Efficacy of supplementary cementitious material and hybrid fiber to develop the ultra high performance hybrid fiber reinforced concrete

  • Sharma, Raju;Bansal, Prem Pal
    • Advances in concrete construction
    • /
    • v.8 no.1
    • /
    • pp.21-31
    • /
    • 2019
  • The rich recipe of ultra high performance concrete (UHPC) offers the higher mechanical, durability and dense microstructure property. The variable like cement/sand ratio, amount of supplementary cementitious material, water/binder ratio, amount of fiber etc. alters the UHPC hardened properties to any extent. Therefore, to understand the effects of these variables on the performance of UHPC, inevitably a stage-wise development is required. In the present experimental study, the effect of sand/cement ratio, the addition of finer material (fly ash and quartz powder) and, hybrid fiber on the fresh, compressive and microstructural property of UHPC is evaluated. The experiment is conducted in three phases; the first phase evaluates the flow value and strength attainment of ingredients, the second phase evaluates the efficiency of finer materials (fly ash and quartz powder) to develop the UHPC and the third phase evaluate the effect of hybrid fiber on the flow value and strength of ultra high performance hybrid fiber reinforced concrete (UHP-HFRC). It has been seen that the addition of fly ash improves the flow value and compressive strength of UHPC as compared to quartz powder. Further, the usage of hybrid fiber in fly ash contained matrix decreases the flow value and improves the strength of the UHP-HFRC matrix. The dense interface between matrix and fiber and, a higher amount of calcium silicate hydrate (CSH) in fly ash contained UHP-HFRC is revealed by SEM and XRD respectively. The dense interface (bond between the fiber and the UHPC matrix) and the higher CSH formation are the reason for the improvement in the compressive strength of fly ash based UHP-HFRC. The differential thermal analysis (DTA/TGA) shows the similar type of mass loss pattern, however, the amount of mass loss differs in fly ash and quartz powder contained UHP-HFRC.

Effect of Specimen Sizes and Shapes on Compressive Strength of Concrete (콘크리트의 압축강도에 공시체의 크기와 형상이 미치는 영향)

  • Yang Eun-Ik;Choi Joong-Cheol;Yi Seong-Tae
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.375-382
    • /
    • 2004
  • The compressive strength of concrete is used as the most basic and important material Property when reinforced concrete structures are designed. It has become a problem to use this value, however, because the control specimen sizes and shapes are different from every country. In this study, the effect of specimen sizes and shapes on compressive strength of concrete specimens was experimentally investigated based on fracture mechanics. Experiments for the Mode I failure was carried out by using cylinder, cube, and prism specimens. The test results are curve fitted using least square method(LSM) to obtain the new parameters for the modified size effect law(MSEL). The analysis results show that the effect of specimen sizes and shapes on ultimate strength is apparent. In addition, correlations between compressive strengths with size, shape, and casting direction of the specimen are investigated. For cubes and prisms the effect of placing direction on the compressive strength was investigated.

Evaluation of electromechanical properties in REBCO CC tapes under transverse compression using anvil test method

  • Diaz, Mark Angelo;Shin, Hyung-Seop
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.3
    • /
    • pp.57-61
    • /
    • 2022
  • One of the major applications of REBCO coated conductor (CC) tapes is in superconducting magnets or coils that are designed for high magnet fields. For such applications, the CC tapes were exposed to a high level of stresses which includes uniaxial tensile or transverse compressive stresses resulting from a large magnetic field. Thus, CC tapes should endure such mechanical load or deformation that can influence their electromechanical performance during manufacturing, cool-down, and operation. It has been reported that the main cause of critical current (Ic) degradation in CC tapes utilized in coil windings for superconducting magnets was the delamination due to transversely applied stresses. In most high-magnetic-field applications, the operating limits of the CC tapes will likely be imposed by the electromechanical properties together with its Ic dependence on temperature and magnetic field. In this study, we examined the influence of the transverse compressive stress on the Ic degradation behaviors in various commercially available CC tapes which is important for magnet design Four differently processed REBCO CC tapes were adopted to examine their Ic degradation behaviors under transverse compression using an anvil test method and a newly developed instantaneous Ic measurement system. As a result, all REBCO CC tapes adopted showed robustness against transverse compressive stresses for REBCO coils, notably at transverse compressive stresses until 250 MPa. When the applied stress further increased, different Ic degradation behaviors were observed depending on the sample. Among them, the one that was fabricated by the IBAD/MOCVD process showed the highest compressive stress tolerance.

Property change of geopolymers after immersion (지오폴리머의 침지 후 물성변화)

  • Kim, Hakmin;Kim, Yootaek
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.6
    • /
    • pp.247-257
    • /
    • 2021
  • This study was started to investigate why autoclave curing (AC) specimen showed an improvement in compressive strength after immersion in water for a long time, although AC specimen did not showed a high initial compressive strength unlike our expectations. Distilled water and alkaline solutions were used for immersion and three different curing methods were engaged. It was expected that the compressive strength would be improved after immersion in alkaline solutions; however, there was little difference in compressive strength after 21 day immersion because both new crystallites produced by additional geopolymerization and expansion caused by the alkaline aggregate reaction may prevent the additional improvement in compressive strength. It was concluded that in order to secure the long-term commonality and underwater stability of the geopolymers, it is desirable aging geopolymers while immersing it underwater for more than 21 days after curing using an autoclave.

Enhancement of Electrochemical and Mechanical Properties of 3D Graphene Nanostructures by Dopamine-coating (도파민 코팅을 이용한 3차원 그래핀 나노 구조체의 전기화학적/기계적 특성 향상 연구)

  • Lee, Guk Hwan;Luan, Van Hoang;Han, Jong Hun;Kang, Hyun Wook;Lee, Wonoh
    • Composites Research
    • /
    • v.32 no.6
    • /
    • pp.388-394
    • /
    • 2019
  • Inherited the excellent electrical and mechanical properties based on the low dimensional structure of graphene, three-dimensional graphene nanostructures have gathered great attention as electrochemical energy storage electrodes owing to their high porosity and large specific surface area. Also, having the catecholamine structure, dopamine has been regarded as a multifunctional material to possess high affinity to various organic/inorganic materials and to modify a hydrophobic surface to a hydrophilic one. In this work, through coating dopamine on the three-dimensional graphene nanostructure, we tried to increase the specific capacitance by enhancing the wettability with electrolyte and to improve the mechanical compressive property by strengthening the nano-architecture. As a result, the dopamine-coated nanostructure exhibited significant improvement on the specific capacitance (51.5% increase) and compressive stress (59.6% increase).

Evaluation of Mechanical and Durability Performance of Mortar Shotcrete (모르타르 숏크리트의 역학성능 및 내구성능 평가)

  • Park, Byoungsun;Jang, Kun Young;Choi, Young Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.68-74
    • /
    • 2019
  • In this study, the mechanical property and durability of improved bond performance mortar shotcrete was investigated. Mortar shotcrete was prepared by replacing coarse aggregate with 100% fine aggregate in the shotcrete mixture proportion proposed in the road construction standard specification. OPC, GGBFS and anhydrite were used as binders, and polymer powder was substituted for 1% and 2% of binder for improving bond property. From the experimental results, it was found that the compressive strength decreased with increasing polymer addition, but the bond strength increased. The addition of polymer to mortar shotcrete also reduced the drying shrinkage and improved the resistance to carbonation. Initial hydration heat of mortar shotcrete decreased with the addition of polymer, and it was judged that the initial compressive strength decreased.

Characteristics Strength of Silicasol-cement Grout Material for Ground Reinforcement (지반보강용 실리카졸 약액의 강도특성에 대한 연구)

  • Kim, Hyunki;Kim, Younghun;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.9
    • /
    • pp.47-53
    • /
    • 2010
  • This study was made on the fact that the compressive strength characteristic of the recently developed alkali silica-sol chemical grout material was examined, whose grout material used for this study was designed to understand its strength property through the uniaxial compressive strength test(homo-gel, sand-gel), permeability test, deflection strength test, etc. In order to compare with the engineering characteristics regarding alkali silica-sol grout material and sodium silicate grout material. The uniaxial compressive strength of silica-sol grout material was identified to be increased more than 3~5 times than sodium silicate grout material at the early stage(within 72 hours). When comparing with the uniaxial compressive strengths of Sand-gel and Homo-gel at the material age of 28 days in case of silica-sol grouting material the strength of Sand-gel was measured to be about 1.3 times higher than Homo-gel. In case of silica-sol, it is assumed to have the property to exert high strength when it is actually grouted into the ground. As a result of permeability test it is judged that it is possible to apply the silica-sol to the site in the place requiring the water cut-off as the silica-sol. As a result of testing the strength at the material age of 28 days of grouting-use silica-sol showed more than 3 times' difference than the sodium silicate grouting material.

Consumer's Sensory Evaluation and Needs of Interior Fabrics for Seat Cover (시트커버용 인테리어 직물의 감성평가와 소비자 요구도)

  • Kim, Jeong-Hwa;Lee, Sun-Young;Lee, Jung-Soon
    • Korean Journal of Human Ecology
    • /
    • v.18 no.3
    • /
    • pp.749-756
    • /
    • 2009
  • Keeping abreast with the latest consumer's trends, industries are focusing on sensibility aspects of products to meet consumer's needs. The car(?) seat cover fabrics are more closely related to human senses than anything else. This study attempted to investigate which seat cover fabric can give good feeling to consumers and to analyze their characteristics. Twelve kinds of jacquard fabric used for seat cover were selected. The Kawabata Evaluation System was used to measure the mechanical properties of 12 jacquard fabrics, and tactile sensibility(TS), and preference(P) determined by subjective evaluation of 160 participants were also utilized. The stepwise regression analysis was made to select the most significant mechanical properties, and some models for predicting tactile sensibility and preference was developed. The results are briefly summarized as follows: the most important parameter to choose seat cover fabric is a "hygienic property" and the other parameters are 'materials with color fastness', 'compressive property', 'color', 'antibacterial property', 'easy-care property'. The LogSMD, LogB, LC, EM were selected as significant mechanical properties affecting tactile sensibility. Also, the LC, LogB, LogSMD, LogWC, LogMMD were selected as significant mechanical properties affecting preference.

Stiffness Comparison of Tissue Phantoms using Optical Coherence Elastography without a Load Cell

  • Chae, Yu-Gyeong;Park, Eun-Kee;Jeon, Min Yong;Jeon, Byeong-Hwan;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.17-22
    • /
    • 2017
  • Mechanical property of tissue is closely related to diseases such as breast cancer, prostate cancer, cirrhosis of the liver, and atherosclerosis. Therefore measurement of tissue mechanical property is important for a better diagnosis. Ultrasound elastography has been developed as a diagnostic modality for a number of diseases that maps mechanical property of tissue. Optical coherence elastography (OCE) has a higher spatial resolution than ultrasound elastography. OCE, therefore, could be a great help for early diagnosis. In this study, we made tissue phantoms and measured their compressive moduli with a rheometer measuring the response to applied force. Uniaxial strain of the tissue phantom was also measured with OCE by using cross-correlation of speckles and compared with the results from the rheometer. In order to compare stiffness of tissue phantoms by OCE, the applied force should be measured in addition to the strain. We, however, did not use a load cell that directly measures the applied force for each sample. Instead, we utilized one silicone film (called as reference phantom) for all OCE measurements that indirectly indicated the amount of the applied force by deformation. Therefore, all measurements were based on displacement, which was natural and effective for image-based elastography such as OCE.

Compressive Strength Generation Properties of Concrete using a Large Amount of Industrial Byproduct (산업부산물을 다량 사용한 콘크리트의 압축강도 발현 특성 검토)

  • Kim, Yong-Ro;Song, Young-Chan;Park, Jong-Ho;Jeong, Yong
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.2
    • /
    • pp.67-73
    • /
    • 2011
  • In this study, it was investigated compressive strength generation of concrete using high volume mineral admixture obtaining fundamental data for the application of concrete structure in construction field. For this, it was evaluated compressive strength with unit binder contents($310{\sim}410kg/m^3$), replacement ratio of mineral admixture(70~90%), unit water contents($140{\sim}150kg/m^3$) and curing temperature in the normal strength range. Also, after producing mock-up structure, hydration heat and compressive strength generation was evaluated to examine properties in the concrete member. In case of concrete using a large amount of industrial byproducts which was reviewed in this study, it is possible to secure compressive strength more than 24MPa at age 28days with about $13^{\circ}C$ ambient temperature of curing condition and that is considered to be applied to structure at construction site.

  • PDF