• Title/Summary/Keyword: Concentrated Wastewater

Search Result 107, Processing Time 0.021 seconds

Effective Treatment of Wastewater from the Electroplating Plant of Cold-mill by using Microorganism (냉연공장 도금공정에서 발생되는 폐수의 효율적인 미생물 처리에 관한 연구)

  • Kim, Sang-Sik;Kim, Hyung-Jin
    • Applied Chemistry for Engineering
    • /
    • v.20 no.3
    • /
    • pp.301-306
    • /
    • 2009
  • This research was carried out to establish the effective treatment condition and characteristic of wastewater from the electroplating plant of cold rolling mill by using microorganism. Alkaline wastewater and acidic heavy metal wastewater accounted for 64%, 30%, respectively, of the total wastewater. Highly concentrated thiocyanate was 53890 mg/L as COD and it was 53% of total COD, even though it was 0.03% of wastewater from the electroplating plant. When treating mixed wastewater with microorganism, it was easy to remove when SCN concentrations of mixed wastewater was 200 mg/L or less. While the treatment effect of COD-causing materials was low at the concentration of 400 mg/L or less, it implies that highly concentrated thiocyanate contains a large amount of slowly biodegradable organics. When treating with mixed wastewater, pH was 7.33 at the beginning, but after 8 hours it increased to 7.99. This is caused by ammonia which is generated when SCN of highly concentrated thiocyanate was degraded by microorganism.

A Study on the Solid-Liquid Separation Characteristics for Highly Concentrated Swine Wastewater Using Model Decanter (모델 데칸트를 이용한 고농도 슬러리상태 양돈폐수의 고액분리특성에 관한 연구)

  • Na, Eun-Su;Gang, Ho
    • 연구논문집
    • /
    • s.30
    • /
    • pp.67-77
    • /
    • 2000
  • This study was performed to investigate the characteristics and performance of model Decanter for separating swine wastewater to solid and liquid which is slurry state with 12.6% TS. Swine wastewater of the slurry tank was pumped into model Decanter which capacity was $2m^3$/hr in 10% TS Slurry inside of bowl was separated to solid-liquid by centrifugal acceleration. Sampling was done in the section of slurry feed pipe, supernatant outflow pipe, cake discharge pipe. After solid-liquid separation TS, $COD_cr$ and slurry volume reduction effect represented 38%, 40%, 19.6% respectively. Relation factor of model Decanter operation slurry concentration, optimum retention time of slurry, overflow velocity of supernatant, supernatant concentration, sludge removal rate etc. Optimal operation conditions can be set and evaluated efficiency based on the experimental results in the case of Decanter adopted for solid-liquid separation in highly concentrated swine wastewater.

  • PDF

Study of Inorganic Photocatalyst Media for Reused Wastewater (폐수 재이용을 위한 무기계 광촉매 담체 연구)

  • Lee, Gyuyoung;Kim, Jungchul;Lim, Jihyun;Lee, Junwoo;Park, Jeongmi;Lee, Seunghun;Nam, Jukyung;Lee, Yong-Woo
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.1
    • /
    • pp.42-48
    • /
    • 2015
  • This study focused on effective decomposition methods for low concentrated organic compounds from the reuse of industrial wastewater, and confirmed the possibility through photocatalyst media. Photocatalyst immobilized media was developed to carry on this experiment which confirmed the removal possibility of low concentrated organic compounds. Considering the stability and efficiency of photocatalyst immobilization, inorganic support, hollow bead, and $TiO_2$ nano powder were used. As a result of the removal experiment, the removal efficiencies of acetonitrile, ethanol, IPA(Isopropyl alcohol), methanol were above 75% after 15 minutes while those of acetone, acetaldehyde, urea were 10%, 45%, 20%, respectively after 60 minutes. If further studies were made to increase the surface area of the photocatalyst immobilized media, the efficiency of the removal of low concentrated organic compounds can be improved and this solution can also be used in an actual treatment process.

Optimal Treatment of Molasses Wastewater Using UASB Process (UASB 공정에 의한 당밀폐수의 최적처리 방안)

  • Huh, Kwan-Yong;Jeong, Eui-Geun;Chung, Yoon-Jin;Yoo, Sang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.2
    • /
    • pp.112-127
    • /
    • 1997
  • The purpose of this study is to get optimum operating factors of Upflow Anaerobic Sludge Blanket (UASB) reactor by introducing methods that make it to reduce inhibition possible in each process wastewater treatment. The used substrates, concentrated corn starch liquid (CSL) wastewater, modified starch, filtering and decoloring wastewater, ion refining wastewater, and mixed wastewater including modified starch and not including modified starch, are generated from molasses process. The seeding sludge is the digested sludge that had been applied to molasses wastewater. Batch test to reduce the inhibition factors that might be existed in each wastewater was examined. Based on the this test, the optimum operating factors according to alkalinity and pH variation was studied through the continuous test using three 5.5 L UASB reactor. The first reactor added $NaHCO_3$ to control alkalinity. The hydraulic retention time (HRT) reduced to 8 hours and the organic loading rate increased gradually. The second reactor changed the pH of influent from 7.0 to 6.0 using NaOH. The third reactor was operated without changes to compare the above two reactors. As the result, the inhibition in concentrated CSL wastewater was removed by adding iron (II). When trace metals were added to mixed wastewater not including modified starch, the digestability by gas production rate increased to more fifty percentage than mixed wastewater that was not adding the trace metals. The reason that the inhibition did not decreased in spite of adding trace metals and nutrients was influenced by high concentration generated during the acid fermentation. The UASB reactors using the mixed wastewater with the most effective performance were operated as 500 mg/L as $CaCO_3$ alkalinity and 6.0 pH at steady state, and at this time, the gas production rates were 283 and 311mL gas/g $COD_{added}$. The COD removal rates were 84.7 and 86.3%, respectively.

  • PDF

Treatment of Oily Wastewater with WPO and CWO

  • Han, Mei;Chen, Yihui;He, Fang;Yu, Li
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.1
    • /
    • pp.68-71
    • /
    • 2014
  • Petroleum refining unavoidably generates large volumes of oily wastewater. The environmentally acceptable disposal of oily wastewater is a current challenge to the petroleum industry. Nowadays, more attentions have been focused on the treatment techniques of oily wastewater. Oily wastewater contained highly concentrated and toxic organic compounds. Wet peroxide oxidation (WPO) and catalytic wet oxidation (CWO) were applied to eliminate pollutants to examine the feasibility of the WPO/CWO of oily wastewater. The results indicated that more than 80% chemical oxygen demand (COD) removal from oily wastewater was achieved with CWO. Homogenous catalyst, $NaHCO_3$ and $Na_2CO_3$ and NaOH showed effective removal for pollutants in oily wastewater. Greater than 90% COD removal was achieved with WPO. It was concluded that WPO was a far more effective process for oily wastewater.

A Study on the Treatment of Wastewater from the Weight-Reduction Process of Polyester (폴리에스테르 감량가공(減量加工) 폐수(廢水)의 최적(最適) 처리방안(處理方案)에 관한 연구(硏究))

  • Chung, Yoon Jin;Yang, Tae Du;Kim, Woong Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.7 no.1
    • /
    • pp.20-28
    • /
    • 1993
  • The Wastewater from the weight reduction process of polyester is more difficult to be treated biologically than the general wastewater from dyeing and finishing processes in textile industries. Above wastewater shows high pH, high organic strength and wide variation of organic loading. These characteristics are due to TPA and EG resulting from alkaline weight-reduction process and make trouble in the operation of activated sludge process. Therefore, the objective of this study is to develop the pretreatment method for the successful operation of treatment process. For the successful pretreatment process, the wastewater from weight-reduction process should be segregated from other wastewater stream and then acidified with concentrated sulfuric acid to precipitate out TPA from DST solution. At the optimum pH of 2. 2, the initial $COD_{cr}$ 60,000mg/l is reduced to 11,500mg/l and the removal efficiency of $COD_{cr}$ is 81.1%. The required amount of sulfuric acid for pretreatment is not greater than the amount for the the existing neutralization process. Moreover, the supernatant of pretreatment process can be reused in acidification of wastewater.

  • PDF

Comparison of Bacterial Numbers and Treatment Efficiencies in Bioreactors of Various Advanced Wastewater Treatment Processes (다양한 고도폐수처리공정에서의 생물반응조 세균수와 처리효율과의 비교)

  • Sung, Gi Moon;Cho, Yeon-Je;Kim, Sung Kyun;Park, Eun Won;Yu, Ki Hwan;Lee, Sang-Hyeon;Lee, Dong-Geun;Park, Seong Joo
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.2
    • /
    • pp.329-334
    • /
    • 2009
  • Bacterial numbers, such as endospore-formers, and treatment efficiencies were investigated for Rotating Activated Bacillus Contactors (RABC) and other advanced wastewater treatment processes including anaerobic-anoxic-oxic (A2O), sequencing batch reactor (SBR) and biological aerated filter (BAF). Endospore-forming bacterial numbers in the RABC showed 129-fold higher levels than those of the existing advanced systems. RABC process demonstrated the highest bacterial numbers in its bioreactors (paired t-test, p<0.01). RBC biofilms and aeration tanks of the RABC system showed 131- and 476-fold higher than other existing advanced processes, respectively. Mean treatment efficiencies of the existing systems were 83.5% for chemical oxygen demand (COD), 59.1% for total nitrogen (TN) and 76.8% for total phosphorus (TP). However, RABC process removed 96.9% for COD, 96.9% for TN and 91.9% for TP for highly concentrated food wastewater (COD>1,500 mg/L, TN>150 mg/L, TP>50 mg/L). Treatment efficiency was significantly reduced when the numbers of Bacillus genus in the bioreactors decreased below $10^6CFU/mL$. The automated RABC (A-RABC), in which dissolved oxygen concentrations are automatically controlled, showed higher treatment efficiencies compared to the RABC process. The RABC system maintained sufficient bacterial numbers for the effective treatment of highly concentrated food wastewater. Moreover, final effluent was in agreement to water quality standards.

Treatment of Paper Mill Wastewater by the Deep Shaft Activated Sludge Process (심층폭기(深層曝氣) 활성(活性)슬러지법(法)을 이용(利用)한 제지폐수(製紙廢水)의 생물학적(生物學的) 처리(處理)에 관한 연구(研究))

  • Kim, Hwan Gi;Yang, Bong Yong;Lee, Bok Yul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.275-284
    • /
    • 1992
  • A generated problem in treated highly concentrated organic wastewater by activated sludge process is the limitation of biomass concentration and oxygen transfer capability in aeration tank. To overcome the limitation, the deep shaft activated sludge process which has high oxygen transfer capability was applied to the wastewater treatment process. This paper investigated the characteristics of liquid circulation, oxygen transfer and biological treatment of paper mill wastewater by the deep shaft activated sludge process. From the obtained results, it was found that the oxygen transfer capability in the deep shaft system was much greater than those in the conventional aeration systems and almost tantamount to the pure oxygen system. The deep shaft system could treat highly concentrated organic wastewater by higher biomass concentration and organic loading rate.

  • PDF

Fluoride Wastewater Treatment using Waste Concrete Powder (폐콘크리트분말을 이용한 불산폐수 처리)

  • Kim, Eun-I;Kang, Wan-Hyup;Park, Joo-Yang
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.2
    • /
    • pp.125-134
    • /
    • 2005
  • Waste concrete powder was used to remove fluoride ions in highly concentrated fluoride wastewater. 92.6% of fluoride in 100 mg F/L wastewater was removed by 1% dose of the cement paste powder that represents characteristics of waste concrete powder, whereas the removal efficiencies of raw cement and lime were 47.3% and 96.4%, respectively. The cement paste powder was competitive to lime, common fluoride removal agent. Various Ca-bearing hydrates such as portlandite, calcium silicate hydrate, and ettringite in cement paste slurry can remove fluoride by precipitating $CaF_2$ and absorbing $F^-$ ions. In the experiments using both cement paste and lime, 50~67% of lime can be substituted by cement paste to satisfy fluoride effluent limitation of 15 mg/L. Since cement paste has higher acid neutralization capacity than lime, it can be recycled to neutralize more acid and to remove more fluoride. Therefore waste concrete powder can be more economical and viable alternative for lime in fluoride wastewater treatment.

The System of Sewage and Domestic Wastewater Treatment Plants in Tan-Sui River Basin

  • Ko, Chun-Han
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.26.2-39
    • /
    • 2002
  • Tan-Sui River Basin covers Taipei metropolitan area of 2,726 square kilometers with more than six million residents. Since 1988, Taiwan government started to plan and construct an integrated sewerage system, consisted by both separated and concentrated trunk sewers, wastewater treatment plants and ocean outfalls. This presentation will introduce the master plan and major facilities of Tan-Sui River Basin sewerage system. Other measures to protect general water quality and the environment of adjacent river basin area of Tan-Sui River and her tributaries by Taiwan EPA will be presented as well.

  • PDF