• Title/Summary/Keyword: Concentration Factor

Search Result 3,812, Processing Time 0.035 seconds

Detemination of Short-term Bioconcentration Factor on Dichlorvos, Methidathion and Phosalone in Brachydanio rerio and Xiphophorus hellieri (Brachydanio rerio와 Xiphophorus hellieri를 이용한 Dichlorvos, Methidathion 및 Phosalone의 단기간 생물농축계수의 측정)

  • 민경진;전봉식;차춘근;김근배;조영주
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.3
    • /
    • pp.99-106
    • /
    • 1998
  • This study was performed to investigate the bioconcentration of dichlorvos, methidathion and phosalone in zebrafish (brachydanio rerio), red sword tail(Xiphophorus hellieri). The fishes were exposed to 0.05 ppm, 0.01 ppm, 0.50 ppm, one-hundredth concentration of 96-hrs LC$_{50}$ and one-thousandth concentration of 96-hrs LC$_{50}$ and test periods were 3, 5 and 8 days. The deputation rate of each pesticide from the whole body of fish was determined over the 24-hr period after treatment. Obtained results are summerized as follows: In the case of dichlorvos, dichlorvos concentration in zebrafish extract and BCF$_{s}$ of dichlorvos were increased as increasing test concentration. In the case of same experimental concentrations, dichlorvos concentration in zebrafish extract and BCF$_{s}$ of dichlorvos were decreased as proloning test periods, especially dropped after 5days. Dichlorvos concentration in red sword tail extract were increased as increasing test concentration, lyat BCF$_{s}$ in concentration of 0.05 ppm, 0.01 ppm and one-hundredth of 96-hrs LC$_{50}$ were decreased. Methidathion and phosalone concentration in zebrafish extract in zebrafish extract were increased as increasing test concentration, but there was little difference in BCF$_{s}$. In the case of same experimental concentrations, there were little differences in BCF$_{s}$ and concentration in zebrafish extract. In the case of red sword tail, it was impossible to calculate on BCF$_{s}$ data because test concentration was under the detecting limit on GC or test fish were die. Determined deputation rate conatant were highest on dichlorvos, and followed by methidathion, and phosalone. The results of determining depuration rate of these pesticides showed that the high BCF in fish might be due to the slow depuration rate in fish, it is thought to be responsible for vapor pressure, water solubility and partition coefficient. It is suggested that one-hundredth concentration of 96-hrs LC$_{50}$ will be proper test concentration because one-thousundth of LC$_{50}$ was under the detecting limit on GC. Dichlorvos, methidathion and phosalone, organophosphorous pesticides, were examined to their BCF$_{s}$ and depuration rates by means of fish test.

  • PDF

Fatigue Life Evaluation of Notched Shaft Using Local Strain Approach (국부변형률방법을 이용한 노치를 지닌 축의 피로수명평가)

  • 고승기;김영일;이학주;김완두;이상록
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.4 no.2
    • /
    • pp.80-89
    • /
    • 1996
  • Fatigue life of a notched shaft was evaluated in order to estimate the durability and integrity of the notched shaft in design stage. Cumulative fatigue dama- ge analysis was performed using local strain approach based on the assumption that the fatigue life of a notched component is approximately same as that of a smooth specimen is subjected to the same strain at the notched component. In this paper, shafts with different notch root radius of 1, 2㎜ resulting in different values of stress concentration factors were tested under||rotating bending fatigue loading condition. Theoretical stress concentration factor for each notch type was calculated using finite element method. Fatigue life prediction program, FALIPS, written in C language was developed using the strain-life curve, and the local strain approach integrating Neuber's rule, cyclic stress-strain, and hysteresis loop equations. The fatigue life evaluated using the fatigue notch factor obtained from the experimentally determined fatigue strength showed very large scattering with nonconservatism, but the fatigue notch factors derived from the stress concentration factors and Peterson's equation reduced the considerablely accurate fatigue life evaluation within a factor of three.

  • PDF

Oxygen Supersaturation in Korean Streams as a Stress Factor to Fish (어류 스트레스 요인으로서 우리나라 하천의 산소과포화 실태)

  • Lee, Saeromi;Lee, JaeYong;Choi, Jaeseok;Kim, Sunjung;Ahn, Buyoung;Kim, Bomchul
    • Journal of Korean Society on Water Environment
    • /
    • v.28 no.2
    • /
    • pp.213-218
    • /
    • 2012
  • Abnormal dissolved oxygen concentration in aquatic habitat, both depletion and supersaturation, can be stress factor to aquatic animals. In this study the nationwide distribution of oxygen supersaturation was analyzed for three categories of streams (43 urban streams, 15 rural streams, and 14 forest streams) by using monitoring network data of the Korean Ministry of Environment. From the distribution analysis 30% of urban streams showed hyperoxic condition of eutrophic level, while no forest stream showed hyperoxic condition. The physiological effect of hyperoxia on fish was examined using two species of fish Zacco koreanus, which resulted in higher concentration of a stress hormone (cortisol) in fish exposed to hyperoxic concentration (196%) of oxygen. This study shows that hyperoxic condition is ubiquitous in urban and rural Korean streams, and it can be a stress factor to aquatic animals.

Pharmacokinetics of CJ-50001i Recombinant Human Granulocyte-Colony Stimulating Factor, in Rats and Dogs (CJ-50001 (recombinant human granulocyte-colony stimulating factor)의 흰쥐와 개에서의 약물동태학적 연구)

  • 김성남;신재규;이수정;정용환;하석훈;김기완;고형곤;김제학
    • Biomolecules & Therapeutics
    • /
    • v.6 no.4
    • /
    • pp.400-405
    • /
    • 1998
  • The pharmacokinetics of CJ-50001 (recombinant human granulocyte-colony stimulating factor, developed by R&D center of Cheil Jedang Corp.) were investigated in rats and dogs. The serum concentrations of CJ-50001 were measured by a sandwich enzyme immunoassay. After single intravenous (iv) administration of Cf-50001 to rats at a dose of 5 $\mu$g/kg, the mean terminal half-life and area under the concentration-time curve (AUC) were 0.96 h and 124.497g . h/ml, respectively. After single subcutaneous (sc) administration at the same dose, maximum serum concentration was observed at about 2 hours after administration, and the mean terminal half-life, AUC and the bioavailability were 1.11 h,63.58$\mu$g . h/ml and 51.07%, respectively. In repeated dosing studies, CJ-50001 was administered iv and sc to rats at a daily dose of 5$\mu$g/kg for 7 days. The pharmacokinetic parameters, such as mean AUC and terminal half-life, were no significantly different from those of single administration. Following single iv and sc administration of CJ-50001 to dogs at a dose of 5 $\mu$g/kg, mean AUCs were much higher than those of rats, due to the decreased clearence (CL). After sc administration to dogs, maximum serum concentration was observed at 2~4 hours after administration and the bioavailability was 54.60%.

  • PDF

The Study on Stress Distibution of a Slotted Plate (슬롯 을 갖는 平板 의 應力分布擧動 에 관한 硏究)

  • 송삼홍
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.6 no.4
    • /
    • pp.367-376
    • /
    • 1982
  • Stress concentration mainly occurs near holes and notches. Then local stress is larger than nominal stress. It is necessary that stress concentration phenomena are studied because it can act as a cause of fracture of material. In order to analyze fracture of material including holes, stress concentration factor and stress distribution must be studied more carefully. In this paper the stress concentration and distribution of a slotted plate is examined. Hardened 7:3 brass plate with 4 different slots including a circular hole is used. And ratios of slot length to its root radius are 1, 2, 3, 24, 4. The stress distribution is measured by using strain gages attached to the plate with variable width. And obtained experimental data are adjusted by using calibrated gage factor.

Trace Metals of Ambient TSP in Daegu Area (대구지역 총 부유분진중 중금속)

  • 이찬형
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.1
    • /
    • pp.67-73
    • /
    • 2003
  • This study was carried out to characterize the behavior and sources of particulate trace metal in Daegu city. TSP (Total Suspended Particulate matter) was collected by filters on High Volume Air Sampler from the four areal (reference, residential, commercial, industrial area). The moult were analyzed by AAS after preliminary treatment. The average centration trend of trace metals contained in TSP was shown as follows : Fe > Cu > Pb > Mn > Ni > Cr > Cd. The trace metals showed the highest concentration in the industrial area. This study showed the seasonal variation of trace metals. Fe and Mn showed high concentration in spring, whereas Cr, Ni, Cd and Pb showed high concentration in winter. Also this study showed the regional variation of trace metals. The order of the average concentration of trace metals was : industrial > commercial > residential > reference area. Using Mn as a reference element, the enrichment factor analysis were used for identifying the trace element contributors. The enrichment factors of Cr, Fe < 10 were considered to have a significant dust and soil source and termed nonenriched. Pb, Cd, Cu >>10 were enriched and had a significant fraction which was contributed by anthropogenic sources.

The Fatigue Behavior by Variety of Crack Length of Surface Cracked Plate with Stress Concentration Part (응력집중부를 갖는 표면균열재의 균열길이 변화에 따른 피로거동)

  • 남기우;김선진
    • Journal of Ocean Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.83-91
    • /
    • 1995
  • Surface defects in structural members are apt to be origins of fatigue cracks growth, which may cause serious failure of whole structures. Most structure has a part where stress concentrates such as welded joints, corner parts, etc. And then, analysis on crack growth and penetration from these defects, therefore, is one of the most important subjects for the reliability of LBB design. The present paper has performed an experimental and analysis on the fatigue crack propagation by variety in crack length of surface cracked plate with stress concentration part. The crack growth behavior can be explained quantitatively by using Newman-Raju equation and the stress partitioning method proposed by ASME B&P Code Sec. XI. The stress concentration factor $K_t$ has affected on the crack growth. The crack growth after penetration depends upon the initial front side crack length.

  • PDF

Urine Concentration and the Adaptation of Renal Medullary Cells to Hypertonicity (소변농축과 장력 스트레스에 대한 콩팥 수질 세포들의 적응)

  • Kim, Dong-Un
    • Childhood Kidney Diseases
    • /
    • v.11 no.2
    • /
    • pp.145-151
    • /
    • 2007
  • Hypertonicity (hypernatremia) of extracellular fluid causes water movement out of cells, while hypotonicity(hyponatremia) causes water movement into cells, resulting in cellular shrinkage or cellular swelling, respectively. In most part of the body, the osmolality of extracellular fluid is maintained within narrow range($285-295 mOsm/kgH_2O$) and some deviations from this range are not problematic in most tissue of the body except brain. On the other hand, the osmolality in the human renal medulla fluctuates between 50 and $1,200 mOsm/kgH_2O$ in the process of urine dilution and concentration. The adaptation of renal medullary cells to the wide fluctuations in extracellular tonicity is crucial for the cell survival. This review will summarize the mechanisms of urine concentration and the adaptation of renal medullary cells to the hyper tonicity, which is mediated by TonEBP transcription factor and its target gene products(UT-A1 urea transporter etc.).

  • PDF

The Development of N2O Emission Factor at Municipal Solid Waste Incinerator (도시고형폐기물 소각시설의 N2O 배출계수 개발)

  • Ko, Jae Churl;Choi, Sang Hyun
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.40-45
    • /
    • 2019
  • In this study, nitrous oxide ($N_2O$) emission concentration was measured 3 times continuously for 24 hours from August 27, 2018 to October 22, 2018 and non-dispersive infrared (NDIR) spectrometer was used to calculate $N_2O$ concentration of exhaust gas from municipal solid waste (MSW) incinerator. As a result of $N_2O$ emission characteristics, it is estimated that $N_2O$ emission concentration is due to the difference of furnace temperature, oxygen concentration rather than the chemical component of waste. The measured $N_2O$ emission concentration of MSW incinerator was obtained in the range of 53.6 ~ 59.5 ppm and the total average concentration was measured 55.6 ppm. Therefore, the amount of $N_2O$ emissions calculated from the $N_2O$ concentration was $98.05kg\;day^{-1}$ on average and the amount of $N_2O$ distribution in the range of $90.41{\sim}108.44kg\;day^{-1}$ was obtained. As a result, the $N_2O$ emission factor of the MSW incinerator was estimated to be $1,066.13g_{N_2O}\;ton_{waste^{-1}}$. The estimated $N_2O$ emission factor of the MSW incinerator was 20 times higher than calculated emission factor used in the Tier 2 method. Consequently, it is considered that the method of calculating the amount of $N_2O$ emission in the MSW incineration facilities using waste type and incineration amount needs to be supplemented to ensure accuracy.

Analysis of Ventilation Performance Using a Model Chamber

  • Kang Tae-Wook;Chang Tae-Hyeon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.7
    • /
    • pp.736-743
    • /
    • 2005
  • In this study, three different types of mechanical ventilation systems are compared based on their ventilation characteristics: tracer gas concentration decay characteristics, and ventilation effectiveness by calculating actual ventilation air flow rate. The experiments are performed by using a step-down method for measuring tracer gas. $CO_{2}$ gas, concentration in the model chamber. Application of a mixing factor, k, was used and measured values ranged from 0.68 to 0.77. The Type 2 ventilation system was found to have the highest ventilation effectiveness rather than the Types 1 and 3.