• Title/Summary/Keyword: Computed tomography imaging

Search Result 1,797, Processing Time 0.029 seconds

Global Cerebral Ischemia in a Beagle Dog (비글견에서 발생한 전반적 대뇌허혈)

  • Choi, Ho-Jung;Choi, Soo-Young;An, Ji-Young;O, I-Se;Jeong, Seong-Mok;Cho, Sung-Whan;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.26 no.1
    • /
    • pp.104-108
    • /
    • 2009
  • Global cerebral ischemia occurs commonly in patients who have a variety of clinical conditions including cardiac arrest and shock. Cerebral ischemia results in a rapid depletion of energy stores that triggers resulting in excitotoxic death. Imaging studies of the brain with computed tomography(CT) or magnetic resonance imaging(MRI) are necessary to confirm the clinical neurolocalization, identify any associated mass effect, and rule out other causes of focal brain disorders. Cardiopulmonary arrest was occurred by propofol anesthesia in a 1 year old, intact female Beagle dog. After successful cardiopulmonary resuscitation was performed within 5 minutes, clinical signs such as vocalization, paddling, opisthotonus and seizure were represented. At the 12th day, CT and MRI examinations of the brain were performed to evaluate the brain. After euthanasia, histopathologic examination was performed. On transverse image of CT, lesions appeared as a hypodense in the right dorsal surface of the frontal lobe and level of optic canal, and dorsomedial surface of occipital lobe of cerebrum. No contrast enhancement was represented following intravenous contrast administration. On MR images of brain, the lesions were seen as a hyperintense on T2-weighted(T2W) images and a isointense or mild hypointense on T1-weighted(T1W) images. Hyperintense lesions both T2W and T1W images were observed at the surrounding cerebral sulcus. There was no significant signal changes on contrast T1WI. Histopathologic examination after euthanasia revealed that the lesion was necrosis of the cerebral cortex caused by cerebral ischemia.

The preliminary study for three-dimensional alveolar bone morphologic characteristics for alveolar bone restoration

  • Cho, Hyun-Jae;Jeon, Jae-Yun;Ahn, Sung-Jin;Lee, Sung-Won;Chung, Joo-Ryun;Park, Chang-Joo;Hwang, Kyung-Gyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.33.1-33.7
    • /
    • 2019
  • Background: The concept of the ideal morphology for the alveolar bone form is an important element to reconstruct or restore the in maximizing esthetic profile and functional alveolar bone restoration. The purpose of this preliminary study is to evaluate the normal alveolar bone structure to provide the standard reference and guide template for use in diagnosing for implant placement, determining the correct amount of bone augmentation in actual clinical practice and producing prostheses based on three-dimensional imaging assessment of alveolar bone. Methods: This study was included 11 men and 11 women (average age, 22.6 and 24.5 years, respectively) selected from among 127 patients. The horizontal widths of alveolar bone of maxilla and mandible were measured at the crestal, mid-root, and root apex level on MDCT (multi-detector computed tomography) images reconstructed by medical imaging software. In addition, tooth dimensions of the central incisors, canines, second premolars, and first molars of maxilla and mandible, including the horizontal width of the interdental alveolar bone crest, were also measured and statistically analyzed. Results: The horizontal alveolar bone width of the palatal side of maxilla showed a distinct increment from the alveolar bone crest to the apical region in both anterior and posterior areas. The average widths of the maxillary alveolar ridge were as follows: central incisor, 7.43 mm; canine, 8.91 mm; second premolar, 9.57 mm; and first molar, 12.38 mm. The average widths of the mandibular alveolar ridge were as follows: central incisor, 6.21 mm; canine, 8.55 mm; second premolar, 8.45 mm; and first molar, 10.02 mm. In the buccal side, the alveolar bone width was not increased from the crest to the apical region. The horizontal alveolar bone width of an apical and mandibular border region was thinner than at the mid-root level. Conclusions: The results of the preliminary study are useful as a clinical guideline when determining dental implant diameter and position. And also, these measurements can also be useful during the production of prefabricated membranes and customized alveolar bone scaffolds.

Clinical Study of Tumor Angiogenesis and Perfusion Imaging Using Multi-slice Spiral Computed Tomography for Breast Cancer

  • Xu, Na;Lei, Zhen;Li, Xiao-Long;Zhang, Jun;Li, Chen;Feng, Guo-Quan;Li, Di-Nuo;Liu, Jing-Yi;Wei, Qiang;Bian, Ting-Ting;Zou, Tian-Yu
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.429-433
    • /
    • 2013
  • Objectives: To explore the correlation between multi-slice spiral CT (MSCT) perfusion parameters and the expression of vascular endothelial growth factor (VEGF) as well as matrix metalloproteinase-2 (MMP-2) in breast cancer. Methods: Forty five breast cancer patients and 16 patients with benign breast tumor, both confirmed by pathology examination, were enrolled. All underwent MSCT perfusion imaging to obtain perfusion maps and data for parameters including blood flow (BF), blood volume (BV) and permeability surface (PS). Cancer patients did not receive treatment prior to surgery. The expression of VEGF and MMP-2 were examined with both immunohistochemistry and Western blotting. Results: The levels of VEGF and MMP-2 by immunohistochemistry were significantly higher in the breast cancer group (P < 0.01) than the benign tumor group. Relative OD values from Western blotting were also higher in cancer cases (P < 0.05). Similarly, the mean MSCT perfusion parameters (BF, BV, PS) were significantly higher in the breast cancer group (P < 0.01), BF and BV positively correlating with VEGF expression (r = 0.878 and 0.809 respectively, P < 0.01); PS and VEGF and MMP-2 expression were also positively correlated (r= 0.860, 0.786 respectively, P < 0.01). Conclusion: There is a correlation between breast cancer MSCT perfusion parameters and VEGF andMMP-2 expression, which might be useful for detection of breast lesions, qualitative diagnosis of breast cancer, and evaluation of breast cancer treatment.

Isolated Right Pulmonary Artery Hypoplasia with Retrograde Blood Flow in a 68-Year Old Man

  • Chang, You-Jin;Ra, Seung-Won;Chae, Eun-Jin;Seo, Joon-Beom;Kim, Won-Young;Na, Shin;Kim, Joo-Hee;Park, Tai-Sun;Park, Soo-Kyung;Park, Seong-Joon;Lee, Tae-Hoon;Ahn, Young-Chel;Lee, Sang-Do
    • Tuberculosis and Respiratory Diseases
    • /
    • v.71 no.2
    • /
    • pp.126-133
    • /
    • 2011
  • Unilateral pulmonary artery hypoplasia (UPAH) is a rare disease in adults and is frequently accompanied by a congenital cardiac anomaly at a young age. The diagnosis is usually based on computed tomography (CT), angiography, and magnetic resonance imaging (MRI). However, no reports are available on retrograde flow in patients with UPAH. We describe a 68-year-old man with isolated UPAH and retrograde blood flow. He was admitted for dyspnea on exertion for the past 23 years. His diagnosis was delayed, as his symptoms and signs mimicked his underlying pulmonary diseases, such as emphysema and previous tuberculous pleurisy sequelae. A discrepancy was detected between the results of a ventilation-perfusion scan and the CT image. This was resolved by MRI, which showed retrograde blood flow from the right to the left pulmonary artery. Using MRI, we diagnosed this patient with isolated pulmonary artery hypoplasia and retrograde flow.

Diagnostic Imaging of Lipoma in the Retroperitoneum and Pelvic Cavity in a Dog (개의 후복강과 골반강에 발생한 지방종의 진단영상 증례)

  • Lee, Nam-Soon;Kim, Jun-Young;Na, Eung-Sic;Kim, Mi-Eun;Lee, Hye-Yeon;Choi, Mi-Hyun;Kim, Wan-Hee;Kim, Dae-Yong;Choi, Min-Cheol;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.27 no.1
    • /
    • pp.88-92
    • /
    • 2010
  • An 11-year-old, spayed female, weighing 10 kg miniature Schnauzer was admitted for abdominal distension, anorexia, pollakiuria, and constipation. A large, homogeneous fat opacity mass was identified in the retroperitoneum and pelvic cavity on the abdominal survey radiography. The mass displaced the descending colon peripherally and ventrally, and the urinary bladder ventrally. On the abdominal ultrasonographic examination, the mass was uniformly hyperechoic with a coarse internal echo texture and had outer hyperechoic capsule, and it showed homogeneously same attenuation (-180 ~ -110 HU) as adjacent fat on the computed tomography. There was no evidence of invasion into the surrounding structures or organs. Cytological findings from fine needle aspirates were numerous sheets and clusters of adipocytes. The dog showed complete resolution of clinical signs after surgical resection of the mass. The mass was confirmed as simple lipoma through histopathological examination.

Influence of Radiologically Evident Residual Intimal Tear on Expansion of Descending Aorta Following Surgery for Acute Type I Aortic Dissection

  • Kim, Yun Seok;Kim, Jeong Heon;Kim, Joon Bum;Yang, Dong Hyun;Kang, Joon-Won;Hwang, Su Kyung;Choo, Suk Jung;Chung, Cheol Hyun
    • Journal of Chest Surgery
    • /
    • v.47 no.1
    • /
    • pp.6-12
    • /
    • 2014
  • Background: Although a residual intimal tear may contribute to the dilatation of the descending aorta following surgical repair of acute type I aortic dissection (AD), its causal relationship has not been elucidated by clinical data due to the limited resolution of imaging modalities. Methods: This study enrolled 41 patients (age, $55.2{\pm}11.9$ years) who were evaluated with dual-source computed tomography (CT) imaging of the whole aorta in the setting of the surgical repair of acute type I AD. Logistic regression models were used to determine the predictors of a composite of the aortic aneurysm formation (diameter >55 mm) and rapid aortic expansion (>5 mm/yr). Results: On initial CT, a distal re-entry tear was identified in 9 patients. Two patients failed to achieve proximal tear exclusion by the surgery. Serial follow-up CT evaluations (median, 24.6 months; range, 6.0 to 67.2 months) revealed that 14 patients showed rapid expansion of the descending aorta or aortic aneurysm formation. A multivariate analysis revealed that the residual intimal tear (odds ratio [OR], 4.31; 95% confidence interval [CI], 1.02 to 19.31) and the patent false lumen in the early postoperative setting (OR, 4.64; 95% CI, 0.99 to 43.61) were predictive of the composite endpoint. Conclusion: The presence of a residual intimal tear following surgery for acute type I AD adversely influenced the expansion of the descending aorta.

A study of image evaluation and exposure dose with the application of Tube Voltage and ASIR of Low dose CT Using Chest Phantom (흉부 Phantom을 이용한 Low Dose CT의 관전압과 ASIR(Adaptive Statistical Iterative Reconstruction)적용에 따른 영상평가 및 피폭선량에 관한 연구)

  • Hwang, Hyeseong;Kim, Nuri;Jeong, Yoonji;Goo, Eunhoe;Kim, Kijeong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.9-14
    • /
    • 2014
  • Purpose: The purpose of this study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying Filtered Back Projection(FBP), the existing test method, and Adaptive Statistical Iterative Reconstruction(ASIR) with different values of tube voltage during the Low Dose Computed Tomography(LDCT). Materials and Methods: With the image reconstruction method as basis, Chest Phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of Tube Voltage (100kVp, 120kVp). For image evaluation, Back ground noise, Signal to Noise ratio(SNR) and Contrast to Noise ratio(CNR) were measured, and, for dose evaluation, CTDIvol and DLP were measured respectively. The statistical analysis was tested with SPSS(ver. 22.0), followed by ANOVA Test conducted after normality test and homogeneity test. (p<0.05). Results: In terms of image evaluation, there was no outstanding difference in Ascending Aorta(AA) SNR and Infraspinatus Muscle(IM) SNR with the different values of ASIR application(p<0.05), but a significant difference with the different amount of tube voltage(p>0.05). Also, there wasn't noticeable change in CNR with ASIR and different amount of Tube Voltage (p<0.05). However, in terms of dose evaluation, CTDIvol and DLP showed contrasting results(p<0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120kVp were 2.6mGy with No-ASIR and 2.17mGy with 20%-ASIR respectively, decreased by 0.43mGy, and the values with 100kVp were 1.61mGy with No-ASIR and 1.34mGy with 20%-ASIR, decreased by 0.27mGy. In terms of DLP, the measured values with 120kVp were $103.21mGy{\cdot}cm$ with No-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$(about 16.7%), and the values with 100kVp were $63.84mGy{\cdot}cm$ with No-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$(about 16.7%). Conclusion: At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise. For the future, through the result of the experiment, it is considered that the method above would be recommended for follow-up patients or those who get health checkup as long as there is no interference on the process of diagnosis due to the characteristics of Low Dose examination.

  • PDF

Three-dimensional image analysis of the skull using variable CT scanning protocols-effect of slice thickness on measurement in the three-dimensional CT images (두개골의 3차원 영상 분석을 위한 전산화단층촬영 방법의 비교-상층 두께가 3차원 영상의 계측에 미치는 영향)

  • Jeong Ho-Gul;Kim Kee-Deog;Park Hyok;Kim Dong-Ook;Jeong Haijo;Kim Hee-Joung;Yoo Sun Koo;Kim Yong Oock;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.151-157
    • /
    • 2004
  • Purpose : To evaluate the quantitative accuracy of three-dimensional (3D) images by means of comparing distance measurements on the 3D images with direct measurements of dry human skull according to slice thickness and scanning modes. Materials and Mathods : An observer directly measured the distance of 21 line items between 12 orthodontic landmarks on the skull surface using a digital vernier caliper and each was repeated five times. The dry human skull was scanned with a Helical CT with various slice thickness (3, 5, 7 mm) and acquisition modes (Conventional and Helical). The same observer measured corresponding distance of the same items on reconstructed 3D images with the internal program of V-works 4.0/sup TM/(Cybermed Inc., Seoul, Korea). The quantitative accuracy of distance measurements were statistically evaluated with Wilcoxons' two-sample test. Results: 11 line items in Conventional 3 mm, 8 in Helical 3mm, 11 in Conventional 5mm, 10 in Helical 5mm, 5 in Conventional 7mm and 9 in Helical 7mm showed no statistically significant difference. Average difference between direct measurements and measurements on 3D CT images was within 2mm in 19 line items of Conventional 3mm, 20 of Helical 3mm, 15 of Conventional 5mm, 18 of Helical 5mm, II of Conventional 7mm and 16 of Helical 7mm. Conclusion: Considering image quality and patient's exposure time, scanning protocol of Helical 5mm is recommended for 3D image analysis of the skull in CT.

  • PDF

Diagnostic imaging analysis of the impacted mesiodens (매복 정중치의 진단영상분석)

  • Noh, Jeong-Jun;Choi, Bo-Ram;Jeong, Hwan-Seok;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Lee, Sam-Sun;Choi, Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.40 no.2
    • /
    • pp.69-74
    • /
    • 2010
  • Purpose : The research was performed to predict the three dimensional relationship between the impacted mesiodens and the maxillary central incisors and the proximity with the anatomic structures by comparing their panoramic images with the CT images. Materials and Methods : Among the patients visiting Seoul National University Dental Hospital from April 2003 to July 2007, those with mesiodens were selected (154 mesiodens of 120 patients). The numbers, shapes, orientation and positional relationship of mesiodens with maxillary central incisors were investigated in the panoramic images. The proximity with the anatomical structures and complications were investigated in the CT images as well. Results : The sex ratio (M : F) was 2.28 : 1 and the mean number of mesiodens per one patient was 1.28. Conical shape was 84.4% and inverted orientation was 51.9%. There were more cases of anatomical structures encroachment, especially on the nasal floor and nasopalatine duct, when the mesiodens was not superimposed with the central incisor. There were, however, many cases of the nasopalatine duct encroachment when the mesiodens was superimpoised with the apical 1/3 of central incisor (52.6%). Delayed eruption (55.6%), crown rotation (66.7%) and crown resorption (100%) were observed when the mesiodens was superimposed with the crown of the central incisor. Conclusion : It is possible to predict three dimensional relationship between the impacted mesiodens and the maxillary central incisors in the panoramic images, but more details should be confirmed by the CT images when necessary.

Preparation of Gold Coated Liposomes for CT Contrast Medium (CT 조영을 위한 금 코팅 리포솜의 제조)

  • Wee, Tae In;Jeon, Ye Won;Cho, Young Jae;Cho, Sung Keun;Ha, Jeung;Lee, Jeong Won;Cho, Sun Hang;Han, Hee Dong;Shin, Byung Cheol
    • Journal of the Korean Chemical Society
    • /
    • v.57 no.5
    • /
    • pp.634-639
    • /
    • 2013
  • The use of medical imaging has been increased for diagnosis of cancer or vessel disease. Among the medical imaging, computed tomography (CT) is one of the popular methods, however, which should need administration of contrast medium. Therefore, we developed gold coated liposomes (GCL) as a contrast medium. To coat gold on the liposomal surface, positive charged liposomes was prepared and then negative $Au^-$ can coat on the liposomal surface by electronic interaction. The size of GCL was $154.8{\pm}9.2$ nm and surface charge was $27{\pm}3.2$ mV, respectively. The morphology of GCL was confirmed by electron microscopy (SEM) and transmission electron microscopy (TEM). The coating efficiency of gold was 18%. Chemical procedure for gold coating on liposomal surface was not toxic for cell cytotoxicity by MTT assay. Finally, we demonstrated attractive CT image for GCL. Taken together, the GCL would be useful for various vessel related disease as a contrast medium.