• 제목/요약/키워드: Concentration

검색결과 57,967건 처리시간 0.066초

산소부하 연소 시스템을 이용한 폐기물 열처리에 관한 연구 (The Study of Waste Treatment using Advanced Oxygen Enriched Combustion System)

  • 이건주
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 제26회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.231-239
    • /
    • 2003
  • In this study, the waste of landfill was treated using advanced enriched oxygen combustion system. The oxygen concentration of this study was 21%, 25%, 30% and 40% and the operating capacity was 200 g/min and the residence time was 10 minutes. As increased the oxygen concentration of combustion air. temperature of the incinerator was increased and the temperature was increased rapidly when the oxygen concentration was 30%. As increased the oxygen concentration, the NOx (ppm) of flue gas increase d for thermal NOx, however the CO (ppm) of flue gas decreased according to the increase of combustion efficiency . The optimum operation condition of incineration was obtained when the oxygen concentration is 30%${\sim}$40%. The unburned carbon of ash decreased from 10% to 4% when the oxygen concentration was increased from 21% to 30%, therefore the high combustion efficiency can be obtained if used the oxygen enriched combustion system.

  • PDF

Polyolester base oils과의 상호작용에 의한 Organic Phosphates계 내하중첨가제의 마모방지 성능 (The antiwear performance of several organic phosphates from the aspect of interaction between polyolester base oil and additive)

  • 한두희
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.189-194
    • /
    • 1999
  • The antiwear performance of several organic phosphates ,such as tricrecylphosphate(TCP), tributylphosphate(TBP), diphenylhydrogenphosphate(DPHP) ,dissolved in polyol ester based oils is studied. These organic phosphates are well known for antiwear additive for lubricating oil that produce reacted surface protective film. These antiwear additives can drastically reduce wear with their concentration increasing, because the amount of additive adsorbed on metal sur(ace increases. But in the higher concentration region, the wear is increased by excessive and corrosive reaction of the metal surface with these additives. That is to say, there is an optimum concentration for minimum wear. The optimum concentration was different with the kinds of base oils and additives. Different polyolesters showed different optimum concentrations of the additive. The order of optimum concentration among the polyolesters was different with different phosphates. The order of the optimum concentration is shown that the effect of the concentration of additives on the antiwear performance. It can be explained by the interaction between additives and base oils using the solubility parameter.

  • PDF

Application of eddy current technique for the non-contact sensing of low concentration of electrolytic solution

  • Ismail, Abu Bakar Md.;Shida, Katsunor
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1310-1313
    • /
    • 1997
  • Application of eddy current sensing principle for the non-contact estimation of very low concentration of electrolytic solution is presented in this paper. for this application, a new, simple, low-cost, low-power structure for the eddy current sensor is proposed. By measuring the eddy current produced in the conducting electrolytic solution, the concentration is estimated. Therefore, the unknown concentration can be estimated comparing with the database which is prepared as the relation between the change in inductance and various concentrations of electrolytic solution. The concentration, as low as l ppm of the solutioin can be detected by this sensor. It was tested on various low concentration solutions of NaCl. It shows distinct response for various concentrations.

  • PDF

부산광역시 NO2 농도 분포 특성에 관한 연구 (A study of Distribution Characteristic of NO2 Concentration at Busan Metropolitan City)

  • 장난심
    • 한국환경과학회지
    • /
    • 제14권11호
    • /
    • pp.1035-1047
    • /
    • 2005
  • By using hourly $NO_2$ concentration data$(1998\~2000)$ at the Busan Metropolitan City air qualify monitoring sites, characteristics of daily mean value of $NO_2$ concentration was discussed in space and time. The correlation between $NO_2$ concentration and other relating air pollutants was analyzed by using SAS program and meteorological parameters as well. After choosing representative 4 areas, this study used hourly concentration data$(1998\~2000)$ from air quality monitoring sites on $NO_2,\;NO,\;O_3,\;CO,\;SO_2\;and\;PM_{10}$. Typical metropolitan characteristics of two peaks in a day was shown in the variation of $NO_2$ concentration of Busan city.

해풍이 부산 지역의 대기 오염 농도에 미치는 영향 (The Influences of Sea Breeze on Air Pollution Concentration in Pusan, Korea)

  • 전병일;김유근;이화운
    • 한국환경과학회지
    • /
    • 제3권4호
    • /
    • pp.357-365
    • /
    • 1994
  • Air pollution characteristics and the influence of sea breeze on air pollution concentration were studied using the data measured at 7 air quality continuous monitoring stations in Pusan, 1993. Maximum air pollution concentration in Pusan was Gamjeondong for $SO_2$, Sinpyeongdong for TSP, Daeyeondong for $O_3, Kwangbokdong for $NO_2$, Beomcheondong for CO and all substances were under annual ambient air quality standards. Increased rate of concentration for sea breeze was 24.4% for 502, 31.5% for TSP, 8.0% fort $O_3, 26.7% for $NO_2$, 15.7% for CO. Frequencies distribution of $SO_2$, TSP, $O_3$, $NO_2$, and CO concentration for sea breeze moved toward high concentration class.

  • PDF

비색판별법을 이용한 콘크리트의 표면염화물량 산정 (A Study for the Calculation of the Surface Chloride on the concrete by using Colorimetric method)

  • 이진우;이문환;서치호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.815-820
    • /
    • 2001
  • This study is to set a new standard for using of the colorimetric method through grasping the character of the colorimetric method, and measuring the chloride concentration at the place of the change of color. Also, to predict chloride concentration around rebar and time reaching limit chloride concentration through measuring the chloride concentration of concrete surface by the colorimetric method and this study presents the new program of concrete degradation and diagnosis of the durability by salt damage. First the use of the colorimetric method was examinated, second the chloride concentration through slicing concrete submerged in artificial seawater for 6 months was measured. And the chloride concentration at the place of the change of color was calculated by using colorimetric method. Finally, the cloride concentration of the concrete surface was calculated.

  • PDF

콩을 이용한 식물filter에 의한 중금속 제거에 관한 연구 (Removal of Heavy Metals in Wastewater Using Glycine max Merr)

  • 나규환;김순진;신정식;최한영;이장훈
    • 한국환경보건학회지
    • /
    • 제23권1호
    • /
    • pp.105-108
    • /
    • 1997
  • For the removal of heavy metals, Cd, Cu and Cr were used. The initial concentration of Cd and Cu were 1-10 ppm, the removal efficiency of Cd and Cu was 76.2-89.0% and 69.0-79.0%, respectively. The initial concentration of Cr were 1~5 ppm, and the-removal efficiency was low especially at high concentration. In general, the initial concentrations of heavy metals had no relation to the removal efficiency. At the beginning, the removal efficiency was very high, but it was maintained at constant concentration. The trends of accumulations of heavy metals in the stem increased in proportion to the initial concentration. The removal efficiency of heavy metals increased a little bit when nutrients existed in the solution. So that, the initial concentration of Cd and Cu were 1-10 ppm, the removal efficiency of Cd and Cu was 84.8-91.0% and 75.9-82.0%. The initial concentration of Cr were 1-5 ppm, the removal efficiency was 25.0-67.0%.

  • PDF

압력 및 용존산소 농도가 활성슬러지에 미치는 영향 (Effects of Pressure and Dissolved Oxygen Concentration on the Activated Sludge)

  • 양병수;신현무
    • 한국환경과학회지
    • /
    • 제4권3호
    • /
    • pp.259-267
    • /
    • 1995
  • This study was conducted to evaluate the effects of pressure and dissolved oxygen concentration on the activated slut비e and to determine the optimum depth of deep shaft process. Some results from this study were summarized as follows. 1. It is considered that low sludge product in the activated sludge system maintaining high dissolved oxygen concentration is attributed to the increase of endogeneous respiration rate caused by the increase of aerobic zone in the sludge floe. 2. The increase of dissolved oxygen concentration does not affect to the increase of organic removal efficiency greatly and therefore the limiting factor is the substrate transfer into the inner part of floe. 3. The yield coefficient, Y is decreased in proportion to the increase of oxygen concentration. In this study, Y values arre ranged from 0.70 to 0.41 according to the variation of dissolved oxygen concentration from 18.0mg/$\ell$ to 258 mg/$\ell$. 4. The optimum depth of deep shaft process should be determined within the limits of non-toxicity to the microorganism and it is about loom in this study.

  • PDF

부산지역 여름철 고농도 오존 발생의 사례 연구 (Case Study for High Ozone Episode day during Summertime in Busan)

  • 전병일
    • 환경영향평가
    • /
    • 제12권4호
    • /
    • pp.303-313
    • /
    • 2003
  • This study was carried out to survey the high ozone episode of summertime in Busan. The selected day was July 18, 1999 and August 24, 2001 which recorded exceed to 12ppb/hr at 3 station in Busan simultaneously. In case July 18, 1999, thick cloud and variable wind made weak ozone concentration during morning hour. And increase of ozone concentration by revolution of mixed layer for morning hour did not occur in this case study day. Photochemical reaction by strong radiation after 1100LST made sharp increase rate of ozone concentration(50ppb/hr). In case August 24, 2001, the meteorological condition of this day was not general wind with gradient force, very clear day with less cloud amount, high insolation and sunshine. Dongsamdong, Beomcheondong, Daeyeondong, and Sinpyeongdong had double peak which twice maximum concentration in the early afternoon and late afternoon. Ozone concentration of this day was in inverse proportion to Nitrogen oxide strongly. Ozone concentration exceed to 60ppb/hr occurred at 1400LST, continued to 2300LST.

체외순환에 따른 혈장 단백 함량과 폐포모세혈관 산소 분압차의 변화 (Changes in Plasma Protein Concentration and Alveolar -Arterial Oxygen Tension Differnce Associated with CPB-)

  • 전태국
    • Journal of Chest Surgery
    • /
    • 제23권6호
    • /
    • pp.1084-1089
    • /
    • 1990
  • Plasma protein concentration, plasma albumin concentration, hematocrit, and arterial blood gas tension were measured in 15 mongrel dogs undergoing heart transplantation with cardiopulmonary bypass. The hemodilution due to priming solution resulted in a 49% decrease in plasma protein concentration, a 57% decrease in plasma albumin concentration, a 46%a decrease in hematocrit. The measurements had returned to preperfusion values 1 hour after the end of cardiopulmonary bypass. The intraoperative changes in plasma protein and albumin concentration did not correlate with changes in alveolar-arterial oxygen tension gradients[D[A\ulcorner PO2]]. It is concluded that, in the absence of an increase in left atrial pressure, marked decrease in plasma protein concentration can be tolerated without the occurrence of pulmonary edema. And further study should be done to determine how to prepare an ideal priming solution.

  • PDF