• Title/Summary/Keyword: Compressive force

Search Result 614, Processing Time 0.025 seconds

The Moment-Curvature Relationship of the Rectangular Ultra High Performance Fiber Reinforced Concrete Beam (초고강도 섬유보강 직사각형 콘크리트보의 모멘트-곡률 관계)

  • Han, Sang-Mook;Guo, Qing-Yong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.11 no.3
    • /
    • pp.9-15
    • /
    • 2011
  • The flexural behavior of the UHPFRC rectangular beam which has 100 MPa, 140 MPa compressive strength were compared with that of the typical RPC rectangular beam which has same geometrical shape, prestressd force and 160 MPa compressive strength. UHPFRC beam was not reinforced at all and the variable of test is fraction of steel fiber, compressive strength of concrete, method of prestressing and ratio of prestressing bar. The behavior of UHPFRC beam was analysed by relationship of moment - curvature and load - deflection. Simple modeling of stress-strain of UHPFRC was proposed. Based on the proposed constituted, the flexural moment-curvature relationship was calculated and compared with experimental data on prestressed UHPFRC beams. Good agreement between calculated strengths and experimental data is obtained.

Seismic performance of CFS shear wall systems filled with polystyrene lightweight concrete: Experimental investigation and design methodology

  • Mohammad Rezaeian Pakizeh;Hossein Parastesh;Iman Hajirasouliha;Farhang Farahbod
    • Steel and Composite Structures
    • /
    • v.46 no.4
    • /
    • pp.497-512
    • /
    • 2023
  • Using light weight concrete as infill material in conventional cold-formed steel (CFS) shear wall systems can considerably increase their load bearing capacity, ductility, integrity and fire resistance. The compressive strength of the filler concrete is a key factor affecting the structural behaviour of the composite wall systems, and therefore, achieving maximum compressive strength in lightweight concrete while maintaining its lightweight properties is of significant importance. In this study a new type of optimum polystyrene lightweight concrete (OPLC) with high compressive strength is developed for infill material in composite CFS shear wall systems. To study the seismic behaviour of the OPLC-filled CFS shear wall systems, two full scale wall specimens are tested under cyclic loading condition. The effects of OPLC on load-bearing capacity, failure mode, ductility, energy dissipation capacity, and stiffness degradation of the walls are investigated. It is shown that the use of OPLC as infill in CFS shear walls can considerably improve their seismic performance by: (i) preventing the premature buckling of the stud members, and (ii) changing the dominant failure mode from brittle to ductile thanks to the bond-slip behaviour between OPLC and CFS studs. It is also shown that the design equations proposed by EC8 and ACI 318-14 standards overestimate the shear force capacity of OPLC-filled CFS shear wall systems by up to 80%. This shows it is necessary to propose methods with higher efficiency to predict the capacity of these systems for practical applications.

A Study on Structural Simulation for Development of High Strength and Lightweight 48V MHEV Battery Housing (고강도 경량 48V MHEV 배터리 하우징 개발을 위한 구조시뮬레이션에 관한 연구)

  • Yong-Dae Kim;Jeong-Won Lee;Eui-Chul Jeong;Sung-Hee Lee
    • Design & Manufacturing
    • /
    • v.17 no.1
    • /
    • pp.48-55
    • /
    • 2023
  • In this study, on the structure simulation for manufacturing a high strength/light weight 48V battery housing for a mild hybrid vehicle was conducted. Compression analysis was performed in accordance with the international safety standards(ECE R100) for existing battery housings. The effect of plastic materials on compressive strength was analyzed. Three models of truss, honeycomb and grid rib for the battery housing were designed and the strength characteristics of the proposed models were analyzed through nonlinear buckling analysis. The effects of the previous existing rib, double-sided grid rib, double-sided honeycomb rib and double-sided grid rib with a subtractive draft for the upper cover on the compressive strength in each axial direction were examined. It was confirmed that the truss rib reinforcement of the battery housing was very effective compared to the existing model and it was also confirmed that the rib of the upper cover had no significant effect. In the results of individual 3-axis compression analysis, the compression load in the lateral long axis direction was the least and this result was found to be very important to achieve the overall goal in designing the battery housing. To reduce the weight of the presented battery housing model, the cell molding method was applied. It was confirmed that it was very effective in reducing injection pressure, clamping force and weight.

  • PDF

A STUDY OF THE STRESS DISTRIBUTION ON THE SECOND ABUTMENT AND SUPPORTING TISSUES IN FIXED PARTIAL DENTURE USING THREE DIMENSIONAL FINITE ELEMENT ANALYSIS METHOD (고정성 가공의치에서 이차 지대치에 발생하는 응력의 삼차원 유한요소법적 분석)

  • Kim, Jeong-Hee;Jo, Kwang-Hun;Lee, Cheong-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.675-694
    • /
    • 2000
  • The purpose of this study was to investigate the displacement of and the stress distribution on the prosthesis, abutment, and its supporting tissues under functional load, and the effect of alteration in root length of 2nd abutment. The 3-dimensional finite element method was used and the finite element models were prepared in which the abutments of left mandibular 5 unit axed partial denture were canine, the 1st pre-molar and the 2nd molar, and the root lengths of canines were as follows. Model I : Root length of canine was 2mm longer than the 1st premolar Model II : Root length of canine was 2mm shorter than the 1st premolar Static compressive force of 300N was applied to connector between 2nd premolar & 1st molar, and then von Mises stress, displacement and reaction force were obtained. The results were as follows : 1. In fixed partial denture, prosthesis under load on pontic was rotated around mesio-distal long axis of it from longual side to buccal, and simultaneously bended in buccal and gingival direction with mesial end deformed in gingival direction and distolingual end in occlusal. 2. Clinical crowns of abutments were bended in the same directions with those in which prosthesis deforms. Due to that, roots of anterior abutments were twisted in counterclockwise with concentration of shear stress on distal or distobuccal sides of their cervices, and that of posterior was in clockwise with concentration of shear stress on mesiobuccal side of it in the same level with anterior abutments. 3. In case that root length of the 2nd abutment was longer than that of the 1st abutment, its displacement and reaction force which means the force tooth exerts on the surrounding periodontal tissues were smaller but shear stress on itself was larger than in the case root length of 2nd abutment was shorter.

  • PDF

Finite Element Analysis of Concrete Railway Sleeper Damaged by Freezing Force of Water Penetrated into the Inserts (고속철도 콘크리트 궤도 매립전 내 침투수의 결빙압에 의한 균열손상해석)

  • Moon, Do-Young;Zi, Goang-Seup;Kim, Jin-Gyun;Jang, Seung-Yup
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.3
    • /
    • pp.240-247
    • /
    • 2011
  • Finite element analysis was undertaken to investigate the effect of freezing force of water unexpectedly penetrated into inserts used in railway sleeper on pullout capacity of anchor bolts for fixing base-plate onto concrete sleeper. Based on the in-situ investigation and measurement of geometry of railway sleeper and rail-fastener, the railway sleeper was modeled by 3D solid elements. Nonlinear and fracture properties for the finite element model were assumed according to CEB-FIP 1990 model code. And the pullout maximum load of anchor bolt obtained from the model developed was compared with experimental pullout maximum load presented by KRRI for verification of the model. Using this model, the effect of position of anchor bolt, amount of fastening force applied to the anchor bolt, and compressive strength of concrete on pull-out capacity of anchor bolts installed in railway sleeper was investigated. As a result, it is found that concrete railway sleepers could be damaged by the pressure due to freezing of water penetrated into inserts. And the pullout capacity of anchor bolt close to center of railway is slightly greater than that of the others.

Changes in Corrosion Progress and Ultimate load of Tendon Under 20% and 40% of Ultimate Loading Conditions (파괴하중의 20% 및 40% 인장조건에서 텐던 부식 진행 및 파괴하중 변화)

  • Ryu, Hwa-Sung;An, Gi Hong;Hwang, Chul-Sung;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.47-52
    • /
    • 2017
  • PSC (Prestressed Concrete) structures have been used widely for its engineering advantage with using total concrete area as effective compressive section. However tendon inside is exposed to such a high tensile stress that and more attentions should be paid for corrosion control. This work is for changing corrosion current and ultimate strength in tendon with increasing prestressing force in a constant corrosive condition. With increasing prestressing force, corrosion current, corrosion amount, and ultimate load are changed linearly. When prestressing force increases from 20.0 % to 40.0 %, corrosion current increases to 124.4 % and 168.0 % and ultimate load decreases to 87.8 % and 78.4 %, respectively. With inducing constant electrical potential, increasing corrosion current and reduction of strength are evaluated to be linearly related with increasing prestressing load.

Research on Acceleration Mechanism of Inflight Particle and Gas Flow Effect for the Velocity Control in Vacuum Kinetic Spray Process (진공상온분사(VKS) 공정에서의 비행입자 가속 기구 및 속도제어를 위한 가스 유량 효과에 관한 연구)

  • Park, Hyungkwon;Kwon, Juhyuk;Lee, Illjoo;Lee, Changhee
    • Korean Journal of Materials Research
    • /
    • v.24 no.2
    • /
    • pp.98-104
    • /
    • 2014
  • Vacuum kinetic spray(VKS) is a relatively advanced process for fabricating thin/thick and dense ceramic coatings via submicron-sized particle impact at room temperature. However, unfortunately, the particle velocity, which is an important value for investigating the deposition mechanism, has not been clarified yet. Thus, in this research, VKS average particle velocities were derived by numerical analysis method(CFD: computational fluid dynamics) connected with an experimental approach(SCM: slit cell method). When the process gas or powder particles are accelerated by a compressive force generated by gas pressure in kinetic spraying, a tensile force generated by the vacuum in the VKS system accelerates the process gas. As a result, the gas is able to reach supersonic speed even though only 0.6MPa gas pressure is used in VKS. In addition, small size powders can be accelerated up to supersonic velocity by means of the drag-force of the low pressure process gas flow. Furthermore, in this process, the increase of gas flow makes the drag-force stronger and gas distribution more homogenized in the pipe, by which the total particle average velocity becomes higher and the difference between max. and min. particle velocity decreases. Consequently, the control of particle size and gas flow rate are important factors in making the velocity of particles high enough for successful deposition in the VKS system.

Influence of Target Manufacturing Condition on the Coercive Force and Effective Permeability of Permalloy (타게트 제조조건이 퍼멀로이 박막의 보자력 및 투자율에 미치는 영향)

  • 김현태;김상주;한석희;김희중;강일구;김인응
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.4
    • /
    • pp.319-325
    • /
    • 1994
  • Permalloy films were deposited by an RF magnetron sputtering method using several different targets which had been cold-rolled and annealed at various temperatures to give different microstructure and texture. The grain refinement occurs at high temperature annealing due to recrystallization and subsequently the initial (110) target texture transforms to the random texture. The coercive forces of thin films fabricated using targets which are not recrystallized are below 0.2 Oe in the AI pressure range of 1~5 mTorr and the lowest coercive force achieved is 0.07 Oe. The low value of coercive force, 0.25 Oe, is only obtained at the sputtering conditions of 400 W and 1 mTorr, and 300 W and 5 mTorr when recrystallized targets are used. The internal stress changes from compressive to tensile as the Ar pressure increases, the stress-free being at 5 mTorr. The changes of coercive force and permeability can be well interpreted by the differences from the composition and the internal stress.

  • PDF

Seismic Performance Evaluation of Reinforced Concrete Bridge Columns under Varying Axial Force (변동 축하중을 받는 철근콘크리트 교각의 내진성능평가)

  • 김태훈;김운학;신현목
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.2
    • /
    • pp.67-73
    • /
    • 2003
  • The purpose of this study is to evaluate seismic performance of reinforced concrete bridge columns under varying axial force. A computer program, named RCAHEST(reinforced concrete analysis in higher evaluation system technology), for the analysis for reinforced concrete structures was used. Material nonlinearity is taken into account by comprising tensile, compressive and shear models of cracked concrete and a model of reinforcing steel. The smeared crack approach is incorporated. In boundary plane at which each member with different thickness is connected, local discontinuity in deformation due to the abrupt change in their stiffness can be taken into account by introducing interface element. The effect of number of load reversals with the same displacement amplitude has been also taken into account to model the reinforcing steel and concrete. The proposed numerical method for seismic performance evaluation of reinforced concrete bridge columns under varying axial force is verified by comparison with reliable experimental results.

An Analytical Study for Structural Behaviors of Unbonded Precast Rectangular Hollow Section Concrete Piers (비부착 프리캐스트 중공 사각 단면 교각의 구조거동에 관한 해석적 연구)

  • Choi, Seung-Won;Kim, Ick-Hyun;Cho, Jae-Yeo;Chang, Sung-Pil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1A
    • /
    • pp.61-69
    • /
    • 2010
  • Unbonded precast concrete piers have better seismic performances than conventional reinforced concrete piers. In this research, seismic performances of unbonded precast prestressed concrete piers are analyzed using OpenSEES. Main parameters of analysis are concrete strength, jacking force ratio, ratio of tendon, and size of precast segment. In results, as the ratio of tendon and jacking force ratio increase, the flexural strength increases at softening state and ultimate state. Concrete strength and size of precast segment are negligible. But initial jacking force ratio leads to early yielding of prestressing tendon. Since compressive strain in core concrete is much less than ultimate strain, it can be expected that the amount of transverse steel reinforcement is to be reduced in comparison with conventional reinforced concrete column.