• 제목/요약/키워드: Compression tests

검색결과 1,566건 처리시간 0.025초

Chemically Prestressed Precast Concrete Box Culvert with Expansive Additives

  • Park, Hong-Yong;Kim, Chul-Young;Park, Ik-Chang;Bae, Sang-Wook;Ryu, Jong-Hyun
    • KCI Concrete Journal
    • /
    • 제13권1호
    • /
    • pp.43-51
    • /
    • 2001
  • Although portland cement concrete is one of the most universal construction materials, it has some disadvantage such as shrinkage, which is an inherent characteristic. Because of this shrinkage, combined with the low tensile strength of the material, cracks of varying sizes can be found in every reinforced concrete. To prevent this cracking, keeping the concrete in compression by mechanical prestress has been used. This study discusses application of expansive additives for concrete to improve the serviceability of precast concrete box culvert by inducing chemical prestress. For this purpose, both expansive concrete slabs and normal concrete slabs are tested to verify the effect of expansive additives. Then the failure tests of the fullscale precast box culverts were carried out and the critical aspects of the structural behavior were investigated. The result of the material testis shows that the optimal proportion of expansive additives is 13 percent of cement weight, and the properties of expansive concrete are the same as those of normal concrete in that proportion. Both the experimental cracking load and service load of the expansive concrete members are increased in comparison with those of the normal concrete, but the ultimate load is decreased slightly. In addition to the above results, the deformation of expansive concrete member is lets than that of normal concrete member, and permanent strain which results from cyclic load is decreased. It can be concluded that the use of expansive additives to induce chemical prestress in precast concrete box culvert greatly improves the serviceability.

  • PDF

GFS-CFXB 내진보강법을 이용한 지진피해를 받은 R/C 건물의 내진성능 평가 및 내진보강 효과 (Seismic Strengthening and Performance Evaluation of Damaged R/C Buildings Strengthened with Glass Fiber Sheet and Carbon Fiber X-Brace System)

  • 이강석
    • 콘크리트학회논문집
    • /
    • 제25권6호
    • /
    • pp.667-674
    • /
    • 2013
  • 기존 강재 브레이싱 내진보강법은 정착부의 안정성 문제와 브레이싱의 국부좌굴이 발생할 문제가 있으며, 이를 방지하기 위한 추가보강으로 인해 불필요한 자중증가 등으로 경제적인 내진보강성능 확보에 어려움이 있다. 이 연구에서는 지진피해를 받은 건물에 지진피해로 인한 기존 기둥의 연성확보를 위해서 유리섬유시트(glass fiber sheet)로 래핑을 함과 동시에 기존 철골 X-브레이싱 내진보강법에 비교해서 경량의 고강도 재료로 보강 후 추가적인 중량증가가 거의 없으며, 브레이싱 압축 좌굴거동에 자유로운 탄소섬유 앵커 X-브레이싱공법(carbon fiber X-brace)을 조합한 경제적이며 효과적인 새로운 내진보강법(GFS-CFXB)을 제안하였다. 이 연구에서 제안한 GFS-CFXB공법의 유용성을 검증할 목적으로 지진피해를 받은 골조를 대상으로 반복가력에 의한 구조실험을 실시하여 내진성능 및 내진보강 효과를 검증하였다.

Aging Effect를 고려한 점성토의 압밀특성 (Consolidation Characteristics of Clays Considering the Aging Effect)

  • 김영수;이상웅;김대만;현영환
    • 한국지반공학회논문집
    • /
    • 제20권6호
    • /
    • pp.109-118
    • /
    • 2004
  • 점토의 압밀은 시간적 지연을 갖는 현상으로 시간적 지연은 소성적 지연시간과 수리적 지연시간으로 나눠진다. 본 연구에서는 점토의 2차압밀이 압밀침하에 어떠한 영향을 미치는지를 알고자 CRS 시험을 실시하였다. 시험결과 소성적 지연시간은 선행압밀하중을 구하는데 큰 영향을 미치는 것으로 나타났고, 압밀하중과 압밀지연시간으로부터 유사선행압밀하중을 예측하는 식을 제안하였다. 또 압밀지연시간에 따른 압밀계수의 특징은 선행압밀 전까지는 큰 범위의 값을 가지나 선행압밀하중의 약 2배 지점을 지나서는 압밀지연시간에 관계없이 일정한 값으로 수렴하는 경향을 나타냈다. 그리고 정규압밀영역에서의 투수계수는 간극비와 밀접한 관계에 있으며, Samarasinghe 등의 제안식을 이용하여 시험결과로부터 투수상수 n, $C_1$값을 결정하였고, Kozeny-Carman 제안식과 비교분석하여 보았다. 투수계수와 간극비 관계에서도 압밀지연시간에 의한 지연압축으로 인하여 aging effect를 관찰할 수 있었다.

3차원 직조형 열가소성수지 복합재료 제조 및 특성화 (Fabrication and Characterization of 3D Woven Textile Reinforced Thermoplastic Composites)

  • 홍순곤;변준형;이상관
    • Composites Research
    • /
    • 제16권2호
    • /
    • pp.33-40
    • /
    • 2003
  • 본 논문은 열경화성수지 적층 복합재료의 낮은 충격 특성과 층간 분리 현상을 개선하고자 열가소성 수지 및 3차원 직조 프리폼을 사용한 복합재료 제조와 물성 특성화에 대한 것이다. 새로운 기술인 co-braiding 성형법으로 열가소성 PEEK 섬유와 탄소섬유를 혼합한 섬유를 제조하였으며. 층간 분리 억제 특성을 현저하게 향상시키기 위하여 두께방향의 섬유를 가지는 3차원 직조형 프리폼을 제조하였다. 혼합섬유로 제조된 프리폼에 열성형 공정을 적용함으로써 열가소성 복합재료를 제조하였으며. 혼합섬유의 PEEK 섬유는 용융온도에서 용융되어 탄소섬유 사이로 함침이 완벽하게 일어남을 확인하였다. 또한, APC-2/AS4 프리프레그를 사용한 준 등방 적층 복합재료를 제조하여 3차원 직조형 열가소성 복합재료의 특성과 비교하였다. 항공기 소재로서의 적용 가능성을 알아보기 위하여 open hole 인장시험, 충격시험, 및 충격 후 압축시험 등의 결과를 통하여 3차원 직조형 열가소성 복합재료는 기존의 적층 복합재료보다 우수한 내 충격성 손상허용치를 가짐을 보였다.

EPS Foam의 변형률속도효과에 대한 연구 (Investigation of the Strain Rate Effects of EPS Foam)

  • 강우종;전성식;이인혁;최선웅;민제홍;이상혁;배봉국
    • Composites Research
    • /
    • 제23권3호
    • /
    • pp.64-68
    • /
    • 2010
  • EPS 폼은 충격하중으로부터 전자제품의 파손을 방지하기 위하여 포장재로 많이 사용되는 경량소재이며 밀도, 미세구조, 변형률 속도에 따라 에너지 흡수성능이 달라진다. 본 연구에서는 변형률속도와 밀도의 변화에 대한 EPS 폼의 에너지 흡수성능을 평가하기 위하여 18.5 ~ 37.0kg/m3의 밀도를 갖는 EPS 폼의 압축시험을 수행하였다. 중고속 압축시험을 위하여 낙하방식의 시험기를 개발, 사용하였으며 변형률 속도 0.06/s ~ 60/s에서의 압축시험을 통하여 EPS 폼의 변형률속도 효과를 분석하였다. 시험 결과 변형률 속도가 0.06/s에서 60/s로 증가할 경우 EPS 폼의 강도는 약 1.7배 증가하는 것으로 관찰되었다. 또한 변형률 속도에 따른 소재의 민감도는 변형률이 증가할수록 커지는 것으로 관찰되었다.

회귀분석법에 의한 복합재료 적층판의 압축파손강도 개발 (Development of Compressive Failure Strength for Composite Laminate Using Regression Analysis Method)

  • 이명건;이정원;윤동현;김재훈
    • 대한기계학회논문집A
    • /
    • 제40권10호
    • /
    • pp.907-911
    • /
    • 2016
  • 본 논문에서는 회귀분석법(regression analysis method)을 사용하여 개발된 복합재 적층판의 압축 파손강도값을 수록하였다. 본 논문에 사용된 복합재료는 $350^{\circ}F(177^{\circ}C$)에서 경화되는 Carbon/Epoxy UD Tape 프리프레그(Cycom G40-800/5276-1)이며 운용온도 범위는 $-60^{\circ}F{\sim}+200^{\circ}F$($-55^{\circ}C{\sim}+95^{\circ}C$)이다. 시편은 $0^{\circ}$, $+45^{\circ}$, $-45^{\circ}$$90^{\circ}$층으로 적층된 8종류의 노치없는 적층판으로 총 56개 시편으로 구성하였다. 시험방법은 ASTM-D-6484 규정을 사용하였다. 적층판의 압축 파손강도값은 적층판 내 $0^{\circ}$${\pm}45^{\circ}$층의 적층비율을 변수로 하는 회귀 분석법(regression analysis method)을 사용하여 획득하였다.

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • 제26권6호
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

Experimental study on the mechanical response and failure behavior of double-arch tunnels with cavities behind the liner

  • Zhang, Xu;Zhang, Chengping;Min, Bo;Xu, Youjun
    • Geomechanics and Engineering
    • /
    • 제20권5호
    • /
    • pp.399-410
    • /
    • 2020
  • Cavities often develop behind the vault during the construction of double-arch tunnels, generally in the form of various defects. The study evaluates the impact of cavities behind the vault on the mechanical and failure behaviors of double-arch tunnels. Cavities of the same sizes are introduced at the vault and the shoulder close to the central wall of double-arch tunnels. Physical model tests are performed to investigate the liner stress variation, the earth pressure distribution and the process of progressive failure. Results reveal that the presence of cavities behind the liner causes the re-distribution of the earth pressure and induces stress concentration near the boundaries of cavities, which results in the bending moments in the liner inside the cavity to reverse sign from compression to tension. The liner near the invert becomes the weak region and stress concentration points are created in the outer fiber of the liner at the bottom of the sidewall and central wall. It is suggested that grouting into the foundation soils and backfilling injection should be carried out to ensure the tunnel safety. Changes in the location of cavities significantly impact the failure pattern of the liner close to the vault, e.g., cracks appear in the outer fiber of the liner inside the cavity when a cavity is located at the shoulder close to the central wall, which is different from the case that the cavity locates at the vault, whereas changes in the location of cavities have a little influence on the liner at the bottom of the double-arch tunnels.

Incompatible deformation and damage evolution of mixed strata specimens containing a circular hole

  • Yang, Shuo;Li, Yuanhai;Chen, Miao;Liu, Jinshan
    • Geomechanics and Engineering
    • /
    • 제20권5호
    • /
    • pp.461-474
    • /
    • 2020
  • Analysing the incompatible deformation and damage evolution around the tunnels in mixed strata is significant for evaluating the tunnel stability, as well as the interaction between the support system and the surrounding rock mass. To investigate this issue, confined compression tests were conducted on upper-soft and lower-hard strata specimens containing a circular hole using a rock testing system, the physical mechanical properties were then investigated. Then, the incompatible deformation and failure modes of the specimens were analysed based on the digital speckle correlation method (DSCM) and Acoustic Emission (AE) data. Finally, numerical simulations were conducted to explore the damage evolution of the mixed strata. The results indicate that at low inclination angles, the deformation and v-shaped notches inside the hole are controlled by the structure plane. Progressive spalling failure occurs at the sidewalls along the structure plane in soft rock. But the transmission of the loading force between the soft rock and hard rock are different in local. At high inclination angles, v-shaped notches are approximately perpendicular to the structure plane, and the soft and hard rock bear common loads. Incompatible deformation between the soft rock and hard rock controls the failure process. At inclination angles of 0°, 30° and 90°, incompatible deformations are closely related to rock damage. At 60°, incompatible deformations and rock damage are discordant due that the soft rock and hard rock alternately bears the major loads during the failure process. The failure trend and modes of the numerical results agree very well with those observed in the experimental results. As the inclination angles increase, the proportion of the shear or tensile damage exhibits a nonlinear increase or decrease, suggesting that the inclination angle of mixed strata may promote shear damage and restrain tensile damage.

Assessment of the unconfined compression strength of unsaturated lateritic soil using the UPV

  • Wang, Chien-Chih;Lin, Horn-Da;Li, An-Jui;Ting, Kai-En
    • Geomechanics and Engineering
    • /
    • 제23권4호
    • /
    • pp.339-349
    • /
    • 2020
  • This study investigates the feasibility of using the results of the UPV (ultrasonic pulse velocity) test to assess the UCS (unconfined compressive strength) of unsaturated soil. A series of laboratory tests was conducted on samples of unsaturated lateritic soils of northern Taiwan. Specifically, the unconfined compressive test was combined with the pressure plate test to obtain the unconfined compressive strength and its matric suction (s) of the samples. Soil samples were first compacted at the designated water content and subsequently subjected to the wetting process for saturation and the following drying process to its target suction using the apparatus developed by the authors. The correlations among the UCS, s and UPV were studied. The test results show that both the UCS and UPV significantly increased with the matric suction regardless of the initial compaction condition, but neither the UCS nor UPV obviously varied when the matric suction was less than the air-entry value. In addition, the UCS approximately linearly increased with increasing UPV. According to the investigation of the test results, simplified methods to estimate the UCS using the UPV or matric suction were established. Furthermore, an empirical formula of the matric suction calculated from the UPV was proposed. From the comparison between the predicted values and the test results, the MAPE values of UCS were 4.52-9.98% and were less than 10%, and the MAPE value of matric suction was 17.3% and in the range of 10-20%. Thus, the established formulas have good forecasting accuracy and may be applied to the stability analysis of the unsaturated soil slope. However, further study is warranted for validation.