• 제목/요약/키워드: Concentration Characteristics

검색결과 9,726건 처리시간 0.037초

부산 지역의 SO$_2$ 농도 변화 특성에 관한 고찰 (On the Characteristics of the SO$_2$ Concentration Variation in Pusan, Korea)

  • 전병일;김유근;이화운
    • 한국대기환경학회지
    • /
    • 제10권4호
    • /
    • pp.245-251
    • /
    • 1994
  • We considered that characteristics of SO$_2$, concentration level and relations of the meteorological parameters and high pollution concentration from the data measured 7 air quality continuous monitoring stations during 4 years, from 1990 to 1993 in Pusan. The SO$_2$ concentration level showed decreasing trend yearly, it was maximum in Winter, minimum in Summer. The time of SO$_2$ peak concentration lagged from seashore to land because of break-down of the nocturnal inversion layer and seabreeze. Ihe correlations of daily SO$_2$, value between various air quality continuous monitoring stations were highest between Beomcheondong and Meongryundong, lowest between Daeyeondong and Sinpyeongdong because of difference of air Pollution emission sources characteristic. The meteorological parameters affecting SO$_2$ concentration level were minimum temperature, relative humidity, wind speed and air pressure. The SO$_2$ high pollution($\geq$95ppb) occurred almost in Winter, particulaly in such day showing lower wind speed and higher air pressure. Elementary SO$_2$ high Pollution Predictor were high pressure system and stability of lower atmosphere.

  • PDF

지하도상가의 리모델링 및 공간 특성에 따른 포름알데히드 농도 분석 (Estimation of the Formaldehyde Concentration of Subterranean Shopping Centers according to their Spatial Configuration and Renovation)

  • 심경섭;김현수;유슬기;김수민
    • 한국가구학회지
    • /
    • 제25권3호
    • /
    • pp.182-187
    • /
    • 2014
  • Underground shopping center has become a important commercial facility due to their good accessibility to the public transport. However, underground shopping center has high risk of air contaminants emission like formaldehyde and lowered indoor air quality. In this study, formaldehyde concentration of the underground shopping center was estimated according to the renovation and characteristics of space. It was found that newly renovated underground shopping center has low formaldehyde concentration. In case of closed entrance type, the formaldehyde concentration was 320 % higher than open type. Formaldehyde concentration was varied by product type and especially, high formaldehyde concentration was measured near the stores selling nail polish and cosmetics. It is important to apply appropriate ventilation system according to characteristics of space.

  • PDF

일부 종합 병원 로비의 공기 중 엔도톡신 농도에 미치는 환경 요인 평가 (An Assessment of Environmental Characteristics Associated with the Level of Endotoxin Concentration in Hospital Lobbies)

  • 이경민;염정관;이원재;류승훈;박동진;박동욱
    • 한국산업보건학회지
    • /
    • 제24권3호
    • /
    • pp.310-320
    • /
    • 2014
  • Backgrounds: Endotoxin, which found in the outer membrane of the gram-negative bacteria cell wall, makes up almost all of the lipopolysaccharide(LPS). When people are exposed to endotoxin,it can result in diverse health effects such as an airway irritation and inflammation, fever, malaise, bronchitis, allergic asthma, toxic pneumonitis, hypersensitivity lung disease. Cases among the elderly, children or pregnant can occur more frequently than a healthy adult if they are repeatedly exposed to the existing endotoxin. Therefore, we investigated and assessed the environmental characteristics associated with the airborne endotoxin concentration level in six hospital lobbies. Method: Endotoxin from indoor air in six hospital lobbies was measured by an area sampling method and analyzed according to American Society for Testing and Materials International(ASTM international) E2144-01. Total suspended particulate(TSP), carbon dioxide($CO_2$), temperature and humidity were also measured by using direct reading measurements or airborne sampling equipment at the same time. Environmental characteristics were appropriately divided into two or three groups for a statistics analysis. One-way analysis variable(one-way ANOVA) was used to examine a difference of the endotoxin concentration, depending on the environmental characteristics. In addition, only variables with p-value(p<0.25) were eventually designed to the best model by using multiple regression analysis. Results: The correlation analysis result indicated that TSP(p=0.003) and $CO_2$(p<0.0001) levels were significantly associated with endotoxin concentration levels. In contrast, temperature(p<0.068) and humidity(p<0.365) were not associated with endotoxin concentration. Levels of endotoxin concentration were statistically different among the environmental characteristics of Service time(p=0.01), Establishment of hospital(p<0.001), Scale of hospital(p=0.01), Day average people using hospital(p=0.03), Cleaning time of lobby(p=0.05), Season(p<0.001), and Cleaning of ventilation system(p<0.001) according to ANOVA. Finally, the best model(Adjusted R-square=72%) that we designed through a multiple regression test included environmental characteristics related to Service time, Area of lobby, Season, Cleaning of ventilation system, and Temperature. Conclusions: According to this study, our result showed a normal level of endotoxin concentration in the hospital lobbies and found environmental management methods to reduce the level of endotoxin concentration to a minimum. Consequently, this study recognized to be requirement for the management of ventilation systems and an indoor temperature in order to reduce the level of endotoxin concentration in the hospital lobbies.

단면 확대 덕트 내에 형성된 삼지화염의 부상특성에 관한 실험적 연구 (An Experimental Study on the Lift-off Characteristics of the Triple Flame within a Diverging Duct)

  • 서정일;김남일;오광철;신현동
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 제26회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.85-91
    • /
    • 2003
  • The lift-off characteristics of the triple flame within a diverging duct have been studied experimentally using a multi-slot burner, which can control the concentration gradient and the mean velocity independently. In this experiment the triple flame was stabilized successfully in lift-off condition and flame stabilization with a duct or without a duct, lift-off heights, and some other characteristics were examined for propane flame. It was examined that the effects with various concentration gradient and mean velocity on the triple flame. It was found that minimum value of the lift-off heights exist at a certain concentration gradient for constant mean velocity and flame with a duct is more stable than that without. Moreover the propagation velocity of the flame becomes maximum at a certain concentration gradient regardless of mean velocity.

  • PDF

단지개발 지구내에 불법매립된 폐기물의 오염특성 분석 (Contamination Characteristics of Open Dumped Wastes at Land Developing Site)

  • 정하익;김상근;이용수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.415-418
    • /
    • 2000
  • There has been a steady increase in geoenvironmental engineering projects where geotechnical engineering has been combined with environmental concerns. Many of these projects involve some investigation on contaminant around unplaned waste landfill. In this study, investigation and test on contamination characteristics of wastes dumped at municipal site were carried out. Testing wastes were sampled at this site. Sampled wastes were divided into waste itself and soil to analysis the characteristics of waste and soil. As a result of this study, the concentration of soil and waste were investigated. And measured concentration were compared with related concentration criteria.

  • PDF

비비등 수직 하향 유동의 대류 열전달 특성 (The Characteristics of Convective Heat Transfer in Non Boiling Vertical Downard Flow)

  • 이동상;김재근;양희준;오율권;차경옥
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.118-123
    • /
    • 2000
  • This experimental study was conducted to figure out the characteristics of convective heat transfer in non boiling vertical downward flow with polymer additives. This experiment was studied in 26mm diameter, 800mm heating length and $1{\times}10^5W/m^2$ heat flux. The polymer concentration ranged from 0PPM to 500PPM with corresponding from Reynolds number $3.3{\times}10^4$ to $6.8{\times}10^4$ in non boiling vertical downward flow. Experimental results show that the characteristics of convective heat transfer was a strong function of polymer concentration and it has decreased with increasing the polymer concentration in non boiling vertical downward flow.

  • PDF

Analyze the channel doping concentration characteristics of junctionless nanowire transistors by using Edison simulation

  • Choi, Jun Hee;Lee, Byung Chul;Kim, Jung Do
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제2회(2013년)
    • /
    • pp.266-268
    • /
    • 2013
  • In this paper, we study the channel doping concentration characteristics of junctionless nanowire transistors (JLT) using Edison nanowire FET device simulation. JLT has no junctions by very simple fabrication process. And this device has less variability and better electrical properties than classical inversion-mode transistors with PN junctions at the source and drain. In this simulation we use tri-gate structure. Source and drain doping concentration is $10^{20}atoms/cm^3$. The simulation results show that I-V characteristics of JLT change due to the variation of channel doping concentration.

  • PDF

Pink Noise가 개인별 특성에 따라 뇌파 집중지표에 미치는 영향과 다중지능과의 관계 (Relationship Between Effects of Pink Noise on Brain Wave Concentration Index by Individual Characteristics and Multiple Intelligence)

  • 신성권;심준영
    • 감성과학
    • /
    • 제16권4호
    • /
    • pp.481-492
    • /
    • 2013
  • 이 연구는 성인 남녀 462명을 대상으로 사전 설문검사를 통해 성별, 손잡이, 혈액형, 연령 등의 개인별 특성 집단과 다중지능 유형별 점수를 분류하였다. 그런 다음 뇌파측정시스템을 이용하여 전전두엽 부위인 Fp1과 Fp2 부위에 측정 전극을 부착하고 무자극 상태와 순수한 Pink noise 청각자극 상태에서의 집중력의 변화와 다중지능과의 관계를 알아보고자 하였다. 공분산분석 결과, 무자극에 비해 Pink noise 자극 시 대상자 전체의 평균 집중력이 유의하게 높게 나타났다. 개인별 특성에서는 남녀 성별을 제외한 왼손잡이, A형, 30대 집단에서 집중력이 유의하게 높게 나타났다. 그리고 무자극에 비해 Pink noise 상태의 집중력은 공간적 지능과의 관계가 더욱 강화되었고, 음악적 지능과는 음적 상관관계를 형성하였다. 이러한 결과는 집중력 향상을 위한 Pink noise 활용 시 개인별 특성을 반영해야할 필요성이 있음을 시사하였다.

Plasma concentration of dopamine varies depending on breed, sex, and the genotype of DRD4 in horses

  • Junyoung, Kim;Heejun, Jung;Jae-Young, Choi;Jang-Won, Lee;Minjung, Yoon
    • Journal of Animal Science and Technology
    • /
    • 제64권4호
    • /
    • pp.792-799
    • /
    • 2022
  • Dopamine (DA) is known to be a key modulator of animal behaviors. Thus, the plasma concentration of DA might be used as a biomarker for the behavioral characteristics of horses. The behavioral characteristics of horses vary depending on the breed, age, and sex. Moreover, the DA receptor genotypes are also related to horse behaviors. Thus, the aim of this study was to investigate the DA concentration variations of horse plasma by breed, age, sex, or genotype of its receptor. The horses were divided by breed into Thoroughbred (n = 13), Pony (n = 9), Warmblood (n = 4), and Haflinger (n = 5). The age variable was divided into three different groups: post-pubertal (2-5 years, n = 6), adult (6-13 years, n = 19), and aged horses (15-24 years, n = 6). The sex variable was divided into geldings (n = 8) and mares (n = 23). Approximately 10 mL of blood was collected, and an ELISA kit was used to measure the plasma concentration of DA. Polymerase chain reaction analysis was performed to identify the genetic variation in the DA D4 receptor gene (DRD4). SPSS statistical software was used for statistical analysis. The DA concentrations in geldings were significantly lower than those in mares. There was no significant difference in DA concentrations among breed and age groups. Horses with the GG and GA genotypes had significantly higher plasma concentrations of DA compared to horses with the AA genotype for the G292A gene. Briefly, the plasma concentration of DA varied depending on the sex and genotype of G292A. These factors should be considered when the concentration of DA is used as a biomarker for the behavioral characteristics of horses. In conclusion, the DA concentration or DRD4 genotype of horse plasma has the potential to be used as a biomarker that can predict the behavioral characteristics of horses.

중소도시지역 비점오염물질의 유출 특성 (Runoff Characteristics of Nonpoint Pollutants Source in Urban Area)

  • 이건직;성진욱;박주현;조규수;박제철
    • 한국환경과학회지
    • /
    • 제19권7호
    • /
    • pp.819-827
    • /
    • 2010
  • This study was conducted to investigate runoff characteristics of non-point pollutants source at the urban area in boeun area, Chungbuk Province. The monitoring site covering the watershed of $2.11\;km^2$ contains about 40.3 % of total watershed with the urban area. The monitoring was conducted with six events for five months and Event Mean Concentration(EMC) and Site Mean Concentration(SMC) of SS, BOD, CODMn, T-N, T-P were calculated on the result of the water quality parameters. As a result of the comparion between Arithmetic Mean Concentration and Event Mean Concentration, it showed that over all Event Mean Concentration was higher than Arithmetic Mean Concentration. And it showed that SS, BOD, T-P featured the first-flushing effect, showing relatively high concentration in early-stage storm event.