DSP include infusion rate, initial load dose, and rotation number of motor encoder. During TCI operation, plasma concentration. effect site concentration, awaken concentration, context-sensitive decrement time and system error information are displayed in real time. Li-ion battery guarantees above 2 hours without power line failure. For high reliability of the system, two microprocessors were used to perform independent functions for both pharmacokinetic algorithm and motor control strategy.

Assessing unit load in farmland by application of liquid manure and organic farming (액비 및 유기농법 적용에 따른 농경지에서의 오염부하 원단위 평가)

  • So, Hyunchul;Jang, Taeil;Hong, Seung-Gil
    • Journal of Korean Society of Rural Planning
    • /
    • v.23 no.4
    • /
    • pp.39-48
    • /
    • 2017
  • National Institute of Environmental Research (NIER) has proposed new methodology for estimating unit load in order to overcome the limitations of past unit load based on short-term and local area based data. In the case of agricultural land, however, the results presented by NIER are still limited because of various agricultural activities and farmland characteristics. In this study, liquid manure treated paddy field and organic farming upland were selected for considering agricultural diversity. Four different methods for evaluating unit load were used for comparing previous research results. The results of different methods presented various trends compared with those of existing studies. Paddy field treated liquid manure was 1.3 times higher for T-N load and 3.1 times for T-P load than conventional paddy field. Conventional upland was 4.4 times higher for T-N load and 1.8 times higher for T-P load than organic farming upland. In the case of non-conventional farmland, this study showed different values with the unit loads presented by NIER. This implies that it is necessary to review and apply the unit loads considering various agricultural conditions when establishing environmental policy and rural planning.

Characteristics of Pollutant Loadings in a Rural Watersheds (농촌유역에서의 오염부하특성)

  • Cho, Jae-Won;Kim, Jin-Soo;Oh, Kwang-Young
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.449-452
    • /
    • 2002
  • Characteristics of pollutant load during irrigation and non-irrigation periods was investigated for streamwater from a rural watershed. Water was sampled and discharge was measured at 5-days intervals at outlet of study area. The mean concentrations of TN and TP in an irrigation period are higher than in an non-irrigation period, while mean COD concentration in an irrigation period is lower than in a non-irrigation period. For increasing discharge during an irrigation period, TN concentration increase, TP concentration is nearly unchanged, and COD concentrations decreases.

  • PDF

PHOTOELASTIC ANALYSIS OF STRESS INDUCED BY DIFFERENT TYPE ENDOSSEOUS IMPLANTS (골내 임플랜트의 종류에 따른 광탄성 응력 분석)

  • Chung Chae-Heon;Chang Doo-Ik
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.4
    • /
    • pp.661-678
    • /
    • 1993
  • The purpose of this study was to analyze the stress distribution at supporting bone according to the types of endosseous implants. This investigation evaluated the stress patterns in rectangular photoelastic models produced by four different types of dental implants such as $Br\ddot{a}nemark$, screw type of Steri-Oss, blade type of Steri-Oss, IMZ with IMC and resin tooth using the techniques of quasi-three dimensional photoelasticity. All prostheses were casted in the same nonprecious alloy and were cemented or screwed on their respective implants and abutments. 20 kg of vertical load was applied on the central fossa of casted crown and 16 kg of inclined had was applied on the top third of distal surface of casted crown respectively. The results were as follows : 1. Under the vertical load, screw implants of Steri-Oss and $Br\ddot{a}nemark$ showed increasing stress condition between and around the screw threads along the implant lateral surface and cylindrical implant of IMZ showed the less stress condition along the lateral surface with concentration of stress mostly near the root apex. 2. Under the vertical load, the stress of Steri-Oss blade was distributed uniformly at the alveolar bone under the broad blade. 3. Under the inclined load, the stress concentration of Steri-Oss screw and $Br\ddot{a}nemark$ was developed highly around the mesiocervical bone area on the contralateral side to force application. The stress of $Br\ddot{a}nemark$ with flexible gold glod was more concentrated in the cervical bone area than that of Steri-Oss with stiff screw. 4. Under the inclined load, the stress of Steri-Oss blade broadly was distributed around the mesioceivical bone area and the lower and mesial bone area of the blade. 5. Under the Inclined load, IMZ implant showed the gap between c개wn and fixture due ta deformation of the IMC and IMZ was lower in stress concentration developed around the mesiocervical bone area than $Br\ddot{a}nemark$ and Steri-Oss screw. 6. Under the inclined load, the stress magnitude induced in the mesiocervical bone area of implants was in order of $Br\ddot{a}nemark$, Steri-Oss strew, IMZ and Stsri-Oss blade. 7. Tilting forces as compared to axial forces exerted greater magnitude of stress in the cervical bone area of the implant. 8. In respect of stress distribution, Steri-Oss blade was superior than any other implants and in respect of the stability by horizontal lone, IMB and $Br\ddot{a}nemark$ was inferior than any other implants.

  • PDF

Modeling Cutter Swept Angle at Cornering Cut

  • Chan, K.W.;Choy, H.S.
    • International Journal of CAD/CAM
    • /
    • v.3 no.1_2
    • /
    • pp.1-12
    • /
    • 2003
  • When milling concave corners, cutter load increases momentarily and fluctuates severely due to concentration and uneven distribution of material stock. This abrupt change of cutter load produces undesirable machining results such as wavy machined surface and cutter breakage. An important factor for studying cutter load in 2.5D pocket milling is the instantaneous Radial Depth of Cut (RDC). However, previous work on RDC under different corner-cutting conditions is lacking. In this different corner shapes. In our work, we express RDC mathematically in terms of the instantaneous cutter engage angle which is defined as Cutter Swept Angle (CSA). An analytical approach for modeling CSA is explained. Finally, examples are shown to demonstrate that the proposed CSA modeling method can give an accurate prediction of cutter load pattern at cornering cut.

The Evaluation of the Loads Acting on the Pillar in Two-Arch Tunnel (2-Arch 터널의 중앙벽체에 작용하는 하중산정)

  • Do, Jong-Nam;Oh, Gyoo-Chul;Chun, Byung-Sik
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1774-1781
    • /
    • 2007
  • In this study, Matsuda's formula, which has been used to evaluate the acting load on the concrete pillar in 2-Arch tunnels, is investigated and a load reduction factor $({\alpha})$, which has been estimated from numerical parametric studies, is proposed for a better design of 2-Arch tunnels in the future. Numerical parametric studies show that the concrete pillar is subjected to a stress concentration on the excavation side during the first tunnel driving and when tunnel excavation is completed, the induced stress on the pillar in a poor quality of ground condition is 1.5 to 1.8 times the stress developed during the first tunnel driving. In addition, the numerical studies indicate that the acting load on the pillar is in the range of $14{\sim}83%$ of the load estimated by Matsuda's formula. From these results, a load reduction factor $({\alpha})$ is determined and it would make 2-Arch tunnel design more economically.

  • PDF