• 제목/요약/키워드: Compressor power input

검색결과 52건 처리시간 0.023초

인버터 스크롤 압축기를 사용한 멀티 에어컨의 냉방 특성에 대한 실험적 연구 (Experimental Study on Cooling Characteristics of Multi - Air Conditioner using Inverter Scroll Compressor)

  • 권영철;고국원;진의선;허삼행;전용호;이영덕;박인규
    • 설비공학논문집
    • /
    • 제16권4호
    • /
    • pp.311-317
    • /
    • 2004
  • In the present study, the cooling characteristics of the multi-air conditioner (A/C) using an inverter scroll compressor are experimentally investigated for the number of the indoor units and the operating conditions (2$0^{\circ}C$, 24$^{\circ}C$, 26$^{\circ}C$) under the cooling standard conditions by KS C 9306. In the case of the simultaneous operation for 3 indoor units, the cooling capacity, the mass flow rate and the input power have a decreasing trend and COP has an increasing trend, with decreasing the difference in the operating temperature of the indoor unit and the room temperature. In the case of the simultaneous operation for 2 indoor units, the COP of the indoor unit with large cooling capacity is high when the operating temperature is high, but the COP of the indoor unit with low cooling capacity is high when the operating temperature is low. In the case of the single operation for one unit, when the large cooling capacity of the indoor unit is less than 50% the compressor operates at the minimum operation frequency region and the COP decreases.

고역필터를 사용한 선형압축기 구동용 LPMSM의 새로운 스트로크 계산 기법 (A Novel Method for Calculating the Stroke of LPMSM for Driving Linear Compressor Using High Pass Filter)

  • 안정렬;이홍희;김흥근;노의철;전태원
    • 전력전자학회논문지
    • /
    • 제11권1호
    • /
    • pp.7-13
    • /
    • 2006
  • 근래에 선형전동기로 냉장고 등 냉동기기의 압축기 피스톤을 제어하는 선형압축기가 높은 효율 때문에 많이 주목받고 있다. 선형압축기의 피스톤 스트로크는 LPMSM의 입력 전압 및 전류값을 적분하여 구하며, 이 입력 신호에 직류성분이 포함될 경우 스트로크가 발산된다. 본 연구에서는 고역필터 및 직류 옵셋 보상 방식을 사용하여 입력 전압 및 전류의 직류성분에 의한 스트로크의 발산을 방지하는 기법을 제시하였다. 고역필터의 차단주파수에 대한 스트로크의 크기 및 위상과 스트로크에 포함된 직류옵셋 값의 관계를 유도하고, 직류 옵셋 값을 보상하여 정확한 스트로크를 계산한다. 새로 개발된 스트로크 계산방법의 성능은 16비트 DSP 구현된 선형압축기 시스템의 실험을 통하여 확인하였다.

초전도 필터 냉각용 선형압축기형 맥동관 냉동기의 실험적 연구 (An Experimental Study of the Pulse Tube Cryocooler with the Linear Compressor)

  • 박성제;홍용주;김효봉;고득용;염한길;김양훈;김종학
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.197-201
    • /
    • 2002
  • A free piston and free displacer (FPFD) Stirling cryocooler and inertance pulse tube cryocooler for the cooling infrared detector and cryosensor are currently under development at Korea Institute of Machinery & Materials. The pulse tube cryocooler, which has no moving parts at its cold section, is attractive for obtaining higher reliability, simpler construction and lower vibration than in any other small cryocoolers. In recent years, pulse tube cryocoolers have experienced a rapid development with the aim to eventually replace Stirling and Gifford-McMahon cryocoolers in various applications. In this study, operating characteristics of the conventional linear Stirling cryocooler was investigated by experiment. And, inertance pulse tube cryocooler with the commercial linear compressor(Leybold Polar) was designed, manufactured, and tested by the variations of the operating frequency, charging pressure and input power.

  • PDF

스터링헝 오리피스 맥동관 냉동기의 성능특성에 관한 연구 (Study of the performance characteristics of the Stirling type orifice pulse tube refrigerator)

  • 홍용주;박성제;김효봉;김양훈;최영돈
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권2호
    • /
    • pp.63-67
    • /
    • 2002
  • In this study, the performance of the Stirling type orifice Pulse tube refrigerator (OPTR) with a linear compressor was investigated by experiment. The dynamic pressures at three points and a temperature at the cold heat exchanger are measured to explore the dependency of the orifice on the performance of the OPTR. The experimental results show that the opening of the orifice has significant effects on the no load temperature and cool down characteristics. The Pressure amplitude in Pulse tube decrease as the opening of the orifice increase, but the mass flow rate through the orifice and the electric input Power to the compressor increase. The results show that the operating frequency and charging Pressure does not affect on the no load temperature. The pressure amplitude in pulse tube decrease as the operating frequency increase or the charging Pressure decreased.

수소와 메탄 연료를 사용한 에어 터보 램제트 엔진의 성능해석 (Performance Analysis of Air Turbo Ramjet using $H_2$ and $CH_4$)

  • 이양지;차봉준;양수석;이대성;김형진
    • 한국군사과학기술학회지
    • /
    • 제6권3호
    • /
    • pp.103-110
    • /
    • 2003
  • The present work was conducted to achieve the better understanding of the performance analysis technique for the expander type air turbo ramjet engine. For this purpose, the performance analysis was carried out using a small engine(8.0kN thrust) with two types of fuels. From this analysis, at the same input condition, the thrust of methane-fueled engine was 25% lower than that of hydrogen. In addition, the case of methane shows the inapplicable engine performance cycle.(i.e., The compressor work exceeds the turbine output power) These results come mainly from the different heating value of each fuel and specific heat. This analysis also shows that, to build a same performance cycle as the hydrogen case, the methane-fueled engine requires increased air and fuel flow rates, increased turbine expansion ratio, and decreased compressor pressure ratio.

열펌프를 이용한 R22대체 혼합냉매의 성능에 관한 연구 (A Study on the Performance of HCFC22 and Alternative Refrigerants in Heat Pumps)

  • 송영재;정동수
    • 태양에너지
    • /
    • 제18권1호
    • /
    • pp.69-79
    • /
    • 1998
  • This paper is concerned about the performance of HCFC22 alternative refrigerants used in heat pumps and industrial chillers. A water-to-water breadboard heat pump with counter-current heat exchangers and a hermetic compressor was built to carry out the experiments with various refrigerants. For each test, more than 40 temperatures, 4 pressures, power input, mass flow rates of the heat transfer fluids were measured. Refrigerants tested were HCFC22, R290(Propane), an azeotrope of 45%Propane/55%R134a mixture, and a nonazeotropic mixture of Calor 50. All tests were conducted under ARI test A condition. It is found that the COP and capacity of propane were 18% and 2.5% higher than those of HCFC22 while the COP and capacity of 45%Propane/55%R134a mixture were 3.5% and 5.3% higher than those of HCFC22 respectively. Also the COP and capacity of Calor 50 were 17% and 7.8% higher than those of HCFC22. Compressor discharge temperatures of alternative refrigerants were roughly $35^{\circ}C$ lower than that of HCFC22 indicating that these refrigerants are good from the view point of compressor reliability. The charging amounts for the alternative refrigerants were reduced by 40-60% as compared to that of HCFC22. Overall, it can be said that hydrocarbon containing alternative refrigerants are excellent in thermodynamic performance but should be used with considerable care due to their flammability.

  • PDF

부분 스위칭 PFC 모듈을 이용한 가정용 에어컨 전원장치 (The Power System for Home Appliance Air-Conditioner using Partial Switching Power Factor Correction Module)

  • 서기영;문상필
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.183-190
    • /
    • 2004
  • 본 논문은 냉난방 인버터 에어컨용 전원시스템에 역률개선 회로인 부분 스위칭 PFC 모듈을 적용하여 입력의 역률 개선 및 전류의 고조파 성분을 최소화하여 IEC555-2규정을 만족하는 입력 전원부를 설계하여 인덕터부하에 적용되는 회로 설계시의 문제점들을 해결 할 수 있는 방안들을 제시하였다. 그리고 출력전압의 상승을 억제하면서 전류파형을 개선하는 방법 및 부분 스위칭 PFC회로를 제안하여 스위칭 횟수를 적게 함으로써 압축기의 모터에 인가 할 수 있는 전압을 상승시켜 모터 적정 운전 전압을 확립하였으며, 효율이나 경제성 및 전자 노이즈 등의 문제점들을 해결하였다. 그리고 에어컨의 소비 전력을 줄일 수 있다. 이상의 결과에서 시스템 총합 운전에너지 효율이 상승되는 것을 확인하는 모든 사항은 시뮬레이션과 실험을 통하여 그 타당성을 입증했다.

리니어엔진을 이용한 파워팩의 운전조건에 따른 발전출력에 관한 연구 (A Study for Generating Power on Operating Parameters of Powerpack utilizng Linear Engine)

  • 오용일;김강출;임옥택
    • 한국수소및신에너지학회논문집
    • /
    • 제23권2호
    • /
    • pp.183-190
    • /
    • 2012
  • The research shows the experiment results according to the combustion characteristics and configuration of the linear generator of powerpack for the generating power applying the 2-stroke compact linear engine. The powerpack used in this paper consists of 2-stroke linear engine, linear generator and air compressor parts. For identifying the combustion characteristics and generating power of linear engine, some parameters were varied sucha as electric load, fuel input calorie, spark timing delay and equivalence ratio. Also generating power was confirmed at each operation conditions, when the air gap length of linear generator part was changed as each 1.0 mm and 2.0 mm. During the all operations, intake air was inputted under the wide open throttle. Mass flow rate of air and fuel was changed using mass flow controller, after these were premixed by premixture device, and then premixed gas was supplied directly into each cylinder. As a result, piston frequency and combustion characteristics were different at each conditions according to parameters affecting the combustion such as fuel input calorie, resistive load, spark timing delay and equivalence ratio. Consequently, these had an effect on generating power.

동적시뮬레이션을 위한 시스템 멀티에어컨의 모델링 (Modelling of System Air-Conditioner for Dynamic Simulation)

  • 이윤종;김찬중;문제명;김철우;서형준;김경록;신행조;홍희기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.328-333
    • /
    • 2007
  • The purpose of this study is modelling of system air-conditioner for TRNSYS. System air-conditioner is operated by a variable capacity compressor and accommodated by multiple evaporators. By reason of these feature, realizing performance of system air-conditioner for TRNSYS was incomplete. In this study performance data of system air-conditioner and control logics are used to make system air-conditioner module for TRNSYS. Performance data contains total capacity, power input and capacity index of system air-conditioner. The simulation was carried out in a mode of temperature level control using TRNSYS 16. The simulation shows that the system air-conditioner model operate variable capacity and can compute capacity index and power input of system.

  • PDF

주위온도조건이 스터링 극저온냉동기의 성능에 미치는 영향 (Effects of the environmental temperature on the performance of the Stirling cryocooler)

  • 홍용주;김효봉;박성제
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권3호
    • /
    • pp.65-68
    • /
    • 2009
  • The Stirling cryocoolers have been widely used for the cooling of the infrared detector(InSb, HgCdTe, and etc,) and HTS(High Temperature Superconductor) to the cryogenic temperature. The monobloc Stirling cryocoolers with the rotary compressor are applicable to the cooling device for the compact mobile thermal imaging system, because the cryocoolers have the compact structure and light weight. The typical performance factors of the Stirling cryocooler are the cool-down time, cooling capacity at the desired temperature (80 K), the electric input power and COP. The above performance factors depend on the operating conditions such as the charging pressure of the helium gas, the thermal environment and etc.. In this study, the effects of the thermal environment (temperature of 241, 293, and 333 K) on the performance of the cryocooler were investigated by experiments. The results show the effects of the temperature of the thermal environment on the cooling capacity and input power.