• 제목/요약/키워드: Compressive strength properties

검색결과 3,597건 처리시간 0.028초

소성볏짚을 혼입한 모르타르의 압축강도 특성에 관한 연구 (A Study on the Compressive Strength Property of Mortar using Rice Straw Ash)

  • 정의창;신상엽;김영수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 추계 학술논문 발표대회
    • /
    • pp.265-266
    • /
    • 2012
  • The purpose of this study was to investigate the compressive strength property into mortar using rice straw ash. In an effort to evaluate the effects of rice straw ash firing temperatures on compressive strength properties of mortar, a change in the components of rice straw ash was observed according to firing temperatures, and compressive strength of mortar and X.R.F was measured. As a results, As the mortar with a mixture ratio of rice straw ash up to 15% was found to have a compressive strength superior to that of plain mortar.

  • PDF

고강도 콘크리트의 역학적 특성에 대한 실험 연구 (An Experimental Study of Mechanical Properties of High-strength Concrete)

  • 양인환;황철성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권6호
    • /
    • pp.206-215
    • /
    • 2017
  • 이 연구에서는 고강도 콘크리트의 역학적 특성을 파악하기 위한 실험연구를 수행하였다. 80~120 MPa 범위의 압축강도를 갖는 고강도 콘크리트를 대상으로 실험연구를 수행하였다. 물-결합재비의 압축강도에 대한 영향, 시간에 따른 압축강도의 발현 및 양생조건의 압축강도에 대한 영향을 분석하였다. 또한, 양생조건에 따른 콘크리트의 탄성계수, 쪼갬인장강도 및 파괴계수 특성을 파악하였다. 탄성계수, 쪼갬인장강도 및 파괴계수의 실험결과와 기존설계코드에 의한 예측결과를 비교하였다. 콘크리트구조기준의 탄성계수 제안식은 실험값을 합리적으로 예측한다. 반면에, 콘크리트구조기준은 파괴계수 실험값을 과소평가하고 있다. ACI 363R의 쪼갬인장강도와 파괴계수 예측값과 실험값은 잘 일치하고 있다. 따라서, ACI 363R의 쪼갬인장강도와 파괴계수 예측식은 120 MPa까지의 고강도 콘크리트에 효과적으로 활용될 수 있다.

비정질강섬유 보강 고강도 콘크리트의 온도별 잔존 역학적 특성 평가 (The residual mechanical properties evaluation according to temperature of the amorphous metallic fiber reinforced high strength concrete)

  • 서동균;김규용;이상규;황의철;유하민;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.98-99
    • /
    • 2020
  • This study is aim to assess mechanical properties which is highly related to structural safe and durability of 100MPa high strength concrete mixed with amorphous metallic fiber. All specimens were heated with low velocity heating rate(1℃/min.), residual compressive strength and residual flexural strength was evaluated. The specimens were cooled down to room temperature after heating. As a result, in the case of 100MPa high-strength concrete, the residual compressive strength enhancing effect of amorphous metallic fiber has showed with the mix proportion of fiber. In addition, residual flexural strength showed more regular pattern before 300℃ then residual compressive strength, but simillar decreasing behavior was shown after 300℃ like residual compressive strength. Further study about fiber pull-out behavior and fiber mechanical, chemical property change due to temperature is needed.

  • PDF

고강도콘크리트 벽체부재에 접합분리 시험체를 활용한 강도관리에 관한 연구 (Compressive Strength Control of High Strength Concrete Structure Using Samples with Isolated Junction Test)

  • 기전도;김학영;김광기;백민수;임남기;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.47-50
    • /
    • 2009
  • The existing techniques used to estimate and manage the compressive strength of concrete do not include the environmental factors that influence the development of compressive strength and the compressive strength itself. Thus, it is necessary to develop a reasonable yet simple way to measure the compressive strength of concrete structures at construction sites by considering concrete's mechanical properties and curing environment. This study was conducted to propose an acrylic form and a junction isolation mold with crack-inducing boards that uses non-destructive methods to create and collect concrete test samples that are cured in the same condition as the actual concrete structures. junction isolation molds were used in high-strength and super high-strength concrete to evaluate the reliability of compressive strength evaluation on the test sample. The following were the findings of this study:

  • PDF

시공정밀도에 따른 비구조용 콘크리트벽돌 조적벽체의 프리즘 압축강도 (Prism Compressive Strength of Non-structural Concrete Brick Masonry Walls According to Workmanship)

  • 신동현;김형준
    • 대한건축학회논문집:구조계
    • /
    • 제36권2호
    • /
    • pp.127-136
    • /
    • 2020
  • Prism compressive strength is the most influential parameter to evaluate the seismic performance of non-structural concrete brick masonry walls, and is affected by the practice and workmanship of masonry workers. This study experimentally investigates the influence of workmanship on prism compressive strength throughout the compressive test with prism specimens constructed according to masonry workmanship. To do this, the workmanship is categorized into good, fair, and poor conditions which are statistically evaluated with thickness and indentation depth of bed-joints. Then, the effect of workmanship on the structural properties of masonry prisms is evaluated by investigating relations between properties such as their compressive strength, elastic modulus and numerical parameters such as thickness, filling of bed-joints. This study demonstrates that the indentation depth is more important parameter for structural properties of masonry prisms and masonry prisms with loss in bed-joint area less than of 7% can be in fair condition.

셰일암 골재 콘크리트의 역학적 특성에 관한 실험 (An Experimental Study on the Property of Unconfined Strength of Concrete Specimen with Shale Rock Aggregates)

  • 이석훈;홍성남;김광수;한경봉;박선규
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.447-450
    • /
    • 2005
  • The purpose of this study is to investigate properties of compressive strength of concrete using the shale rock as coarse aggregates. To evaluate properties of compressive strength of concrete using crushed shale rock, we performed the expriment according to the proportioning strength of $10MPa\~40MPa$ and the slupm of $12\%\~15\%$. The result of this study is as follow. The compressive strength of concrete using crushed shale rock is lower than those of granite aggregates. The proportioning strength is higher, the reduction of comperssive strength of concrete using the shale rock is higher.

  • PDF

재활용 플라스틱 섬유보강 콘크리트의 역학적 특성 (The Mechanical Properties of Recycled Plastic Fiber-Reinforced Concrete)

  • 양인환
    • 한국건설순환자원학회논문집
    • /
    • 제2권3호
    • /
    • pp.225-232
    • /
    • 2014
  • 이 연구에서는 재활용 플라스틱 섬유 (recycled plastic fibers)로 보강된 콘크리트의 역학적 특성을 파악하고자 하였다. 부피비 0, 0.5, 1.0, 1.5 및 2.0%의 섬유비를 갖는 재활용 섬유보강 콘크리트의 역학특성 실험결과를 분석하였다. 섬유보강 콘크리트의 압축강도, 탄성계수, 인장강도와 길이변화 특성 실험을 수행하였다. 실험결과는 섬유비가 증가함에 섬유보강 콘크리트의 압축강도와 탄성계수는 증가하는 것을 나타낸다. 또한, 재활용 섬유보강 콘크리트는 일반콘크리트에 비해 쪼갬인장강도, 휨인장강도, 균열개구변위 및 길이변화에 우수한 특성을 나타낸다. 연구결과는 추후 재활용 플라스틱 섬유보강 콘크리트의 재료 모델을 위한 실제적인 기초실험자료로 활용될 수 있을 것으로 사료된다.

PZT의 파괴거동 및 압전 열화특성 (Fracture Behavior and Degradation of Piezoelectric Properties in PZT)

  • 태원필;김송희;조상희
    • 한국세라믹학회지
    • /
    • 제29권10호
    • /
    • pp.806-814
    • /
    • 1992
  • The aim of this study was to investigate the change in compressive strength, freacture behavior and degradation of piezoelectric properties with compressive cyclic loading in Pb(Zr, Ti)O3 of tetragonal, morphotropic phase boundary and rhombohedral composition. The highest compressive strength was found in rhombohedral composition. After poling treatment the strength increased by 8.4% and 6.5% in tetragonal and morphotropic phase boundary compositions respectively while changed little in rhombohedral. The increase of compressive strength after poling treatment is believed to be due to the internal stress around grain boundary by domain alginment toward electric field direction in the microstructures having tetragonality and the occurrence of domain switching to the direction perpendicular to electrical field during fracture. Fracture mode relatively change from transgranular to intergranular was observed in the large grain sized tetragonal and morphotropic phase boundary compositions before and after poling but the transgranular fracture mode always remained in the rhombohedral composition. From the X-ray diffractometer analysis the domains parallel to the electric field direction is known to undergo rearrangement during the cyclic loading into random direction that is responsible for the degradation of piezoelectric property.

  • PDF

골재 종류 및 SP제 변화가 초고성능 콘크리트 기초적 특성에 미치는 영향 (Effect of Aggregates Kinds and Superplasticizer on Fundamental Properties of Ultra High Performance Concrete)

  • 이홍규;정상운;조만기;한동엽;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.55-56
    • /
    • 2014
  • In this research, the effect of types of aggregate and SP on fundamental properties of ultra-high performance concrete of 80 MPa of compressive strength was evaluated to provide solution for high cost of ultra-high performance concrete. As the results of a series of tests, the mixture using limestone and silica aggregates showed improved workability rather than the mixture using granite aggregate. For compressive strength of UHPC, the UHPC mixtures using limestone and silica aggregates showed higher compressive strength than the UHPC mixture using granite aggregate while all mixtures satisfied target compressive range.

  • PDF

페로니켈 슬래그 미분말의 분말도 변화에 따른 모르타르의 건조수축 및 압축강도 특성 (Drying Shrinkage and Compressive Strength Properties of Mortar by the Blaine of Ferro-Nickel Slag Powder)

  • 김영욱;김도빈;김정현;반준모;최세진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.98-99
    • /
    • 2017
  • This study investigated the drying shrinkage and compressive strength properties of mortar by the blaine of ferro-nickel slag powder to estimate the applicability of ferro-nickel slag powder for cement replacement materials. As a test result, the blaine of ferro-nickel slag powder increased, the compressive strength increased and the shrinkage rate decreased.

  • PDF