• Title/Summary/Keyword: Computer-aided Research

Search Result 514, Processing Time 0.021 seconds

Study on the Plotting of Engineering Survey Plane Using Computer Graphic System (Computer Graphic System을 이용한 선상시설물(線狀施設物) 측량(測量)의 설계도면작성(設計圖面作成)에 관한 연구(研究))

  • Yeu, Bock Mo;Bang, Cheon Ho;Choi, Chul Soon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.3 no.2
    • /
    • pp.61-72
    • /
    • 1983
  • This paper is a study on the plotting of engineering survey plan using Computer Graphic System. This study aims for a more systematic method in the computer aided design. Plotting of lines, characters in engineering survey plans are handled in a more systematic and effective way by means of the program developed in this paper.

  • PDF

Call for a Computer-Aided Cancer Detection and Classification Research Initiative in Oman

  • Mirzal, Andri;Chaudhry, Shafique Ahmad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.5
    • /
    • pp.2375-2382
    • /
    • 2016
  • Cancer is a major health problem in Oman. It is reported that cancer incidence in Oman is the second highest after Saudi Arabia among Gulf Cooperation Council countries. Based on GLOBOCAN estimates, Oman is predicted to face an almost two-fold increase in cancer incidence in the period 2008-2020. However, cancer research in Oman is still in its infancy. This is due to the fact that medical institutions and infrastructure that play central roles in data collection and analysis are relatively new developments in Oman. We believe the country requires an organized plan and efforts to promote local cancer research. In this paper, we discuss current research progress in cancer diagnosis using machine learning techniques to optimize computer aided cancer detection and classification (CAD). We specifically discuss CAD using two major medical data, i.e., medical imaging and microarray gene expression profiling, because medical imaging like mammography, MRI, and PET have been widely used in Oman for assisting radiologists in early cancer diagnosis and microarray data have been proven to be a reliable source for differential diagnosis. We also discuss future cancer research directions and benefits to Oman economy for entering the cancer research and treatment business as it is a multi-billion dollar industry worldwide.

SDL: A New CAGD Library for Conputer-Aided Ship Design

  • Koras, George D.;Kaklis, Panagiotis D.;Papanikolaou, Apostolos D.
    • Journal of Ship and Ocean Technology
    • /
    • v.5 no.4
    • /
    • pp.1-18
    • /
    • 2001
  • Software written in academic environments is rarely integrated and/or reused. Moreover, typical academic software products do not communicate with commercial CAD packages, consequently functionality that is readily available to industry is not available do academic researchers. The Surface Design Library (SDL) is a library serving as a framework under which, CAGD software, intended for research or educational use, can be written in such a manner that it becomes a reusable part of a useful CAGD system. Moreover SDL is equipped with an IGES translator so that it communicates with commercial CAD packages, This paper gives a brief overview to SDL and presents examples of using it for high quality fairing performed on a naval ship hull, before employing commercial CAD packages for further design and analysis.

  • PDF

Direct-Projected Augmented Reality Interface for Marking Surgical Targets in Computer Aided Surgery (컴퓨터 기반 수술시 환부표시를 위한 직접투사형 증강현실 인터페이스)

  • Seo, Byung-Kuk;Kang, Gap-Chul;Park, Jong-Il
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.786-790
    • /
    • 2007
  • Up to now, surgeons have operated while peering at images which visualize the medical state of the patient such as MRI or CT images. On the other hand, direct-projected augmented reality technology liberates surgeons from the inconvenience by directly projecting medical information onto the patient's body. However surgeons still feel inconvenient when they mark surgical targets for planning an operation because they use an ink pen which is difficult to modify or delete and is also likely to be unsanitary. In this paper, we resolve these problems by proposing an interactive user interface based on direct-projected augmented reality technology and its validity is shown in experimental results.

소형전산기를 이용한 재고관리 시뮤레이션 모델 연구

  • Kim Yeong-Gil
    • Journal of the military operations research society of Korea
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 1985
  • A computer-aided simulation model for inventory control was developed using Apple II Plus micro-computer. The model forecasts quarterly demands with Single Exponential Smoothing method and simulates Supply Demand Review and Inventory Level Settings for each items. The simulation is based on the assumption that the demand occurrences have their own probability distributions.

  • PDF

A Digitally Designed All-on-4 Restoration with Screwmentable Concept

  • Park, Koungjin;Han, Jung-Suk;Lee, Jae-Hyun
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.84-91
    • /
    • 2022
  • An all-on-4 restoration allows edentulous patients to use a fixed prosthesis with a minimum number of implants. These implant-supported fixed complete dentures have traditionally been fabricated as screw-retained or cement-retained prostheses. However, it is difficult to passively fit the long-span full-arch prosthesis using the screw-retained type restoration, and predictable retrievability is not obtained with the cement-retained type. This case report describes a prosthesis fabricated using a combination of the two retention types. The screwmentable method allows the implant-supported fixed complete denture to achieve a passive fit at the connection with retrievability. In addition, a framework with an optimized size was designed by using digital dental technology.

Immediate Loading of Narrow Diameter Implants at the Mandibular Incisor Area Using Full Digital Flow: A Case Report

  • Ahn, Ji Ho;Lim, Young-Jun;Baek, Yeon-Wha;Lee, Jungwon
    • Journal of Korean Dental Science
    • /
    • v.15 no.1
    • /
    • pp.92-99
    • /
    • 2022
  • This case report describes the immediate loading of narrow diameter implants in the mandibular incisor area using full-digital flow. The 3-dimensional position of the implants was planned using digital software, and the corresponding surgical template was fabricated. The implants were inserted immediately after extraction and on the same day, the interim abutment and bridge were placed. At 8 weeks after surgery, the stability of the implants was measured and a digital impression was made using a scan body. Customized titanium abutments and a cement-type full zirconia bridge were delivered. At 36 weeks' follow-up, no clinical or radiographic complications were detected, and the patient was satisfied with the results.

Wear of 3D printed and CAD/CAM milled interim resin materials after chewing simulation

  • Myagmar, Gerelmaa;Lee, Jae-Hyun;Ahn, Jin-Soo;Yeo, In-Sung Luke;Yoon, Hyung-In;Han, Jung-Suk
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.3
    • /
    • pp.144-151
    • /
    • 2021
  • PURPOSE. The purpose of this in vitro study was to investigate the wear resistance and surface roughness of three interim resin materials, which were subjected to chewing simulation. MATERIALS AND METHODS. Three interim resin materials were evaluated: (1) three-dimensional (3D) printed (digital light processing type), (2) computer-aided design and computer-aided manufacturing (CAD/CAM) milled, and (3) conventional polymethyl methacrylate interim resin materials. A total of 48 substrate specimens were prepared. The specimens were divided into two subgroups and subjected to 30,000 or 60,000 cycles of chewing simulation (n = 8). The wear volume loss and surface roughness of the materials were compared. Statistical analysis was performed using one-way analysis of variance and Tukey's post-hoc test (α=.05). RESULTS. The mean ± standard deviation values of wear volume loss (in mm3) against the metal abrader after 60,000 cycles were 0.10 ± 0.01 for the 3D printed resin, 0.21 ± 0.02 for the milled resin, and 0.44 ± 0.01 for the conventional resin. Statistically significant differences among volume losses were found in the order of 3D printed, milled, and conventional interim materials (P<.001). After 60,000 cycles of simulated chewing, the mean surface roughness (Ra; ㎛) values for 3D printed, milled, and conventional materials were 0.59 ± 0.06, 1.27 ± 0.49, and 1.64 ± 0.44, respectively. A significant difference was found in the Ra value between 3D printed and conventional materials (P=.01). CONCLUSION. The interim restorative materials for additive and subtractive manufacturing digital technologies exhibited less wear volume loss than the conventional interim resin. The 3D printed interim restorative material showed a smoother surface than the conventional interim material after simulated chewing.