• Title/Summary/Keyword: Computed tomography dose index

Search Result 63, Processing Time 0.017 seconds

Difference in the Set-up Margin between 2D Conventional and 3D CT Based Planning in Patients with Early Breast Cancer (조기유방암환자의 이차원치료계획과 삼차원치료계획의 방사선조사범위의 차이)

  • Jo, Sun-Mi;Chun, Mi-Son;Kim, Mi-Hwa;Oh, Young-Taek;Kang, Seung-Hee;Noh, O-Kyu
    • Radiation Oncology Journal
    • /
    • v.28 no.3
    • /
    • pp.177-183
    • /
    • 2010
  • Purpose: Simulation using computed tomography (CT) is now widely available for radiation treatment planning for breast cancer. It is an important tool to help define the tumor target and normal tissue based on anatomical features of an individual patient. In Korea, most patients have small sized breasts and the purpose of this study was to review the margin of treatment field between conventional two-dimensional (2D) planning and CT based three-dimensional (3D) planning in patients with small breasts. Materials and Methods: Twenty-five consecutive patients with early breast cancer undergoing breast conservation therapy were selected. All patients underwent 3D CT based planning with a conventional breast tangential field design. In 2D planning, the treatment field margins were determined by palpation of the breast parenchyma (In general, the superior: base of the clavicle, medial: midline, lateral: mid - axillary line, and inferior margin: 2 m below the inframammary fold). In 3D planning, the clinical target volume (CTV) ought to comprise all glandular breast tissue, and the PTV was obtained by adding a 3D margin of 1 cm around the CTV except in the skin direction. The difference in the treatment field margin and equivalent field size between 2D and 3D planning were evaluated. The association between radiation field margins and factors such as body mass index, menopause status, and bra size was determined. Lung volume and heart volume were examined on the basis of the prescribed breast radiation dose and 3D dose distribution. Results: The margins of the treatment field were smaller in the 3D planning except for two patients. The superior margin was especially variable (average, 2.5 cm; range, -2.5 to 4.5 cm; SD, 1.85). The margin of these targets did not vary equally across BMI class, menopause status, or bra size. The average irradiated lung volume was significantly lower for 3D planning. The average irradiated heart volume did not decrease significantly. Conclusion: The use of 3D CT based planning reduced the radiation field in early breast cancer patients with small breasts in relation to conventional planning. Though a coherent definition of the breast is needed, CT-based planning generated the better plan in terms of reducing the irradiation volume of normal tissue. Moreover it was possible that 3D CT based planning showed better CTV coverage including postoperative change.

Dose verification for Gated Volumetric Modulated Arc Therapy according to Respiratory period (호흡연동 용적변조 회전방사선치료에서 호흡주기에 따른 선량전달 정확성 검증)

  • Jeon, Soo Dong;Bae, Sun Myung;Yoon, In Ha;Kang, Tae Young;Baek, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.137-147
    • /
    • 2014
  • Purpose : The purpose of this study is to verify the accuracy of dose delivery according to the patient's breathing cycle in Gated Volumetric Modulated Arc Therapy Materials and Methods : TrueBeam STxTM(Varian Medical System, Palo Alto, CA) was used in this experiment. The Computed tomography(CT) images that were acquired with RANDO Phantom(Alderson Research Laboratories Inc. Stamford. CT, USA), using Computerized treatment planning system(Eclipse 10.0, Varian, USA), were used to create VMAT plans using 10MV FFF with 1500 cGy/fx (case 1, 2, 3) and 220 cGy/fx(case 4, 5, 6) of doserate of 1200 MU/min. The regular respiratory period of 1.5, 2.5, 3.5 and 4.5 sec and the patients respiratory period of 2.2 and 3.5 sec were reproduced with the $QUASAR^{TM}$ Respiratory Motion Phantom(Modus Medical Devices Inc), and it was set up to deliver radiation at the phase mode between the ranges of 30 to 70%. The results were measured at respective respiratory conditions by a 2-Dimensional ion chamber array detector(I'mRT Matrixx, IBA Dosimetry, Germany) and a MultiCube Phantom(IBA Dosimetry, Germany), and the Gamma pass rate(3 mm, 3%) were compared by the IMRT analysis program(OmniPro I'mRT system software Version 1.7b, IBA Dosimetry, Germany) Results : The gamma pass rates of Case 1, 2, 3, 4, 5 and 6 were the results of 100.0, 97.6, 98.1, 96.3, 93.0, 94.8% at a regular respiratory period of 1.5 sec and 98.8, 99.5, 97.5, 99.5, 98.3, 99.6% at 2.5 sec, 99.6, 96.6, 97.5, 99.2, 97.8, 99.1% at 3.5 sec and 99.4, 96.3, 97.2, 99.0, 98.0, 99.3% at 4.5 sec, respectively. When a patient's respiration was reproduced, 97.7, 95.4, 96.2, 98.9, 96.2, 98.4% at average respiratory period of 2.2 sec, and 97.3, 97.5, 96.8, 100.0, 99.3, 99.8% at 3.5 sec, respectively. Conclusion : The experiment showed clinically reliable results of a Gamma pass rate of 95% or more when 2.5 sec or more of a regular breathing period and the patient's breathing were reproduced. While it showed the results of 93.0% and 94.8% at a regular breathing period of 1.5 sec of Case 5 and 6, it could be confirmed that the accurate dose delivery could be possible on the most respiratory conditions because based on the results of 100 patients's respiratory period analysis as no one sustained a respiration of 1.5 sec. But, pretreatment dose verification should be precede because we can't exclude the possibility of error occurrence due to extremely short respiratory period, also a training at the simulation and careful monitoring are necessary for a patient to maintain stable breathing. Consequently, more reliable and accurate treatments can be administered.

Short-Term Efficacy of Steroid and Immunosuppressive Drugs in Patients with Idiopathic Pulmonary Fibrosis and Pre-treatment Factors Associated with Favorable Response (특발성폐섬유화증에서 스테로이드와 면역억제제의 단기 치료효과 및 치료반응 예측인자)

  • Kang, Kyeong-Woo;Park, Sang-Joon;Koh, Young-Min;Lee, Sang-Pyo;Suh, Gee-Young;Chung, Man-Pyo;Han, Jung-Ho;Kim, Ho-Joong;Kwon, O-Jung;Lee, Kyung-Soo;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.5
    • /
    • pp.685-696
    • /
    • 1999
  • Background : Idiopathic pulmonary fibrosis (IPF) is a diffuse inflammatory and fibrosing process that occurs within the interstitium and alveolus of the lung with invariably poor prognosis. The major problem in management of IPF results from the variable rate of disease progression and the difficulties in predicting the response to therapy. The purpose of this retrospective study was to evaluate the short-term efficacy of steroid and immunosuppressive therapy for IPF and to identify the pre-treatment determinants of favorable response. Method : Twenty patients of IPF were included. Diagnosis of IPF was proven by thoracoscopic lung biopsy and they were presumed to have active progressive disease. The baseline evaluation in these patients included clinical history, pulmonary function test, bronchoalveolar lavage (BAL), and chest high resolution computed tomography (HRCT). Fourteen patients received oral prednisolone treatment with initial dose of 1mg/kg/day for 8 to 12 weeks and then tapering to low-dose prednisolone (0.25mg/kg/day). Six patients who previously had experienced significant side effects to steroid received 2mg/kg/day of oral cyclophosphamide with or without low-dose prednisolone. Follow-up evaluation was performed after 6 months of therapy. If patients met more than one of followings, they were considered to be responders : (1) improvement of more than one grade in dyspnea index, (2) improvement in FVC or TLC more than 10% or improvement in DLco more than 20% (3) decreased extent of disease in chest HRCT findings. Result : One patient died of extrapulmonary cause after 3 month of therapy, and another patient gave up any further medical therapy due to side effect of steroid. Eventually medical records of 18 patients were analyzed. Nine of 18 patients were classified into responders and the other nine patients into nonresponders. The histopathologic diagnosis of the responders were all nonspecific interstitial pneumonia (NSIP) and that of nonresponders were all usual interstitial pneumonia (UIP) (p<0.001). The other significant differences between the two groups were female predominance (p<0.01), smoking history (p<0.001), severe grade of dyspnea (p<0.05), lymphocytosis in BAL fluid ($23.8{\pm}16.3%$ vs $7.8{\pm}3.6%$, p<0.05), and less honeycombing in chest HRCT findings (0% vs $9.2{\pm}2.3%$, p<0.001). Conclusion : Our results suggest that patients with histopathologic diagnosis of NSIP or lymphocytosis in BAL fluid are more likely to respond to steroid or immunosuppressive therapy. Clinical results in large numbers of IPF patients will be required to identify the independent variables.

  • PDF