• 제목/요약/키워드: Computed Tomography Fluoroscopy

Search Result 41, Processing Time 0.024 seconds

Diaphragmatic Hernia of the Right Hepatic Lobe Mistaken for Diaphragmatic Paralysis in Adult (성인에서 횡격막마비로 오인한 우엽간 횡격막탈장 1예)

  • Park, Jung-Hyun;Hwang, Ki-Eun;Kim, So-Young;Kim, Hak-Ryul;Yang, Sei-Hoon;Kim, Hwi-Jung;Jeong, Eun-Taik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.68 no.5
    • /
    • pp.298-300
    • /
    • 2010
  • Diaphragmatic paralysis can be demonstrated through diaphragmatic elevation on chest X-ray after thoracic lung surgery or the placement of chest tubing. Additional causes of diaphragmatic paralysis are iatrogenic, mass, atelectasis, etc. For the diagnosis of diaphragmatic paralysis, it required some studies (fluoroscopy, computed tomography [CT], magnetic resonance imaging). Diaphragmatic hernia of the liver is a rare clinical entity, usually found after trauma in adults. Congenital diaphragmatic hernia in neonates requires surgery. Non-traumatic diaphragmatic hernia of the liver in an adult is a rare right-sided diaphragmatic hernia. On developing any symptoms, surgery must be performed. When diaphragmatic hernia is incidentally found in adults without trauma, it is placed under observation for a time period. We diagnosed the diaphragmatic herniation of a right hepatic lobe by 16-slice CT scan without surgery.

A Case of Recurrent Liver Abscess Due to Choledochoduodenal Fistula (재발하는 간농양에서 총담관-십이지장 누공의 내시경적 치료 1예)

  • Hur, Jun Ho;Choi, Sun Taek;Sohn, Min Su;Lee, Ji Eun;Chung, In Hee;Ki, Sung Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.30 no.1
    • /
    • pp.39-42
    • /
    • 2013
  • Cholelithiasis, duodenal ulcer, duodenal perforation and tumor invasion may lead to choledochoduodenal fistula (CDF). CDF often has no specific symptoms and may be incidentally detected in an upper gastrointestinal radiographic study or endoscopy; but in some cases, it may be accompanied by recurrent cholangitis and liver abscess. In this paper, a case of recurrent liver abscess caused by CDF is reported. A 62-year-old female was admitted to the authors' hospital because of right upper quadrant pain and fever. The abdominal computed tomography showed a liver abscess in the right lobe. A duodenal fistulous orifice was detected with endoscopy, and a contrast was injected through the duodenal orifice using a catheter under fluoroscopy. The injection of the contrast revealed a fistulous track between the duodenal bulb and the common hepatic duct. In fistulas complicated by recurrent liver abscess, surgery or medical management may be needed. The CDF in this case study was treated via endoscopic clipping.

The Inaccuracy of Surface Landmarks for the Anterior Approach to the Cervical Spine in Southern Chinese Patients

  • Ko, Tin Sui;Tse, Michael Siu Hei;Wong, Kam Kwong;Wong, Wing Cheung
    • Asian Spine Journal
    • /
    • v.12 no.6
    • /
    • pp.1123-1126
    • /
    • 2018
  • Study Design: Observational study. Purpose: To assess the correlational accuracy between the traditional anatomic landmarks of the neck and their corresponding vertebral levels in Southern Chinese patients. Overview of Literature: Recent studies have demonstrated discrepancies between traditional anatomic landmarks of the neck and their corresponding cervical vertebra. Methods: The center of the body of the hyoid bone, the upper limit of the lamina of the thyroid cartilage, and the lower limit of the cricoid cartilage were selected as representative surface landmarks for this investigation. The corresponding vertebral levels in 78 patients were assessed using computed tomography. Results: In both male and female patients, almost none of the anatomical landmarks demonstrated greater than 50% correlation with any vertebral level. The most commonly corresponding vertebra of the hyoid bone, the lamina of the thyroid cartilage, and the cricoid cartilage were the C4 (47.5%), C5 (35.9%), and C7 (42.3%), respectively, which were all different from the classic descriptions in textbooks. The vertebral levels corresponding with the thyroid and cricoid cartilage were significantly different between genders. Conclusions: The surface landmarks of the neck were not accurate enough to be used as the sole determinant of vertebral levels or incision sites. Intra-operative fluoroscopy is necessary to accurately locate each of the cervical vertebral levels.

Digital X-Ray Technology and Applications (디지털 엑스선 기술과 응용)

  • Jeong, J.W.;Kang, J.T.;Kim, J.W.;Park, S.;Lee, M.L.;Song, Y.H.
    • Electronics and Telecommunications Trends
    • /
    • v.34 no.5
    • /
    • pp.1-13
    • /
    • 2019
  • In modern times, X-ray imaging has become a necessary tool for early diagnosis, quality control, nondestructive testing, and security screening. X-ray imaging equipment generally comprises an X-ray generator and an image sensor. Most commercially available X-ray generators employ filament-thermionic electron-based X-ray tubes, thus demonstrating typical analog behavior, such as slow response and large stray X-rays. Furthermore, digital X-ray sources, which have been studied extensively using field electron emitters manufactured from nanometer-scale materials, provide fast and accurately controlled ultra-shot X-rays. This could usher in a new era of X-ray imaging in medical diagnosis and nondestructive inspections. Specifically, digital X-ray sources, with reduced X-ray dose, can significantly improve the temporal and spatial resolution of fluoroscopy and computed tomography. Recently, digital X-ray tube technologies based on carbon nanotubes, developed by Electronics and Telecommunications Research Institute, have been transferred to several companies and commercialized for dental imaging for the first time.

Experimental Evaluation of Scattered X-Ray Spectra due to X-Ray Therapeutic and Diagnosis Equipment for Eye Lens Dosimetry of Medical Staff

  • Kowatari, Munehiko;Nagamoto, Keisuke;Nakagami, Koich;Tanimura, Yoshihiko;Moritake, Takashi;Kunugita, Naoki
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.1
    • /
    • pp.39-49
    • /
    • 2022
  • Background: For proper monitoring of the eye lens dose, an appropriate calibration factor of a dosimeter and information about the mean energies of X-rays are indispensable. The scattered X-ray energy spectra should be well characterized in medical practices where eye lenses of medical staffs might be high. Materials and Methods: Scattered X-ray energy spectra were experimentally derived for three different types of X-ray diagnostic and therapeutic equipment, i.e., the computed tomography (CT) scan, the angiography and the fluoroscopy. A commercially available CdZnTe (CZT) spectrometer with a lead collimator was employed for the measurement of scattered X-rays, which was performed in the usual manner. Results and Discussion: From the obtained energy spectra, the mean energies of the scattered X-rays lied between 40 and 60 keV. This also agreed with that obtained by the conventional half value layer method. Conclusion: The scattered X-rays to which medical workers may be exposed in the region around the eyes were characterized by means of spectrometry. The obtained mean energies of the scattered X-rays were found to match the flat region of the dosimeter response.

Computed Tomographic Simulation of Craniospinal Irradiation (전산화 단층 촬영 장치를 이용한 뇌척수 조사의 치료 계획)

  • Lee CI;Kim HN;Oh TY;Hwang DS;Park NS;Kye CS;Kim YS
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.53-59
    • /
    • 1999
  • The aim of this study is to improve the accuracy of field placement and junction between adjacent fields and block shielding through the use of a computed tomography(CT) simulator and virtual simulation. The information was acquired by assessment of Alderson Rando phantom image using CT simulator (I.Q. Xtra - Picker), determination of each field by virtual fluoroscopy of voxel IQ workstation AcQsim and colored critical structures that were obtained by contouring in virtual simulation. And also using a coronal, sagittal and axial view can determine the field and adjacent field gap correctly without calculation during the procedure. With the treatment planning by using the Helax TMS 4.0, the dose in the junction among the adjacent fields and the spinal cord and cribriform plate of the critical structure was evaluated by the dose volume histogram. The pilot image of coronal and sagittal view took about 2minutes and 26minutes to get 100 images. Image translation to the virtual simulation workstation took about 6minutes. Contouring a critical structure such as cribriform plate, spinal cord using a virtual fluoroscopy were eligible to determine a correct field and shielding. The process took about 20 minutes. As the result of the Helax planning, the dose distribution in adjacent field junction was ideal, and the dose level shows almost 100 percentage in the dose volume histogram of the spinal cord and cribriform plate CT simulation can get a correct therapy area due to enhancement of critical structures such as spinal cord and cribriform plate. In addition, using a Spiral CT scanner can be saved a lot of time to plan a simulation therefore this function can reduce difficulties to keep the patient position without any movements to the patient, physician and radiotherapy technician.

  • PDF

The variability of tumor motion and respiration pattern in Stereotactic Body RadioTherapy(SBRT) for Lung cancer patients (RPM SystemTM을 이용한 호흡 관찰의 유용성 평가)

  • Park, hyun jun;Bae, sun myeong;Baek, Geum Mun;Kang, tae young;Seo, Dong Rin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.17-25
    • /
    • 2016
  • Purpose : The purpose of this study is to evaluate the variability of tumor motion and respiration pattern in lung cancer patients undergoing Stereotactic Body RadioTherapy(SBRT) by using On-Board imager (OBI) system and Real-time Position Management (RPM) System. Materials and Methods : This study population consisted of 60 lung cancer patient treated with stereotactic body radiotherapy (48 Gy / 4 fractions). Of these, 30 were treated with gating (group 1) and 30 without gating(group2): typically the patients whose tumors showed three-dimensional respiratory motion > 10 mm were selected for gating. 4-dimensional Computed Tomography (4DCT). Cone Beam CT (CBCT) and Fluoroscopy images were used to measure the tumor motion. RPM system was used to evaluate the variability of respiration pattern on SBRT for group1. Results : The mean difference of tumor motion among 4DCT, CBCT and Fluoroscopy images in the cranio-caudal direction was 2.3 mm in group 1, 2. The maximum difference was 12.5 mm in the group 1 and 8.5 mm in group 2. The number of treatment fractions that patient's respiration pattern was within Upper-Lower threshold on SBRT in group 2 was 31 fractions. A patient who exhibited the most unstable pattern exceeded 108 times in a fraction Conclusion : Although many patients in group 1 and 2 kept the reproducibility of tumor motion within 5 mm during their treatment, some patients exhibited variability of tumor motion in the CBCT and Fluoroscopy images. It was possible to improve the accuracy of dose delivery in SBRT without gating for lung cancer patient by using RPM system.

  • PDF

Evaluation of usefulness of the Gated Cone-beam CT in Respiratory Gated SBRT (호흡동조 정위체부방사선치료에서 Gated Cone-beam CT의 유용성 평가)

  • Hong sung yun;Lee chung hwan;Park je wan;Song heung kwon;Yoon in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.61-72
    • /
    • 2022
  • Purpose: Conventional CBCT(Cone-beam Computed-tomography) caused an error in the target volume due to organ movement in the area affected by respiratory movement. The purpose of this paper is to evaluate the usefulness of accuracy and time spent using the Gated CBCT function, which reduces errors when performing RGRT(respiratory gated radiation therapy), and to examine the appropriateness of phase. Materials and methods: To evaluate the usefulness of Gated CBCT, the QUASARTM respiratory motion phantom was used in the Truebeam STxTM. Using lead marker inserts, Gated CBCT was scaned 5 times for every 20~80% phase, 30~70% phase, and 40~60% phase to measure the blurring length of the lead marker, and the distance the lead marker moves from the top phase to the end of the phase was measured 5 times. Using Cedar Solid Tumor Inserts, 4DCT was scanned for every phase, 20-80%, 30-70%, and 40-60%, and the target volume was contoured and the length was measured five times in the axial direction (S-I direction). Result: In Gated CBCT scaned using lead marker inserts, the axial moving distance of the lead marker on average was measured to be 4.46cm in the full phase, 3.11cm in the 20-80% phase, 1.94cm in the 30-70% phase, 0.90cm in the 40-60% phase. In Fluoroscopy, the axial moving distance of the lead marker on average was 4.38cm and the distance on average from the top phase to the beam off phase was 3.342cm in the 20-80% phase, 3.342cm in the 30-70% phase, and 0.84cm in the 40-60% phase. Comparing the results, the difference in the full phase was 0.08cm, the 20~80% phase was 0.23cm, the 30~70% phase was 0.10cm, and the 40~60% phase was 0.07cm. The axial lengths of ITV(Internal Target Volume) and PTV(Planning Target Volume) contoured by 4DCT taken using cedar solid tumor inserts were measured to be 6.40cm and 7.40cm in the full phase, 4.96cm and 5.96cm in the 20~80% phase, 4.42cm and 5.42cm in the 30~70% phase, and 2.95cm and 3.95cm in the 40~60% phase. In the Gated CBCT, the axial lengths on average was measured to be 6.35 cm in the full phase, 5.25 cm in the 20-80% phase, 4.04 cm in the 30-70% phase, and 3.08 cm in the 40-60% phase. Comparing the results, it was confirmed that the error was within ±8.5% of ITV Conclusion: Conventional CBCT had a problem that errors occurred due to organ movement in areas affected by respiratory movement, but through this study, obtained an image similar to the target volume of the setting phase using Gated CBCT and verified its usefulness. However, as the setting phase decreases, the scan time was increases. Therefore, considering the scan time and the error in setting phase, It is recommended to apply it to patients with respiratory coordinated stereotactic radiation therapy using a wide phase of 30-70% or more.

Surgical Correction of Ectopic Ureter in Dogs (개에서 발생한 이소성 요관의 외과적 교정)

  • Choi, Sung-Jin;Lee, Gi-Ja;Kang, Eun-Hee;Jang, Se-Ung;Hwang, Eui-Hee;Jeong, In-Seong;Kim, Nam-Soo
    • Journal of Veterinary Clinics
    • /
    • v.31 no.2
    • /
    • pp.137-140
    • /
    • 2014
  • A Maltese (case 1) and a Labrador Retriever (case 2) presented with urinary incontinence. General conditions were good and screening tests, including a complete blood count, serum chemistry and radiography, were performed. Excretory urography was conducted, and fluoroscopy was performed for case 1 and computed tomography was performed for case 2. The dogs were diagnosed as right extramural ectopic ureter in case 1 and bilateral intramural ectopic ureter in case 2. We performed surgical corrections, including a neoureterocystostomy for extramural ectopic ureter and neoureterostomy for intramural ectopic ureter. After surgery, the dogs were catheterized with an indwelling catheter for 3 days. Urinary incontinence improved completely and the clinical outcomes were good. The choice of adequate surgical procedure is important for correcting ectopic ureters in canines.

Pulmonary Cryptococcosis (좌하엽 폐침윤)

  • Kim, Gye-Su;Lee, Jae-Cheol;Lee, Seung-Jun;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.113-116
    • /
    • 1996
  • A previously healthy 59-year old male patient was admitted due to cough and abnormal chest x-ray. Cough started 5 months ago and persisted. Two months before admission, abnormality in chest PA was detected. He had no symptom other than cough. He was nonsmoker and physical examination revealed no abnormal finding. His chest X-ray showed ill-defined $2{\times}1\;cm$ ovoid infiltration in left middle lung field. On chest computed tomography, it was located in the subpleural region of posterobasal segment of left lower lobe. Mediastinal lymphadenopathy was absent. Blood test and sputum examination were not diagnostic. Fluoroscopy-guided percutaneous needle biopsy revealed pulmonary cryptococcosis. After central nervous system involvement was excluded by spinal tap, oral ketoconazole therapy was started. The lesion decreased in size after 8 weeks of therapy and almost disappeared on follow-up chest X-ray 4 months later.

  • PDF