• 제목/요약/키워드: Compressor Characteristics

Search Result 651, Processing Time 0.024 seconds

Two Dimensional Complex Sound Intensity를 이용한 압축기 소음원 규명에 관한 연구 (A Study on Noise Identification of Compressor Based on Two Dimensional Complex Sound Intensity)

  • 안병하;김영수
    • 한국정밀공학회지
    • /
    • 제17권1호
    • /
    • pp.83-92
    • /
    • 2000
  • Sound intensity method is well known as a visualization technique of sound field or sound propagation in noise control. Sound intensity or energy flux is a vector quantity which describes the amount and the direction of net flow of acoustic energy at a given position. Especially two dimensional sound intensity method is very useful in evaluating periodic characteristics and acoustic propagation mode of noise source. In this paper, we have studied the noise source Identification, acoustic sound field analysis, and characteristics of noise source of rotary compressor and scroll compressor for air conditioner using complex sound intensity method. Also we proposed a now method of time domain analysis which is used in evaluating of position of noise source in rotary and scroll compressor in this paper This paper presents the advantage, simplicity and economical efficiency of this method by analysing the characteristics of noise source with two dimensional complex sound intensity simultaneously.

  • PDF

산업용 냉각기의 압축기 회전수 변화에 따른 용량제어 특성 (The characteristics of capacity control using a variable speed compressor in an industrial cooler)

  • 백승문;문춘근;윤정인;정석권;김은필
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.37-41
    • /
    • 2011
  • This paper presents the capacity-control characteristics in an industrial cooler with a variable speed compressor. The inverter-type compressor is controlled by the rotational speed of the operational frequency. This type of the compressor performs the wide range of load compared to the on-off type. When the load of the system reduces, the rotational speed will be reduced. Thus, the system leads to the less power consumption and extends the longer durability of the compressor. With the variable rotational speed of the compressor the cooling capacity of the cooler is about 1.6-3.6 kW and the capacity control is about 40-100%. The system showed the highest efficiency when the rotational speed is about 45-70 Hz. The results can be used as the basic design data to control an industrial cooler.

스크롤 압축기 윤활시스템의 수치해석과 실험 (Numerical Simulation and Experimental Studies on Lubricating System of Scroll Compressor)

  • 이진갑;김종봉
    • 한국정밀공학회지
    • /
    • 제21권2호
    • /
    • pp.108-115
    • /
    • 2004
  • Experiment and analytical studies on the oil supply characteristics of scroll compressor have been presented. For a scroll compressor, oil supply system consisting of individual lubricating element such as pumps, oil passages and sliding surfaces has been modeled by equivalent electric circuit. By solving the closed network equations of the model, oil flow rates at various lubrication elements could be obtained. Total amount of the oil flow rate drawn into the shaft has been measured and compared reasonably well with the prediction by the numerical simulation.

로터리 컴프레서 방사소음의 실험적 저감 (Experimental Reduction of the Noise Radiated by Rotary Compressor)

  • 박상영;이상현;이수일;이장무
    • 소음진동
    • /
    • 제9권1호
    • /
    • pp.189-195
    • /
    • 1999
  • The noise radiated by the rotary compressor for a room air-conditioner was investigated experimentally. Noise characteristics and structural eigen modes of the compressor were identified through sound tests and modal tests each other. From these tests. we found that the accumulator has a big contribution to the noise radiation. So, various structural modifications for the accumulator were performed and these modification methods were found efficient to the noise reduction from verification tests.

  • PDF

부분구조합성법을 이용한 컴프레서 쉘의 동특성 규명 및 개선에 관한 연구 (A Study on the Identification & Improvement of Dynamic Characteristics of Compressor Shell by Substructure Synthesis Method)

  • 김동규;김종배;고상철;한광희;오재응
    • 한국음향학회지
    • /
    • 제15권5호
    • /
    • pp.99-106
    • /
    • 1996
  • 컴프레서의 소음은 냉장고로부터 발생하는 전체 소음레벨중 높은 기여를 나타낸다. 그리고, 컴프레서로부터 방사되는 소음의 상당부분이 컴프레서 쉘의 진동에 의해 방사되는 소음이다. 본 연구에서는 컴프레서 쉘의 동특성을 규명하기 위하여 범용 구조해석 패키지인 MSC/NASTRAN을 이용하여 컴프레서 쉘을 여러 분계로 분리하여 해석한 뒤, 부분구조 합성법을 이용하여 전계의 동특성을 규명하였다. 그리고 각 분계의 변형 에너지와 운동에너지를 산정하여 각 분계가 전계에 기여하는 정도를 파악하였다. 컴프레서 소음에 가장 높은 영향을 미치는 1차모드를 고주파로 이동시키기 위하여, 1차 모드에 기여가 높은 분계의 질량과 강성을 변경하여 컴프레서 쉘의 동특성 개선 방향을 제시하였다.

  • PDF

다단 천음속 압축기의 유동 불안정성에 관한 실험적 연구 (Experimental Research on Aerodynamic Instabilities in a Multi Stage Transonic Axial Compressor)

  • 강영석;박태춘;황오식;임형수;양수석
    • 한국유체기계학회 논문집
    • /
    • 제15권2호
    • /
    • pp.12-19
    • /
    • 2012
  • This study presents unsteady and unstable characteristics of three stage transonic axial compressor, developed by Korea Aerospace Research Institute. As approaching to the unstable operating region at the 103% design speed of the compressor, a modal type stall precursor appears in front of highly loaded 3rd rotor row at first, and it propagates to the upstream. On the contrary, actual stall cell initiates from the stall precursor in front of the 1st rotor row, and it propagates to the downstream of the compressor. After the stall region reached the 3rd stage and stall cell rotates circumferentially about 360 deg, it develops to one dimensional compressor surge mode. It shows a mild surge behaviour with 3~4 Hz frequency. From the test data, it can be suggested that there is a priority to give an optimum blade loading distributions to construct a multi stage transonic axial compressor stages either to secure more stable compressor operating ranges, or to maximize the compressor efficiency.

통계적 에너지 해석 기법에 의한 밀폐형 회전 압축기의 소음진동 전달경로 해석 (A Study on the Noise and Vibration Path of Hermetic Rotary Compressor by SEA)

  • 황선웅;안병하;정현출;정의봉;김규환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.869-874
    • /
    • 2002
  • Hermetic rotary compressor is one of the most important components for air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration of rotary compressor is occurred due to gas pulsation during compression process and unbalanced dynamic force. In order to reduce noise and vibration, It is necessary to identify sources of noise and vibration and effectively control them. Many approaches have been tried to identify noise sources of compressor. However, compressor noise source identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this work, Statistical Energy Analysis has been used to trace the energy flow in the compressor and identify transmission paths from the noise source to the sound field.

  • PDF

Defect classification of refrigerant compressor using variance estimation of the transfer function between pressure pulsation and shell acceleration

  • Kim, Yeon-Woo;Jeong, Weui-Bong
    • Smart Structures and Systems
    • /
    • 제25권2호
    • /
    • pp.255-264
    • /
    • 2020
  • This paper deals with a defect classification technique that considers the structural characteristics of a refrigerant compressor. First, the pressure pulsation of the refrigerant flowing in the suction pipe of a normal compressor was measured at the same time as the acceleration of the shell surface, and then the transfer function between the two signals was estimated. Next, the frequency-weighted acceleration signals of the defect classification target compressors were generated using the estimated transfer function. The estimation of the variance of the transfer function is presented to formulate the frequency-weighted acceleration signals. The estimated frequency-weighted accelerations were applied to defect classification using frequency-domain features. Experiments were performed using commercial compressors to verify the technique. The results confirmed that it is possible to perform an effective defect classification of the refrigerant compressor by the shell surface acceleration of the compressor. The proposed method could make it possible to improve the total inspection performance for compressors in a mass-production line.

다단 축류압축기의 표면조도가 성능에 미치는 영향 (Roughness effect on performance of a multistage axial compressor)

  • 한경호;강영석;강신형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.264-270
    • /
    • 2002
  • This paper presents roughness effects on flow characteristics and efficiency of multi-stage axial compressor using numerical simulation. which is carried out with a commercially available software, CFX-TASCflow. In this paper, the third of four stages of GE low pressure compressor is considered including me stator and rue rotor. Mixing-plane approach is adopted to model the interface between the stator and the rotor: it is appropriate for steady state simulation. First, a flat plate simulation was performed to validate how exact the numerical simulation predicts the roughness effect for smooth and rough walls. Then GE compressor model was calculated about at each roughness height. Concluding, very small roughness height largely affects the performance of compressor and the increasing rate of loss decrease as roughness height increase.

  • PDF

Development of Hybrid Electric Compressor Motor Drive System for Hybrid Electrical Vehicles

  • Jung, Tae-Uk
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.960-968
    • /
    • 2009
  • This paper presents a design optimization process for interior permanent magnet synchronous motors (IPMSM) for hybrid electric compressors (HEC) which are applied to hybrid electrical vehicles. A hybrid electric compressor is composed of an electric motor driving section and an engine driving section which is connected to the engine by a pulley belt. A hybrid electric compressor driving motor requires half of the full driving power of a compressor. Even though an engine is not operated at the idling stop mode, the electric motor drives the air-conditioner compressor by itself so that the air conditioning system can produce its minimum cooling capacity. In this paper, the design optimization of an IPMSM for a 42 (V) applied voltage system is studied using the design of experiment (DOE) and response surface method (RSM) of 6sigma. The driving characteristics of this motor drive system are measured and analyzed by experiment.