• Title/Summary/Keyword: Computerized tomography

Search Result 338, Processing Time 0.027 seconds

Augmented Reality to Localize Individual Organ in Surgical Procedure

  • Lee, Dongheon;Yi, Jin Wook;Hong, Jeeyoung;Chai, Young Jun;Kim, Hee Chan;Kong, Hyoun-Joong
    • Healthcare Informatics Research
    • /
    • v.24 no.4
    • /
    • pp.394-401
    • /
    • 2018
  • Objectives: Augmented reality (AR) technology has become rapidly available and is suitable for various medical applications since it can provide effective visualization of intricate anatomical structures inside the human body. This paper describes the procedure to develop an AR app with Unity3D and Vuforia software development kit and publish it to a smartphone for the localization of critical tissues or organs that cannot be seen easily by the naked eye during surgery. Methods: In this study, Vuforia version 6.5 integrated with the Unity Editor was installed on a desktop computer and configured to develop the Android AR app for the visualization of internal organs. Three-dimensional segmented human organs were extracted from a computerized tomography file using Seg3D software, and overlaid on a target body surface through the developed app with an artificial marker. Results: To aid beginners in using the AR technology for medical applications, a 3D model of the thyroid and surrounding structures was created from a thyroid cancer patient's DICOM file, and was visualized on the neck of a medical training mannequin through the developed AR app. The individual organs, including the thyroid, trachea, carotid artery, jugular vein, and esophagus were localized by the surgeon's Android smartphone. Conclusions: Vuforia software can help even researchers, students, or surgeons who do not possess computer vision expertise to easily develop an AR app in a user-friendly manner and use it to visualize and localize critical internal organs without incision. It could allow AR technology to be extensively utilized for various medical applications.

Midfacial soft tissue changes after maxillary expansion using micro-implant-supported maxillary skeletal expanders in young adults: A retrospective study

  • Nguyen, Hieu;Shin, Jeong Won;Giap, Hai-Van;Kim, Ki Beom;Chae, Hwa Sung;Kim, Young Ho;Choi, Hae Won
    • The korean journal of orthodontics
    • /
    • v.51 no.3
    • /
    • pp.145-156
    • /
    • 2021
  • Objective: The aim of this retrospective study was to assess the midfacial soft tissue changes following maxillary expansion using micro-implant-supported maxillary skeletal expanders (MSEs) in young adults by cone-beam computerized tomography (CBCT) and to evaluate the correlations between hard and soft tissue changes after MSE usage. Methods: Twenty patients (mean age, 22.4 years; range, 17.6-27.1) with maxillary transverse deficiency treated with MSEs were selected. Mean expansion amount was 6.5 mm. CBCT images taken before and after expansion were superimposed to measure the changes in soft and hard tissue landmarks. Statistical analyses were performed using paired t-test and Pearson's correlation analysis on the basis of the normality of data. Results: Average lateral movement of the cheek points was 1.35 mm (right) and 1.08 mm (left), and that of the alar curvature points was 1.03 mm (right) and 1.02 mm (left). Average forward displacement of the cheek points was 0.59 mm (right) and 0.44 mm (left), and that of the alar curvature points was 0.61 mm (right) and 0.77 mm (left) (p < 0.05). Anterior nasal spine (ANS), posterior nasal spine (PNS), and alveolar bone width showed significant increments (p < 0.05). Changes in the cheek and alar curvature points on both sides significantly correlated with hard tissue changes (p < 0.05). Conclusions: Maxillary expansion using MSEs resulted in significant lateral and forward movements of the soft tissues of cheek and alar curvature points on both sides in young adults and correlated with the maxillary suture opening at the ANS and PNS.

Implementation of 3D Video using Time-Shortening Algorithm (시간단축 알고리즘을 통한 3D 동영상 구현)

  • Shin, Jin-Seob;Jeong, Chan-Woong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.123-128
    • /
    • 2020
  • In this paper, we presents a new cone beam computerized tomography (CBCT) system for the reconstruction of 3 dimensional dynamic images. The system using cone beam has less the exposure of radioactivity than fan beam, relatively. In the system, the reconstruction 3-D image is reconstructed with the radiation angle of X-ray in the image processing unit and transmitted to the monitor. And in the image processing unit, the Three Pass Shear Matrices, a kind of Rotation-based method, is applied to reconstruct 3D image because it has less transcendental functions than the one-pass shear matrix to decrease a time of calculations for the reconstruction 3-D image in the processor. The new system is able to get 3~5 3-D images a second, reconstruct the 3-D dynamic images in real time. And we showed the Rotation-based method was good rather than existing reconstruction technique for 3D images, also found weakness and a solution for it.

Comparison of the Effects of PNF Neck Flexion and Curl-up Exercises on Abdominal Muscle Activity, Trunk Control, and Balance in Chronic Stroke Patients (PNF 목 굽힘 운동과 Curl-up 운동이 만성 뇌졸중 환자의 배근육의 활성도와 몸통 조절 및 균형에 미치는 효과 비교)

  • Kim, Gyeong-Don;Kim, Hyeon-Su
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.4
    • /
    • pp.171-181
    • /
    • 2020
  • Purpose : The purpose of this study was to investigate the effects of curl-up and proprioceptive neuromuscular facilitation (PNF) neck flexion exercises on stroke patients' trunk muscle activity, ability to control the trunk, and balance by comparing two exercise methods. Methods : The study involved patients who had been diagnosed with stroke based on the results of computerized tomography or magnetic resonance imaging at O Hospital in Daegu, South Korea, between January and July 2020. In total, 30 subjects were selected and by flipping a coin, randomly assigned to an experimental group (n=15) that performed PNF neck flexion exercises and a control group (n=15) that performed curl-up exercises. Both groups received traditional rehabilitation therapy for 30 minutes a day five times a week for a six-week period. In addition, the experimental group performed PNF neck flexion exercises and the control group curl-up exercises for 15 minutes a day five times a week over the same period. The subjects' muscle activity in the rectus abdominis (RA), external oblique (EO), and internal oblique (IO) were measured before and after the experiment. The subjects' trunk impairment scale (TIS) and Berg balance scale (BBS) scores were also assessed. Paired t test was performed to measure the amount of statistical change before and after intervention in both groups. An independent sample T test was performed to measure the amount of statistical change between the two groups. Results : Both groups experienced statistically significant increases in their RA, IO and EO muscle activity, total TIS scores, and total BBS scores after the intervention. No statistically significant differences in the changes before and after the intervention were found for any of the resulting values between the two groups. Conclusion : A comprehensive review of the study's results suggested that neck flexion exercises using the PNF irradiation concept and curl-up exercise are effective in increasing stroke patients' abdominal muscle activity and improving trunk control ability and balance in chronic stroke patients.

Fiber orientation distribution of reinforced cemented Toyoura sand

  • Safdar, Muhammad;Newson, Tim;Waseem, Muhammad
    • Geomechanics and Engineering
    • /
    • v.30 no.1
    • /
    • pp.67-73
    • /
    • 2022
  • In this study, the fiber orientation distribution (FOD) is investigated using both micro-CT (computerized tomography) and image analysis of physically cut specimens prepared from Polyvinyl Alcohol (PVA) fiber reinforced cemented Toyoura sand. The micro-CT images of the fiber reinforced cemented sand specimens were visualized in horizontal and vertical sections. Scans were obtained using a frame rate of two frames and an exposure time of 500 milliseconds. The number of images was set to optimize and typically resulted in approximately 3000 images. Then, the angles of the fibers for horizontal sections and in vertical section were calculated using the VGStudio MAX software. The number of fibers intersecting horizontal and vertical sections are counted using these images. A similar approach was used for physically cut specimens. The variation of results of fiber orientation between micro-CT scans and visual count were approximately 4-8%. The micro-CT scans were able to precisely investigate the fiber orientation distribution of fibers in these samples. The results show that 85-90% of the PVA fibers are oriented between ±30° of horizontal, and approximately 95% of fibers have an orientation that lies within ±45° of the horizontal plane. Finally, a comparison of experimental results with the generalized fiber orientation distribution function 𝜌(θ) is presented for isotropic and anisotropic distribution in fiber reinforced cemented Toyoura sand specimens. Experimentally, it can be seen that the average ratio of the number of fibers intersecting the finite area on a vertical plane to number of fibers intersecting the finite area on a horizontal plane (NVtot/NHtot) cut through a sample varies from 2.08 to 2.12 (an average ratio of 2.10 is obtained in this study). Based up on the analytical predictions, it can be seen that the average NVtot/NHtot ratio varies from 2.13 to 2.17 for varying n values (an average ratio of 2.15).

The Study on the Implementation of the X-Ray CT System Using the Cone-Beam for the 3D Dynamic Image Acquisition (3D 동영상획득을 위한 Cone-Beam 형 X-Ray CT 시스템 구현에 관한 연구)

  • Jeong, Chan-Woong;Jun, Kyu-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.370-374
    • /
    • 2009
  • In this paper, we presents a new cone beam computerized tomography (CB CT) system for the reconstruction of 3 dimensional dynamic images. The system using cone beam has less the exposure of radioactivity than fan beam, relatively. In the system, the reconstruction 3-D image is reconstructed with the radiation angle of X-ray in the image processing unit and transmitted to the monitor. And in the image processing unit, the Three Pass Shear Matrices, a kind of Rotation-based method, is applied to reconstruct 3D image because it has less transcendental functions than the one-pass shear matrix to decrease a time of calculations for the reconstruction 3-D image in the processor. The new system is able to get 3~5 3-D images a second, reconstruct the 3-D dynamic images in real time.

The Algorithm Improved the Speed for the 3-Dimensional CT Video Composition (3D CT 동영상 구성을 위한 속도 개선 알고리즘)

  • Jeong, Chan-Woong;Park, Jin-Woo;Jun, Kyu-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.141-147
    • /
    • 2009
  • This paper presents a new fast algorithm, rotation-based method (RBM), for the reconstruction of 3 dimensional image for cone beam computerized tomography (CB CT) system. The system used cone beam has less exposure time of radioactivity than fan beam. The Three-Pass Shear Matrices (TPSM) is applied, that has less transcendental functions than the one-pass shear method to decrease a time of calculations in the computer. To evaluate the quality of the 3-D images and the time for the reconstruction of the 3-D images, another 3-D images were reconstructed by the radon transform under the same condition. For the quality of the 3-D images, the images by radon transform was shown little good quality than REM. But for the time for the reconstruction of the 3-D images REM algorithm was 35 times faster than radon transform. This algorithm offered $4{\sim}5$ frames a second. It meant that it will be possible to reconstruct the 3-D dynamic images in real time.

Evaluation on Usefulness of Stereotactic Radio Surgery using $Fraxion^{(R)}$ System ($Fraxion^{(R)}$ System을 이용한 뇌 정위적 방사선 수술 유용성 평가)

  • Kim, Tae Won;Park, Kwang Woo;Ha, Jin Sook;Jeon, Mi Jin;Cho, Yoon Jin;Kim, Sei Joon;Kim, Jong Dae;Shin, Dong Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.345-354
    • /
    • 2014
  • Purpose : We evaluated the usefulness of $Fraxion^{(R)}$ system and s-thermoplastic mask by analyzing setup error when stereotactic radiousurgery (SRS) was treated for brain metastasis. Materials and Methods : 6 patients who received definite diagnosis as brain metastasis between May 2014 and October 2014 were selected. 3 patients were immobilized s-thermoplastic mask and mouthpiece (group1), while $Fraxion^{(R)}$ system was used for the other 3 patients (group2). Cone Beam Computerized Tomography (CBCT) scan was acquired to register planning CT scan. The registration offset was compared for each group. We compared and reported the errors using maximum, minimum, mean, and standard deviation of registration offsets. Furthermore, We used the same method as patient specific quality assurance to verify absorbed dose of PTV. Results : The setup error which is registration offset was reduced 83% in x, 40% in y, and 92% in z-direction when $Fraxion^{(R)}$ system was used compared to the case of using s-thermoplastic mask and mouthpiece. In addition, using $Fraxion^{(R)}$ system showed improved results in rotational components, pitch (rotation along x-axis), roll (y), and yaw (z) which were reduced 64, 88, and 87% respectively compared to the case of using s-thermoplastic mask and mouthpiece. In dosimetry results, when s-thermoplastic mask and mouthpiece used, absorbed dose was reduce 83% compared to before and after registration. However, using $Fraxion^{(R)}$ system showed only 1.9%. All percentage were calculated with respect to average value. Conclusion : Using $Fraxion^{(R)}$ system including mouthpiece, Fraxion frame, frontpiece, and thermoplastic mask, showed better repeatability and precision compared to using s-thermoplastic mask and mouthpiece, which is consequently considered as more improved immobilization system.

A Study on Usefulness of Clinical Application of Metal Artifact Reduction Algorithm in Radiotherapy (방사선치료 시 Metal artifact reduction Algorithm의 임상적용 유용성평가)

  • Park, Ja Ram;Kim, Min Su;Kim, Jeong Mi;Chung, Hyeon Suk;Lee, Chung Hwan;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.9-17
    • /
    • 2017
  • Purpose: The tissue description and electron density indicated by the Computed Tomography(CT) number (also known as Hounsfield Unit) in radiotherapy are important in ensuring the accuracy of CT-based computerized radiotherapy planning. The internal metal implants, however, not only reduce the accuracy of CT number but also introduce uncertainty into tissue description, leading to development of many clinical algorithms for reducing metal artifacts. The purpose of this study was, therefore, to investigate the accuracy and the clinical applicability by analyzing date from SMART MAR (GE) used in our institution. Methode: and material: For assessment of images, the original images were obtained after forming ROIs with identical volumes by using CIRS ED phantom and inserting rods of six tissues and then non-SMART MAR and SMART MAR images were obtained and compared in terms of CT number and SD value. For determination of the difference in dose by the changes in CT number due to metal artifacts, the original images were obtained by forming PTV at two sites of CIRS ED phantom CT images with Computerized Treatment Planning (CTP system), the identical treatment plans were established for non-SMART MAR and SMART MAR images by obtaining unilateral and bilateral titanium insertion images, and mean doses, Homogeneity Index(HI), and Conformity Index(CI) for both PTVs were compared. The absorbed doses at both sites were measured by calculating the dose conversion constant (cCy/nC) from ylinder acrylic phantom, 0.125cc ionchamber, and electrometer and obtaining non-SMART MAR and SMART MAR images from images resulting from insertions of unilateral and bilateral titanium rods, and compared with point doses from CTP. Result: The results of image assessment showed that the CT number of SMART MAR images compared to those of non-SMART MAR images were more close to those of original images, and the SD decreased more in SMART compared to non-SMART ones. The results of dose determinations showed that the mean doses, HI and CI of non-SMART MAR images compared to those of SMART MAR images were more close to those of original images, however the differences did not reach statistical significance. The results of absorbed dose measurement showed that the difference between actual absorbed dose and point dose on CTP in absorbed dose were 2.69 and 3.63 % in non-SMRT MAR images, however decreased to 0.56 and 0.68 %, respectively in SMART MAR images. Conclusion: The application of SMART MAR in CT images from patients with metal implants improved quality of images, being demonstrated by improvement in accuracy of CT number and decrease in SD, therefore it is considered that this method is useful in dose calculation and forming contour between tumor and normal tissues.

  • PDF

Clinical Characteristics of Orbital Cellulitis in Children (소아 안와 연조직염의 임상적 고찰)

  • Lee, Yong Ju;Choi, Kyoung Min;Kim, Dong Soo
    • Pediatric Infection and Vaccine
    • /
    • v.12 no.2
    • /
    • pp.178-185
    • /
    • 2005
  • Purpose : Ocular adnexal and orbital infections are broadly divided into preseptal(periorbital) and postseptal(orbital) cellulitis by orbital septum. In this study, we investigated the difference between periorbital and orbital cellulitis regarding their pathogenesis, clinical manifestations, treatments, and prognosis. Methods : We reviewed medical records of 50 cases who were hospitalized in the Severance hospital due to orbital cellulitis from May 1995 to April 2004. Results : There were 32 males and 18 females. The mean age was $3.2{\pm}3.5$ year. According to the result of orbital computerized tomography, 36 cases were periorbital cellulitis, 10 cases orbital cellulitis and 4 cases not diagnosed. The clinical manifestations of periorbital cellulitis are periorbital swelling(100%), fever(19%), orbital pain(6%), and chemosis(22%). On the other hand, those of orbital cellulitis are periorbital swelling(100%), fever(80%), orbital pain(60%), proptosis(20%), chemosis(70%) and limitation of eye movement(20%). The etiologies of periorbital cellulitis are sinusitis(14%), upper respiratory infection(8%), conjunctivitis (19%), skin wound(14%) and unknown(44%). The etiologies of orbital cellulitis are sinusitis (50%), upper respiratory infection(20%), and unknown(30%). The first line antibiotics used in the majority of cases were combinations of cefoxitin+aminoglycoside. 5 patients with orbital cellulitis taking cefoxitin+aminoglycoside had to change the medication into vancomycin or clindamycin. 3 patients with orbital cellulitis underwent operation while 1 patient developed bacterial meningitis. Conclusion : According to invasion of orbit, ocular adnexal and orbital infections are quite different in their pathogenesis, treatment and prognosis. As atypical cases may confound the diagnosis, prompt orbital computerized tomography is required for an accurate diagnosis.

  • PDF