• 제목/요약/키워드: Computed tomography imaging

검색결과 1,721건 처리시간 0.028초

Assessment of Right Ventricular Function in Pulmonary Hypertension with Multimodality Imaging

  • Seo, Hye Sun;Lee, Heon
    • Journal of Cardiovascular Imaging
    • /
    • 제26권4호
    • /
    • pp.189-200
    • /
    • 2018
  • Pulmonary hypertension (PH) is defined as resting mean pulmonary artery pressure ${\geq}25mmHg$ and is caused by multiple etiologies including heart, lung or other systemic diseases. Evaluation of right ventricular (RV) function in PH is very important to plan treatment and determine prognosis. However, quantification of volume and function of the RV remains difficult due to complicated RV geometry. A number of imaging tools has been utilized to diagnose PH and assess RV function. Each imaging technique including conventional echocardiography, three-dimensional echocardiography, strain echocardiography, computed tomography and cardiac magnetic resonance imaging has-advantages and limitations and can provide unique information. In this article, we provide a comprehensive review of the utility, advantages and shortcomings of the multimodality imaging used to evaluate patients with PH.

도파민 운반체 영상의 임상이용을 위한 실제적 접근 (Practical Approach for the Clinical Use of Dopamine Transporter Imaging)

  • 김재승
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권6호
    • /
    • pp.425-434
    • /
    • 2008
  • Dopamine transporter imaging is useful in the diagnosis of Parkinson's disease and the most successful technique in the clinical use of neuroreceptor imaging. Recently, several radiopharmaceuticals including I-123 FP-CIT, Tc-99m TRODAT, and F-18 FP-CIT for dopamine transporter imaging have been approved for the routine clinical use in several European countries, Taiwan and Korea, respectively. This review summarized the practical issue for the routine clinical examination of dopamine transporter imaging.

상악에서 발생한 석회화를 동반한 치성각화낭 (Odontogenic keratocyst with dystrophic calcifications in the maxilla)

  • 김태영;허경회
    • Imaging Science in Dentistry
    • /
    • 제40권2호
    • /
    • pp.99-101
    • /
    • 2010
  • Odontogenic keratocyst (OKC) with secondary inflammation involving the maxillary sinus was presented. Radiological diagnosis of this case was made based on the various findings from the cone-beam computed tomography, computed tomography and magnetic resonance images. There were calcified materials and impacted tooth within the lumen of the lesion, which is not uncommon in OKC. Histopathologic findings confirmed this lesion as OKC with secondary inflammation.

Accuracy of maxillofacial prototypes fabricated by different 3-dimensional printing technologies using multi-slice and cone-beam computed tomography

  • Yousefi, Faezeh;Shokri, Abbas;Farhadian, Maryam;Vafaei, Fariborz;Forutan, Fereshte
    • Imaging Science in Dentistry
    • /
    • 제51권1호
    • /
    • pp.41-47
    • /
    • 2021
  • Purpose: This study aimed to compare the accuracy of 3-dimensional(3D) printed models derived from multidetector computed tomography (MDCT) and cone-beam computed tomography (CBCT) systems with different fields of view (FOVs). Materials and Methods: Five human dry mandibles were used to assess the accuracy of reconstructions of anatomical landmarks, bone defects, and intra-socket dimensions by 3D printers. The measurements were made on dry mandibles using a digital caliper (gold standard). The mandibles then underwent MDCT imaging. In addition, CBCT images were obtained using Cranex 3D and NewTom 3G scanners with 2 different FOVs. The images were transferred to two 3D printers, and the digital light processing (DLP) and fused deposition modeling (FDM) techniques were used to fabricate the 3D models, respectively. The same measurements were also made on the fabricated prototypes. The values measured on the 3D models were compared with the actual values, and the differences were analyzed using the paired t-test. Results: The landmarks measured on prototypes fabricated using the FDM and DLP techniques based on all 4 imaging systems showed differences from the gold standard. No significant differences were noted between the FDM and DLP techniques. Conclusion: The 3D printers were reliable systems for maxillofacial reconstruction. In this study, scanners with smaller voxels had the highest precision, and the DLP printer showed higher accuracy in reconstructing the maxillofacial landmarks. It seemed that 3D reconstructions of the anterior region were overestimated, while the reconstructions of intra-socket dimensions and implant holes were slightly underestimated.

형광 X선 CT에서 촬상 시간의 단축화 알고리즘 (Algorithm to Shorten Imaging Time in Fluorescent X-ray Computed Tomogrpahy)

  • 정남채
    • 융합신호처리학회논문지
    • /
    • 제2권4호
    • /
    • pp.46-52
    • /
    • 2001
  • 방사광을 이용한 형강 X선 CT 이미징의 고속화를 위한 촬상 시스템과 처리 알고리즘을 검토하였다. 본 논문에서 사용된 촬상시스템은 고계수율 영역에서 안정된 동작을 한 전자 시스템으로 불감시간이 약 6%로 감소되고 계측시간의 경우도 1 점 당 3초로 단축되었다. 또한 재구성 알고리즘의 효율화를 증명하였고, 메모리와 계산량을 약 1/100로 감소시켰다. 물리적 phantom으로 그 정량성을 확인하였고, 시험관내의 갑상선의 화상으로부터 요드 분포를 추정하였다. 이러한 결과는 생체내에서 형광 X선 CT 계측의 실현 가능성을 보여준 것이다.

  • PDF

Improvement of signal and noise performance using single image super-resolution based on deep learning in single photon-emission computed tomography imaging system

  • Kim, Kyuseok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제53권7호
    • /
    • pp.2341-2347
    • /
    • 2021
  • Because single-photon emission computed tomography (SPECT) is one of the widely used nuclear medicine imaging systems, it is extremely important to acquire high-quality images for diagnosis. In this study, we designed a super-resolution (SR) technique using dense block-based deep convolutional neural network (CNN) and evaluated the algorithm on real SPECT phantom images. To acquire the phantom images, a real SPECT system using a99mTc source and two physical phantoms was used. To confirm the image quality, the noise properties and visual quality metric evaluation parameters were calculated. The results demonstrate that our proposed method delivers a more valid SR improvement by using dense block-based deep CNNs as compared to conventional reconstruction techniques. In particular, when the proposed method was used, the quantitative performance was improved from 1.2 to 5.0 times compared to the result of using the conventional iterative reconstruction. Here, we confirmed the effects on the image quality of the resulting SR image, and our proposed technique was shown to be effective for nuclear medicine imaging.

Craniosynostosis : Updates in Radiologic Diagnosis

  • Kim, Hyun Jeong;Roh, Hong Gee;Lee, Il Woo
    • Journal of Korean Neurosurgical Society
    • /
    • 제59권3호
    • /
    • pp.219-226
    • /
    • 2016
  • The purpose of this article is to review imaging findings and to discuss the optimal imaging methods for craniosynostosis. The discussion of imaging findings are focused on ultrasonography, plain radiography, magnetic resonance imaging and computed tomography with 3-dimensional reconstruction. We suggest a strategy for imaging work-up for the diagnosis, treatment planning and follow-up to minimize or avoid ionized radiation exposure to children by reviewing the current literature.

Imaging findings in a case of Gorlin-Goltz syndrome: a survey using advanced modalities

  • Bronoosh, Pegah;Shakibafar, Ali Reza;Houshyar, Maneli;Nafarzade, Shima
    • Imaging Science in Dentistry
    • /
    • 제41권4호
    • /
    • pp.171-175
    • /
    • 2011
  • Gorlin-Goltz syndrome is an infrequent multi-systemic disease which is characterized by multiple keratocysts in the jaws, calcification of falx cerebri, and basal cell carcinomas. We report a case of Gorlin-Goltz syndrome in a 23-year-old man with emphasis on image findings of keratocyctic odontogenic tumors (KCOTs) on panoramic radiograph, computed tomography, magnetic resonance (MR) imaging, and Ultrasonography (US). In this case, pericoronal lesions were mostly orthokeratinized odontogenic cyst (OOC) concerning the MR and US study, which tended to recur less. The aim of this report was to clarify the characteristic imaging features of the syndrome-related keratocysts that can be used to differentiate KCOT from OOC. Also, our findings suggested that the recurrence rate of KCOTs might be predicted based on their association to teeth.

Inter-observer reliability in cone-beam computed tomography assessment of the retromolar canal: A practical plan to improve diagnostic imaging

  • Igarashi, Chinami;Theramballi, Yeshoda Ganesh;Kobayashi, Kaoru
    • Imaging Science in Dentistry
    • /
    • 제52권2호
    • /
    • pp.181-186
    • /
    • 2022
  • Purpose: This study aimed to investigate inter-observer reliability among observers with different levels of proficiency and the diagnostic imaging reliability of cone-beam computed tomography (CBCT) images of the retromolar canal. Materials and Methods: CBCT images of 307 patients were assessed for the presence of retromolar canals(RMCs) by 3 observers independently. Diagnoses were made twice by each observer at intervals of more than 3 weeks. Interobserver reliability was assessed using the kappa coefficient. One observer had no experience in diagnosis using CBCT images. Therefore, a specialist in diagnostic imaging explained the CBCT images for interpretation and practiced diagnostic imaging together with this observer, while the other observer interpreted the images independently. Thereafter, the observers re-evaluated the images. Results: The interobserver kappa coefficients (including bilateral RMCs) calculated at the first reading were low, ranging from 0.21 to 0.61. Their values ranged from 0.95 (right side) to 1.00 (left side) after one-on-one practice with a diagnostic imaging specialist, while the values ranged from 0.65 (right side) to 0.66 (left side) without one-on-one practice. Conclusion: Diagnostic accuracy was improved through diagnostic imaging practice. To improve the anatomical interpretation of images, it is important to practice diagnostic imaging with a specialist in diagnostic imaging. One-on-one instruction about diagnostic imaging was an effective method of training.